STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 12,901–13,000 of 47,868
Point-of-care (POC) versus central laboratory instrumentation for monitoring oral anticoagulation
Dorfman, D. M., Goonan, E. M., Boutilier, M. K., Jarolı́m, P., Tanasijevic, M. J., & Goldhaber, S. Z. (2005) · Vascular Medicine · doi:10.1191/1358863x05vm587oa · Cited by 39
WHITEHAIR, K. J., Watney, G. C. G., LEITH, D. E., & DeBowes, R. M. (1990) · Veterinary Surgery · doi:10.1111/j.1532-950x.1990.tb01179.x · Cited by 47
On-line assessment of delivered dialysis dose: Technical Note
Filippo, S. D., Andrulli, S., Manzoni, C., Corti, M., & Locatelli, F. (1998) · Kidney International · doi:10.1046/j.1523-1755.1998.00979.x · Cited by 39
Schmalisch, G., Foitzik, B., Wauer, R., & Stocks, J. (2001) · European Respiratory Journal · doi:10.1183/09031936.01.17101080 · Cited by 39
Detection of β-herpesviruses in allogenic stem cell recipients by quantitative real-time PCR
Sassenscheidt, J., Rohayem, J., Illmer, T., & Bandt, D. (2006) · Journal of Virological Methods · doi:10.1016/j.jviromet.2006.07.015 · Cited by 46
Macroscopic assessment of pulmonary emphysema by image analysis.
Gevenois, P. A., Zanen, J., Maertelaer, V. D., Vuyst, P. D., Dumortier, P., & Yernault, J. C. (1995) · Journal of Clinical Pathology · doi:10.1136/jcp.48.4.318 · Cited by 39
Nowak, B., Stellbrink, C., Schaefer, W. M., Sinha, A. M., Breithardt, O. A., Kaiser, H.-J., Reinartz, P., Hanrath, P., & Buell, U. (2004) · PubMed · Cited by 39
A digital subtraction radiography scheme based on automatic multiresolution registration
Zacharaki, E. I., Matsopoulos, G. K., Asvestas, P. A., Nikita, K. S., Gröndahl, K., & Gröndahl, H. G. (2004) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/21571843 · Cited by 46
Comparing ophthalmoscopy, slide viewing, and semiautomated systems in optic disc morphometry
Ikram, M. K., Borger, P. H., Assink, J. J. M., Jonas, J. B., Albert Hofman, D., & de Jong, P. T. V. M. (2002) · Ophthalmology · doi:10.1016/s0161-6420(01)00983-6 · Cited by 39
Clinical scoring systems in cystic fibrosis
Hafen, G., Ranganathan, S., ROBERTSON, C. F., & Robinson, P. J. (2006) · Pediatric Pulmonology · doi:10.1002/ppul.20376 · Cited by 41
McDermott, S., Barry, S. C., Judge, E. E., Collins, S. E., de Jong, P. A., Tiddens, H. A. W. M., McKone, E. F., Gallagher, C. G., & Dodd, J. D. (2009) · Radiology · doi:10.1148/radiol.2522081956 · Cited by 39
Doherty, C. P., Fitzsimons, M. B., Holohan, T., Mohamed, H. B., Farrell, M., Meredith, G. E., & Staunton, H. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00185-5 · Cited by 41
Comparison of Commercial Real-Time PCR Assays for Quantification of Epstein-Barr Virus DNA
Carrascoso, G. R., Peña, P., de Ory, F., & Echevarría, J. E. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.5.2053-2057.2005 · Cited by 39
Predicting deterioration of treated tuberculosis by corticosteroid reserve and C-reactive protein
Scott, G. M., Murphy, P., & Gemidjioglu, M. (1990) · Journal of Infection · doi:10.1016/0163-4453(90)90669-y · Cited by 39
Okazawa, H., Takahashi, M., Hata, T., Sugimoto, K., Kishibe, Y., & Tsuji, T. (2002) · PubMed · Cited by 39
“Medullary Ray Glomerular Counting” as a Method of Assessment of Human Nephrogenesis
Hinchliffe, S. A., Sargent, P. H., Chan, Y. F., van Velzen, D., Howard, C. V., Hutton, J. L., & Rushton, D. I. (1992) · Pathology - Research and Practice · doi:10.1016/s0344-0338(11)80177-9 · Cited by 39
