STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 12,701–12,800 of 47,868
Assessing ocular bulbar redness: a comparison of methods
Downie, L. E., Keller, P. R., & Vingrys, A. J. (2015) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12245 · Cited by 39
Beuzit, L., Eliat, P., Brun, V., Ferré, J., Gandon, Y., Bannier, É., & Saint‐Jalmes, H. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25101 · Cited by 39
Kim, E. J., de Oca, I. M., Wang, L., Weikert, M. P., Koch, D. D., & Khandelwal, S. S. (2015) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2015.07.035 · Cited by 39
Investigation of association between hip morphology and prevalence of osteoarthritis
Zeng, W., Wang, F.-Y., Chen, C., Zhang, Y., Gong, X.-Y., Zhou, K., Chen, Z., Wang, D., Zhou, Z.-K., & Yang, L. (2016) · Scientific Reports · doi:10.1038/srep23477 · Cited by 44
Acker, N. V., Ragé, M., Sluydts, E., Knaapen, M., de Bie, M., Timmers, M., Fransén, E., Duymelinck, C., Schepper, S. D., Anand, P., et al. (2016) · BMC Research Notes · doi:10.1186/s13104-016-2085-4 · Cited by 41
Bobbia, X., Clément, A., Claret, P. G., Bastide, S., Alonso, S., Wagner, P., Tison, T., Müller, L., & Coussaye, J. E. D. L. (2016) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2016.05.055 · Cited by 39
A simplified thermoregulation model of the human body in warm conditions
Li, B., Yang, Y., Yao, R., Liu, H., & Li, Y. (2016) · Applied Ergonomics · doi:10.1016/j.apergo.2016.09.010 · Cited by 39
Harmonic sum-based method for heart rate estimation using PPG signals affected with motion artifacts
Dubey, H., Kumaresan, R., & Mankodiya, K. (2016) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-016-0422-z · Cited by 41
Verger, E. O., Armstrong, P., Nielsen, T., Chakaroun, R., Aron‐Wisnewsky, J., Gøbel, R. J., Schütz, T., Delaere, F., Gausserès, N., Clément, K., et al. (2016) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2016.10.030 · Cited by 50
Does Extremely Low Birth Weight Predispose to Low-Renin Hypertension?
Raaijmakers, A., Zhang, Z., Claessens, J., Cauwenberghs, N., van Tienoven, T. P., Wei, F., Jacobs, L., Levtchenko, E. N., Pauwels, S., Kuznetsova, T., et al. (2017) · Hypertension · doi:10.1161/hypertensionaha.116.08643 · Cited by 45
A Study of the Validity of Two Exposure Assessment Tools: Stoffenmanager and the Advanced REACH Tool
Landberg, H. E., Axmon, A., Westberg, H., & Tinnerberg, H. (2017) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxx008 · Cited by 41
Tennfjord, M. K., Engh, M. E., & Bø, K. (2017) · International Urogynecology Journal · doi:10.1007/s00192-017-3290-y · Cited by 43
Real-Time Gait Event Detection Based on Kinematic Data Coupled to a Biomechanical Model †
Lambrecht, S., Harutyunyan, A., Tanghe, K., Afschrift, M., Schutter, J. D., & Jonkers, I. (2017) · Sensors · doi:10.3390/s17040671 · Cited by 42
Park, J. Y., Foley, T. A., Bonnichsen, C. R., Maurer, M. J., Goergen, K. M., Nkomo, V. T., Enriquez-Sarano, M. L., Williamson, E. E., & Michelena, H. I. (2017) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.03.006 · Cited by 39
Intra-observer reliability and agreement of manual and digital orthodontic model analysis
Koretsi, V., Tingelhoff, L., Proff, P., & Kirschneck, C. (2017) · European Journal of Orthodontics · doi:10.1093/ejo/cjx040 · Cited by 51
Fu, X., Peng, C. C., Li, Z., Liu, S., Tan, M., & Song, J. (2017) · PLoS ONE · doi:10.1371/journal.pone.0178858 · Cited by 39
