Real-time continuous glucose monitoring in adults with type 1 diabetes and impaired hypoglycaemia awareness or severe hypoglycaemia treated with multiple daily insulin injections (HypoDE): a multicentre, randomised controlled trial
The DOI matches its Crossref record; 29 of the 30 references it cites were found in a registry or an index.
Abstract
Background The effectiveness of real-time continuous glucose monitoring (rtCGM) in avoidance of hypoglycaemia among high-risk individuals with type 1 diabetes treated with multiple daily insulin injections (MDI) is unknown. We aimed to ascertain whether the incidence and severity of hypoglycaemia can be reduced through use of rtCGM in these individuals. Methods The HypoDE study was a 6-month, multicentre, open-label, parallel, randomised controlled trial done at 12 diabetes practices in Germany. Eligible participants had type 1 diabetes and a history of impaired hypoglycaemia awareness or severe hypoglycaemia during the previous year. All participants wore a masked rtCGM system for 28 days and were then randomly assigned to 26 weeks of unmasked rtCGM (Dexcom G5 Mobile system) or to the control group (continuing with self-monitoring of blood glucose). Block randomisation with 1:1 allocation was done centrally, with the study site as the stratifying variable. Masking of participants and study sites was not possible. Control participants wore a masked rtCGM system during the follow-up phase (weeks 22-26). The primary outcome was the baseline-adjusted number of hypoglycaemic events (defined as glucose ≤3·0 mmol/L for ≥20 min) during the follow-up phase. The full dataset analysis comprised participants who wore the rtCGM system during the baseline and follow-up phases. The intention-to-treat analysis comprised all randomised participants. This trial is registered with ClinicalTria…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“CGM can reveal asymptomatic hypoglycemia and help identify patterns and precipitants of hypoglycemic events and provide alarms that can warn individuals of falling glucose so that they can intervene (150,151).”
From 6. Glycemic Goals, Hypoglycemia, and Hyperglycemic Crises: Standards of Care in Diabetes-2026. (2026) · cites this paper as [150]
In the citing paper
“Several clinical trials have not shown a reduction of IAH by using CGM despite a reduced incidence of level 3 hypoglycemia (101,112,124,126-128).”
In the citing paper
“Hypoglycemia with glucose levels below 3.0 mmol/L (54 mg/dL) occurs much more often than previously appreciated (46,101).”
In the citing paper
“Reductions in HbA1c have been reported with CGM use in people on multiple daily injection (MDI) therapy,19 and continuous subcutaneous insulin infusion therapy,20 with reduced time spent in hypoglycemia,20 and improved hypoglycemia awareness.21”
From Increased Time in Range and Fewer Missed Bolus Injections After Introduction of a Smart Connected Insulin Pen (2020) · cites this paper as [21]
In the citing paper
“The leading CGMs on market today are Dexcom (CA, USA), Medtronic (MN, USA) and Abbott (IL, USA) devices [2-5,19,31].”
