Real-time continuous glucose monitoring in adults with type 1 diabetes and impaired hypoglycaemia awareness or severe hypoglycaemia treated with multiple daily insulin injections (HypoDE): a multicentre, randomised controlled trial
The DOI matches its Crossref record; 29 of the 30 references it cites were found in a registry or an index.
Abstract
Background The effectiveness of real-time continuous glucose monitoring (rtCGM) in avoidance of hypoglycaemia among high-risk individuals with type 1 diabetes treated with multiple daily insulin injections (MDI) is unknown. We aimed to ascertain whether the incidence and severity of hypoglycaemia can be reduced through use of rtCGM in these individuals. Methods The HypoDE study was a 6-month, multicentre, open-label, parallel, randomised controlled trial done at 12 diabetes practices in Germany. Eligible participants had type 1 diabetes and a history of impaired hypoglycaemia awareness or severe hypoglycaemia during the previous year. All participants wore a masked rtCGM system for 28 days and were then randomly assigned to 26 weeks of unmasked rtCGM (Dexcom G5 Mobile system) or to the control group (continuing with self-monitoring of blood glucose). Block randomisation with 1:1 allocation was done centrally, with the study site as the stratifying variable. Masking of participants and study sites was not possible. Control participants wore a masked rtCGM system during the follow-up phase (weeks 22-26). The primary outcome was the baseline-adjusted number of hypoglycaemic events (defined as glucose ≤3·0 mmol/L for ≥20 min) during the follow-up phase. The full dataset analysis comprised participants who wore the rtCGM system during the baseline and follow-up phases. The intention-to-treat analysis comprised all randomised participants. This trial is registered with ClinicalTria…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“CGM can reveal asymptomatic hypoglycemia and help identify patterns and precipitants of hypoglycemic events and provide alarms that can warn individuals of falling glucose so that they can intervene (150,151).”
From 6. Glycemic Goals, Hypoglycemia, and Hyperglycemic Crises: Standards of Care in Diabetes-2026. (2026) · cites this paper as [150]
In the citing paper
“Several clinical trials have not shown a reduction of IAH by using CGM despite a reduced incidence of level 3 hypoglycemia (101,112,124,126-128).”
In the citing paper
“Hypoglycemia with glucose levels below 3.0 mmol/L (54 mg/dL) occurs much more often than previously appreciated (46,101).”
In the citing paper
“Reductions in HbA1c have been reported with CGM use in people on multiple daily injection (MDI) therapy,19 and continuous subcutaneous insulin infusion therapy,20 with reduced time spent in hypoglycemia,20 and improved hypoglycemia awareness.21”
From Increased Time in Range and Fewer Missed Bolus Injections After Introduction of a Smart Connected Insulin Pen (2020) · cites this paper as [21]
In the citing paper
“The leading CGMs on market today are Dexcom (CA, USA), Medtronic (MN, USA) and Abbott (IL, USA) devices [2-5,19,31].”