Strabismus Measurements with Novel Video Goggles
Weber, K. P., Rappoport, D., Dysli, M., Meier, T. S., Marks, G. B., Bockisch, C. J., Landau, K., & MacDougall, H. G. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2017.06.020 · Cited by 39
A microfluidic approach for hemoglobin detection in whole blood
Taparia, N., Platten, K., Anderson, K. B., & Sniadecki, N. J. (2017) · AIP Advances · doi:10.1063/1.4997185 · Cited by 39
Comparison of forward- and back-projection in vivo EPID dosimetry for VMAT treatment of the prostate
Bedford, J. L., Hanson, I. M., & Hansen, V. N. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa9c60 · Cited by 44
Abrahamsen, E. R., Christensen, A.-E., & Hougaard, D. D. (2018) · Otology & Neurotology · doi:10.1097/mao.0000000000001665 · Cited by 39
Mookiah, M. R. K., Rohrmeier, A., Dieckmeyer, M., Mei, K., Kopp, F. K., Noël, P. B., Kirschke, J. S., Baum, T. H., & Subburaj, K. (2018) · Osteoporosis International · doi:10.1007/s00198-017-4342-3 · Cited by 41
Citizen crowds and experts: observer variability in image-based plant phenotyping
Giuffrida, M. V., Chen, F., Scharr, H., & Tsaftaris, S. A. (2018) · Plant Methods · doi:10.1186/s13007-018-0278-7 · Cited by 47
Apfaltrer, G., Albrecht, M. H., Schoepf, U. J., Duguay, T. M., Cecco, C. N. D., Nance, J. W., Santis, D. D., Apfaltrer, P., Eid, M. H., Eason, C. D., et al. (2018) · European Radiology · doi:10.1007/s00330-017-5249-2 · Cited by 45
Validity of Neuropsychological Testing in Young African Children Affected by HIV
Laughton, B., Ratswana, M., Familiar, I., Fairlie, L., Vhembo, T., Kamthunzi, P., Kabugho, E., Joyce, C., Zimmer, B., Ariansen, J., et al. (2018) · Journal of Pediatric Infectious Diseases · doi:10.1055/s-0038-1637020 · Cited by 46
Lima, C. A., de Andrade, A. D., Campos, S. L., Brandão, D. C., Mourato, I. P., & de Britto, M. C. A. (2018) · Respiratory Medicine · doi:10.1016/j.rmed.2018.02.016 · Cited by 39
Čular, D., Ivančev, V., Zagatto, A. M., Milić, M., Bešlija, T., Sellami, M., & Padulo, J. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00543 · Cited by 42
Chuang, L.-L., Chuang, Y.-F., Hsu, M., Huang, Y., Wong, M., & Chang, Y. (2018) · PLoS ONE · doi:10.1371/journal.pone.0189850 · Cited by 43
Vårdal, L., Wong, G., Øiestad, Å. M. L., Pedersen‐Bjergaard, S., Gjelstad, A., & Øiestad, E. L. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1147-y · Cited by 39
Anatomic measurements of cerebral venous sinuses in idiopathic intracranial hypertension patients
Boddu, S. R., Gobin, P., Oliveira, C., Dinkin, M., & Patsalides, A. T. (2018) · PLoS ONE · doi:10.1371/journal.pone.0196275 · Cited by 39
Fielder, M., & Nair, A. K. (2018) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-018-1067-y · Cited by 43
Comparison of three optical biometers: IOLMaster 500, Lenstar LS 900 and Aladdin
Ortiz, A. I., Galvis, V., Tello, A., Viaña, V., corrales, M. I., Ochoa, M., & Rodriguez, C. J. (2018) · International Ophthalmology · doi:10.1007/s10792-018-1006-z · Cited by 39
Accelerating chemical exchange saturation transfer MRI with parallel blind compressed sensing
She, H., Greer, J. S., Zhang, S., Li, B., Keupp, J., Madhuranthakam, A. J., Dimitrov, I. E., Lenkinski, R. E., & Vinogradov, E. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27400 · Cited by 42
Glutamate-sensitive imaging and evaluation of cognitive impairment in multiple sclerosis