From Wearables and the Medical Revolution (2018) · cites this paper as [19]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Self-citationBeck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Hypoglycemia in the Diabetes Control and Complications Trial
The Diabetes Control and Complications Trial Research Group (1997) · Diabetes · doi:10.2337/diab.46.2.271 · Cited by 746
Lind, M., Polonsky, W., Hirsch, I. B., Heise, T., Bolinder, J., Dahlqvist, S., Schwarz, E., Ólafsdóttir, A. F., Frid, A., Wedel, H., et al. (2017) · JAMA · doi:10.1001/jama.2016.19976 · Cited by 705
Clarke, W. L., Cox, D. J., Gonder-Frederick, L. A., Julian, D., Schlundt, D., & Polonsky, W. (1995) · Diabetes Care · doi:10.2337/diacare.18.4.517 · Cited by 651
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
the SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493
Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 Diabetes
Battelino, T., Phillip, M., Bratina, N., Nimri, R., Oskarsson, P., & Bolinder, J. (2011) · Diabetes Care · doi:10.2337/dc10-1989 · Cited by 490
Hypoglycaemia in diabetes mellitus: epidemiology and clinical implications
Frier, B. M. (2014) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2014.170 · Cited by 481
Cited by
Items 401–500 of 528
Jahed, S. A., Nikoosokhan, A., Moravej, H., Sarkheil, P., Malek, M., Esteghamati, A., Hosseinpanah, F., & Sedaghat, S. (2025) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2025.112961 · Cited by 1
Digital Healing for Diabetic Disabilities: Tools for Monitoring, Mobility, and Self-Management
Adhikary, K., Ganguly, K., Maity, M. D., Mahata, P., & Samson, O. J. (2026) · Springer eBooks · doi:10.1007/978-981-95-8946-3_12 · Cited by 3
2023 Clinical Practice Guidelines for Diabetes: Continuous Glucose Monitoring and Insulin Pumps
Jin, S. (2023) · Journal of Korean Diabetes · doi:10.4093/jkd.2023.24.3.141 · Cited by 2
“이는 1형당뇨병 성인을 대상으로 당화혈색소 감소를 일 차결과지표로 했던 무작위대조연구 8개[1-8]와 저혈당 감소 를 일차결과지표로 했던 무작위대조연구 7개[9-15] 중, 소득 수준이 낮은 1형당뇨병 성인들을 대상으로 교육이 충분히 제 공되지 않은 1개의 무작위대조연구[4]를 제외하면 모두 유 의한 결과를 얻었기 때문이다.”
Health and biosensor technology—A revolution underway for the well-being of the population
Bastidas, G. A., & Iglesias, R. (2024) · Wearable Technology · doi:10.54517/wt.v4i1.2618 · Cited by 4
Li, Y., Wang, B., Xu, M.-T., Wang, Y., Liu, W.-Q., Fu, S.-J., Li, B., Ling, H., Liu, X.-T., Zhang, X., et al. (2025) · World Journal of Diabetes · doi:10.4239/wjd.v16.i2.97271 · Cited by 3
Continuous Glucose Monitors: A Guide for Primary Care Clinicians
Solano, L. (2025) · CRC Press eBooks · doi:10.1201/9781003656180 · Cited by 1
Gizem, U. Z. L. U., & Demır, H. P. (2025) · Nutrition and Health · doi:10.1177/02601060251384724 · Cited by 1
Nascimento, S. Q., Brito‐Pereira, R., Polícia, R., Lanceros-Méndez, S., & Crespilho, F. N. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.118970 · Cited by 1
The beginning of the end of fingersticks?
Song, M. Y., Steinhubl, S. R., & Topol, E. J. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31576-9 · Cited by 1
Out-of-Hospital Management of Diabetic Emergencies in Germany: Structural and Process Quality
Holstein, D. J. F., Holstein, J. D., Fischer, D., Mende, M., Frier, B. M., & Holstein, A. (2021) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/a-1523-7562 · Cited by 1
Nursing interventions for people with type 1 diabetes and frequent hypoglycaemia
Kelly, B. (2021) · British Journal of Community Nursing · doi:10.12968/bjcn.2021.26.11.544 · Cited by 2
A review of diabetes management tools and applications
Shahriar, H., Sneha, S., Abaye, Y., Hashmi, T., Wilson, S., & Usen, U. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-99031-8.00023-5 · Cited by 1