From Wearables and the Medical Revolution (2018) · cites this paper as [19]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Self-citationBeck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Hypoglycemia in the Diabetes Control and Complications Trial
The Diabetes Control and Complications Trial Research Group (1997) · Diabetes · doi:10.2337/diab.46.2.271 · Cited by 746
Lind, M., Polonsky, W., Hirsch, I. B., Heise, T., Bolinder, J., Dahlqvist, S., Schwarz, E., Ólafsdóttir, A. F., Frid, A., Wedel, H., et al. (2017) · JAMA · doi:10.1001/jama.2016.19976 · Cited by 705
Clarke, W. L., Cox, D. J., Gonder-Frederick, L. A., Julian, D., Schlundt, D., & Polonsky, W. (1995) · Diabetes Care · doi:10.2337/diacare.18.4.517 · Cited by 651
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
the SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493
Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 Diabetes
Battelino, T., Phillip, M., Bratina, N., Nimri, R., Oskarsson, P., & Bolinder, J. (2011) · Diabetes Care · doi:10.2337/dc10-1989 · Cited by 490
Hypoglycaemia in diabetes mellitus: epidemiology and clinical implications
Frier, B. M. (2014) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2014.170 · Cited by 481
Cited by
Items 101–200 of 528
Pleus, S., Ulbrich, S., Zschornack, E., Kamann, S., Haug, C., & Freckmann, G. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0171 · Cited by 47
Self-citationAggarwal, A., Pathak, S., & Goyal, R. (2022) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2022.109825 · Cited by 55
Roldan, V. D. T., Urtecho, M., Nayfeh, T., Firwana, M., Muthusamy, K., Hasan, B., Abd‐Rabu, R., Maraboto, A., Qoubaitary, A., Prokop, L. J., et al. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac601 · Cited by 49
Martos-Cabrera, M. B., Velando-Soriano, A., Pradas-Hernández, L., Suleiman-Martos, N., Cañadas-De la Fuente, G. A., Albendín-García, L., & Gómez-Urquiza, J. L. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9030693 · Cited by 45
Roze, S., Isitt, J., Smith-Palmer, J., Javanbakht, M., & Lynch, P. (2020) · Diabetes Care · doi:10.2337/dc19-2213 · Cited by 43
Rodbard, D. (2022) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14906 · Cited by 47
Talbo, M. K., Katz, A., Hill, L., Peters, T. M., Yale, J.-F., & Brazeau, A.-S. (2023) · eClinicalMedicine · doi:10.1016/j.eclinm.2023.102119 · Cited by 42
Electrochemical non-enzymatic glucose sensors based on CuO nanostructures
Yang, J., Yin, J., & Xu, L. (2024) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2024.177796 · Cited by 49
Thieu, V. T., Mitchell, B. D., Varnado, O. J., & Frier, B. M. (2020) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.13941 · Cited by 44
Herrero, P., Alalitei, A., Reddy, M., Georgiou, P., & Oliver, N. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0387 · Cited by 43
Comparisons of Fifth-, Sixth-, and Seventh-Generation Continuous Glucose Monitoring Systems
Welsh, J. B., Psavko, S., Zhang, X., Gao, P., & Balo, A. K. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221099879 · Cited by 50
Divilly, P., Martine‐Edith, G., Zaremba, N., Søholm, U., MAHMOUDI, Z., Cigler, M., Ali, N., Abbink, E. J., Brøsen, J. M. B., de Galan, B. E., et al. (2024) · Diabetes Care · doi:10.2337/dc23-2332 · Cited by 51
Amiel, S. A., Choudhary, P., Jacob, P., Smith, E. L., De Zoysa, N., Gonder-Frederick, L., Kendall, M., Heller, S., Brooks, A., Toschi, E., et al. (2019) · BMJ Open · doi:10.1136/bmjopen-2019-030356 · Cited by 41
Kang, S., Kang, S. M., Choi, J. H., Ko, S., Koo, B. K., Kwon, H.-S., Kim, M. K., Kim, S. Y., Kim, S., Kim, Y., et al. (2025) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2025.0469 · Cited by 85
Significance of Glycemic Variability in Diabetes Mellitus
Kusunoki, Y., Konishi, K., Tsunoda, T., & Koyama, H. (2022) · Internal Medicine · doi:10.2169/internalmedicine.8424-21 · Cited by 40
“The use of real-time CGM and flash glucose monitoring (FGM) reduces hypoglycemia and improves GV (127-129).”
BackgroundMethodGraña, C., Ravaud, P., Ghosn, L., & Tran, V.-T. (2020) · BMC Medicine · doi:10.1186/s12916-020-01773-w · Cited by 46
Reddy, M., & Oliver, N. S. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15504 · Cited by 47
Lin, Y. K., Groat, D., Chan, O., Hung, M., Sharma, A., Varner, M. W., Gouripeddi, R., Facelli, J. C., & Fisher, S. J. (2020) · Journal of the Endocrine Society · doi:10.1210/jendso/bvz005 · Cited by 39
“While multiple clinical trials have proven the utility of CGMs in reducing both hypo- and hyperglycemia [2, 3, 6, 7], retrospectively, many patients in these studies still failed to reach the recently proposed targets, and questions remain on how to improve glucose control in this population.”
