STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 14,101–14,200 of 47,868
Škarabot, J., Balshaw, T. G., Maeo, S., Massey, G. J., Lanza, M. B., Maden‐Wilkinson, T., & Folland, J. P. (2021) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00094.2021 · Cited by 40
A computer vision-based mobile tool for assessing human posture: A validation study
Moreira, R., Fialho, R., Teles, A. S., Bordalo, V., Vasconcelos, S. S., Gouveia, G. P. D. M., Bastos, V. H., & Teixeira, S. S. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106565 · Cited by 35
Hubaut, R., Guichard, R., Greenfield, J., & Blandeau, M. (2022) · Sensors · doi:10.3390/s22020436 · Cited by 35
Derstine, B. A., Holcombe, S. A., Ross, B. E., Wang, N. C., Wang, S. C., & Su, G. L. (2022) · Scientific Reports · doi:10.1038/s41598-022-06232-5 · Cited by 39
Cheng, S., Zhang, J., Shao, X. H., Wu, Z.-T., Li, T., Po, W., Lin, J., & Yu, A. (2022) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-022-05579-9 · Cited by 35
Subcutaneous and visceral fat assessment by DXA and MRI in older adults and children
Maskarinec, G., Shvetsov, Y. B., Wong, M. C., Garber, A. K., Monroe, K. R., Ernst, T., Buchthal, S. D., Lim, U., Marchand, L. L., Heymsfield, S. B., et al. (2022) · Obesity · doi:10.1002/oby.23381 · Cited by 38
Galzignato, A., Lupardi, E., Hoffer, K. J., Barboni, P., Schiano‐Lomoriello, D., & Savini, G. (2022) · Journal of Cataract & Refractive Surgery · doi:10.1097/j.jcrs.0000000000001023 · Cited by 35
Graybeal, A. J., Brandner, C. F., & Tinsley, G. M. (2022) · Clinical Nutrition · doi:10.1016/j.clnu.2022.09.014 · Cited by 39
Ibrahim, G. M., Weidauer, S., & Macdonald, R. L. (2011) · Journal of neurosurgery · doi:10.3171/2011.7.jns11725 · Cited by 35
Kristensen, M. T., Henriksen, S., Stie, S. B., & Bandholm, T. (2011) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2010.03293.x · Cited by 35
Development and validation of a novel tool to estimate peri‐operative blood loss*
Stahl, D., Groeben, H., Kroepfl, D., Gautam, S., & Eikermann, M. (2012) · Anaesthesia · doi:10.1111/j.1365-2044.2011.06916.x · Cited by 35
Chaturvedi, D., Vilhekar, K. Y., Chaturvedi, P., & Bharambe, M. S. (2004) · PubMed · Cited by 35
Smith, D. C., Engel, B., Diskin, A. M., Španěl, P., & Davies, S. (2002) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/76.6.1295 · Cited by 38
Point‐of‐care reversal treatment in phenprocoumon‐related intracerebral hemorrhage
Rizos, T., Jenetzky, E., Herweh, C., Hug, A., Hacke, W., Steiner, T., & Veltkamp, R. C. (2010) · Annals of Neurology · doi:10.1002/ana.21965 · Cited by 35
Chung, J. W. N. C. H. F., Bohnen, A. M., Pel, J. J. M., Bosch, J. L. H. R., Niesing, R., & van MASTRIGT, R. (2004) · Urology · doi:10.1016/j.urology.2003.08.030 · Cited by 35
Non-enhanced MR angiography of renal arteries: comparison with contrast-enhanced MR angiography
Angeretti, M., Lumia, D., Canì, A., Barresi, M., Cardim, L. N., Piacentino, F., Maresca, A. M., Novario, R., Genovese, E., & Fugazzola, C. (2013) · Acta Radiologica · doi:10.1177/0284185113482690 · Cited by 35
Body composition in underweight elderly subjects: reliability of bioelectrical impedance analysis
Lupoli, L., Sergi, G., Coin, A., Perissinotto, E., Volpato, S., Busetto, L., Inelmen, E. M., & Enzi, G. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.05.005 · Cited by 50
Pieper, C. C., Grötz, S., Nadal, J., Schild, H. H., & Niggemann, P. (2013) · European Spine Journal · doi:10.1007/s00586-013-2932-0 · Cited by 35
3‐Min step test and treadmill exercise for evaluating exercise-induced asthma
Tancredi, G., Quattrucci, S., Scalercio, F., Castro, G. D., Zicari, A. M., Bonci, E., Cingolani, S., Indinnimeo, L., & Midulla, F. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00039704 · Cited by 37
Leskovec, N. K., Jezeršek, M., Možina, J., Pavlovic, M. D., & Lunder, T. (2007) · Wound Repair and Regeneration · doi:10.1111/j.1524-475x.2007.00300.x · Cited by 43
Automated versus manual blood pressure measurement: A randomized crossover trial
