STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 13,101–13,200 of 47,868
Wikström, J., Grönros, J., & Gan, L. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.12.004 · Cited by 39
Histological assessment of pre‐transplant kidney biopsies is reproducible and representative
Snoeijs, M. G., Boonstra, L. A., Buurman, W. A., Goldschmeding, R., van Suylen, R. J., van Heurn, E. L. W., & Peutz‐Kootstra, C. J. (2009) · Histopathology · doi:10.1111/j.1365-2559.2009.03469.x · Cited by 39
The energy cost of household and garden activities in 55- to 65-year-old males
Gunn, S. M., Brooks, A. G., Withers, R. T., Gore, C. J., Plummer, J. L., & Cormack, J. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1302-3 · Cited by 41
Palmar Abduction: Reliability of 6 Measurement Methods in Healthy Adults
de Kraker, M., Selles, R. W., Schreuders, T. A. R., Stam, H. J., & Hovius, S. E. R. (2009) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2008.10.028 · Cited by 44
Reinders, A., Cuckson, A. C., Jones, C., Poet, R. H., O’Sullivan, G., & Shennan, A. H. (2003) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1046/j.1471-0528.2003.02038.x · Cited by 38
Seo, N. J., Armstrong, T. J., & Drinkaus, P. (2009) · Ergonomics · doi:10.1080/00140130802238622 · Cited by 38
Jose, R. J. P., & Preller, J. (2008) · Emergency Medicine Journal · doi:10.1136/emj.2007.053322 · Cited by 38
Fleischman, A., Makimura, H., Stanley, T. L., McCarthy, M. A., Kron, M., Sun, N., Chuzi, S., Hrovat, M. I., Systrom, D. M., & Grinspoon, S. K. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-0527 · Cited by 38
Kööbi, T., Kaukinen, & Turjanmaa, V. (1999) · Critical Care Medicine · doi:10.1097/00003246-199910000-00023 · Cited by 38
Huysmans, M. C. D. N. J. M., Longbottom, C., Hintze, H., & Verdonschot, E. H. (1998) · Caries Research · doi:10.1159/000016468 · Cited by 38
A "throttle" mechanism in the central retinal vein in the region of the lamina cribrosa
Williamson, T. H. (2006) · British Journal of Ophthalmology · doi:10.1136/bjo.2006.102798 · Cited by 38
Yang, S., Li, X., Chao, B., Wu, L., Cheng, Z., Duan, Y., Wu, D., Zhan, Y., Chen, J., Liu, B., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0087664 · Cited by 38
Office blood pressure measurements overestimate blood pressure control in renal transplant patients
Stenehjem, A., Gudmundsdottir, H., & Os, I. (2006) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000209080.24870.2d · Cited by 41
Real-Time 3D Fusion Echocardiography
Szmigielski, C. A., Rajpoot, K., Grau, V., Myerson, S. G., Holloway, C. J., Noble, J. A., Kerber, R. E., & Becher, H. H. (2010) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2010.03.010 · Cited by 38
Marijnissen, A. C. A., Vincken, K. L., Viergever, M. A., van Roy, H. L. A. M., van Roermund, P. M., Lafeber, F. P. J. G., & Bijlsma, J. W. J. (2001) · Osteoarthritis and Cartilage · doi:10.1053/joca.2000.0384 · Cited by 38
Retrospective Analysis of Nasal Soft Tissue Profile Changes With Maxillary Surgery
Mısır, A. F., Manisalı, M., Eğrioğlu, E., & Naini, F. B. (2011) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2010.10.032 · Cited by 39
Comparison of near fusional vergence ranges with rotary prisms and with prism bars
Goss, D. A., & Becker, E. (2010) · Optometry · doi:10.1016/j.optm.2010.09.011 · Cited by 49
Reproducibility of volume measurements of vestibular schwannomas – a preliminary study
Cross, J., Baguley, D., Antoun, N. M., Moffat, D. A., & Prevost, A. T. (2006) · Clinical Otolaryngology · doi:10.1111/j.1749-4486.2006.01161.x · Cited by 38
Suehiro, K., Tanaka, K., Matsuura, T., Funao, T., Yamada, T., Mori, T., & Nishikawa, K. (2014) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2014.02.020 · Cited by 42
Accuracy and Reproducibility of a Novel Dual-Beam Vector Doppler Method
Ricci, S., Diciotti, S., Francalanci, L., & Tortoli, P. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.10.012 · Cited by 40
