STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 14,201–14,300 of 47,868
Selleri, P., Girolamo, N. D., & Novari, G. (2014) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.245.1.87 · Cited by 40
Ear length in trisomy 21 fetuses at 11–14 weeks of gestation
Sacchini, C., El-Sheikhah, A., Cicero, S., Rembouskos, G., & Nicolaides, K. H. (2003) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.903 · Cited by 35
Ohno, Y., Nishio, M., Koyama, H., Yoshikawa, T., Matsumoto, S., Seki, S., Tsubakimoto, M., & Sugimura, K. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.11.001 · Cited by 35
McEvoy, C. T., Cran, G. W., Cooke, S. R., & Young, I. S. (2009) · Clinical Nutrition · doi:10.1016/j.clnu.2009.04.009 · Cited by 40
Ymeti, A., Li, X., Lunter, B., Breukers, C., Tibbe, A. G. J., Terstappen, L. W. M. M., & Greve, J. (2007) · Cytometry Part A · doi:10.1002/cyto.a.20375 · Cited by 35
Longitudinal changes in submaximal oxygen uptake in 11- to 13-year-olds
Welsman, J. R., & Armstrong, N. (2000) · Journal of Sports Sciences · doi:10.1080/026404100365081 · Cited by 35
Heuft-Dorenbosch, L., Vosse, D., Landewé, R., Spoorenberg, A. J. P. L., Dougados, M., Mielants, H., van der Tempel, H., van der Linden, S., & van der Heijde, D. M. F. M. (2004) · PubMed · Cited by 35
García‐Álvarez, A., Fernández‐Friera, L., Lau, J. F., Sawit, S. T., Mirelis, J. G., Castillo, J. G., Pinney, S., Anyanwu, A., Fuster, V., Sanz, J., et al. (2011) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2011.03.009 · Cited by 35
Freund, W., Weber, F., Billich, C., & Schütz, U. H. W. (2012) · BMJ Open · doi:10.1136/bmjopen-2012-001118 · Cited by 35
An Adaptive Algorithm for Eye-Gaze-Tracking-Device Calibration
Ramdane-Cherif, Z., & Naït-Ali, A. (2008) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.913590 · Cited by 35
Assessment of coronary flowreserve by coronary pressure measurement
Akasaka, T., Yamamuro, A., Kamiyama, N., Koyama, Y., Akiyama, M., Watanabe, N., Neishi, Y., Takagi, T., Shalman, E., Barak, C., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00258-4 · Cited by 35
Helle-Valle, T. M., Remme, E. W., Lyseggen, E., Pettersen, E., Vartdal, T., Opdahl, A., Smith, H., Osman, N. F., Ihlen, H., Edvardsen, T., et al. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01116.2008 · Cited by 35
Campbell, D. E., Raftery, N., Tustin, R., Tustin, N. B., DeSilvio, M., Cnaan, A., Aye, P. P., Lackner, A. A., & Douglas, S. D. (2006) · Clinical and Vaccine Immunology · doi:10.1128/cvi.00174-06 · Cited by 35
Byström, S., Jensen, B. R., Jensen‐Urstad, M., Lindblad, L. E., & Kilbom, Å. (1998) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519850186193 · Cited by 35
Amal, L., Philippe, M., Lali, S., Wallemacq, P. E., & Maisin, D. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.059 · Cited by 35
Repeatability of Oculus Pentacam Metrics Derived From Corneal Topography
Miranda, M. A., Radhakrishnan, H., & O’Donnell, C. (2009) · Cornea · doi:10.1097/ico.0b013e31819b01b5 · Cited by 37
Spannow, A. H., Stenboeg, E., Pfeiffer‐Jensen, M., & Herlin, T. (2007) · Pediatric Rheumatology · doi:10.1186/1546-0096-5-3 · Cited by 35
Renal functional reserve in patients with severe chronic obstructive pulmonary disease
Sharkey, R., Mulloy, E., Kilgallen, I., & O'Neill, S. J. (1997) · Thorax · doi:10.1136/thx.52.5.411 · Cited by 35
Can Persistence Hunting Signal Male Quality? A Test Considering Digit Ratio in Endurance Athletes
Longman, D. P., Wells, J. C. K., & Stock, J. T. (2015) · PLoS ONE · doi:10.1371/journal.pone.0121560 · Cited by 41
Pallin, M., O'hare, E., Zaffaroni, A., Boyle, P., Fagan, C., Kent, B., Heneghan, C., de Chazal, P., & McNicholas, W. T. (2014) · Journal of Sleep Research · doi:10.1111/jsr.12126 · Cited by 36
Automatic Detection and Quantification of Tree-in-Bud (TIB) Opacities From CT Scans
Bağcı, U., Yao, J., Wu, A., Caban, J. J., Palmore, T. N., Suffredini, A. F., Aras, Ö., & Mollura, D. J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2190984 · Cited by 35
The Ear as an Alternative Site for a Pulse Oximeter Finger Clip Sensor
Haynes, J. M. (2007) · Respiratory Care · doi:10.4187/respcare.07520727 · Cited by 35
Sleep staging and respiratory events in refractory epilepsy patients: Is there a first night effect?