BackgroundMethodAvari, P., Tang, W., Jugnee, N., Hersi, I., Al‐Balah, A., Tan, T., Frankel, A., Oliver, N. S., & Reddy, M. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0013 · Cited by 40
“…reductions in HbA1c and reduced exposure to hypoglycemia, 15,16 particularly in those with impaired awareness and in people at hypoglycemia risk 17,18 Intermittently scanned continuous glucose monitoring (isCGM, Freestyle Libre 1, Abbott) enables glucose data to be viewed when the user swipes…”
Lu, Q., Huang, T., Zhou, J., Zeng, Y., Wu, C., Liu, M., Li, H., Zhang, Y., & Yao, S. (2020) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2020.118893 · Cited by 40
Charleer, S., De Block, C., Nobels, F., Radermecker, R. P., Lowyck, I., Mullens, A., Scarnière, D., Spincemaille, K., Strivay, M., Weber, E., et al. (2020) · Diabetes Care · doi:10.2337/dc20-1531 · Cited by 39
Flatt, A. J., Peleckis, A. J., Dalton-Bakes, C., Nguyen, H.-L., Ilany, S., Matus, A., Malone, S. K., Goel, N., Jang, S., Weimer, J., et al. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0506 · Cited by 39
“…the use of real-time CGM in this population over at least a 4-month period reduces hypoglycemia frequency and severity without increasing HbA 1c , however, does not eliminate severe hypoglycemia and has been shown to only modestly improve hypoglycemia awareness in one 19 but not all 20–22 studies.”
Lucidi, P., Porcellati, F., Bolli, G. B., & Fanelli, C. G. (2018) · Current Diabetes Reports · doi:10.1007/s11892-018-1065-6 · Cited by 38
Garg, S. K., Hirsch, I. B., Repetto, E., Snell‐Bergeon, J. K., Ulmer, B. J., Perkins, C., & Bergenstal, R. M. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15866 · Cited by 43
Choudhary, P., Campbell, F., Joule, N., Kar, P., & on behalf of Diabetes, U. K. (2019) · Diabetic Medicine · doi:10.1111/dme.13933 · Cited by 38
“Two recent RCTs have also demonstrated the safety and efficacy of CGM in those with impaired awareness of hypoglycaemia [13,36] and, in this group, CGM may be an effective alternative to CSII in order to reduce the risk of severe hypoglycaemia.”
BackgroundAl‐Ozairi, E., Samad, A. E., Kandari, J. A., & Aldibbiat, A. M. (2019) · Frontiers in Endocrinology · doi:10.3389/fendo.2019.00849 · Cited by 45
Lin, Y. K., Groat, D., Chan, O. T. M., Hung, M., Sharma, A. R., Varner, M. W., Gouripeddi, R., Facelli, J. C., & Fisher, S. J. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0016 · Cited by 39
Benhamou, P., Lablanche, S., Vambergue, A., Doron, M., Franc, S., & Charpentier, G. (2020) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14214 · Cited by 41
Burckhardt, M., Abraham, M. B., Dart, J., Smith, G. J., Paramalingam, N., O’Dea, J. M., de Bock, M. I., Davis, E. A., & Jones, T. W. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0593 · Cited by 43
“37,38 The failure to demonstrate an improvement in other self-reported outcomes such as fear of hypoglycemia evaluated with the HFS total and worry score is in line with findings from a longer term real-life study.”