Nontraditional Uses of Continuous Glucose Monitoring
Kapsar, P., Chao, C., & Walker, T. C. (2022) · The Journal for Nurse Practitioners · doi:10.1016/j.nurpra.2022.06.013 · Cited by 1
Il monitoraggio in continuo della glicemia: stato dell’arte
Irace, C., & Molfetta, S. D. (2022) · il Diabete · doi:10.30682/ildia2204g · Cited by 1
Neural Stem Cell-based Regenerative Therapy: A New Approach to Diabetes Treatment
Sharma, K., Puranik, N., & Yadav, D. (2023) · Endocrine Metabolic & Immune Disorders - Drug Targets · doi:10.2174/1871530323666230512121416 · Cited by 1
Salasa, W., Seredyński, T., Mądry, W., Mazurkiewicz, A., Kołodziej, M., Męczyńska, J., Saiuk, N., Kozicz, M. A., Wojciechowska, A., & Marcicka, J. (2024) · Journal of Education Health and Sport · doi:10.12775/jehs.2024.67.50885 · Cited by 1
McCoy, R. G. (2024) · Diabetes Metabolic Syndrome and Obesity · doi:10.2147/dmso.s491642 · Cited by 1
Gölz, S., Mader, J. K., Bilz, S., Kenzler, J., & Danne, T. (2024) · Diabetes Therapy · doi:10.1007/s13300-024-01670-y · Cited by 1
Dynamic Interference Testing Results with the Dexcom G6 Continuous Glucose Monitoring Device
Thomé, N., Jensch, H., Srikanthamoorthy, G., Weingärtner, L., Grady, M., Setford, S. J., Holt, E., & Pfützner, A. (2025) · Diabetes Technology and Obesity Medicine · doi:10.1089/dtom.2024.0009 · Cited by 1
Gera, S., Rearson, A., Gallop, R., & Marks, B. E. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2025.0173 · Cited by 1
Digitale Situation in Diabeteskliniken
Stockmann, C., & Stirban, O. A. (2018) · Der Diabetologe · doi:10.1007/s11428-018-0378-z · Cited by 1
Relevancia del monitoreo continuo de glucosa en la práctica clínica: revisión de la evidencia
Gómez, A. M., Carrillo, D. C. H., Tapoada, L., & Toro, M. R. (2018) · Revista Colombiana de Endocrinología Diabetes & Metabolismo · doi:10.53853/encr.5.3.432 · Cited by 3
Should all patients on insulin be using continuous glucose monitoring?
Distiller, L. A. (2018) · Journal of Endocrinology Metabolism and Diabetes of South Africa · doi:10.1080/16089677.2018.1515164 · Cited by 1
“The efficacy of RT-CGM in reducing hypoglycaemia in patients with severe hypoglycaemia unawareness has recently been confirmed.(19)”
BackgroundSteenkamp, D. (2019) · Endocrine Practice · doi:10.4158/ep-2019-0100 · Cited by 1
Garden, G. L., Hunt, D. W., Mackie, K., Tuthill, B., Griffith, H., Russell-Jones, D. L., & Herring, R. A. (2021) · British Journal of Diabetes · doi:10.15277/bjd.2021.284 · Cited by 1
L'insulinothérapie au xxie siècle : une symphonie de plus en plus harmonieuse
Benhamou, P., Hanaire, H. P., & Renard, É. (2021) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(21)00179-6 · Cited by 1
Grassi, B. A., Caramés, B., Plaza‐Plaza, J. C., Onetto, M. T., Moreno, S., Sandoval, T., Tapia, N., Salas, F. M., & Revello, A. (2022) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2022.108262 · Cited by 1
Predictors of change in hypoglycemia unawareness among patients with type 1 diabetes
Melnychuk, J., Wyne, K. L., & Dungan, K. M. (2022) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.3582 · Cited by 1
Kaur, R. J., Rizvi, S., & Kudva, Y. C. (2021) · Wiley eBooks · doi:10.1002/9781119603207.ch9 · Cited by 1
Paponette, B., Keaver, L., Lynch, P. M., Eltoum, E., Clarke, L., Carty, J., Bacon, S., & McHugh, C. (2025) · Endocrine Abstracts · doi:10.1530/endoabs.115.ep13 · Cited by 3
Soloway, B. (2018) · Journal watch · doi:10.1056/nejm-jw.na46190
Digitale Tools und strukturierte Prozesse verbessern Therapiequalität
Eiden, P. (2018) · Info Diabetologie · doi:10.1007/s15034-018-1325-1
Prise en charge du diabète instable : approche humaine ou technologique ?
