Biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents in patients with ST-segment elevation myocardial infarction (BIOSTEMI): a single-blind, prospective, randomised superiority trial
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
BACKGROUND Newer-generation drug-eluting stents that combine ultrathin strut metallic platforms with biodegradable polymers might facilitate vascular healing and improve clinical outcomes in patients with acute myocardial infarction undergoing primary percutaneous coronary intervention (PCI) compared with contemporary thin strut second-generation drug-eluting stents. We did a randomised clinical trial to investigate the safety and efficacy of ultrathin strut biodegradable polymer sirolimus-eluting stents versus thin strut durable polymer everolimus-eluting stents in patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary PCI. METHODS The BIOSTEMI trial was an investigator-initiated, multicentre, prospective, single-blind, randomised superiority trial at ten hospitals in Switzerland. Patients aged 18 years or older with acute STEMI who were referred for primary PCI were eligible to participate. Patients were randomly allocated (1:1) to either biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Central randomisation was done based on a computer-generated allocation sequence with variable block sizes of 2, 4, and 6, which was stratified by centre, diabetes status, and presence or absence of multivessel coronary artery disease, and concealed using a secure web-based system. Patients and treating physicians were aware of group allocations, whereas outcome assessors were masked to the allocated stent. The experimental stent (Orsiro; Biotronik; Bülach, Switzerland) consisted of an ultrathin strut cobalt-chromium metallic stent platform releasing sirolimus from a biodegradable polymer. The control stent (Xience Xpedition/Alpine; Abbott Vascular, Abbott Park, IL, USA) consisted of a thin strut cobalt-chromium stent platform that releases everolimus from a durable polymer. The primary endpoint was target lesion failure, a composite of cardiac death, target vessel myocardial reinfarction (Q-wave and non-Q-wave), and clinically-indicated target lesion revascularisation, within 12 months of the index procedure. All analyses were done with the individual participant as the unit of analysis and according to the intention-to-treat principle. The trial was registered with ClinicalTrials.gov, number NCT02579031. FINDINGS Between April 26, 2016, and March 9, 2018, we randomly assigned 1300 patients (1623 lesions) with acute myocardial infarction to treatment with biodegradable polymer sirolimus-eluting stents (649 patients and 816 lesions) or durable polymer everolimus-eluting stents (651 patients and 806 lesions). At 12 months, follow-up data were available for 614 (95%) patients treated with biodegradable polymer sirolimus-eluting stents and 626 (96%) patients treated with durable polymer everolimus-eluting stents. The primary composite endpoint of target lesion failure occurred in 25 (4%) of 649 patients treated with biodegradable polymer sirolimus-eluting stents and 36 (6%) of 651 patients treated with durable polymer everolimus-eluting stents (difference -1·6 percentage points; rate ratio 0·59, 95% Bayesian credibility interval 0·37-0·94; posterior probability of superiority 0·986). Cardiac death, target vessel myocardial reinfarction, clinically-indicated target lesion revascularisation, and definite stent thrombosis were similar between the two treatment groups in the 12 months of follow-up. INTERPRETATION In patients with acute STEMI undergoing primary PCI, biodegradable polymer sirolimus-eluting stents were superior to durable polymer everolimus-eluting stents with respect to target lesion failure at 1 year. This difference was driven by reduced ischaemia-driven target lesion revascularisation in patients treated with biodegradable polymer sirolimus-eluting stents compared with durable polymer everolimus-eluting stents. FUNDING Biotronik.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ibanez, B., James, S., Agewall, S., Antunes, M. J., Bucciarelli-Ducci, C., Bueno, H., Caforio, A. L. P., Crea, F., Goudevenos, J. A., Halvorsen, S., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx393 · Cited by 9,728
Self-citationKastrati, A., Mehilli, J., Dirschinger, J., Dotzer, F., Schühlen, H., Neumann, F.-J., Fleckenstein, M., Pfafferott, C., Seyfarth, M., & Schömig, A. (2001) · Circulation · doi:10.1161/01.cir.103.23.2816 · Cited by 938