Priesterroth, L., Grammes, J., Clauter, M., & Kubiak, T. (2021) · Diabetic Medicine · doi:10.1111/dme.14581 · Cited by 43
Evaluating Glucose Control With a Novel Composite Continuous Glucose Monitoring Index
Leelarathna, L., Thabit, H., Wilinska, M. E., Bally, L., Mader, J. K., Pieber, T. R., Benesch, C., Arnolds, S., Johnson, T. K., Heinemann, L., et al. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819838525 · Cited by 41
“Usage of real-time CGM by multiple daily injection (MDI) users has been shown to improve HbA1c(3) and reduce the burden of hypoglycemia.(4) There is increasing recognition of the limitations of HbA1c as the sole measure of glycemic control, as it provides little or no information on clinically relevant outcomes such a…”
BackgroundMethodSelf-citationKim, J. Y., Jin, S.-M., Sim, K. H., Kim, B.-Y., Cho, J. H., Moon, J. S., Lim, S., Kang, E. S., Park, C.-Y., Kim, S. G., et al. (2024) · Diabetologia · doi:10.1007/s00125-024-06152-1 · Cited by 36
PAULEY, M. E., Tommerdahl, K. L., Snell‐Bergeon, J. K., & Forlenza, G. P. (2022) · Current Cardiology Reports · doi:10.1007/s11886-022-01799-x · Cited by 46
Continuous Glucose Monitoring to Optimize Management of Diabetes in Patients with Advanced CKD
Galindo, R. J., de Boer, I. H., Neumiller, J. J., & Tuttle, K. R. (2022) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.04510422 · Cited by 36
Oliver, N. S., Giménez, M., Calhoun, P. M., Cohen, N., Moscardó, V., Hermanns, N., Freckmann, G., Reddy, M., & Heinemann, L. (2019) · Diabetes Care · doi:10.2337/dc19-0977 · Cited by 39
“Data Sources Data for analysis were obtained from the Multiple Daily Injections and Continuous Glucose Monitoring in Diabetes (DIAMOND) (8) and HypoDE (13) studies.”
MethodSelf-citationAleppo, G., Hirsch, I. B., Parkin, C. G., McGill, J., Galindo, R., Kruger, D. F., Levy, C. J., Forlenza, G. P., Umpierrez, G. E., Grunberger, G., et al. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0268 · Cited by 34
Jacobsen, L. M., Sherr, J. L., Considine, E. G., Chen, A. X., Peeling, S., Hulsmans, M., Charleer, S., Urazbayeva, M., Tosur, M., ALAMARIE, S. A., et al. (2023) · Communications Medicine · doi:10.1038/s43856-023-00358-x · Cited by 42
“Additionally, in a subgroup with albuminuria present at screening (UACR ≥ 30 mg/g), there was an 18% reduction in UACR in the SAP group compared to + 38% in the MDI group ( p = 0.011) 55 .”
BackgroundMethodInfluentialAccuracy of Continuous Glucose Monitoring in Hemodialysis Patients With Diabetes
Narasaki, Y., Kalantar‐Zadeh, K., Daza, A. C., You, A. S., Novoa, A., Peralta, R. A., Siu, M. K. M., Nguyen, D. V., & Rhee, C. M. (2024) · Diabetes Care · doi:10.2337/dc24-0635 · Cited by 40
Discordance Between Glucose Management Indicator and Glycated Hemoglobin in People Without Diabetes
Shah, V. N., Vigers, T., Pyle, L. L., Calhoun, P. M., & Bergenstal, R. M. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0544 · Cited by 41
Dovč, K., Cargnelutti, K., Sturm, A., Šelb, J., Bratina, N., & Battelino, T. (2018) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2018.10.005 · Cited by 42
Performance and Usability of Three Systems for Continuous Glucose Monitoring in Direct Comparison
Freckmann, G., Link, M., Kamecke, U., Haug, C., Baumgartner, B., & Weitgasser, R. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819826965 · Cited by 35
Self-citationPrasad‐Reddy, L., Godina, A., Chetty, A. K., Close Concerns, S. F., & Isaacs, D. (2022) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2022.18.2.116 · Cited by 42
Person‐reported outcomes in diabetes care: What are they and why are they so important?
Hermanns, N., Kulzer, B., & Ehrmann, D. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15471 · Cited by 36
“103,148 In summary, sensitivity to change is an important characteristic for detecting diabetes treatment effects of small size or magnitude.”
BackgroundSelf-citationSmart orthopaedic implants: A targeted approach for continuous postoperative evaluation in the spine
Ramakrishna, V. A. S., Chamoli, U., Rajan, G., Mukhopadhyay, S. C., Prusty, B. G., & Diwan, A. D. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.109690 · Cited by 35
Gal, R. L., Cohen, N. J., Kruger, D., Beck, R. W., Bergenstal, R. M., Calhoun, P., Cushman, T., Haban, A., Hood, K., Johnson, M. L., et al. (2020) · Journal of the Endocrine Society · doi:10.1210/jendso/bvaa076 · Cited by 32
“The amount of improvement in HbA1c and CGM-measured glycemic metrics was similar to that observed in clinic-based randomized trials [1, 8, 9, 11, 12, 28], but these results should be viewed in the context that this was a small feasibility study with no control group.”