Benhamou, P. (2018) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(18)30095-6
Pintaudi, B., Bertuzzi, F., Gironi, I., Mion, E., Disoteo, O., Pizzi, G., Pani, A., & Bonomo, M. A. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819848685
Latres, E. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814831-0.00036-1
Kulzer, B., & Hermanns, N. (2019) · Diabetologie und Stoffwechsel · doi:10.1055/a-0947-2833
“Durch den Einsatz von CGM bei Patienten mit Hypoglyxkämieproblemen konnten diese schweren Hypoglykämien und ebenso die Zeit im hypoglykämischen Bereich signifikant reduziert werden konnten [23, 24].”
BackgroundSelf-citationHypoglykämien bei Diabetes mellitus: häufig und gefährlich
Holstein, A., & Holstein, D. J. F. (2019) · Diabetes aktuell · doi:10.1055/a-1031-2237
Labunets, I. F., Rodnichenko, A. E., & Panteleymonova, T. (2019) · Fìzìologìčnij žurnal · doi:10.15407/fz65.05.003
Kontinuierliche Gewebezuckermessung beantragen – Schritt für Schritt
Schlüter, S. (2020) · Diabetologie und Stoffwechsel · doi:10.1055/a-0973-2077
“Diabetes Care 2019; 42: 1593–1603 [13] Heinemann L, Freckmann G, Ehrmann D et al.”
BackgroundПерцева, Н. О., & Moshenets, K. I. (2021) · INTERNATIONAL JOURNAL OF ENDOCRINOLOGY (Ukraine) · doi:10.22141/2224-0721.16.1.2020.199124 · Cited by 1
Uduku, C. N., Reddy, M., & Oliver, N. S. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816714-4.00007-7
Methoden der Stoffwechselkontrolle – HbA1c versus „time in range“
Freckmann, G., Buck, S., Waldenmaier, D., & Haug, C. (2021) · Der Diabetologe · doi:10.1007/s11428-021-00730-2
Self-citationSchlüter, S., Freckmann, G., Wernsing, M., Rölver, K., Jördening, M., Holder, M., Heinemann, L., & Lange, K. (2021) · Diabetologie und Stoffwechsel · doi:10.1055/a-1492-5294
Self-citationDiagnosis and Management of Pediatric Diseases
Sergi, C. M. (2019) · MDPI eBooks · doi:10.3390/books978-3-03921-967-4
Living with type 1 diabetes: what really matters?
Wilmot, E. G. (2021) · Practical Diabetes · doi:10.1002/pdi.2352
Clinical and economic benefits of continuous blood glucose monitoring devices
Rahman, R. S., Salamah, H. E., Alshair, F. M., Alsawadi, A. A., Alghamdi, O. M., Alalasi, A. B., Mufarrihi, A. M., Alalawi, A. O., Alzahrani, O. M., Alanazi, H. O., et al. (2022) · International Journal of Community Medicine and Public Health · doi:10.18203/2394-6040.ijcmph20220053
“0001).(13) It has been further shown that CGM devices might also enhance the therapeutic responses and related outcomes of patients receiving different insulin formulations and other antidiabetic modalities.”