Heinemann, M., Sellick, K., Rickard, C. M., Reynolds, P., & McGrail, M. R. (2008) · International Journal of Nursing Practice · doi:10.1111/j.1440-172x.2008.00696.x · Cited by 35
Gouy, S., Belghiti, J., Uzan, C., Canlorbe, G., Gauthier, T., & Morice, P. (2013) · International Journal of Gynecological Cancer · doi:10.1097/igc.0b013e3182a616a7 · Cited by 35
Brueren, M. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00125-8 · Cited by 35
Khadjesari, Z., Murray, E., Kalaitzaki, E., White, I. R., McCambridge, J., Godfrey, C., & Wallace, P. (2008) · Addictive Behaviors · doi:10.1016/j.addbeh.2008.11.010 · Cited by 35
Heesterbeek, P. J. C., Beumers, M. P. C., Jacobs, W. C. H., Havinga, M. E., & Wymenga, A. B. (2007) · The Knee · doi:10.1016/j.knee.2007.06.006 · Cited by 46
Cinthio, M., & Ahlgren, Å. R. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.02.016 · Cited by 35
Right ventricular myocardial performance index and exercise capacity in athletes
Kaşıkçıoğlu, E., Oflaz, H., Akhan, H., & Kayserilioğlu, A. (2005) · Heart and Vessels · doi:10.1007/s00380-005-0824-x · Cited by 37
Test–Retest Reliability of Quantitative Sudomotor Axon Reflex Testing
Berger, M. J., & Kimpinski, K. (2013) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e3182873254 · Cited by 35
Reeves, M. J., Mullard, A. J., & Wehner, S. (2008) · BMC Neurology · doi:10.1186/1471-2377-8-19 · Cited by 36
A nomogram for calculation of the Revised Baux Score
Williams, D. J., & Walker, J. D. (2014) · Burns · doi:10.1016/j.burns.2014.05.001 · Cited by 35
Working Group of Echocardiography, I. S. O. C., Galderisi, M., Nistri, S., Mondillo, S., Losi, M. A., Innelli, P., Mele, D., Muraru, D., D’Andrea, A., Ballo, P., et al. (2011) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-9-26 · Cited by 35
Henseler, H., Kuznetsova, A., Vogt, P. M., & Rosenhahn, B. (2014) · Journal of Plastic Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2013.12.025 · Cited by 35
Aide, N., Desmonts, C., Beauregard, J., Beyer, T., Kinross, K. M., Roselt, P. D., Neels, O. C., Agostini, D., Bardet, S., Bouvard, G., et al. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1352-1 · Cited by 35
Maximal oxygen uptake versus maximal power output in children
Dencker, M., Thorsson, O., Karlsson, M. K., Lindén, C., Wollmer, P., & Andersen, L. B. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802199789 · Cited by 35
Three‐dimensional power Doppler imaging of early‐stage cervical cancer
Hsu, K., Su, J.-M., Huang, S., Cheng, Y., Kang, C.-Y., Shen, M. ‐., Chang, F. ‐., & Chou, C. ‐. (2004) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.1756 · Cited by 35
Chen, B. Y., Gu, Z., Chen, H., Zhang, W., Fen, X., Cai, W., & Fan, Q. (2010) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e3181f01397 · Cited by 35
Pickles, K. J., Pirie, R. S., Rhind, S. M., Dixon, P. M., & McGorum, B. C. (2002) · Equine Veterinary Journal · doi:10.2746/042516402776186155 · Cited by 35
Shin, S. M., Shim, W., & Park, S. (2014) · Clinical and Experimental Hypertension · doi:10.3109/10641963.2013.863326 · Cited by 38
Béttex, D., Hinselmann, V., Hellermann, J. P., Jenni, R., & Schmid, E. R. (2004) · Anaesthesia · doi:10.1111/j.1365-2044.2004.03928.x · Cited by 35
Cardoso, C. R. L., Marques, C. E. C., Leite, N. C., & Salles, G. F. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e328352aba6 · Cited by 37
van den Bogaart, E., Schoone, G. J., ENGLAND, P. J., Faber, D., Orrling, K. M., Dujardin, J., Sundar, S., Schallig, H. D. F. H., & Adams, E. R. (2013) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.00751-13 · Cited by 35
Ishiguro, N., Kanehisa, H., Miyatani, M., Masuo, Y., & Fukunaga, T. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1259-2 · Cited by 37
The Value of Body Weight Measurement to Assess Dehydration in Children
Pruvost, I., Dubos, F., Chazard, E., Hue, V., Duhamel, A., & Martinot, A. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055063 · Cited by 35
Effects of crystalloid solutions on circulating lactate concentrations
Jackson, E. V., Wiese, J., Sigal, B., Miller, J., Bernstein, W. K., Kassel, D., Aduen, J. F., Bhatiani, A., Kerzner, R., Davidson, L., et al. (1997) · Critical Care Medicine · doi:10.1097/00003246-199711000-00022 · Cited by 35