Cole, D. E. C., Lehotay, D. C., & Evrovski, J. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.1.188 · Cited by 39
Therapy of Patients with Head Injuries: Key Parameters for Management
Prough, D. S., & Lang, J. D. (1997) · doi:10.1097/00005373-199705001-00003 · Cited by 39
Therapeutic drug monitoring of antiepileptics by capillary electrophoresis
Thormann, W., Theurillat, R., Wind, M., & Kuldvee, R. (2001) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)00854-8 · Cited by 39
Clifford, C., Day, A., Cox, J., & Werrett, J. (1999) · Journal of Advanced Nursing · doi:10.1046/j.1365-2648.1999.01115.x · Cited by 55
External Imaging of Atherosclerosis in Rabbits Using an 123I‐Labeled Synthetic Peptide Fragment
Hardoff, R., Braegelmann, F., ZANZONICO, P. B., Herrold, E. M., Lees, R. S., Lees, A. M., Dean, R. T., Lister‐James, J., & BORER, J. S. (1993) · The Journal of Clinical Pharmacology · doi:10.1002/j.1552-4604.1993.tb01940.x · Cited by 39
Continuous haemodynamic monitoring in children: use of transoesophageal Doppler
Murdoch, I., Marsh, M., Tibby, S. M., & McLuckie, A. (1995) · Acta Paediatrica · doi:10.1111/j.1651-2227.1995.tb13751.x · Cited by 39
Reliability of Six Pulse Oximeters in Chronic Obstructive Pulmonary Disease
Hannhart, B., Michalski, H., Delorme, N., Chapparo, G., & Polu, J. M. (1991) · CHEST Journal · doi:10.1378/chest.99.4.842 · Cited by 39
Kofoed, S. C., Grønholdt, M.-L. M., Wilhjelm, J. E., Bismuth, J. X., & Sillesen, H. H. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00430-6 · Cited by 39
Quantifying Aortic Regurgitation by Using the Color Doppler–Imaged Vena Contracta
Ishii, M., Jones, M., Shiota, T., Yamada, I., Heinrich, R. S., Holcomb, S., Yoganathan, A. P., & Sahn, D. J. (1997) · Circulation · doi:10.1161/01.cir.96.6.2009 · Cited by 39
Time-dependent systolic and diastolic function in mice overexpressing calcineurin
Semeniuk, L., Severson, D. L., Kryski, A. J., Swirp, S., Molkentin, J. D., & Duff, H. J. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00546.2002 · Cited by 39
Rethans, J., & Saebu, L. (1997) · BMJ · doi:10.1136/bmj.314.7088.1170 · Cited by 41
Motor cortex and hand motor skills: Structural compliance in the human brain
Amunts, K., Schlaug, G., Jäncke, L., Steinmetz, H., Schleicher, A., Dabringhaus, A., & Zilles, K. (1997) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1997)5:3<206::aid-hbm5>3.0.co;2-7 · Cited by 426
Rosemann, T. J., Körner, T., Wensing, M., Schneider, A., & Szécsényi, J. (2005) · Rheumatology · doi:10.1093/rheumatology/keh718 · Cited by 42
Responsiveness of the Cochin rheumatoid hand disability scale after surgery
Lefèvre‐Colau, M., Poiraudeau, S., Fermanian, J., Etchepare, F., Alnot, J. Y., Viet, D. L., Leclercq, C., Oberlin, C., Bargy, F., & Revel, M. (2001) · British journal of rheumatology · doi:10.1093/rheumatology/40.8.843 · Cited by 42
Klar, E., Kraus, T. W., Bleyl, J. U., Newman, W. H., Bowman, H. F., Hofmann, W. J., von Kummer, R., Bredt, M., & Herfarth, C. H. (1999) · Microvascular Research · doi:10.1006/mvre.1999.2166 · Cited by 39
van der Zander, K. (1999) · Cardiovascular Research · doi:10.1016/s0008-6363(99)00234-5 · Cited by 39
Testolin, C. G., Gore, R., Rivkin, T., Horlick, M., Arbo, J., Wang, Z., Chiumello, G., & Heymsfield, S. B. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.6.2365 · Cited by 39
Automated blood pressure measurement devices: A potential source of morbidity in preeclampsia?