Selwa, L. M., Marzec, M. L., Chervin, R. D., Weatherwax, K. J., Vaughn, B. V., Foldvary‐Schaefer, N., Wang, L., Song, Y., & Malow, B. A. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2008.01681.x · Cited by 35
Benlian, P., Cansier, C., Hennache, G., Khallouf, O., Bayer, P., Duron, F., Carrat, F., Couderc, R., Chazouillères, O., Bardet, J., et al. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.4.493 · Cited by 35
Tang, J. E., Mandrusiak, A., & Russell, T. G. (2012) · International Journal of Telemedicine and Applications · doi:10.1155/2012/798791 · Cited by 42
Serial Determinations of Absolute Plasma Volume with Indocyanine Green during Hemodialysis
Mitra, S., Chamney, P. W., Greenwood, R. N., & Farrington, K. (2003) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000082998.50730.fa · Cited by 40
Chan, D. D., & Neu, C. P. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24757 · Cited by 35
Genetic Analysis of Blood Pressure in 8 Mouse Intercross Populations
Feng, M., Deerhake, M. E., Keating, R., Thaisz, J., Xu, L., Tsaih, S., Smith, R., Ishige, T., Sugiyama, F., Churchill, G. A., et al. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.134569 · Cited by 35
Intrapartum Measurement of Cervical Dilatation Using Translabial 3-Dimensional Ultrasonography
Zimerman, A. L., Smolin, A., Maymon, R., Weinraub, Z., Herman, A., & Tobvin, Y. (2009) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2009.28.10.1289 · Cited by 35
Engvall, J. E., Sonnhag, C., Nylander, E., Stenport, G., Karlsson, E., & Wranne, B. (1995) · Heart · doi:10.1136/hrt.73.3.270 · Cited by 35
Park, Y. S., Park, J., Ahn, K. T., Jang, W. I., Park, H. S., Kim, J. H., Lee, J., Choi, S. W., Jeong, J., & Seong, I. W. (2010) · Journal of Cardiovascular Ultrasound · doi:10.4250/jcu.2010.18.1.1 · Cited by 35
Medeiros, A. I. A., Marcelino, R., Mesquita, I., & Andrés, J. M. P. (2014) · PubMed Central · Cited by 35
Guggenberger, R., Nanz, D., Bussmann, L., Chhabra, A. B., Fischer, M. A., Hodler, J., Pfirrmann, C. W. A., & Andreisek, G. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.05.011 · Cited by 35
van Weely, S. F. E., van Denderen, C. J., van der Horst-Bruinsma, I. E., Nurmohamed, M. T., Dijkmans, B. A. C., Dekker, J., & Steultjens, M. P. M. (2009) · Rheumatology · doi:10.1093/rheumatology/kep190 · Cited by 44
Maxillary Anterior Tooth Size and Arch Dimensions in Unilateral Cleft Lip and Palate
Lewis, B. R., Stern, M. R., & Willmot, D. R. (2008) · The Cleft Palate-Craniofacial Journal · doi:10.1597/07-078.1 · Cited by 35
Residual Gravimetric Method to Measure Nebulizer Output
None, L. V., Grimbert, D., Bordenave, J., Benoît, G., Furet, Y., Fauroux, B., Boissinot, E., Monte, M. D., Lemarié, É., & Diot, P. (2004) · Journal of Aerosol Medicine · doi:10.1089/089426804322994479 · Cited by 35
Use of a short-term isotope-dilution method for determining the vitamin A status of children
Tang, G., Qin, J., Hao, L.-Y., Yin, S., & Russell, R. M. (2002) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/76.2.413 · Cited by 35
