STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 13,801–13,900 of 47,868
Engblom, H., Hedström, E., Palmer, J. C., Wagner, G. S., & Arheden, H. (2004) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2004.00569.x · Cited by 39
Accuracy of Siri and Brozek equations in the percent body fat estimation in older adults
Guerra, R. S., do Amaral, T. F., Marques, E. A., Mota, J. A. P. S., & Restivo, M. T. (2010) · The journal of nutrition health & aging · doi:10.1007/s12603-010-0112-z · Cited by 39
A rapid HPLC-mass spectrometry cyclosporin method suitable for current monitoring practices
Salm, P., Taylor, P. J., Lynch, S. V., Warnholtz, C. R., & Pillans, P. I. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2005.04.009 · Cited by 36
Inflationary oscillometry provides accurate measurement of blood pressure in pre-eclampsia
Golara, M., Benedict, A., Jones, C., Randhawa, M., Poston, L., & Shennan, A. H. (2002) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2002.01487.x · Cited by 36
Wheat, J. S., Choppin, S. B., & Goyal, A. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.12.018 · Cited by 42
Widmer, L. W., Vikatmaa, P., Aho, P., Lepäntalo, M., & Venermo, M. A. (2012) · Annals of Vascular Surgery · doi:10.1016/j.avsg.2011.10.011 · Cited by 36
Sargent, M. A., & Gupta, S. (1993) · American Journal of Roentgenology · doi:10.2214/ajr.161.1.8390789 · Cited by 36
Intrasubject Repeatability of Internal Aberrometry Obtained With a New Integrated Aberrometer
Pinero, D. P., Juan, J. T., & ALIO, J. L. (2010) · Journal of Refractive Surgery · doi:10.3928/1081597x-20101214-01 · Cited by 36
Breath-Hold 1H-Magnetic Resonance Spectroscopy for Intrahepatic Lipid Quantification at 3 Tesla
Bredella, M. A., Ghomi, R. H., Thomas, B. J., Ouellette, H. A., Sahani, D. V., Miller, K. K., & Torriani, M. (2010) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0b013e3181cefb89 · Cited by 37
Capillary electrophoresis for therapeutic drug monitoring of antiepileptics
Kataoka, Y., Makino, K., & Oishi, R. (1998) · Electrophoresis · doi:10.1002/elps.1150191611 · Cited by 36
In vitro quantification of changes in human dentine tubule parameters using SEM and digital analysis
Ahmed, T., Mordan, N. J., Gilthorpe, M. S., & Gillam, D. G. (2005) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2005.01473.x · Cited by 36
Houlihan, C., Jenkins, M. A., Osicka, T. M., Scott, A., Parkin, D., & Jerums, G. (1999) · Australian and New Zealand Journal of Medicine · doi:10.1111/j.1445-5994.1999.tb01617.x · Cited by 39
Aerobic and Anaerobic Performances in Tethered Swimming
Papoti, M., da Silva, A. S. R., Araujo, G., Santiago, V. K. S., Martins, L. E. B., Cunha, S. A., & Gobatto, C. A. (2013) · International Journal of Sports Medicine · doi:10.1055/s-0031-1291250 · Cited by 36
Jiao, Z., Zhong, J., Zhang, M., Shi, X., Yu, Y., & Lu, W. (2006) · European Journal of Clinical Pharmacology · doi:10.1007/s00228-006-0215-y · Cited by 36
Resting Energy Expenditure in Anorexia Nervosa: Measured versus Estimated
Ghoch, M. E., Alberti, M., Capelli, C., Calugi, S., & Grave, R. D. (2011) · Journal of Nutrition and Metabolism · doi:10.1155/2012/652932 · Cited by 40
Gremmel, T., Calatzis, A., Steiner, S., Kaider, A., Seidinger, D., Koppensteiner, R., Kopp, C. W., & Panzer, S. (2010) · Platelets · doi:10.3109/09537104.2010.493587 · Cited by 36
Bendersky, M., Musolino, P. L., Rugilo, C., Schuster, G. R., & Sica, R. E. P. (2006) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2006.06.020 · Cited by 36
Variation in osteoarthritis biomarkers from activity not food consumption