Quinn, M. (1994) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(13)90454-3 · Cited by 40
Schröder, K. M., Sapin, P. M., King, D. L., Smith, M. D., & DeMaria, A. N. (1993) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(14)80465-3 · Cited by 39
Alpiger, S., Helbo-Hansen, H. S., & Jensen, E. W. (2002) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2002.460305.x · Cited by 39
Economos, C. D., Nelson, M. E., Fiatarone, M., Dallal, G., Heymsfield, S. B., Wang, J., Yasumara, S., Ma, R., Vaswani, A., Russell-Aulet, M., et al. (1997) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600400 · Cited by 42
Influence of Environmental Concentrations of NO on the Exhaled NO Test
PIACENTINI, G. L., Bodini, A., Vino, L., Zanolla, L., Costella, S., VICENTINI, L., & BONER, A. L. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.4.9712078 · Cited by 45
Contributions of Vascular Tone and Structure to Elastic Properties of a Medium-Sized Artery
Weber, R., Stergiopulos, N., Brunner, H. R., & Hayoz, D. (1996) · Hypertension · doi:10.1161/01.hyp.27.3.816 · Cited by 39
Purokivi, M., Randell, J., Hirvonen, M.-R., & Tukiainen, H. (2000) · European Respiratory Journal · doi:10.1034/j.1399-3003.2000.16b10.x · Cited by 39
Ueyama, T., Ohkusa, T., Hisamatsu, Y., Nakamura, Y., Yamamoto, T., Yano, M., & Matsuzaki, M. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.1.h1 · Cited by 39
Does Google Scholar contain all highly cited documents (1950-2013)?
Martín‐Martín, A., Orduña‐Malea, E., Ayllón, J. M., & López‐Cózar, E. D. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1410.8464 · Cited by 30
Kim, C.-J., Berglund, H., Nishioka, T., Luo, H., & Siegel, R. J. (1996) · American Heart Journal · doi:10.1016/s0002-8703(96)90459-7 · Cited by 39
Prescott, R. J. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2018.06.172 · Cited by 40
Nørgaard, S. K., Mathiesen, E. R., Nørgaard, K., & Ringholm, L. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0109 · Cited by 38
Development of an accurate oscillometric blood pressure device for low resource settings
de Greeff, A., Nathan, H., Stafford, N., Liu, B., & Shennan, A. H. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32830fd07c · Cited by 38
Sardinha, L. B., Correia, I. R., Magalhães, J. P., Júdice, P. B., Silva, A. M., & Hetherington-Rauth, M. (2020) · European Journal of Clinical Nutrition · doi:10.1038/s41430-020-0666-8 · Cited by 38
Zhu, M., Chew, J. K., Broadhead, G. K., Luo, K., Joachim, N., Hong, T., Syed, A., & Chang, A. A. (2015) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-014-2799-8 · Cited by 38
Kistorp, C., & Svendsen, O. (1997) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600424 · Cited by 38
Catalá-López, F., Aleixandre-Benavent, R., Caulley, L., Hutton, B., Tabarés-Seisdedos, R., Moher, D., & Alonso-Arroyo, A. (2020) · Trials · doi:10.1186/s13063-019-3944-9 · Cited by 38
Clinical significance of low cytomegalovirus DNA levels in human plasma