BackgroundResultBlood Glucose Monitoring in Adults and Children with Diabetes: Update 2021
CHENG, A. Y. Y., Feig, D. S., Ho, J., Siemens, R. L., BAJAJ, H. S., Gilbert, J. D., Houlden, R. L., Kim, J., MacKay, D., Rabi, D. M., et al. (2021) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2021.07.003 · Cited by 41
Continuous glucose monitoring: transforming diabetes management step by step
Bergenstal, R. M. (2018) · The Lancet · doi:10.1016/s0140-6736(18)30290-3 · Cited by 37
Lau, D., Manca, D. P., Singh, P., Perry, T., Olu-Jordan, I., Ryan Zhang, J., Rahim, G., Hagen, E. M., & Yeung, R. O. (2024) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2024.111899 · Cited by 32
Zhu, T., Li, K., & Georgiou, P. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3303367 · Cited by 50
“The use of real-time continuous glucose monitoring (CGM) systems [8] has increased rapidly in recent years, and they have been shown to reduce severe hypoglycemia in people with T1D either using MDI therapy [9] or CSII therapy [10], [11].”
MethodLACY, M. E., Lee, K. E., Ataç, Ö., Heier, K., Fowlkes, J. L., Kucharska‐Newton, A., & Moga, D. C. (2024) · Clinical Diabetes · doi:10.2337/cd23-0051 · Cited by 35
Norman, G. J., Paudel, M. L., Parkin, C. G., Bancroft, T., & Lynch, P. M. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0525 · Cited by 37
Hypoglycaemia in type 1 diabetes mellitus: risks and practical prevention strategies
Kaur, J., & Seaquist, E. R. (2022) · Nature Reviews Endocrinology · doi:10.1038/s41574-022-00762-8 · Cited by 38
Beato-Víbora, P. I. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0184 · Cited by 33
RetractedSepúlveda, E., Poínhos, R., Nata, G., Carvalho, D. M., Neves, J. S., Seixas, D., Choudhary, P., Vicente, S., & Amiel, S. A. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0034 · Cited by 32
Benefits and limitations of continuous glucose monitoring in type 1 diabetes
Stone, J. Y., & Bailey, T. S. (2020) · Expert Review of Endocrinology & Metabolism · doi:10.1080/17446651.2020.1706482 · Cited by 30
“Many of these glycemic benefits have also been found to be true in select high-risk populations, including seniors over the age of 65 [23] and those with impaired hypoglycemic awareness [22,24].”
BackgroundDiabetes: the role of continuous glucose monitoring
Kluemper, J. R., Smith, A. C., & Wobeter, B. R. (2022) · Drugs in Context · doi:10.7573/dic.2021-9-13 · Cited by 33
Adolfsson, P., Rentoul, D., Klinkenbijl, B., & Parkin, C. G. (2018) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2018.14.2.50 · Cited by 39
“51 EUROPEAN ENDOCRINOLOGY reliance on conventional blood glucose monitoring.(16) Investigators also reported that rtCGM use resulted in a significant decrease in the frequency of clinical severe hypoglycaemia and reduced glycaemic variability, a known risk factor for hypoglycaemia.”
BackgroundAvari, P., Moscardó, V., Jugnee, N., Oliver, N. S., & Reddy, M. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819867688 · Cited by 31
“In addition, rtCGM reduces hypoglycemic events compared to self-monitoring blood glucose (SMBG) in people with impaired hypoglycemia awareness.(18,19) Intermittently scanned continuous glucose monitoring (iscCGM) is a factory calibrated sensor which when scanned displays glucose concentrations and trend along with up…”
BackgroundRidder, F. D., den Brinker, M., & Block, C. E. M. D. (2019) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/2042018819871903 · Cited by 33
Flatt, A. J., Little, S. A., Speight, J., Leelarathna, L., Walkinshaw, E., Tan, H. K., Bowes, A., Lubina-Solomon, A., Holmes‐Truscott, E., Chadwick, T. J., et al. (2019) · Diabetes Care · doi:10.2337/dc19-0630 · Cited by 33
“This is leading to rapidly accruing evidence for successful reduction in severe hypoglycemia following both education (4) and technology interventions (5,6) so that severe hypoglycemia should no longer be accepted as an inevitable consequence of established type 1 diabetes (7).”