Winfield, J. M., Collins, D. J., Priest, A. N., Quest, R. A., Glover, A., Hunter, S., Morgan, V. A., Freeman, S. J., Rockall, A., & deSouza, N. M. (2015) · Medical Physics · doi:10.1118/1.4937789 · Cited by 35
Baker, F. A., Silverman, M. J., & MacDonald, R. (2015) · Journal of Music Therapy · doi:10.1093/jmt/thv020 · Cited by 42
Changes in the Objective Amplitude of Accommodation with Pupil Size
Lara, F. J., Bernal‐Molina, P., Fernández‐Sánchez, V., & López‐Gil, N. (2014) · Optometry and Vision Science · doi:10.1097/opx.0000000000000383 · Cited by 37
Central and Peripheral Autorefraction Repeatability in Normal Eyes
Moore, K. E., & Berntsen, D. A. (2014) · Optometry and Vision Science · doi:10.1097/opx.0000000000000351 · Cited by 35
Comparison of Corneal Diameter and Anterior Chamber Depth Measurements Using 4 Different Devices
Shajari, M., Lehmann, U. C., & Kohnen, T. (2016) · Cornea · doi:10.1097/ico.0000000000000840 · Cited by 35
Commutability of Cytomegalovirus WHO International Standard in Different Matrices
Jones, S., Webb, E. M., Barry, C. P., Choi, W. S., Abravaya, K., Schneider, G. J., & Ho, S. Y. (2016) · Journal of Clinical Microbiology · doi:10.1128/jcm.03292-15 · Cited by 35
Ferring, M., Reber, G., de Moerloose, P., Merlani, P. G., Diby, M., & Ricou, B. (2001) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03020384 · Cited by 35
Tajali, S. B., MacDermid, J. C., Grewal, R. S., & Young, C. (2016) · The Open Orthopaedics Journal · doi:10.2174/1874325001610010190 · Cited by 35
Balogh, Á. L., Peták, F., Fodor, G. H., Tolnai, J., Csorba, Z., & Babik, B. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew127 · Cited by 35
Right Heart Hemodynamics in Pulmonary Hypertension – An Echocardiography and Catheterization Study –
Doutreleau, S., Canuet, M., Enache, I., Marco, P. D., Lonsdorfer‐Wolf, E., Oswald-Mammoser, M., & Charloux, A. (2016) · Circulation Journal · doi:10.1253/circj.cj-16-0206 · Cited by 35
Inter-rater reliability of shoulder measurements in middle-aged women
Groef, A. D., Kampen, M. V. D., Vervloesem, N., Clabau, E., Christiaens, M.-R., Neven, P., Geraerts, I., Struyf, F., & Devoogdt, N. (2016) · Physiotherapy · doi:10.1016/j.physio.2016.07.002 · Cited by 44
Ma, D., Chen, C., Liang, J., Lu, Z., Chen, H., & Zhang, M. (2016) · Scientific Reports · doi:10.1038/srep35187 · Cited by 35
Liisberg, M., Diederichsen, A. C. P., & Lindholt, J. S. (2017) · BMC Medical Imaging · doi:10.1186/s12880-017-0186-8 · Cited by 35
Studt, J., Alberio, L., Angelillo‐Scherrer, A., Asmis, L. M., Fontana, P., Korte, W. C., Mendez, A., Schmid, P., Stricker, H. J., Tsakiris, D. A., et al. (2017) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.13747 · Cited by 35
Kamphuis, V. P., Westenberg, J. J. M., van der Palen, R. L. F., van den Boogaard, P. J., van der Geest, R. J., Roos, A., Blom, N. A., Roest, A. A. W., & Elbaz, M. S. M. (2018) · International journal of cardiac imaging · doi:10.1007/s10554-017-1291-z · Cited by 37
Thakran, S., Chatterjee, S., Singhal, M., Gupta, R. K., & Singh, A. (2018) · PLoS ONE · doi:10.1371/journal.pone.0190348 · Cited by 39