Gordon, C. D., Stäbler, T., & Kraus, V. B. (2008) · Clinica Chimica Acta · doi:10.1016/j.cca.2008.07.031 · Cited by 36
The Use of the Motion Analysis System for Evaluation of Loss of Movement in the Finger
CHIU, H.-Y., LIN, S.-C., Su, F., WANG, S.-T., & HSU, H.-Y. (2000) · Journal of Hand Surgery (European Volume) · doi:10.1054/jhsb.1999.0344 · Cited by 36
Toomey, E. C., & Coote, S. B. (2013) · International Journal of MS Care · doi:10.7224/1537-2073.2011-036 · Cited by 40
IBZM tool: a fully automated expert system for the evaluation of IBZM SPECT studies
Buchert, R., Berding, G., Wilke, F., Martin, B., von Borczyskowski, D., Mester, J., Brenner, W., & Clausen, M. (2006) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0067-9 · Cited by 39
Direct Determination of Selenium and other Trace Elements in Serum Samples by ICP-MS
Forrer, R. S., Gautschi, K., Stroh, A., & Lutz, H. (1999) · Journal of Trace Elements in Medicine and Biology · doi:10.1016/s0946-672x(99)80065-0 · Cited by 36
Dynamic 18F-fluoride small animal PET to noninvasively assess renal function in rats
Schnöckel, U., Reuter, S., Stegger, L., Schlatter, E., Schäfers, K. P., Hermann, S., Schober, O., Gabriëls, G., & Schäfers, M. A. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0878-y · Cited by 36
Carnie, J., Boden, J. L., & Smith, F. G. (2002) · Anaesthesia · doi:10.1046/j.1365-2044.2002.02572_4.x · Cited by 36
Chui, W. S., & Cho, P. (2005) · Optometry and Vision Science · doi:10.1097/01.opx.0000162642.24885.71 · Cited by 36
Burdess, A., Michelsen, A. E., Brosstad, F. R., Fox, K. A. A., Newby, D. E., & Nimmo, A. F. (2011) · Thrombosis Research · doi:10.1016/j.thromres.2011.08.015 · Cited by 36
Non-Invasive (Transcutaneous) Monitoring of PCO2 (TcPCO2) in Older Adults
Janssens, J.-P., Laszlo, A., Uldry, C., Titelion, V., Picaud, C., & Michel, J. (2005) · Gerontology · doi:10.1159/000083990 · Cited by 36
Raine‐Fenning, N., Jayaprakasan, K., Deb, S., Clewes, J. S., Joergner, I., Bonaki, S. D., & Johnson, I. R. (2009) · Reproductive BioMedicine Online · doi:10.1016/s1472-6483(10)60010-7 · Cited by 36
Evaluation of Sample Bias for Measuring Plasma Iohexol Clearance in Kidney Transplantation
Stolz, A., Hoizey, G., Toupance, O., Lavaud, S., Vitry, F., Chanard, J., & Rieu, P. (2010) · Transplantation · doi:10.1097/tp.0b013e3181ca7d1b · Cited by 36
A comparison of two portable dynamometers in the assessment of shoulder and elbow strength
Vermeulen, H. M., de Bock, G. H., van Houwelingen, H. C., van der Meer, R. L., Mol, M. C., Plus, B. T., Rozing, P. M., & Vlieland, T. P. M. V. (2004) · Physiotherapy · doi:10.1016/j.physio.2004.08.005 · Cited by 46
Aggregate predictions improve accuracy when calculating metabolic variables used to guide treatment
Wells, J. C. K., Williams, J. E., Haroun, D., Fewtrell, M. S., Colantuoni, A., & Siervo, M. (2009) · American Journal of Clinical Nutrition · doi:10.3945/ajcn.2008.26629 · Cited by 38
Peukert, D., Laule, M., Taupitz, M., Kaufels, N., Hamm, B., & Dewey, M. (2007) · Academic Radiology · doi:10.1016/j.acra.2007.03.006 · Cited by 36
Evaluation of 3 Internal Standards for the Measurement of Cyclosporin by HPLC–Mass Spectrometry
Taylor, P. J., Brown, S. R., Cooper, D. P., Salm, P., Morris, M. R., Pillans, P. I., & Lynch, S. V. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.055160 · Cited by 36
Cephalometric soft tissue profile in unilateral cleft lip and palate patients
Bearn, D. (2002) · European Journal of Orthodontics · doi:10.1093/ejo/24.3.277 · Cited by 36
Desmarchelier, M. R., Rondenay, Y., Fitzgérald, G., & Lair, S. (2007) · Journal of Zoo and Wildlife Medicine · doi:10.1638/05-033.1 · Cited by 36