O’Grady, K. P., Dula, A. N., Lyttle, B. D., Thompson, L. M., Conrad, B. N., Box, B. A., McKeithan, L. J., Pawate, S., Bagnato, F. R., Landman, B. A., et al. (2018) · Multiple Sclerosis Journal · doi:10.1177/1352458518799583 · Cited by 45
Martin, W. K., Tennant, A. H., Conolly, R. B., Prince, K., Stevens, J. S., DeMarini, D. M., Martin, B. L., Thompson, L. C., Gilmour, M. I., Cascio, W. E., et al. (2019) · Scientific Reports · doi:10.1038/s41598-018-35949-5 · Cited by 41
Marziano, M., Tonello, S., Cantù, E., Abate, G., Vezzoli, M., Rungratanawanich, W., Serpelloni, M., Lopomo, N. F., Memo, M., Sardini, E., et al. (2019) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2019.02.008 · Cited by 41
Karaoğuz, M. R., Yurtseven, E., Aslan, G., Deliormanlı, B. G., Adıgüzel, Ö., Gönen, M., Li, K.-M., & Yılmaz, E. N. (2019) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2019.02.012 · Cited by 40
The Prognostic Value of Myocardial Deformation in Adult Patients With Corrected Tetralogy of Fallot
van Grootel, R. W. J., van den Bosch, A. E., Baggen, V. J. M., Menting, M. E., Baart, S. J., Cuypers, J. A. A. E., Witsenburg, M., & Roos-Hesselink, J. W. (2019) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.03.014 · Cited by 39
Alafeef, M., & Fraiwan, M. (2019) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-019-01339-6 · Cited by 44
Wang, M., Li, Z., Zhang, Q., & Wang, G. (2019) · Sensors · doi:10.3390/s19153312 · Cited by 47
Posterior corneal astigmatism: a review article
Mohammadi, S.-F., Khorrami‐Nejad, M., & Hamidirad, M. (2019) · Clinical Optometry · doi:10.2147/opto.s210721 · Cited by 62
Pini, A., Markström, J. L., & Schelin, L. (2019) · Sports Biomechanics · doi:10.1080/14763141.2019.1655089 · Cited by 47
In-Water and On-Land Swimmers’ Symmetry and Force Production
Carvalho, D., Soares, S. M., Zacca, R., Marinho, D. A., Silva, A. J., Pyne, D. B., Vilas‐Boas, J. P., & Fernandes, R. J. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16245018 · Cited by 39
Sánchez, R., & Mackenzie, S. A. (2020) · Scientific Reports · doi:10.1038/s41598-020-58123-2 · Cited by 42
Wang, Y., Wu, N., Yang, T., & Wang, J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00403 · Cited by 39
Truong, V. T., Palmer, C., Young, M., Wolking, S., Ngo, T. N. M., Sheets, B., Hausfeld, C., Ornella, A., Taylor, M. D., Zaręba, K. M., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-62105-9 · Cited by 39
Kaye, E., Aherne, E. A., Düzgöl, C., Häggström, I., Kobler, E., Mazaheri, Y., Fung, M., Zhang, Z., Otazo, R., Vargas, H. A., et al. (2020) · Radiology Artificial Intelligence · doi:10.1148/ryai.2020200007 · Cited by 49
Proof of Concept for a New Raman-Based Prototype for Noninvasive Glucose Monitoring
Pleus, S., Schauer, S., Jendrike, N. R. M., Zschornack, E., Link, M., Hepp, K. D., Haug, C., & Freckmann, G. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820947112 · Cited by 40
DBAN: Adversarial Network With Multi-Scale Features for Cardiac MRI Segmentation
Yang, X., Zhang, Y., Lo, B. P. L., Wu, D., Liao, H., & Zhang, Y. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3028463 · Cited by 44
Argha, A., Celler, B. G., & Lovell, N. H. (2020) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.3040715 · Cited by 45
Richter, M. J., Yogeswaran, A., Husain‐Syed, F., Vadász, I., Rako, Z. A., Mohajerani, E., Ghofrani, H. A., Naeije, R., Seeger, W., Herberg, U., et al. (2021) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeab038 · Cited by 43