Baillet, P., Cadiot, G., Goutte, M., Goutorbe, F., Brixi, H., Hoeffel, C. C., Allimant, C., Reymond, M., Obritin, H., Magnin, B., et al. (2018) · World Journal of Gastroenterology · doi:10.3748/wjg.v24.i5.641 · Cited by 35
Smartphone applications validated for joint angle measurement: a systematic review
Longoni, L., Brunati, R., Sale, P., Casale, R., Ronconi, G., & Ferriero, G. (2019) · International Journal of Rehabilitation Research · doi:10.1097/mrr.0000000000000332 · Cited by 35
Lee, W. I., Park, Y., Park, J., Shrivastava, S., Son, Y.-M., Choi, H.-J., Lee, J., Jeon, B., Lee, H., & Lee, N. (2019) · Lab on a Chip · doi:10.1039/c8lc01344f · Cited by 37
Validity of the Supramaximal Test to Verify Maximal Oxygen Uptake in Children and Adolescents
Sansum, K. M., Weston, M. E., Bond, B., Cockcroft, E., O’Connor, A., Tomlinson, O. W., Williams, C. A., & BARKER, A. R. (2019) · Pediatric Exercise Science · doi:10.1123/pes.2018-0129 · Cited by 40
Increased extracellular volume in the liver of pediatric Fontan patients
de Lange, C., Reichert, M. J. E., Pagano, J. J., Seed, M., Yoo, S., Broberg, C. S., Lam, C. Z., & Grosse‐Wortmann, L. (2019) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-019-0545-4 · Cited by 35
Luque, V., Closa‐Monasterolo, R., Rubio-Torrents, C., Zaragoza-Jordana, M., Ferré, N., Gispert‐Llauradó, M., Escribano, J., & for the European Childhood Obesity Project Group (2014) · Annals of Nutrition and Metabolism · doi:10.1159/000356450 · Cited by 41
Transthoracic Echocardiographic Measurement of Patent Ductus Arteriosus in Dogs
Schneider, M., Hildebrandt, N., Schweigl, T., & Wehner, M. (2007) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2007.tb02957.x · Cited by 35
Huijgen, H. J., Sanders, R., van Olden, R. W., Klous, M. G., Gaffar, F. R., & Sanders, G. T. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.3.639 · Cited by 35
The distal radius and ulna classification in assessing skeletal maturity
Cheung, J. P. Y., Samartzis, D., Cheung, P. W. H., Leung, K. H., Cheung, K., & Luk, K. D. K. (2015) · Journal of Pediatric Orthopaedics B · doi:10.1097/bpb.0000000000000214 · Cited by 35
BLIJENBERG, B. G., Yurdakul, G., van Zelst, B. D., Bangma, C. H., Wildhagen, M. F., & Schröder, F. H. (2001) · British Journal of Urology · doi:10.1046/j.1464-410x.2001.02374.x · Cited by 35
Chaffin, M. K., Matthews, N. S., Cohen, N. D., & CARTER, G. K. (1996) · Equine Veterinary Journal · doi:10.1111/j.2042-3306.1996.tb01615.x · Cited by 35
Noninvasive Assessment of Inspiratory Muscle Function during Exercise
Hayot, M., Ramonatxo, M., Matecki, S., Milic‐Emili, J., & PREFAUT, C. G. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.6.9912053 · Cited by 35
A Statistical Analysis of the Accuracy of Sonography of the Patellar Tendon
Roberts, C. S., King, D. H., & Goldsmith, L. J. (1999) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(99)70056-3 · Cited by 35
Direct agglutination test and other assays for measuring antibodies to Toxoplasma gondii.