Sprengers, D., Molen, R. G. V. D., Kusters, J. G., Kwekkeboom, J., van der Laan, L. J. W., Niesters, H. G. M., Kuipers, E. J., de Man, R. A., Schalm, S. W., & Janssen, H. L. A. (2005) · Journal of Viral Hepatitis · doi:10.1111/j.1365-2893.2005.00626.x · Cited by 36
Measurement error for ultrasound fetal biometry performed by paramedics in rural Bangladesh
Neufeld, L. M., Wagatsuma, Y., Hussain, R., Begum, M. M., & Frongillo, E. A. (2009) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.6385 · Cited by 36
Shaw, A. D., Li, Z., Thomas, Z., & Stevens, C. W. (2002) · Critical Care · doi:10.1186/cc1457 · Cited by 36
Evaluation and performance characteristics of the automated coagulation analyzer ACL TOP
Appert‐Flory, A., Fischer, F., Jambou, D., & Toulon, P. A. (2007) · Thrombosis Research · doi:10.1016/j.thromres.2006.12.002 · Cited by 36
Takagi, A., Hibi, K., Zhang, X., Teo, T., Bonneau, H. N., Yock, P. G., & Fitzgerald, P. J. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00251-9 · Cited by 36
Hole, T., Otterstad, J. E., Sutton, M. S. J., Frøland, G., Holme, I., & Skjærpe, T. (2002) · European Journal of Echocardiography · doi:10.1016/s1525-2167(02)90167-8 · Cited by 36
Thelin, E. P., Nelson, D., Ghatan, P. H., & Bellander, B. (2014) · Frontiers in Neurology · doi:10.3389/fneur.2014.00159 · Cited by 39
Karunaratne, N. (2013) · Clinical and Experimental Ophthalmology · doi:10.1111/ceo.12124 · Cited by 36
Tidal Volume and Respiratory Timing Derived From a Portable Ventilation Monitor
McCool, F. D., Wang, J., & Ebi, K. L. (2002) · CHEST Journal · doi:10.1378/chest.122.2.684 · Cited by 36
Santamaría, G., Velasco, M., Farré, X., Vanrell, J. A., Cardesa, A., & Fernández, P. L. (2005) · Radiology · doi:10.1148/radiol.2342031252 · Cited by 36
Chua, S. O., Levine, R. A., Yosefy, C., Handschumacher, M. D., Chu, J. W., Qureshi, A. M., Neary, J., Ton-Nu, T.-T., Fu, M., Wu, C., et al. (2009) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep013 · Cited by 36
Laser, K. T., Bunge, M., Hauffe, P., Argueta, J. R. P., Kelter‐Klöpping, A., Barth, P., Sarikouch, S., Burchert, W., Kececioglu, D., & Körperich, H. (2009) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep185 · Cited by 36
McCann, S. J. (2002) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkf067 · Cited by 36
Capiod, J. C., Tournois, C., Vitry, F., Sevestre, M., Daliphard, S., Reix, T., Nguyên, P., Lefrère, J., & Pignon, B. (2008) · Vox Sanguinis · doi:10.1111/j.1423-0410.2008.01138.x · Cited by 39
Gondolesi, G. E., Yoshizumi, T., Bodian, C., Kim‐Schluger, L., Schiano, T. D., Fishbein, T., Schwartz, M., Miller, C. M., & Emre, S. (2004) · Transplantation Proceedings · doi:10.1016/j.transproceed.2004.04.094 · Cited by 36
Janssen, D. M. C., Sanders, A. P., Guldemond, N., Hermus, J. P. S., Walenkamp, G. H. I. M., & van Rhijn, L. W. (2014) · Journal of Foot and Ankle Research · doi:10.1186/1757-1146-7-33 · Cited by 36
The Gallon-Jug Shelf-Transfer Test: An Instrument to Evaluate Deteriorating Function in Older Adults
Signorile, J. F., Sandler, D., Ma, F., Bamel, S., Stanziano, D. C., Smith, W., Roos, B. A., & Sandals, L. (2007) · Journal of Aging and Physical Activity · doi:10.1123/japa.15.1.56 · Cited by 38
Comparison of methods of temperature measurement in swine
HANNEMAN, S. K. G., Jesurum-Urbaitis, J. T., & Bickel, D. R. (2004) · Laboratory Animals · doi:10.1258/002367704323133682 · Cited by 36
Shyur, S., Jan, R.-L., Webster, J. R., Chang, P., Lu, Y.-J., & Wang, J. (2009) · Pediatric Allergy and Immunology · doi:10.1111/j.1399-3038.2009.00956.x · Cited by 42
Quantification and variability in colonic volume with a novel magnetic resonance imaging method