Reliability of Goniometry‐Based Q‐Angle
Weiss, L. W., DeForest, B. A., Hammond, K. G., Schilling, B. K., & Ferreira, L. (2013) · PM&R · doi:10.1016/j.pmrj.2013.03.023 · Cited by 38
Inter-rater reliability of malaria parasite counts and comparison of methods
Bowers, K., Bell, D., Chiodini, P. L., Barnwell, J. W., Incardona, S., Yen, S., Luchavez, J., & Watt, H. (2009) · Malaria Journal · doi:10.1186/1475-2875-8-267 · Cited by 38
Paakkala, A., Sillanpaa, P. J., Huhtala, H., Paakkala, T., & Mäenpää, H. M. (2010) · Skeletal Radiology · doi:10.1007/s00256-009-0858-8 · Cited by 38
Ammersbach, M., Beaufrère, H., Rollick, A. G., & Tully, T. N. (2015) · Veterinary Clinical Pathology · doi:10.1111/vcp.12229 · Cited by 39
Clinical Validation of a Novel Speckle-Tracking–Based Ejection Fraction Assessment Method
Szulik, M., Pappas, C. J., Jurcut, R. O., Magro, M., Peeters, E., Goetschalckx, K., Rademakers, F. E., Desmet, W. J., & Voigt, J. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.05.004 · Cited by 38
Development and validation of a nutritional questionnaire for the Palestine population
Hamdan, M., Monteagudo, C., Lorenzo, M. L., Tur, J., Olea‐Serrano, F., & Mariscal‐Arcas, M. (2013) · Public Health Nutrition · doi:10.1017/s1368980013002711 · Cited by 50
Yap, W. S., Chan, C. C., Chan, S. P., & WANG, Y. T. (2001) · Respiratory Medicine · doi:10.1053/rmed.2001.1038 · Cited by 44
Measurement of high resolution ECG QT interval during controlled euglycaemia and hypoglycaemia
Ireland, R. H., Robinson, R. T. C. E., Heller, S. R., Marques, J. L. B., & Harris, N. D. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/309 · Cited by 38
Dahlman, P., van der Molen, A. J., Magnusson, M. O., & Magnusson, A. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.11.7209 · Cited by 38
Ferraris, J. R., Ghezzi, L., Waisman, G. D., & Krmar, R. T. (2006) · Pediatric Transplantation · doi:10.1111/j.1399-3046.2006.00595.x · Cited by 38
A practical method for estimating enclosed volumes using 3D ultrasound
Thune, N., Gilja, O. H., Hausken, T., & Matre, K. (1996) · European Journal of Ultrasound · doi:10.1016/0929-8266(95)00136-0 · Cited by 38
McMurdy, J. W., Jay, G. D., Suner, S., Trespalacios, F., & Crawford, G. P. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2167967 · Cited by 38
Wu, V., Kuo, C., Chang, H., Tsai, C., Lin, C., Lin, L., Lin, Y., Wang, S., Huang, K., Fang, C., et al. (2010) · Clinica Chimica Acta · doi:10.1016/j.cca.2010.01.027 · Cited by 40
Tanaka, T., Manabe, N., Hata, J., Kusunoki, H., Ishii, M., Sato, M., Kamada, T., Shiotani, A., & Haruma, K. (2008) · Neurogastroenterology & Motility · doi:10.1111/j.1365-2982.2007.01039.x · Cited by 38
Tang, S. T. (2006) · Cancer Nursing · doi:10.1097/00002820-200601000-00009 · Cited by 38
Kamimura, M. A., dos Santos, N. S. J., Avesani, C. M., Canziani, M. E. F., Draibe, S. A., & Cuppari, L. (2003) · Journal of the American Dietetic Association · doi:10.1053/jada.2003.50024 · Cited by 38
Hemphill, J. C., Barton, C. W., Morabito, D. J., & Manley, G. T. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/4/004 · Cited by 39
Bachner-Hinenzon, N., Ertracht, O., Leitman, M., Vered, Z., Shimoni, S., Beeri, R., Binah, O., & Adam, D. (2010) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00017.2010 · Cited by 38
Miyashita, H., Ikeda, U., Tsuruya, Y., Sekiguchi, H., Shimada, K., & Yaginuma, T. (1994) · Heart and Vessels · doi:10.1007/bf01744493 · Cited by 38
Sun, H., Dul, M. W., & Swanson, W. H. (2006) · Optometry and Vision Science · doi:10.1097/01.opx.0000225103.18087.5d · Cited by 39
Validity of arterialized earlobe blood gases at rest and exercise in normoxia and hypoxia
Mollard, P., Bourdillon, N., Letournel, M., Herman, H., Gibert, S., Pichon, A., Woorons, X., & Richalet, J. (2010) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2010.05.017 · Cited by 41