BackgroundHypoglycemia in cystic fibrosis: Prevalence, impact and treatment
Moheet, A. A., Chan, C. L., Granados, A., Ode, K. L., Moran, A., & Battezzati, A. (2019) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2019.08.004 · Cited by 30
Sala, L. L., & Pontiroli, A. E. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms221910643 · Cited by 31
“Usage of real time Continuous Glucose Monitoring reduces the number of hypoglycemic events in individuals with T1D treated by multiple daily injected (MDI) and with impaired hypoglycemia awareness or severe hypoglycemia [43].”
BackgroundMartin, C., Criego, A. B., Carlson, A. L., & Bergenstal, R. M. (2019) · Current Diabetes Reports · doi:10.1007/s11892-019-1177-7 · Cited by 34
Acciaroli, G., Welsh, J. B., & Akturk, H. K. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820982584 · Cited by 27
De Meulemeester, J., Keymeulen, B., De Block, C., Van Huffel, L., Taes, Y., Ballaux, D., Spincemaille, K., Lapauw, B., Vanhaverbeke, G., Lowyck, I., et al. (2025) · Diabetologia · doi:10.1007/s00125-025-06366-x · Cited by 27
“Although our study did not yield direct evidence to clarify this discrepancy, we cannot dismiss the possibility that the impact of an HCL system on hypoglycaemia awareness is due to technological recognition rather than an actual restoration of physiological awareness [30, 31].”
Been, R. A., Lameijer, A., Gans, R. O. B., van Beek, A. P., Kingsnorth, A. P., Choudhary, P., & van Dijk, P. R. (2024) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/20420188241236289 · Cited by 31
“5 These CGM devices have been proven to be beneficial for both people with type 1 6,7 and type 2 diabetes.”
BackgroundContinuous Glucose Monitoring–Derived Data Report—Simply a Better Management Tool
Battelino, T., & Bergenstal, R. M. (2020) · Diabetes Care · doi:10.2337/dci20-0032 · Cited by 28
Mesa, A., Giménez, M., Pueyo, I., Perea, V., Viñals, C., Blanco, J., Vinagre, I., Serés‐Noriega, T., Boswell, L., Esmatjes, E., et al. (2022) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2022.109938 · Cited by 31
Nocturnal Hypoglycemia in the Era of Continuous Glucose Monitoring
Kulzer, B., Freckmann, G., Ziegler, R., Schnell, O., Glatzer, T., & Heinemann, L. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241267823 · Cited by 33
Self-citationPractical guidance for using the FreeStyle Libre flash continuous glucose monitoring in primary care
Unger, J., Kushner, P. R., & Anderson, J. E. (2020) · Postgraduate Medicine · doi:10.1080/00325481.2020.1744393 · Cited by 30
Ehrmann, D., Heinemann, L., Freckmann, G., Waldenmaier, D., Faber-Heinemann, G., & Hermanns, N. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0332 · Cited by 27
“9 Since improvement of glycemic control and hypoglycemia problems are two key components of diabetes therapy and are important goals for people with diabetes, it can be expected that rtCGM substantially impacts daily living with diabetes.”