BackgroundOliver, N. S. (2022) · Diabetic Medicine · doi:10.1111/dme.14782
Glucose Monitoring and Sensing
Pickup, J. C., & Oliver, N. S. (2022) · doi:10.1093/med/9780198870197.003.0251 · Cited by 1
Oliver, N. S. (2021) · Diabetic Medicine · doi:10.1111/dme.14579
A New Term for Estimating HbA1c by Continuous Glucose Monitoring: Glucose Management Indicator (GMI)
胡, 坤. (2021) · Advances in Clinical Medicine · doi:10.12677/acm.2021.1111714 · Cited by 1
Suganuma, Y., Takahashi, H., & Nishimura, R. (2022) · Diabetology International · doi:10.1007/s13340-022-00585-y
A folyamatos glükózmonitorozás jelentősége a korszerű diabetesgondozásban
Kocsis, G. (2022) · Lege Artis Medicinae · doi:10.33616/lam.32.016
Akutkomplikationen des Diabetes mellitus – Schulungsinhalte richtig vermitteln
Ehrmann, D. (2022) · Diabetologie und Stoffwechsel · doi:10.1055/a-1723-5181
Self-citationSakane, N., Kato, K., Hata, S., Nishimura, E., Araki, R., Kouyama, K., Hatao, M., Matoba, Y., Matsushita, Y., Domichi, M., et al. (2022) · Research Square · doi:10.21203/rs.3.rs-1984365/v1
Waldenmaier, D., Buck, S., Pleus, S., Beltzer, A., Schauer, S., Link, M., Zschornack, E., Jendrike, N. R. M., Haug, C., & Freckmann, G. (2022) · Research Square · doi:10.21203/rs.3.rs-1992681/v1
Self-citationHellmund, R., & Welsh, Z. (2022) · Diabetic Medicine · doi:10.1111/dme.14988
Academy™: An Online Diabetes Educational Programme for Healthcare Professionals
Taylor, J. (2022) · EMJ Diabetes · doi:10.33590/emj/22c0070
The Use of Diabetes Technology in Persons with Diabetes and Coronavirus 2019
Szmuilowicz, E. D., & Aleppo, G. (2023) · Contemporary Endocrinology · doi:10.1007/978-3-031-28536-3_11
Saxena, R. K., Singh, A. B., & .Singh, N. P. (2023) · International Journal of Life Science and Pharma Research · doi:10.22376/ijlpr.2023.13.4.sp6.l87-l99
Oliver, N. S. (2023) · Diabetic Medicine · doi:10.1111/dme.15176
Does sensor technology lower the prevalence of impaired hypoglycaemia awareness in type 1 diabetes?
Song, S. H., & Frier, B. M. (2023) · Diabetic Medicine · doi:10.1111/dme.15185
NUOLATINIŲ GLIUKOZĖS JUTIKLIŲ PRITAIKYMAS SERGANTIEMS NE TIK CUKRINIU DIABETU
Bakutis, J. (2023) · Health Sciences · doi:10.35988/sm-hs.2023.181
Minimizing Hypoglycemia with Insulin Therapy: The “THINK” Strategy
Priya, G., & Grewal, E. (2022) · Chronicle of Diabetes Research and Practice · doi:10.4103/cdrp.cdrp_9_22
Schwere Hypoglykämie und diabetische Ketoazidose: Warnung erwünscht
Thomas, A. (2023) · Info Diabetologie · doi:10.1007/s15034-023-4545-y
Zozulińska‐Ziółkiewicz, D., Malecki, M. T., Czupryniak, L., Jarosz-Chobot, P. A., Klupa, T., Myśliwiec, M., Szadkowska, A., Szypowska, A., Gawrecki, A., Mianowska, B., et al. (2021) · Current Topics in Diabetes · doi:10.5114/ctd/146220
Diabetestechnik: Vom Pieksen über das Monitoring zum Closed Loop
Berwinkel, S., & Flohr, F. (2023) · Ernährung & Medizin · doi:10.1055/a-2100-0336
Gupta, R., Edupuganti, S., Zamir, I., Singh, A., & Thawani, H. (2023) · Cureus · doi:10.7759/cureus.49141
“…helps in optimizing their insulin regimen and avoiding episodes of hypoglycemia which can be readily achieved by CGM. Studies have demonstrated that the use of CGM provides the greatest glycemic benefit and improves safety in patients with nocturnal hypoglycemia and hypoglycemic unawareness [8].”