A new parameter for characterizing balancing ability on an unstable oscillatory platform
Kiss, R. M. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.04.017 · Cited by 38
An Improved Method for Automatic Segmentation of the Left Ventricle in Myocardial Perfusion SPECT
Soneson, H., Ubachs, J. F. A., Ugander, M., Arheden, H., & Heiberg, E. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057323 · Cited by 38
SANDERCOCK, G. R. H., Bromley, P. D., & Brodie, D. A. (2004) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2004.00584.x · Cited by 44
Superior accuracy of model-based radiostereometric analysis for measurement of polyethylene wear
Stilling, M., Kold, S., de Raedt, S., Andersen, N. T., Rahbek, O., & Søballé, K. (2012) · Bone and Joint Research · doi:10.1302/2046-3758.18.2000041 · Cited by 38
A PDMS-based disposable microfluidic sensor for CD4+ lymphocyte counting
Thorslund, S., Larsson, R., Bergquist, J., Nikolajeff, F. K., & Sánchez, J. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9199-y · Cited by 38
Assessment of total body fat using the skinfold technique in full-term and preterm infants
Olhager, E., & Forsum, E. (2005) · Acta Paediatrica · doi:10.1080/08035250500323731 · Cited by 38
Hübner, G., Steudel, N., Kleber, G., Behrmann, C., Lotterer, E., & Fleig, W. E. (2000) · Journal of Hepatology · doi:10.1016/s0168-8278(00)80093-8 · Cited by 38
Hsieh, Y., Lin, K., Korivi, M., Lee, T., Wu, C., & Wu, K. (2014) · International Journal of Molecular Sciences · doi:10.3390/ijms15046504 · Cited by 38
The Determination of Muscle Volume with A Freehand 3D Ultrasonography System
Weller, R., Pfau, T., Ferrari, M., Griffith, R., Bradford, T., & Wilson, A. M. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.08.007 · Cited by 38
Fluorescein-labeled sinistrin as marker of glomerular filtration rate
Pill, J., Kraenzlin, B., Jander, J., Sattelkau, T., Sadick, M., Klötzer, H.-M., Deus, C., Kraemer, U., & Gretz, N. (2005) · European Journal of Medicinal Chemistry · doi:10.1016/j.ejmech.2005.03.020 · Cited by 38
The Effect of Fixation and Histological Preparation on Coronary Artery Dimensions
Choy, J. S., Mathieu-Costello, O. A., & Kassab, G. S. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-4854-4 · Cited by 38
Lehnert, M., Clarke, D. D., Gibbons, J. G., Ward, L. C., Golding, S. M., Shepherd, R. W., Cornish, B., & Crawford, D. H. (2001) · Nutrition · doi:10.1016/s0899-9007(00)00473-1 · Cited by 40
Validation of a commercial software package for quantification of computer use
Blangsted, A. K., Hansen, K., & Jensen, C. (2004) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2004.04.003 · Cited by 38
Visual acuity assessment: a comparison of two tests for measuring children's vision
JONES, D. A., Westall, C. A., Averbeck, K., & Abdolell, M. (2003) · Ophthalmic and Physiological Optics · doi:10.1046/j.1475-1313.2003.00150.x · Cited by 38
Quantitative assessment of left ventricular function in humans at 7 T
Brandts, A., Westenberg, J. J. M., Versluis, M. J., Kroft, L. J. M., Smith, N. B., WEBB, A. G., & Roos, A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22529 · Cited by 38
The Bandim tuberculosis score: Reliability and comparison with the Karnofsky performance score
Rudolf, F., Joaquím, L. C., Vieira, C. S., Bjerregaard-Andersen, M., Andersen, A., Erlandsen, M., Sodemann, M., Andersen, P. L., & Wejse, C. M. (2012) · Scandinavian Journal of Infectious Diseases · doi:10.3109/00365548.2012.731077 · Cited by 39
High test–retest reliability of checkerboard reversal visual evoked potentials (VEP) over 8 months
Sarnthein, J., Andersson, M., Zimmermann, M. B., & Zumsteg, D. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.08.014 · Cited by 38
Errors in measuring blood gases in the intensive care unit: Effect of delay in estimation