Evidence-Based Respiratory Care
HESS, D. R. (2021) · Respiratory Care · doi:10.4187/respcare.08950 · Cited by 42
Jankowska, A., Młyńczak, K., & Golicki, D. (2021) · Health and Quality of Life Outcomes · doi:10.1186/s12955-021-01780-2 · Cited by 43
Influence of cervical spine position on the radiographic parameters of the thoracic inlet alignment
Janusz, P., Tyrakowski, M., Główka, P., Offoha, R. U., & Siemionow, K. B. (2015) · European Spine Journal · doi:10.1007/s00586-015-4023-x · Cited by 45
Beshara, P., Anderson, D., Pelletier, M. H., & Walsh, W. R. (2021) · Sensors · doi:10.3390/s21248186 · Cited by 43
Liu, G., Qin, Q., Chan, K. W. Y., Li, Y., Bulte, J. W. M., McMahon, M. T., van Zijl, P. C. M., & Gilad, A. A. (2014) · NMR in Biomedicine · doi:10.1002/nbm.3066 · Cited by 39
Fornasier‐Santos, C., Arnould, A., Jusseaume, J., Millot, B., Guilhem, G., Couturier, A., Samozino, P., SLAWINSKI, J. S., & Morin, J.-B. (2022) · Sensors · doi:10.3390/s22228610 · Cited by 39
Cesana, B. M., Antonelli, P., & Ferraro, S. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-0595 · Cited by 90
Šidlauskas, A. (2005) · PubMed · Cited by 39
The accuracy of a new infrared ear thermometer in patients undergoing cardiac surgery
Böck, M., Hohlfeld, U., von Engeln, K., Meier, P. A., Motsch, J., & Tasman, A. (2005) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03021609 · Cited by 39
Arch indexes from ink footprints and pressure platforms are different
Urry, S. R., & Wearing, S. C. (2005) · The Foot · doi:10.1016/j.foot.2005.02.001 · Cited by 39
Time course of the renal functional response to partial nephrectomy: measurements in conscious rats
Chamberlain, R. M., & Shirley, D. G. (2006) · Experimental Physiology · doi:10.1113/expphysiol.2006.034751 · Cited by 39
Congruence of primary brain tumor patient and caregiver symptom report
Armstrong, T. S., Wefel, J. S., Gning, I., Acquaye, A., Vera‐Bolanos, E., Gilbert, M. R., Cleeland, C. S., & Mendoza, T. R. (2012) · Cancer · doi:10.1002/cncr.27483 · Cited by 43
Mahon, A. K., Flynn, M. G., Iglay, H. B., Stewart, L. K., Johnson, C. A., McFarlin, B. K., & Campbell, W. W. (2007) · PubMed · Cited by 47
Musuamba, F. T., Mourad, M., Haufroid, V., Delattre, I., Verbeeck, R. K., & Wallemacq, P. E. (2009) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e3181bf8623 · Cited by 39
Pulmonary Hypertension in Idiopathic Pulmonary Fibrosis: Prevalence and Clinical Progress
Castria, D., Refini, R. M., Bargagli, E., Mezzasalma, F., Pierli, C., & Rottoli, P. (2012) · International Journal of Immunopathology and Pharmacology · doi:10.1177/039463201202500314 · Cited by 40
Assessing Coronary Sinus Blood Flow in Patients with Coronary Artery Disease
Koskenvuo, J. W., Hartiala, J., Knuuti, J. M., Sakuma, H., Toikka, J., Komu, M. E. S., Saraste, M., & Niemi, P. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.5.1771161 · Cited by 39
Davison, D. L., Chawla, L. S., Selassie, L. M., Jones, E. M., McHone, K. C., Vota, A. R., Junker, C. D., Sateri, S., & Seneff, M. G. (2010) · CHEST Journal · doi:10.1378/chest.09-2680 · Cited by 39
Piéroni, L., Khalil, L., Charlotte, F., Poynard, T., Piton, A., Hainque, B., & Imbert‐Bismut, F. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.11.2059 · Cited by 39
Sibal, L., Neely, R. D. G., Jones, A. F., & Home, P. (2010) · Diabetic Medicine · doi:10.1111/j.1464-5491.2009.02888.x · Cited by 46
Intraocular pressure in Lewis rats.