Nilsson, M., Sandberg, T. H., Poulsen, J. L., Gram, M., Frøkjær, J. B., Østergaard, L. R., Krogh, K., Brock, C., & Drewes, A. M. (2015) · Neurogastroenterology & Motility · doi:10.1111/nmo.12673 · Cited by 40
Korcarz, C. E., Hirsch, A. T., Bruce, C. J., DeCara, J. M., Mohler, E. R., Pogue, B. W., Postley, J. E., Tzou, W. S., & Stein, J. H. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.08.038 · Cited by 41
Increased Oxidative Stress in Exudative Pleural Effusions
Papageorgiou, E., Κostikas, Κ., Kiropoulos, T. S., Karetsi, E., Mpatavanis, G., & Gourgoulianis, K. I. (2005) · CHEST Journal · doi:10.1378/chest.128.5.3291 · Cited by 37
Kolman, K. B., Mathieson, K. M., & Frias, C. (2007) · The Journal of the American Board of Family Medicine · doi:10.3122/jabfm.2007.03.060172 · Cited by 36
Acquisition Time and Reproducibility of Continuous Arterial Spin-Labeling Perfusion Imaging at 3T
Gevers, S., Majoie, C. B. L. M., van den Tweel, X. W., Lavini, C., & Nederveen, A. J. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1454 · Cited by 36
Assessment of accuracy and applicability of a new electronic peak flow meter and asthma monitor
Richter, K. R., Kanniess, F., Mark, B., Jörres, R., & MAGNUSSEN, H. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.12020457 · Cited by 36
Reliability of cervical lordosis measurement techniques on long-cassette radiographs
Janusz, P., Tyrakowski, M., Yu, H., & Siemionow, K. B. (2015) · European Spine Journal · doi:10.1007/s00586-015-4345-8 · Cited by 38
Registries for Evaluating Patient Outcomes
Gliklich, R. E., Dreyer, N. A., & Leavy, M. B. (2014) · Cited by 56
Shah, N., Dakin, S. C., Dobinson, S., Tufail, A., Egan, C. A., & Anderson, R. S. (2016) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2015-307375 · Cited by 40
Aggarwal, A. N., Gupta, D., Behera, D., & Jindal, S. K. (2005) · PubMed · Cited by 44
Bedside Lung Ultrasound During Acute Chest Syndrome in Sickle Cell Disease
Razazi, K., Deux, J., de Prost, N., Boissier, F., Cuquemelle, É., Galactéros, F., Rahmouni, A., Maître, B., Brun‐Buisson, C., & Dessap, A. M. (2016) · Medicine · doi:10.1097/md.0000000000002553 · Cited by 37
Lindholm, C., & Altimiras, J. (2016) · Comparative Biochemistry and Physiology Part A Molecular & Integrative Physiology · doi:10.1016/j.cbpa.2016.04.009 · Cited by 39
Medina‐Rosas, J., Yap, K. S.-Y., Anderson, M. A., Su, J., & Touma, Z. (2015) · Arthritis Care & Research · doi:10.1002/acr.22828 · Cited by 36
Waldecker, M., Dasanna, A. K., Lansche, C., Linke, M., Srismith, S., Cyrklaff, M., Sanchez, C. P., Schwarz, U. S., & Lanzer, M. (2016) · Cellular Microbiology · doi:10.1111/cmi.12650 · Cited by 45
Validation of Test Weighing Protocol to Estimate Enteral Feeding Volumes in Preterm Infants
Rankin, M. W., Jimenez, E. Y., Caraco, M., Collinson, M., Lostetter, L., & DuPont, T. L. (2016) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2016.08.011 · Cited by 36
The graphitization temperature threshold analyzed through a second-order structural transformation
Ouzilleau, P., Gheribi, A. E., & Chartrand, P. (2016) · Carbon · doi:10.1016/j.carbon.2016.08.041 · Cited by 36
Validation of a commercial inertial sensor system for spatiotemporal gait measurements in children
Lanovaz, J. L., Oates, A., Treen, T. T., Unger, J., & Musselman, K. E. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.09.021 · Cited by 43
Mehta, A., Cordero, J., Dobersch, S., Romero‐Olmedo, A. J., Savai, R., Bodner, J., Chao, C., Fink, L., Guzmán‐Díaz, E., Singh, I., et al. (2016) · EMBO Molecular Medicine · doi:10.15252/emmm.201606382 · Cited by 37