Waggoner, J., Ho, D. Y., Libiran, P., & Pinsky, B. A. (2012) · Journal of Clinical Microbiology · doi:10.1128/jcm.06800-11 · Cited by 38
The Reliability of the Seated Medicine Ball Throw for Distance
Beckham, G., Lish, S., Keebler, L., Longaker, C., Disney, C., DeBeliso, M., & J. Adams, K. (2019) · Journal of Physical Activity Research · doi:10.12691/jpar-4-2-9 · Cited by 38
Energy expenditure assessed by heart rate and doubly labeled water in young athletes
EKELUND, U., YNGVE, A., WESTERTERP, K., & SJ??STR??M, M. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200208000-00019 · Cited by 38
Gavala, A., & Myrianthefs, P. (2017) · Heart & Lung · doi:10.1016/j.hrtlng.2017.04.003 · Cited by 38
dos Passos, M. H. P., Silva, H. A., Pitangui, A. C. R., de Oliveira, V. M. A., Lima, A. S., & de Araújo, R. C. (2017) · Jornal de Pediatria (Versão em Português) · doi:10.1016/j.jpedp.2016.08.010 · Cited by 52
Hannadige, N., Zhai, P., Gao, M., Franz, B. A., Hu, Y., Knobelspiesse, K., Werdell, P. J., Ibrahim, A. I., Cairns, B., & Hasekamp, O. (2021) · Optics Express · doi:10.1364/oe.408467 · Cited by 39
A comparison of test-retest reliability of four cognitive screening tools in people with dementia
Lee, Y., Lin, Y.-T., & Chiu, E. (2021) · Disability and Rehabilitation · doi:10.1080/09638288.2021.1891466 · Cited by 43
Lawrence, L., Chan, R. W., Chen, H., Keller, B. M., Stewart, J., Ruschin, M., Chugh, B. P., Campbell, M., Theriault, A., Stanisz, G. J., et al. (2021) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2021.09.020 · Cited by 43
Fritz, B., Fritz, J. M., Fucentese, S. F., Pfirrmann, C. W. A., & Sutter, R. (2021) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2021.11.019 · Cited by 38
Marinari, S., Volpe, P., Simoni, M., Aventaggiato, M., Benedetto, F. D., Nardini, S. G., Sanguinetti, C. M., & Palange, P. (2022) · Sensors · doi:10.3390/s22135031 · Cited by 48
The reliability and validity of gait analysis system using 3D markerless pose estimation algorithms
Liang, S., Zhang, Y., Diao, Y., Li, G., & Zhao, G. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.857975 · Cited by 48
Płotka, S., Grzeszczyk, M. K., Szenejko, P. I., Żebrowska, K., Szymecka-Samaha, N., Łęgowik, T., Lipa, M., Kosińska–Kaczyńska, K., Brawura-Biskupski-Samaha, R., Išgum, I., et al. (2023) · American Journal of Obstetrics & Gynecology MFM · doi:10.1016/j.ajogmf.2023.101182 · Cited by 43
Zhao, L., Tan, G., Pu, B., Wu, Q., Ren, H., & Li, K. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3328954 · Cited by 43
Gupta, S., Dubey, A. K., Singh, R., Kalra, M. K., Abraham, A., Kumari, V., Laird, J. R., Al-Maini, M., Gupta, N., Singh, I. M., et al. (2024) · Diagnostics · doi:10.3390/diagnostics14141534 · Cited by 56
Dental Side Effects of Mandibular Advancement Appliances – A 2-year Follow-up
Ghazal, A., Jonas, I. E., & Rose, E. C. (2008) · Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie · doi:10.1007/s00056-008-0811-9 · Cited by 39
Quantitative assessment of gait parameters in horses: Useful for aiding clinical decision making?