Woolley, A., & Hickling, K. G. (2003) · Journal of Critical Care · doi:10.1053/jcrc.2003.yjcrc7 · Cited by 38
Rech, C. R., Cordeiro, B. A., Petróski, E. L., & de Vasconcelos, F. D. A. G. (2008) · Arquivos Brasileiros de Endocrinologia & Metabologia · doi:10.1590/s0004-27302008000700013 · Cited by 42
Moore, A. E. B., Blake, G. M., & Fogelman, I. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.048595 · Cited by 38
Hergan, K., Schuster, A. H., Frühwald, J., Mair, M. H., Burger, R., & Töpker, M. (2007) · European Journal of Radiology · doi:10.1016/j.ejrad.2007.03.031 · Cited by 38
Determination of peak oxygen uptake during upper body exercise
Price, M., & CAMPBELL, I. G. (1997) · Ergonomics · doi:10.1080/001401397188116 · Cited by 51
Liao, Y., Liao, W., Liu, J., Xu, G., & Zeng, R. (2011) · Journal of International Medical Research · doi:10.1177/147323001103900624 · Cited by 38
Exercise echocardiography reflects cumulative anthracycline exposure during childhood
Smibert, E., Carlin, J. B., Vidmar, S., Wilkinson, L. C., Newton, M., & Weintraub, R. G. (2004) · Pediatric Blood & Cancer · doi:10.1002/pbc.20016 · Cited by 38
The Effect of Aging on Venous Valves
van Langevelde, K., Šrámek, A., & Rosendaal, F. R. (2010) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.110.209049 · Cited by 38
Evaluation of enamel micro-cracks characteristics after removal of metal brackets in adult patients
Dumbrytė, I., Linkevičienė, L., Malinauskas, M., Linkevičius, T., Pečiulienė, V., & Tikuišis, K. K. (2011) · European Journal of Orthodontics · doi:10.1093/ejo/cjr137 · Cited by 38
Aggarwal, A. N., Gupta, D., Behera, D., & Jindal, S. K. (2006) · Respiratory Care · doi:10.4187/respcare.06510737 · Cited by 38
Agreement between auricular and rectal measurements of body temperature in healthy cats
Sousa, M. G., Carareto, R., Pereira-Junior, V. A., & Aquino, M. C. C. (2012) · Journal of Feline Medicine and Surgery · doi:10.1177/1098612x12464873 · Cited by 45
Pedometer accuracy during stair climbing and bench stepping exercises.
Ayabe, M., Aoki, J., Ishii, K., Takayama, K., & Tanaka, H. (2008) · Europe PMC (PubMed Central) · Cited by 47
Kloor, D., Yao, K., Delabar, U., & Oßwald, H. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.4.537 · Cited by 38
Correnti, A. J., Wollstein, G., Price, L. L., & Schuman, J. S. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00496-2 · Cited by 40
Moy, K. L., Scragg, R. K. R., McLean, G., & Carr, H. (2008) · Journal of Physical Activity and Health · doi:10.1123/jpah.5.s1.s45 · Cited by 46
Anatomic M-mode: a new technique for quantitative assessment of left ventricular size and function
Mele, D., Pedini, I., Alboni, P., & Levine, R. A. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00060-5 · Cited by 38
Follan, M., Anderson, S. M., Huline‐Dickens, S., Lidstone, E., Young, D., Brown, G., & Minnis, H. (2011) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2010.12.031 · Cited by 45
Arterial Wave Reflections During the Menstrual Cycle of Healthy Women: A Reproducibility Study
Papaioannou, T. G., Stamatelopoulos, K., Georgiopoulos, G., Vlachopoulos, C. V., Georgiou, S., Lykka, M., Lambrinoudaki, I. V., Papamichael, C. M., & Stefanadis, C. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.137703 · Cited by 43
Berkenbosch, J. W., & Tobias, J. D. (2006) · Respiratory Care · doi:10.4187/respcare.06510726 · Cited by 38
Poutanen, T., IKONEN, A., JOKINEN, E., VAINIO, P., & TIKANOJA, T. (2001) · European Journal of Echocardiography · doi:10.1016/s1525-2167(00)90054-4 · Cited by 38
Dyer, R. A., Piercy, J. L., Reed, A. R., Strathie, G. W., Lombard, C. J., Anthony, J., & James, M. F. (2010) · British Journal of Anaesthesia · doi:10.1093/bja/aeq292 · Cited by 38
Nevill, A. M., Metsios, G. S., Jackson, A. S., Wang, J., Thornton, J., & Gallagher, D. (2008) · PubMed · Cited by 49