Mermoud, A., Baerveldt, G., Minckler, D. S., Lee, M. B., & Rao, N. A. (1994) · PubMed · Cited by 39
Schurink, G. W. H., Aarts, N. J. M., van Baalen, J. M., Kool, L. J. S., & van Bockel, J. H. (1999) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(99)70105-9 · Cited by 39
Kaşıkçıoğlu, H., Karasulu, L., Durgun, E., Oflaz, H., Kaşıkçıoğlu, E., & Çuhadaroğlu, Ç. (2005) · Heart and Vessels · doi:10.1007/s00380-005-0839-3 · Cited by 43
Cardiovascular function in pregnancy: effects of posture
Bene, R. D., Barletta, G., Mello, G., Lazzeri, C., Mecacci, F., Parretti, E., Martini, E., Vecchiarino, S., Franchi, F., & Villa, G. L. (2001) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1016/s0306-5456(00)00099-1 · Cited by 39
Mackey, A. H., Stott, N. S., & Walt, S. E. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.04.012 · Cited by 39
Evaluation of manual and automatic segmentation of the mouse heart from CINE MR images
Heijman, E., Aben, J., Penners, C., Niessen, P., Guillaume, R., van Eys, G. J. J. M., Nicolay, K., & Strijkers, G. J. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21236 · Cited by 39
Repeatability of corneal and ocular aberration measurements and changes in aberrations over one week
Miranda, M. A., O’Donnell, C., & Radhakrishnan, H. (2009) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2009.00364.x · Cited by 40
Nael, K., Villablanca, J. P., Mossaz, L., Pope, W. B., Juncosa, A., Laub, G. A., & Finn, J. P. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.2297 · Cited by 39
Chio, S., Urbina, E. M., LaPointe, J., Tsai, J., & Berenson, G. S. (2011) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2010.10.005 · Cited by 46
Cappendijk, V. C., Heeneman, S., Kessels, A. G. H., Cleutjens, K. B. J. M., Schurink, G. W. H., Welten, R. J. T. J., Mess, W. H., van Suylen, R. J., Leiner, T., Daemen, M. J. A. P., et al. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21360 · Cited by 39
Repeatability of SUV measurements in serial PET
Schwartz, J., Humm, J. L., Gönen, M., Kalaigian, H., Schöder, H. M., Larson, S. M., & Nehmeh, S. A. (2011) · Medical Physics · doi:10.1118/1.3578604 · Cited by 44
Duce, B., Rego, C., Milosavljevic, J., & Hukins, C. (2014) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.3880 · Cited by 46
Dynamic visuomotor synchronization: Quantification of predictive timing
Maruta, J., Heaton, K. J., Kryskow, E. M., Maule, A. L., & Ghajar, J. (2012) · Behavior Research Methods · doi:10.3758/s13428-012-0248-3 · Cited by 43
Maximal heart rate in soccer players: Measured versus age-predicted
Nikolaidis, P. Τ. (2014) · Biomedical Journal · doi:10.4103/2319-4170.131397 · Cited by 47
Lima, E. D. P., Barreto, S. M., & Assunção, A. Á. (2012) · Trends in Psychiatry and Psychotherapy · doi:10.1590/s2237-60892012000400007 · Cited by 40
Pauliks, L. B., Pietra, B. A., Kirby, S., Logan, L., DeGroff, C. G., Boucek, M. M., & Valdes‐Cruz, L. M. (2005) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2004.05.032 · Cited by 39