Pfau, T., Fiske‐Jackson, A. R., & Rhodin, M. (2015) · Equine Veterinary Education · doi:10.1111/eve.12372 · Cited by 38
Juneja, P., Kneebone, A. B., Booth, J., Thwaites, D., Kaur, R., Colvill, E., Ng, J. A., Keall, P., & Eade, T. (2015) · Radiation Oncology · doi:10.1186/s13014-015-0526-1 · Cited by 38
Aquaro, G. D., Todiere, G., Strata, E., Barison, A., Bella, G. D., & Lombardi, M. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24335 · Cited by 38
Otieno, P. O., Owuor, P. O., Lalah, J. O., Pfister, G., & Schramm, K. (2012) · Environmental Monitoring and Assessment · doi:10.1007/s10661-012-2743-5 · Cited by 41
Dimensions and morphologic variations of sella turcica in type 1 diabetic patients
Bavbek, N. C., & Dinçer, M. (2014) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2013.10.011 · Cited by 41
What you need to know about statistics, part II: reliability of diagnostic and screening tests
Zidan, M. A., Thomas, R., & Slovis, T. L. (2015) · Pediatric Radiology · doi:10.1007/s00247-014-2944-x · Cited by 38
Wilhelm, A. J., Klijn, A., den Burger, J. C. G., Visser, O. J., Veldkamp, A. I., Janssen, J. J. W. M., & Swart, E. L. (2013) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e31827d76ce · Cited by 38
The labor induction: integrated clinical and sonographic variables that predict the outcome
Bueno, B., Sanfrutos, L., Pérez‐Medina, T., Barbancho, C., Troyano, J. M., & Bajo, J. (2006) · Journal of Perinatology · doi:10.1038/sj.jp.7211619 · Cited by 38
Single-step preparation and image-based counting of minute volumes of human blood
Smith, Z. J., Gao, T., Chu, K., Lane, S. M., Matthews, D. L., Dwyre, D. M., Hood, J., Tatsukawa, K. J., Heifetz, L. J., & Wachsmann‐Hogiu, S. (2014) · Lab on a Chip · doi:10.1039/c4lc00567h · Cited by 41
Validation of the central blood pressure estimation by the SphygmoCor system in Chinese
Zuo, J., Li, Y., Yan, Z., Zhang, R., Shen, W.-F., Zhu, D., Gao, P., & Chu, S. (2010) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283386866 · Cited by 41
Wright, F. V., Ryan, J. L., & Brewer, K. (2010) · Brain Injury · doi:10.3109/02699052.2010.523045 · Cited by 38
Su, B.-C., Yu, H., Yang, M., Lin, C., Kao, M., Chang, C.-H., & Lee, W. (2008) · Liver Transplantation · doi:10.1002/lt.21461 · Cited by 38
PAT tools for the control of co-extrusion implants manufacturing process
Krier, F., Mantanus, J., Sacré, P., Chavez, P.-F., Thiry, J., Pestieau, A., Rozet, E., Ziémons, E., Hubert, P., & Évrard, B. (2013) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2013.09.040 · Cited by 42
Capsaicin cough threshold test in diagnostics
Pullerits, T., Ternestén‐Hasseus, E., Johansson, E., & Millqvist, E. (2014) · Respiratory Medicine · doi:10.1016/j.rmed.2014.07.012 · Cited by 40
Critical Review of Existing Patient Reported Outcome Measures After Male Anterior Urethroplasty
Voelzke, B. B. (2012) · The Journal of Urology · doi:10.1016/j.juro.2012.08.096 · Cited by 39
Taton, O., Fagnoul, D., Backer, D. D., & Vincent, J. (2013) · Anaesthesia · doi:10.1111/anae.12341 · Cited by 38
Lee, H., Chung, J. L., Kim, E. K., Sgrignoli, B., & Kim, T. (2012) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2012.04.035 · Cited by 38
Comparability of tympanic and oral mercury thermometers at high ambient temperatures