BackgroundMerino, M., Hidalgo‐Vega, Á., Anzola, S. C., Sarría‐Santamera, A., Baro, M. A., Romero, J. M. G., Merino-Torres, J. F., Serra, O. D. S.-M., & Beato-Víbora, P. I. (2021) · Economía de la Salud · doi:10.61679/1602023041
Haemoglobin glycation index (HGI) as a marker of individual glycation in diabetes
Pehr, M., & Škrha, J. (2023) · Vnitřní lékařství · doi:10.36290/vnl.2023.097
Smart Insulin Pen: Managing Insulin Therapy for People with Diabetes in the Digital Era
Yoo, J. H., & Kim, J. H. (2023) · Journal of Korean Diabetes · doi:10.4093/jkd.2023.24.4.190
Iqbal, A., Chow, E., Jones, T. W., & Heller, S. R. (2024) · Wiley eBooks · doi:10.1002/9781119697473.ch40
Данилова, Л. И., Короленко, Г. Г., Lushchik, M. L., Романовский, А. А., Бурко, И. И., & Исачкина, О. Н. (2023) · Рецепт · doi:10.34883/pi.2023.26.5.014
Traiter les hypoglycémies iatrogènes à l’ère des nouvelles technologies
Monnier, L., & Colette, C. (2024) · Médecine des Maladies Métaboliques · doi:10.1016/j.mmm.2024.02.002
Stars and Rising Stars in Pediatric Endocrinology: 2022
(2024) · Frontiers research topics · doi:10.3389/978-2-8325-4686-4
Zhang, D., Yang, Y., Zhang, J., Chen, J., Huang, L., Zhang, L., & Liu, X. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4791181
Comité de Innovación. Uso de los sistemas de infusión continua de insulina en personas con DM1
Carnero, R., Saleme, A., Lequi, L., Daín, A., Campos, F. S., Sosa, L., Flores, A., & Kabakian, L. (2024) · Revista de la Sociedad Argentina de Diabetes · doi:10.47196/diab.v58i1sup.763 · Cited by 1
Quelle place pour la greffe d’îlots à l’ère de la boucle fermée ?
Benhamou, P. (2024) · Médecine des Maladies Métaboliques · doi:10.1016/j.mmm.2024.04.009
Lameijer, A. (2024) · University of Groningen research database (University of Groningen / Centre for Information Technology) · doi:10.33612/diss.1021051970
Pérez-López, P. (2024) · UVaDOC UVaDOC University of Valladolid Documentary Repository (University of Valladolid) · doi:10.35376/10324/68548
Lablanche, S., Reach, G., Guerci, B., Sola‐Gazagnes, A., Meyer, L., Hanaire, H. P., Riveline, J., & Joubert, M. (2024) · Médecine des Maladies Métaboliques · doi:10.1016/j.mmm.2024.07.004
Steenkamp, D. (2021) · American Diabetes Association eBooks · doi:10.2337/9781580407694.ch07
Patient Selection, Clinical Considerations, and Intensive Diabetes Management Goals
Steenkamp, D. (2021) · American Diabetes Association eBooks · doi:10.2337/9781580407694.ch05
Tecnología aplicada a la diabetes
Cebada, A. B., Silva, J. B. Q., Escobar-Morreale, H. F., & Chávez, L. N. (2024) · Medicine - Programa de Formación Médica Continuada Acreditado · doi:10.1016/j.med.2024.10.004
Impacto del inicio de la monitorización flash de glucosa en pacientes adultos con diabetes tipo 1
Sahagún, R. J. (2024) · UVaDOC UVaDOC University of Valladolid Documentary Repository (University of Valladolid) · doi:10.35376/10324/72390
(2022) · American Diabetes Association eBooks · doi:10.2337/9781580407700.ch04
Case Report: Hybrid closed-loop insulin pump can significantly improve awareness of hypoglycemia
Zadáková, E., & Horová, E. (2025) · Frontiers in Clinical Diabetes and Healthcare · doi:10.3389/fcdhc.2025.1536038
Aljohani, R. A., Altaib, H. N., & Kofi, M. A. (2025) · Cureus · doi:10.7759/cureus.79705 · Cited by 2
“In addition, CGM is useful in guiding treatment decisions, such as adjusting treatment regimens and optimizing insulin dosing strategies [15,16].”