Ahmed, W., Graaf, M. A. D., Broersen, A., Kitslaar, P. H., Oost, E., Dijkstra, J., Bax, J. J., Reiber, J. H. C., & Scholte, A. J. H. A. (2014) · International journal of cardiac imaging · doi:10.1007/s10554-014-0519-4 · Cited by 43
Papaioannou, T. G., Protogerou, A. D., Nasothimiou, E. G., Tzamouranis, D., Skliros, N., Achimastos, A. D., Papadogiannis, D., & Stefanadis, C. (2011) · Journal of Human Hypertension · doi:10.1038/jhh.2011.76 · Cited by 47
Chia, S., Cott, E. M. V., Raffel, O., & Jang, I. (2009) · Thrombosis and Haemostasis · doi:10.1160/th08-08-0528 · Cited by 39
Myou, S., Fujimura, M., Kamio, Y., Ishiura, Y., Kurashima, K., TACHIBANA, H., Hirose, T., & Hashimoto, T. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9907127 · Cited by 40
Clarys, J. P., Scafoglieri, A., Provyn, S., Louis, O., Wallace, J. A., & Mey, J. D. (2009) · Obesity · doi:10.1038/oby.2009.447 · Cited by 51
Estimation of the Anaerobic Threshold from Heart Rate Variability in an Incremental Swimming Test
Michele, R. D., Gatta, G., Leo, A. D., Cortesi, M., Andina, F., Tam, E., Boit, M. D., & Merni, F. (2011) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e318245bde1 · Cited by 52
OncoTREAT: a software assistant for cancer therapy monitoring
Bornemann, L., Dicken, V., Kuhnigk, J., Wormanns, D., Shin, H., Bauknecht, H.-C., Diehl, V., Fabel, M., Meier, S., Kress, O., et al. (2006) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-006-0059-z · Cited by 39
Measurement of T-helper cytokines secreted by cord blood mononuclear cells in response to allergens
Devereux, G. S., Hall, A. M., & Barker, R. N. (2000) · Journal of Immunological Methods · doi:10.1016/s0022-1759(99)00185-4 · Cited by 39
Vastus Lateralis O2 Desaturation in Response to Fast and Short Maximal Contraction
CETTOLO, V., FERRARI, M., BIASINI, V., & QUARESIMA, V. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181453476 · Cited by 40
The influence of inhaler selection on efficacy of asthma therapies
Barry, P. W., & O’Callaghan, C. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(03)00083-8 · Cited by 39
Renal Tract Calculi: Comparison of Stone Size on Plain Radiography and Noncontrast Spiral CT Scan
Dundee, P. E., Bouchier-Hayes, D., Haxhimolla, H. Z., Dowling, R., & Costello, A. J. (2006) · Journal of Endourology · doi:10.1089/end.2006.20.1005 · Cited by 39
Feng, J., Qiu, L., Zhang, L., Li, X.-M., Yang, Y.-W., Zeng, P., Guo, X.-Z., Qin, Y., Liu, H.-C., Han, X.-M., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0057240 · Cited by 39
Yang, F., Leung, K. Y., Hou, Y. ‐., Yuan, Y., & Tang, M. (2011) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.8945 · Cited by 39
Segmentation of fat and muscle from MR images of the thigh by a possibilistic clustering algorithm
Barra, V., & Boire, J. Y. (2002) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(01)00172-9 · Cited by 39
Specific weight formula for fetuses with abdominal wall defects
Siemer, J., Hilbert, A., Hart, N., Hoopmann, M., Schneider, U., Girschick, G., MÜLLER, A. E., & Schild, R. L. (2008) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.5294 · Cited by 41
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.