InfluentialSelf-citationIschemic brain injury in diabetes and endoplasmic reticulum stress
Rehni, A. K., Cho, S., & Dave, K. R. (2021) · Neurochemistry International · doi:10.1016/j.neuint.2021.105219 · Cited by 27
Murata, T., Hosoda, K., Nishimura, K., Miyamoto, Y., Sakane, N., Satoh‐Asahara, N., Toyoda, M., Hirota, Y., Matsuhisa, M., Kuroda, A., et al. (2022) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2022.110147 · Cited by 37
The Use of Continuous Glucose Monitoring to Diagnose Stage 2 Type 1 Diabetes
Mader, J. K., Wong, J. C., Freckmann, G., Garcia‐Tirado, J., Hirsch, I. B., Johnson, S. B., Kerr, D. E., Kim, S. H., Lal, R., Montaser, E., et al. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251333441 · Cited by 32
Self-citationUtilizing continuous glucose monitoring in primary care practice: What the numbers mean
Edelman, S. V., Cavaiola, T. S., BOEDER, S. C., & Pettus, J. (2020) · Primary care diabetes · doi:10.1016/j.pcd.2020.10.013 · Cited by 27
Gavin, J. R., & Bailey, C. J. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0211 · Cited by 29
Ratzki‐Leewing, A., Black, J. E., Kahkoska, A. R., Ryan, B. L., Zou, G., Klar, N., Timcevska, K., & Harris, S. B. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.15268 · Cited by 24
Kruger, D. F., & Anderson, J. E. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0193 · Cited by 30
Rotondi, M. A., Wong, O. C. Y., Riddell, M. C., & Perkins, B. A. (2022) · Diabetes Care · doi:10.2337/dc21-2341 · Cited by 28
Ehrmann, D., Priesterroth, L., SCHMITT, A. J., Kulzer, B., & Hermanns, N. (2021) · Diabetes Spectrum · doi:10.2337/ds20-0096 · Cited by 24
Self-citationTime in range—A new gold standard in type 2 diabetes research?
Goshrani, A., Lin, R., O'Neal, D. N., & Ekinci, E. I. (2025) · Diabetes Obesity and Metabolism · doi:10.1111/dom.16279 · Cited by 26
“58,59 CV%, which reflects glycaemic variability (GV), is calculated by dividing the standard deviation (SD) of sensor glucose (SG) values by the mean SG value over the same observation period x100, and a threshold of 36% has been shown to differentiate between stable and unstable glycemia.”
2021 Clinical Practice Guidelines for Diabetes Mellitus in Korea
Ko, S. (2021) · Journal of Korean Diabetes · doi:10.4093/jkd.2021.22.4.244 · Cited by 23
Bahrami, J., TOMLINSON, G. A., Murphy, H. R., Feig, D. S., & the CONCEPTT Collaborative Group (2022) · Diabetic Medicine · doi:10.1111/dme.14789 · Cited by 23
Huhn, F., Lange, K., Jördening, M., & Ernst, G. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221081216 · Cited by 28
Yu, X., Fan, M., Zhao, X., Ding, Y., Liu, X., Yang, S., & Zhang, X. (2023) · Diabetic Medicine · doi:10.1111/dme.15129 · Cited by 27
Cho, S. H., Kim, S., Lee, Y., Jin, S., Hur, K. Y., Kim, G., & Kim, J. H. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1165471 · Cited by 29
Wright, E. E., Roberts, G. J., Chuang, J. S., Nabutovsky, Y., Virdi, N., & Miller, E. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0015 · Cited by 22
Beyond A1C: exploring continuous glucose monitoring metrics in managing diabetes
Friedman, J. G., Coyne, K., Aleppo, G., & Szmuilowicz, E. D. (2023) · Endocrine Connections · doi:10.1530/ec-23-0085 · Cited by 22
Assessment of the Glucose Management Indicator Using Different Sampling Durations
Bailey, R. J., Calhoun, P. M., Bergenstal, R. M., & Beck, R. W. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0284 · Cited by 23
Ridder, F. D., den Brinker, M., & Block, C. E. M. D. (2019) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/2042018819865399 · Cited by 23
Hypoglycaemia and its management in primary care setting
Ibrahim, M., Baker, J., Cahn, A., Eckel, R. H., El Sayed, N. A., Fischl, A. H., Gaede, P., Leslie, R. D., Pieralice, S., Tuccinardi, D., et al. (2020) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.3332 · Cited by 21
Multi-Horizon Glucose Prediction Across Populations With Deep Domain Generalization
Zhu, T., Afentakis, I., Li, K., Armiger, R., Hill, N. E., Oliver, N. S., & Georgiou, P. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3428921 · Cited by 26
“In light of this, the rapid evolution of real-time continuous glucose monitoring (CGM) over the past decades has demonstrated its potential to support optimal self-management and increase the percentage of time that blood glucose within the target range [4], [5].”