Johnson, J. D., Duffy, K., New, L., Holliman, R. E., Chessum, B. S., & Fleck, D. G. (1989) · Journal of Clinical Pathology · doi:10.1136/jcp.42.5.536 · Cited by 35
Validation of a 7-day physical activity diary against doubly-labelled water
Rush, E. C., Valencia, M. E., & Plank, L. D. (2008) · Annals of Human Biology · doi:10.1080/03014460802089825 · Cited by 46
Mahnken, A. H., Wildberger, J. E., Sinha, A. M. S., Dedden, K., Stanzel, S. F., Hoffmann, R., Schmitz‐Rode, T., & Günther, R. W. (2003) · Acta Radiologica · doi:10.1034/j.1600-0455.2003.00057.x · Cited by 35
Impaired Accommodation of Proximal Stomach in Patients with Alcoholic Liver Cirrhosis
Izbéki, F., Kiss, I., Wittmann, T., Várkonyi, T. T., Légrády, P., & Lonovics, J. (2002) · Scandinavian Journal of Gastroenterology · doi:10.1080/003655202762671279 · Cited by 35
Ambrosini, G. L., de Klerk, N. H., Musk, A. W., & Mackerras, D. (2001) · Public Health Nutrition · doi:10.1079/phn200062 · Cited by 35
Suzuki, J., Sakamoto, T., Takenaka, K., Kawakubo, K., Amano, K., Takahashi, H. E., Hasegawa, I., Shiota, T., Hada, Y., & Sugimoto, T. (1988) · Heart · doi:10.1136/hrt.60.5.440 · Cited by 35
Stewart, S. F. C., Nast, E. P., Arabía, F. A., TALBOT, T. L., Proschan, M. A., & Clark, R. E. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90801-f · Cited by 35
Colombo, R., Mazzini, L., Mora, G., Parenzan, R., Creola, G., Pirali, I., & Minuco, G. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00024-2 · Cited by 35
Energy Expenditure of the Physical Activity across the Curriculum Intervention
HONAS, J. J., WASHBURN, R. A., SMITH, B. K., GREENE, J. L., & DONNELLY, J. E. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31816d6591 · Cited by 34
Validation of PD Adequest 2.0 for pediatric dialysis patients
Warady, B. A., Watkins, S. L., Fivush, B. A., Andreoli, S. P., Salusky, I. B., Kohaut, E. C., & Vonesh, E. F. (2001) · Pediatric Nephrology · doi:10.1007/s004670000513 · Cited by 35
Brunner, H. I., Jones, O. Y., Lovell, D. J., Johnson, A. M., Alexander, P., & Klein‐Gitelman, M. S. (2003) · Lupus · doi:10.1191/0961203303lu430oa · Cited by 36
Agreement between capillary and arterial lactate in the newborn
Fauchère, J., Bauschatz, A., Arlettaz, R., Zimmermann‐Bär, U., & Bucher, H. (2002) · Acta Paediatrica · doi:10.1111/j.1651-2227.2002.tb01645.x · Cited by 35
Pressure Phosphene Self-Tonometry: A Comparison with Goldmann Tonometry in Glaucoma Patients
Lam, D. S. C., Leung, D. Y. L., Chiu, T. Y. H., Fan, D. S. P., Cheung, E. Y. Y., Wong, T. Y., Lai, J. S. M., & Tham, C. C. Y. (2004) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-0115 · Cited by 35
Hatab, M. R., Giller, C. A., & Clarke, G. D. (1997) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00030-6 · Cited by 36
Samstad, S. O., Hegrenaes, L., Skjærpe, T., & Hatle, L. K. (1989) · Heart · doi:10.1136/hrt.61.4.336 · Cited by 35
Mid‐second trimester measurement of fetal nasal bone length in the Japanese population
Kanagawa, T., Fukuda, H., Kinugasa, Y., Mihyon, S., Shimoya, K., Murata, Y., Yokoyama, T., Hashimoto, H., Isaka, S., & Nagamatsu, M. (2006) · Journal of obstetrics and gynaecology research · doi:10.1111/j.1447-0756.2006.00429.x · Cited by 35