Criterion-related validity and test–retest reliability of the 20m Square Shuttle Test
Metsios, G. S., Flouris, A. D., Koutedakis, Y., & Nevill, A. M. (2007) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2006.12.120 · Cited by 35
Use of the first rib for adult age estimation: a test of one method
Kurki, H. K. (2005) · International Journal of Osteoarchaeology · doi:10.1002/oa.788 · Cited by 44
Continuous Measurement of Endotracheal Tube Cuff Pressure
Sole, M. L., Aragon, D., Bennett, M., & Johnson, R. L. (2008) · AACN Advanced Critical Care · doi:10.1097/01.aacn.0000318126.79630.76 · Cited by 35
Tao, A., Chen, Z., Shao, Y., Wang, J., Zhao, Y., Lu, P., & Lü, F. (2013) · PLoS ONE · doi:10.1371/journal.pone.0080986 · Cited by 35
Longitudinal Association between Body Mass Index and Health-Related Quality of Life
Müller‐Nordhorn, J., Muckelbauer, R., Englert, H. S., Grittner, U., Berger, H., Sonntag, F., Völler, H., Prugger, C., Wegscheider, K., Katus, H. A., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0093071 · Cited by 41
Measurement of Goldmann Applanation Tonometer Calibration Error
Choudhari, N. S., George, R. J., Baskaran, M., Vijaya, L., & Dudeja, N. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2008.06.020 · Cited by 35
Pulse contour cardiac output analysis in a piglet model of severe hemorrhagic shock*
Piehl, M. D., Manning, J. E., McCurdy, S. L., Rhue, T. S., Kocis, K. C., Cairns, C. B., & Cairns, B. A. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31816592a3 · Cited by 36
Chaliki, H. P., Hurrell, D. G., Nishimura, R. A., Reinke, R. A., & Appleton, C. P. (2002) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.10203 · Cited by 35
Concordance correlation coefficient applied to discrete data
Carrasco, J. L., & Jover, L. (2005) · Statistics in Medicine · doi:10.1002/sim.2397 · Cited by 40
Comparing the Optical Properties of Soft Contact Lenses On and Off the Eye
Kollbaum, P. S., Bradley, A., & Thibos, L. N. (2013) · Optometry and Vision Science · doi:10.1097/01.opx.0000434275.93435.da · Cited by 35
Sharman, A., Zealley, I. A., Greenhalgh, R., Bassett, P., & Taylor, S. A. (2009) · European Radiology · doi:10.1007/s00330-009-1371-0 · Cited by 35
Estimation of the glomerular filtration rate in children: which algorithm should be used?
van Rossum, L. K., Mathôt, R. A. A., Cransberg, K., Zietse, R., & Vulto, A. G. (2005) · Pediatric Nephrology · doi:10.1007/s00467-005-2001-y · Cited by 35
Kudomi, N., Slimani, L., Järvisalo, M. J., Kišš, J., Läutamaki, R., Naum, G., Savunen, T., Knuuti, J. M., Iida, H., Nuutila, P., et al. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0796-z · Cited by 35
Comparison of 150-mm versus 100-mm visual analogue scales in free living adult subjects
Chaput, J., Gilbert, J., Gregersen, N. T., Pedersen, S. D., & Sjödin, A. M. (2010) · Appetite · doi:10.1016/j.appet.2010.01.016 · Cited by 40
Renkawitz, T. F., Schuster, T., Herold, T., Goessmann, H., Sendtner, E., Grifka, J. K., & Kalteis, T. (2009) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.250 · Cited by 35
Schütz, U. H. W., Ellermann, J., Schoss, D., Wiedelbach, H., Beer, M., & Billich, C. (2014) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2014.08.001 · Cited by 38
WONG, K. K. H., Jankelson, D., Reid, A., Unger, G., Dungan, G. C., Hedner, J. A., & Grunstein, R. R. (2008) · Behavior Research Methods · doi:10.3758/brm.40.1.360 · Cited by 39
Walsh, D. A., Yousef, A., McWilliams, D. F., Hill, R., Hargin, E., & Wilson, D. (2008) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2008.07.016 · Cited by 36
Reliability and variability of diffusion tensor imaging (DTI) tractography in pediatric epilepsy
Carlson, H. L., Durish, C. L., Brooks, B. L., Hodge, J. A., Kirton, A., Bello‐Espinosa, L. E., Hader, W. J., & Sherman, E. M. S. (2014) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2014.06.020 · Cited by 39
Testing agreement between a new method and the gold standard—How do we test?