Stolwijk-Swüste, J. M., Beelen, A., Lankhorst, G. J., & Nollet, F. (2008) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0188 · Cited by 38
PR interval: A comparison of electrical and mechanical methods in the fetus
Pasquini, L., Seale, A. N., Belmar, C., Oseku‐Afful, S., Thomas, M. J., Taylor, M. J. O., Roughton, M., & Gardiner, H. M. (2006) · Early Human Development · doi:10.1016/j.earlhumdev.2006.05.020 · Cited by 38
Torrao, N. A., Hetem, R. S., Meyer, L. C. R., & Fick, L. G. (2011) · Veterinary Record · doi:10.1136/vr.c6200 · Cited by 49
Non-invasive monitoring of CO2 levels in patients using NIV for AECOPD
Cox, M., Kemp, R., Anwar, S., Athey, V., Aung, T., & Moloney, E. D. (2006) · Thorax · doi:10.1136/thx.2005.051664 · Cited by 38
Timon, C., Astell, A. J., Hwang, F., Adlam, T. D., Smith, T., MacLean, L., Spurr, D., Forster, S. E., & Williams, E. A. (2015) · British Journal Of Nutrition · doi:10.1017/s0007114514003808 · Cited by 42
MR Elastography of the Liver: Defining Thresholds for Detecting Viscoelastic Changes
Bohte, A. E., Garteiser, P., Niet, A. D., Groot, P. F. C., Sinkus, R., Stoker, J., & Nederveen, A. J. (2013) · Radiology · doi:10.1148/radiol.13122669 · Cited by 39
Reliability of a method to conduct upper airway analysis in cone-beam computed tomography
de Souza, K. R. S., Oltramari-Navarro, P. V. P., Navarro, R. D. L., Conti, A. C. D. C. F., & de Almeida, M. R. (2013) · Brazilian Oral Research · doi:10.1590/s1806-83242013000100009 · Cited by 38
The Role of Notational Analysis in Soccer Coaching
James, N. (2006) · International Journal of Sports Science & Coaching · doi:10.1260/174795406777641294 · Cited by 38
Sperandio, I., Kaderali, S., Chouinard, P. A., Frey, J., & Goodale, M. A. (2013) · Journal of Neuroscience · doi:10.1523/jneurosci.0977-13.2013 · Cited by 43
van der Weerdt, A. P., Klein, L. J., Visser, C. A., Visser, F. C., & Lammertsma, A. A. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-0772-y · Cited by 43
Smith, K., Flicker, L. A., Dwyer, A., Marsh, G., Mahajani, S., Almeida, O. P., Lautenschlager, N. T., Atkinson, D. N., & LoGiudice, D. (2009) · Australian Psychologist · doi:10.1080/00050060802563463 · Cited by 38
Point‐of‐care testing of HbA1c and blood glucose in a remote Aboriginal Australian community
Martin, D. D., Jones, T. W., Davis, E. A., Shephard, M. D. S., Freeman, H., Maguire, G. P., & Bulsara, M. K. (2005) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.2005.tb00019.x · Cited by 38
Gauss, T., Hamada, S., Jurcisin, I., Dahmani, S., Boudaoud, L., Mantz, J., & Paugam‐Burtz, C. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aet384 · Cited by 38
Birth Weight and Creatinine Clearance in Young Adult Twins
Gielen, M., Pinto‐Sietsma, S., Zeegers, M. P., Loos, R. J. F., Fagard, R. H., de Leeuw, P. W., Beunen, G. P., Derom, C. A., & VLIETINCK, R. F. (2005) · Journal of the American Society of Nephrology · doi:10.1681/asn.2004030210 · Cited by 38
A Novel Method to Estimate Iliac Tortuosity in Evaluating EVAR Access
Kristmundsson, T., Sonesson, B., & Resch, T. A. (2012) · Journal of Endovascular Therapy · doi:10.1583/11-3704.1 · Cited by 39
Chuang, L.-L., Wu, C., Lin, K., & Hsieh, C.-J. (2013) · Physical Therapy · doi:10.2522/ptj.20120422 · Cited by 50
Havalad, S., Quaid, M. A., & Sapiega, V. (2006) · Nutrition in Clinical Practice · doi:10.1177/0115426506021002175 · Cited by 39
Haber, M., & Barnhart, H. X. (2007) · Statistical Methods in Medical Research · doi:10.1177/0962280206075527 · Cited by 38
Cheng, G., Campbell, A. P., Xie, H., Stednick, Z. J., Callais, C., Leisenring, W. M., Englund, J. A., Chien, J. W., & Boeckh, M. (2015) · Transplantation and Cellular Therapy · doi:10.1016/j.bbmt.2015.12.023 · Cited by 38
Sjörs, C., Raposo, S. E., Sjölander, A., Bälter, O., Hedenus, F., & Bälter, K. A. (2016) · Environmental Health · doi:10.1186/s12940-016-0110-7 · Cited by 45
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.