Li, S., Shan, X., Wei, X., Dai, W., & Cao, Y. (2025) · Diabetology & Metabolic Syndrome · doi:10.1186/s13098-025-01794-6 · Cited by 1
“The HypoDE study demonstrated that hypoglycemia awareness scores in the whole cohort also improved by 40% with the use of CGM [44]which may suggest that the combination of CGM and assessment of autonomic function by clinical practitioners, early identification of high-risk patients, and…”
Stout, H. K., Planas, L. G., Sewell, H. E., Nadig, A. P., & O’Neal, K. S. (2025) · ADCES in Practice · doi:10.1177/2633559x251366099
Dervişoğlu, M., Günbaş, M., & Besen, D. B. (2025) · The Science of Diabetes Self-Management and Care · doi:10.1177/26350106251371082
Medications for the Management of Hypoglycemia
Giruzzi, M. E. (2025) · American Diabetes Association eBooks · doi:10.2337/9781580408462-ch28
Jiang, H., Henley, D., & Jiang, F. (2025) · World Journal of Transplantation · doi:10.5500/wjt.v15.i4.101926
“The artificial pancreas showed superior glycaemic control, with less hypoglycaemic episodes, compared to conventional multiple daily injections in diabetic patients[31,32].”
Schwere Hypoglykämie – ein ungelöstes Problem
Waxenegger, C. (2025) · Info Diabetologie · doi:10.1007/s15034-025-5200-6
Graña, C., Ravaud, P., Ghosn, L., & Tran, V.-T. (2020) · Figshare · doi:10.6084/m9.figshare.13199052
Diyabetli Bireylerin Diyabet Teknolojilerine Yönelik Bilgi ve Uygulamalarının Değerlendirilmesi
BİÇER, E. K. (2025) · Turkish Journal of Diabetes Nursing · doi:10.29228/tjdn.81962
Guía de práctica clínica sobre Diabetes Mellitus Tipo 1
(2026) · GuíaSalud eBooks · doi:10.46995/gpc_659
Impaired awareness of hypoglycemia: can structured education address this persistent challenge?
Yuanyuan, C. H. E. N., He, X., Shan, Y., & Lan, M. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1722045
AI for monitoring clinical outcomes and adverse events
Hamid, S., Ali, R., Khanna, K., & Raza, K. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-44430-2.00002-5
Daultrey, H. E., Oliver, N. S., Chakera, A. J., Libardi, A. D. L. C., Iwuji, C. C., & Gasparrini, A. (2026) · Diabetes Care · doi:10.2337/dc25-2383 · Cited by 1
Metadata
- Authors
- Heinemann, L., Freckmann, G., Ehrmann, D., Faber-Heinemann, G., Guerra, S., Waldenmaier, D., & Hermanns, N.
- Affiliations
- Universität Ulm (DE)
- Forschungsinstitut der Diabetes Akademie Mergentheim (DE)
- Dexcom (United States) (US)
- Corresponding author
- Hermanns, Norbert
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2018-04
- Volume
- 391
- Issue
- 10128
- Pages
- 1367-1377
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2786804638
- Cited by
- 522
- References
- 30
- Citations by year
- 2026: 33 · 2025: 49 · 2024: 75 · 2023: 65 · 2022: 73 · 2021: 73 · 2020: 62 · 2019: 63 · 2018: 28
- FWCI
- 44.97
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Dexcom
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- real-time continuous glucose monitoring, type 1 diabetes, hypoglycemia, severe hypoglycemia, multiple daily insulin injections, hypoglycemia prevention, self-monitoring of blood glucose, adults with diabetes
- MeSH terms
- Adult, Awareness, Blood Glucose, Diabetes Mellitus, Type 1, Drug Administration Schedule, Female, Follow-Up Studies, Humans, Hypoglycemia, Hypoglycemic Agents, Injections, Subcutaneous, Insulin, Male, Middle Aged, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.