Chue, A. L., Moore, R. L., Cavey, A., Ashley, E. A., Stepniewska, K., Nosten, F. H., & McGready, R. M. (2012) · BMC Research Notes · doi:10.1186/1756-0500-5-356 · Cited by 38
Bernardo, M. D., Borrelli, M., Imparato, R., Cione, F., & Rosa, N. (2020) · Photodiagnosis and Photodynamic Therapy · doi:10.1016/j.pdpdt.2020.101976 · Cited by 38
McDonald, V. M., Higgins, I., Simpson, J. L., & Gibson, P. G. (2011) · Primary Care Respiratory Journal · doi:10.4104/pcrj.2011.00025 · Cited by 43
Ladi, J., & Shah, N. (2010) · Indian Journal of Ophthalmology · doi:10.4103/0301-4738.67045 · Cited by 38
Bone marrow fat is increased in chronic kidney disease by magnetic resonance spectroscopy
Moorthi, R. N., Fadel, W. F., Eckert, G. J., Ponsler-Sipes, K., Moe, S. M., & Lin, C. (2015) · Osteoporosis International · doi:10.1007/s00198-015-3064-7 · Cited by 38
Adsuar, J. C., Olivares, P. R., Cruz, B. D. P., Parraça, J. A., & Gusi, N. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.04.017 · Cited by 38
Reliability of radiographic measurement of small intestinal length
Shatari, T., Clark, M. A., Lee, J. R., & Keighley, M. R. B. (2004) · Colorectal Disease · doi:10.1111/j.1463-1318.2004.00603.x · Cited by 38
Evaluation of stroke volume variations obtained with the pressure recording analytic method*
Biais, M., Cottenceau, V., Stecken, L., Jean, M., Ottolenghi, L., Roullet, S., Quinart, A., & Sztark, F. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e31823bc632 · Cited by 38
Hussain, M., Northoff, H., & Gehring, F. K. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.12.003 · Cited by 38
Dula, A. N., Dewey, B. E., Arlinghaus, L. R., Williams, J. M., Klomp, D. W. J., Yankeelov, T. E., & Smith, S. A. (2014) · Radiology · doi:10.1148/radiol.14140762 · Cited by 38
A review of fetal volumetry: the need for standardization and definitions in measurement methodology
Ioannou, C., Sarris, I., Salomon, L. J., & Papageorghiou, A. T. (2011) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.9074 · Cited by 44
Beijst, C., Schep, G., van Breda, E., Wijn, P. F. F., & van Pul, C. (2012) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2012.733057 · Cited by 49
Santillo, M. F., Liu, Y., Ferguson, M. S., Vohra, S., & Wiesenfeld, P. L. (2014) · Toxicology in Vitro · doi:10.1016/j.tiv.2013.12.006 · Cited by 42
Taniguchi, Y., Emoto, N., Miyagawa, K., Nakayama, K., Kinutani, H., Tanaka, H., Shinke, T., & Hirata, K. (2013) · Circulation Journal · doi:10.1253/circj.cj-13-0172 · Cited by 40
Wells, J. C. K., Stocks, J., Bonner, R., Raywood, E., Legg, S., Lee, S., Treleaven, P. C., & Lum, S. (2015) · PLoS ONE · doi:10.1371/journal.pone.0124193 · Cited by 44
iCap: Instrumented assessment of physical capability
Godfrey, A., Lara, J., Din, S. D., Hickey, A., Munro, C. A., Wiuff, C., Chowdhury, S. A., Mathers, J. C., & Rochester, L. (2015) · Maturitas · doi:10.1016/j.maturitas.2015.04.003 · Cited by 38
Kennedy, L., & Herman, W. H. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.907 · Cited by 39
WHO Multicenter Evaluation of FACSCount CD4 and Pima CD4 T-Cell Count Systems
Wade, D., Daneau, G., Aboud, S., Vercauteren, G., Urassa, W. K., & Kestens, L. (2014) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/qai.0000000000000214 · Cited by 38
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.