McLaughlin, P. A. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.08.015 · Cited by 40
An Evaluation of Keratometry in 6-Year-Old Children
Huynh, S. C., Mai, T. Q., Kifley, A., Wang, J. J., Rose, K. A., & Mitchell, P. (2006) · Cornea · doi:10.1097/01.ico.0000214203.84081.ec · Cited by 35
Yoo, A. J., Hu, R., Hakimelahi, R., Lev, M. H., Nogueira, R. G., Hirsch, J. A., González, R. G., & Schaefer, P. W. (2011) · Journal of Neuroimaging · doi:10.1111/j.1552-6569.2011.00627.x · Cited by 35
A simple model for nondestructive leaf area estimation in bedding plants
Giuffrida, F., Rouphael, Y., Toscano, S., Scuderi, D., Romano, D., Rivera, C. M., Colla, G., & Leonardi, C. (2011) · Photosynthetica · doi:10.1007/s11099-011-0041-z · Cited by 35
Okujava, M. V., Schulz, R., Ebner, A., & Woermann, F. G. (2002) · Epilepsy Research · doi:10.1016/s0920-1211(01)00325-4 · Cited by 35
Left Ventricular Border Tracking Using Cardiac Motion Models and Optical Flow
Leung, K. Y. E., Danilouchkine, M. G., van Stralen, M., de Jong, N., van der Steen, A. F. W., & Bosch, J. G. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.01.010 · Cited by 41
Nelson, L. A., McCann, J., Loepke, A. W., Wu, J., Ben-Dor, B., & Kurth, C. D. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2393251 · Cited by 38
Disposition of plasma creatinine in non-azotaemic and moderately azotaemic cats
Garrérès, A. L., Laroute, V., Farge, F. D. L., Boudet, K. G., & Lefebvre, H. P. (2006) · Journal of Feline Medicine and Surgery · doi:10.1016/j.jfms.2006.08.003 · Cited by 35
Changes in Blood Velocity Following Microvascular Free Tissue Transfer
Hanasono, M. M., Ogunleye, O., Yang, J. S., Hartley, C. J., & Miller, M. J. (2009) · Journal of Reconstructive Microsurgery · doi:10.1055/s-0029-1223850 · Cited by 35
David, J., Levrat, A., Inaba, K., Macabéo, C., Rugeri, L., Fontaine, O., Gouél‐Cheron, A., & Piriou, V. (2012) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e31822c884d · Cited by 35
Plank, L. D., Monk, D. N., Woollard, G. A., & Hill, G. L. (1998) · Applied Radiation and Isotopes · doi:10.1016/s0969-8043(97)00060-2 · Cited by 36
Higgs, P., Costa, M., Freke, A., & Papasouliotis, K. (2014) · Journal of Small Animal Practice · doi:10.1111/jsap.12181 · Cited by 35
Koss, M. J., & Kohnen, T. (2009) · British Journal of Ophthalmology · doi:10.1136/bjo.2008.148726 · Cited by 35
Kawata, Y., Niki, N., Ohmatsu, H., Kusumoto, M., Tsuchida, T., Eguchi, K., Kaneko, M., & Moriyama, N. (2012) · Medical Physics · doi:10.1118/1.3679017 · Cited by 35
Ueki, J., Hughes, J. M. B., Peters, A. M., Bellingan, G. J., Mohammed, M. A., Dutton, J., Ussov, W. Y., Knight, D., & Glass, D. M. (1994) · Thorax · doi:10.1136/thx.49.4.327 · Cited by 35
Utz, W., Greiser, A., Niendorf, T., Dietz, R., & Schulz‐Menger, J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21611 · Cited by 35
Measuring wearing times of glasses and ocular patches using a thermosensor device from orthodontics
Januschowski, K., Bechtold, T. E., Schott, T. C., Huelber-Januschowski, M. S., Blumenstock, G., Bartz‐Schmidt, K. U., Besch, D., & Schramm, C. (2013) · Acta Ophthalmologica · doi:10.1111/aos.12171 · Cited by 35
de Bruin, E. D., Hubli, M., Hofer, P., Wolf, P., Murer, K., & Zijlstra, W. (2012) · Journal of Aging Research · doi:10.1155/2012/954378 · Cited by 41
Hernandez‐Andrade, E. A., Thuring, A., Jansson, T. T., Lingman, G., & Maršál, K. (2004) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.1003 · Cited by 35