Deng, J., Virmani, S., Young, J. Y., Harris, K. R., Yang, G., RADEMAKER, A. W., Woloschak, G. E., Omary, R. A., & Larson, A. C. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21327 · Cited by 35
Williams, R. I., Payne, N., Phillips, T., D’hooge, J., & Fraser, A. G. (2005) · Heart · doi:10.1136/hrt.2003.027490 · Cited by 35
Transoesophageal echocardiography accurately detects cardiac output variation
Parra, V., Fita, G., Rovira, I., Matute, P., Gomar, C. G., & Paré, C. (2007) · European Journal of Anaesthesiology · doi:10.1017/s0265021507001354 · Cited by 35
Zucconi, M., Ferini‐Strambi, L., Castronovo, V., Oldani, A., & Smirne, S. (1996) · European Respiratory Journal · doi:10.1183/09031936.96.09061251 · Cited by 35
Tan, P. C., Pickles, M. D., Lowry, M., Manton, D. J., & Turnbull, L. W. (2007) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.04.002 · Cited by 35
Diehm, N., Kickuth, R., Gahl, B., Do, D.-D., Schmidli, J., Rattunde, H., Baumgärtner, I., & Dick, F. (2007) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2006.10.004 · Cited by 35
Home Oximetry Studies for Diagnosis of Sleep Apnea/Hypopnea Syndrome
Wiltshire, N., Kendrick, A. H., & Catterall, J. R. (2001) · CHEST Journal · doi:10.1378/chest.120.2.384 · Cited by 35
Nissman, S. A., Tractenberg, R. E., Saba, C. M., Douglas, J. C., & Lustbader, J. M. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2005.12.021 · Cited by 35
Vogeser, M., Groetzner, J., Küpper, C., & Briegel, J. (2003) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2003.024 · Cited by 35
Gender influence on jejunal migrating motor complex
Aytuğ, N. ̇., Giral, A., I˙meryüz, N., Enc, F. Y., ̇roğlu, N. B., Aktaş, G., & Ulusoy, N. B. (2001) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.2001.280.2.g255 · Cited by 35
Pereira, P. M. G., Oliveira, E., & Rosado, P. (2006) · PubMed · Cited by 39
Comparison of industrial hygienists' exposure evaluations for an epidemiologic study
Stewart, P. A., Carel, R. S., Schairer, C., & Blair, A. E. (2000) · Scandinavian Journal of Work Environment & Health · doi:10.5271/sjweh.509 · Cited by 38
Reproducibility of three different methods of measuring baroreflex sensitivity in normal subjects
LORD, S. W., Clayton, R. H., Hall, M., Gray, J., Murray, A., McComb, J. M., & Kenny, R. A. (1998) · Clinical Science · doi:10.1042/cs0950575 · Cited by 35
Strong Ion Calculator - A Practical Bedside Application of Modern Quantitative Acid-Base Physiology
Lloyd, P. (2004) · Critical Care and Resuscitation · doi:10.1016/s1441-2772(23)01698-8 · Cited by 42
Williams, M. J. A., Stewart, R., Low, C. J. S., & WILKINS, G. T. (1999) · International journal of cardiac imaging · doi:10.1023/a:1006279228534 · Cited by 35
Kiatchoosakun, S., Kirkpatrick, D. L., & Hoit, B. D. (2001) · PubMed · Cited by 35
Measurement of functional residual capacity by nitrogen washout during partial ventilatory support
Zinserling, J., Wrigge, H., Varelmann, D. J., Hering, R., & Putensen, C. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1677-3 · Cited by 35
Evaluation of the quality of bedside monitoring of the blood glucose level in a teaching hospital.
Ting, C.-M., & Nanji, A. A. (1988) · Europe PMC (PubMed Central) · Cited by 35
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.