Kolandaivelu, K., Swaminathan, R., Gibson, W. J., Kolachalama, V. B., Nguyen-Ehrenreich, K.-L., Giddings, V. L., Coleman, L., Wong, G. K., & Edelman, E. R. (2011) · Circulation · doi:10.1161/circulationaha.110.003210 · Cited by 802
Windecker, S., Serruys, P. W., Wandel, S., Buszman, P., Trznadel, S., Linke, A., Lenk, K., Ischinger, T., Klauss, V., Eberli, F., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61244-1 · Cited by 653
Self-citationNakazawa, G., Finn, A. V., Joner, M., Ladich, E., Kutys, R., Mont, E. K., Gold, H. K., Burke, A. P., Kolodgie, F. D., & Virmani, R. (2008) · Circulation · doi:10.1161/circulationaha.107.762047 · Cited by 611
Pache, J. Ü., Kastrati, A., Mehilli, J., Schühlen, H., Dotzer, F., Hausleiter, J. Ö., Fleckenstein, M., Neumann, F.-J., Sattelberger, U., Schmitt, C., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00119-0 · Cited by 557
Sabate, M., Cequier, A., Iñiguez, A., Serra, A., Hernandez-Antolin, R., Mainar, V., Valgimigli, M., Tespili, M., den Heijer, P., Bethencourt, A., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61223-9 · Cited by 462
Self-citationBangalore, S., Toklu, B., Patel, N., Feit, F., & Stone, G. W. (2018) · Circulation · doi:10.1161/circulationaha.118.034456 · Cited by 309
Räber, L., Kelbæk, H., Ostojic, M., Baumbach, A., Heg, D., Tüller, D., von Birgelen, C., Roffi, M., Moschovitis, A., Khattab, A. A., et al. (2012) · JAMA · doi:10.1001/jama.2012.10065 · Cited by 298
Self-citationVranckx, P., Cutlip, D. E., Mehran, R., Kint, P.-P., Silber, S., Windecker, S., & Serruys, P. W. J. C. (2010) · EuroIntervention · doi:10.4244/eijv5i7a146 · Cited by 281
Self-citationKandzari, D. E., Mauri, L., Koolen, J. J., Massaro, J. M., Doros, G., Garcia-Garcia, H. M., Bennett, J., Roguin, A., Gharib, E. G., Cutlip, D. E., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32249-3 · Cited by 279
Pilgrim, T., Heg, D., Roffi, M., Tüller, D., Muller, O., Vuilliomenet, A., Cook, S., Weilenmann, D., Kaiser, C., Jamshidi, P., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)61038-2 · Cited by 267
Self-citationvon Birgelen, C., Kok, M. M., van der Heijden, L. C., Danse, P. W., Schotborgh, C. E., Scholte, M., Gin, R. M. T. J., Somi, S., van Houwelingen, K. G., Stoel, M. G., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31920-1 · Cited by 250
Piccolo, R., Bonaa, K. H., Efthimiou, O., Varenne, O., Baldo, A., Urban, P., Kaiser, C., Remkes, W., Räber, L., de Belder, A., et al. (2019) · The Lancet · doi:10.1016/s0140-6736(19)30474-x · Cited by 234
Self-citationAli, Z. A., Serruys, P. W., Kimura, T., Gao, R., Ellis, S. G., Kereiakes, D. J., Onuma, Y., Simonton, C., Zhang, Z., & Stone, G. W. (2017) · The Lancet · doi:10.1016/s0140-6736(17)31470-8 · Cited by 204
Sabaté, M., Brugaletta, S., Cequier, A., Iñiguez, A., Serra, A., Jiménez-Quevedo, P., Mainar, V., Campo, G., Tespili, M., den Heijer, P., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(15)00548-6 · Cited by 198
Self-citationKalesan, B., Pilgrim, T., Heinimann, K., Räber, L., Stefanini, G. G., Valgimigli, M., da Costa, B. R., Mach, F., Lüscher, T. F., Meier, B., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs036 · Cited by 142
Self-citationStent Thrombosis in New-Generation Drug-Eluting Stents in Patients With STEMI Undergoing Primary PCI
Sarno, G., Lagerqvist, B., Nilsson, J., Fröbert, O., Hambræus, K., Varenhorst, C., Jensen, U. J., Tödt, T., Götberg, M., & James, S. K. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.022 · Cited by 122
Bangalore, S., Amoroso, N. S., Fusaro, M., Kumar, S., & Feit, F. (2013) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.113.000415 · Cited by 87
Räber, L., Yamaji, K., Kelbæk, H., Engstrøm, T., Baumbach, A., Roffi, M., von Birgelen, C., Taniwaki, M., Moschovitis, A., Zaugg, S., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz074 · Cited by 47
Self-citationA united interpretation of different uncertainty intervals
Willink, R., & Lira, I. H. (2005) · Measurement · doi:10.1016/j.measurement.2005.01.001 · Cited by 35
Cited by
Kim, B.-K., Hong, S.-J., Cho, Y.-H., Yun, K. H., Kim, Y. H., Suh, Y., Cho, J. Y., Her, A.-Y., Cho, S., Jeon, D. W., et al. (2020) · JAMA · doi:10.1001/jama.2020.7580 · Cited by 588
Metadata
- Authors
- Iglesias, J. F., Muller, O., Heg, D., Roffi, M., Kurz, D. J., Moarof, I., Weilenmann, D., Kaiser, C., Tapponnier, M., Stortecky, S., Losdat, S., Eeckhout, E., Valgimigli, M., Odutayo, A., Zwahlen, M., Jüni, P., Windecker, S., & Pilgrim, T.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2019-10
- Volume
- 394
- Issue
- 10205
- Pages
- 1243-1253
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2970737263
- Cited by
- 188
- References
- 21
- FWCI
- 24.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.