Time above range for predicting the development of type 2 diabetes
Marco, A., Pazos-Couselo, M., Moreno-Fernández, J., Díez‐Fernández, A., Alonso‐Sampedro, M., Fernández‐Merino, C., González‐Quintela, A., & Gudé, F. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2022.1005513 · Cited by 26
Ruan, Y., Bally, L., Thabit, H., Leelarathna, L., Hartnell, S., Tauschmann, M., Wilinska, M. E., Evans, M. L., Mader, J. K., Kojzar, H., et al. (2018) · Diabetes Obesity and Metabolism · doi:10.1111/dom.13304 · Cited by 22
“Continuous glucose monitoring also leads to improved glucose control and reduces the risk of hypoglycaemia(4) and severe hypoglycaemia in adults with type 1 diabetes.(5) Closed-loop glucose control, combining insulin delivery with real-time glucose sensing to administer insulin in a glucose-responsive fashion, further…”
BackgroundChoudhary, P., de Portu, S., Arrieta, A., Castañeda, J., & Campbell, F. (2019) · Diabetic Medicine · doi:10.1111/dme.14043 · Cited by 23
Garg, S., & Norman, G. J. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0656 · Cited by 24
Fear of Hypoglycemia and Diabetes Distress: Expected Reduction by Glucose Prediction
Ehrmann, D., Laviola, L., Priesterroth, L.-S., Hermanns, N., Babion, N., & Glatzer, T. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241267886 · Cited by 20
Self-citationContinuous glucose sensor accuracy: beyond the headline metric
Oliver, N. S., Reddy, M., & Leelarathna, L. (2024) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(24)00245-6 · Cited by 23
Managing discordance between HbA 1c and glucose management indicator
Lenters‐Westra, E., Fokkert, M. J., Kilpatrick, E. S., Schleicher, E. D., Pilla, S. J., English, E., & van Dijk, P. R. (2025) · Diabetic Medicine · doi:10.1111/dme.70023 · Cited by 21
“30,31 Subsequently, these two equations were combined for a greater precision by Bergenstal et al. 13 As well as different equations being used to link glucose to HbA 1c , different mathematical models have also been developed.”
Performance of the Glucose Management Indicator (GMI) in Type 2 Diabetes
Fang, M., Wang, D., Rooney, M. R., Echouffo-Tcheugui, J. B., Coresh, J., Aurora, R. N., Punjabi, N. M., & Selvin, E. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvac210 · Cited by 26
Metadata
- Authors
- Heinemann, L., Freckmann, G., Ehrmann, D., Faber-Heinemann, G., Guerra, S., Waldenmaier, D., & Hermanns, N.
- Affiliations
- Universität Ulm (DE)
- Forschungsinstitut der Diabetes Akademie Mergentheim (DE)
- Dexcom (United States) (US)
- Corresponding author
- Hermanns, Norbert
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2018-04
- Volume
- 391
- Issue
- 10128
- Pages
- 1367-1377
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2786804638
- Semantic Scholar
- 27c53707e53da8a72709f9893d5aeda31a2c9947
- Cited by
- 522
- References
- 30
- Citations by year
- 2026: 33 · 2025: 49 · 2024: 75 · 2023: 65 · 2022: 73 · 2021: 73 · 2020: 62 · 2019: 63 · 2018: 28
- FWCI
- 44.97
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Dexcom
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- real-time continuous glucose monitoring, type 1 diabetes, hypoglycemia, severe hypoglycemia, multiple daily insulin injections, hypoglycemia prevention, self-monitoring of blood glucose, adults with diabetes
- MeSH terms
- Adult, Awareness, Blood Glucose, Diabetes Mellitus, Type 1, Drug Administration Schedule, Female, Follow-Up Studies, Humans, Hypoglycemia, Hypoglycemic Agents, Injections, Subcutaneous, Insulin, Male, Middle Aged, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.