Balakrishnan, P., Solomon, S., Mohanakrishnan, J., Cecelia, A. J., Kumarasamy, N., Murugavel, K. G., Venkatakrishnan, B., Solomon, S. S., Crowe, S. M., Ganesh, A. K., et al. (2006) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/01.qai.0000227791.92203.d5 · Cited by 35
The measurement of upper body alignment during the golf drive
Wheat, J. S., Vernon, T., & Milner, C. E. (2007) · Journal of Sports Sciences · doi:10.1080/02640410601113213 · Cited by 35
Simon, M., Gottschall, R., Gugel, M., Fritz, H., Mohr, S., & Klein, U. K. A. (2003) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2003.00170.x · Cited by 37
Reliability and validity of a new double poling ergometer for cross-country skiers
Holmberg, H., & Nilsson, J. E. (2007) · Journal of Sports Sciences · doi:10.1080/02640410701372685 · Cited by 35
Increased QT dispersion in patients with Prinzmetal's variant angina and cardiac arrest
Parchure, N. (2001) · Cardiovascular Research · doi:10.1016/s0008-6363(00)00290-x · Cited by 35
Hughes, K., Laidlaw, E. H., Reed, S. M., Keen, J., Abbott, J. B., Trevail, T., Hammond, G., Parkin, T. D. H., & Love, S. (2014) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.12431 · Cited by 35
Pryor, R. R., Seitz, J. R., Morley, J., Suyama, J., Guyette, F. X., Reis, S. E., & Hostler, D. (2012) · Prehospital Emergency Care · doi:10.3109/10903127.2011.614047 · Cited by 35
Acute Normobaric Hypoxia Stimulates Erythropoietin Release
Mackenzie, R., Watt, P., & Maxwell, N. (2008) · High Altitude Medicine & Biology · doi:10.1089/ham.2007.1043 · Cited by 44
Ventilatory threshold during incremental running can be estimated using EMG shorts
Tikkanen, O., Hu, M., Vilavuo, T., Tolvanen, P., Cheng, S., & Finni, T. J. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/4/603 · Cited by 44
Stege, G., van den Elshout, F. J. J., Heijdra, Y. F., van de Ven, M. J. T., Dekhuijzen, P. N. R., & Vos, P. J. E. (2008) · Respiration · doi:10.1159/000187631 · Cited by 39
Lösch, A., Scheuerle, A. F., Rupp, V., Auffarth, G. U., & Becker, M. D. (2004) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-004-0971-2 · Cited by 35
Grootendorst, D. C., de Jager, D. J., Brandenburg, V. M., Boeschoten, E. W., Krediet, R. T., Dekker, F. W., & The NECOSAD Study Group (2007) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfm381 · Cited by 35
Blot‐Souletie, N., HEBRARD, A., Acar, P., Carrié, D., & Puel, J. (2007) · Echocardiography · doi:10.1111/j.1540-8175.2007.00526.x · Cited by 35
Campi, K. L., Collins, C. E., Todd, W. D., Kaas, J. H., & Krubitzer, L. A. (2011) · Brain Behavior and Evolution · doi:10.1159/000324862 · Cited by 37
Oliveira, R. K. F., Ferreira, E. V. M., Ramos, R. P., Messina, C. M. S., Kapins, C. E. B., Silva, C. M. C., & Arakaki, J. S. O. (2013) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2013.10.008 · Cited by 39
Koul, P. A., Khan, U., Wani, A., Eachkoti, R., Jan, R. A., Shah, S., Masoodi, Z. A., Qadri, S., Ahmad, M., & Ahmad, A. (2010) · Annals of Thoracic Medicine · doi:10.4103/1817-1737.74274 · Cited by 40
Posada-Quintero, H. F., Delisle-Rodríguez, D., Cuadra, M. B., & Prieto, R. R. F. D. L. V. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/2/179 · Cited by 39
Controlled twitch mouth pressure reliably predicts twitch esophageal pressure
Kabitz, H., Walker, D., Walterspacher, S., & Windisch, W. (2006) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2006.10.007 · Cited by 35
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.