Chaparro, C. J., Taffé, P., Moullet, C., Depeyre, J. L., Longchamp, D., Perez, M., & Cotting, J. (2017) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2016.12.063 · Cited by 36
Dried Blood Spot sampling in psychiatry: Perspectives for improving therapeutic drug monitoring
Martial, L. C., Aarnoutse, R. E., Mulder, M., Schellekens, A., Brüggemann, R. J. M., Burger, D. M., Schene, A. H., & Batalla, A. (2017) · European Neuropsychopharmacology · doi:10.1016/j.euroneuro.2017.01.009 · Cited by 36
Poh, M., & Poh, Y. C. (2017) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2016.0230 · Cited by 43
Liu, M., Jiang, F., Jiang, H., Ye, S., & Chen, H. (2017) · Computers in Industry · doi:10.1016/j.compind.2017.05.005 · Cited by 36
Sailer, K. J., Pralle, R. S., Oliveira, R. C., Erb, S. J., Oetzel, G. R., & White, H. M. (2017) · Journal of Dairy Science · doi:10.3168/jds.2017-13583 · Cited by 36
Tobón, D. P., Jayaraman, S., & Falk, T. H. (2017) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2017.2767603 · Cited by 36
Sung, M. S., Heo, H., & Park, S. W. (2018) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2018.05.022 · Cited by 36
Naturally Occurring Shear Waves in Healthy Volunteers and Hypertrophic Cardiomyopathy Patients
Strachinaru, M., Bosch, J. G., Gils, L. V., van Dalen, B. M., Schinkel, A. F. L., van der Steen, A. F. W., de Jong, N., Michels, M., Vos, H. J., & Geleijnse, M. L. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.04.004 · Cited by 40
Xu, Z. Y., Jiang, H., Tao, A., Wu, S., Yan, W., Yuan, J., Liu, C., DeBuc, D. C., & Wang, J. (2015) · Microvascular Research · doi:10.1016/j.mvr.2015.05.003 · Cited by 36
Schmermund, A., Rensing, B. J. W. M., Sheedy, P. F., & Rumberger, J. A. (1998) · International journal of cardiac imaging · doi:10.1023/a:1006047613019 · Cited by 36
Wavelet filter for noise reduction and signal compression in an artificial nose
Zanchettin, C., & Ludermir, T. B. (2005) · Applied Soft Computing · doi:10.1016/j.asoc.2005.06.004 · Cited by 37
Reliable CFD-based estimation of flow rate in haemodynamics measures
Ponzini, R., Vergara, C., Redaelli, A. C. L., & Veneziani, A. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.05.022 · Cited by 40
Evaluation of oesophageal pulse oximetry in patients undergoing cardiothoracic surgery*
Kyriacou, P. A., Powell, S. L., Jones, D. P., & Langford, R. M. (2003) · Anaesthesia · doi:10.1046/j.1365-2044.2003.03091.x · Cited by 36
Westermann, J., Thiemann, F., Gerstner, L., Tatzber, F., Kozák, I., Bertsch, T., & Krüger, C. (2000) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2000.050 · Cited by 36
Detecting lung injury in patients with pulmonary edema
Schuster, D. P., Stark, T., Stephenson, J., & Royal, H. D. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1414-3 · Cited by 36
Detection of a relation between respiration and CSF pulsation with an echoplanar technique
Klose, U., Strik, C., Kiefer, C., & Grodd, W. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(200004)11:4<438::aid-jmri12>3.0.co;2-o · Cited by 89
Eide, P. K., Fremming, A. D., & Sorteberg, A. G. (2003) · Acta Neurologica Scandinavica · doi:10.1034/j.1600-0404.2003.00163.x · Cited by 36
Paniccia, R., Fedi, S., Carbonetto, F., Noferi, D., Conti, P., Bandinelli, B., Giusti, B., Evangelisti, L., Pretelli, P., Palmarini, M. F. G., et al. (2003) · Anesthesiology · doi:10.1097/00000542-200307000-00012 · Cited by 39
Boyd, H., Gunn, R. N., Marinho, N. V. S., Karwatowski, S. P., Bailey, D. L., Costa, D. C., & Camici, P. G. (1996) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf01249622 · Cited by 36
Poulsen, T. D., Klausen, T., Richalet, J., Kanstrup, I., Fogh-Andersen, N., & Olsen, N. (1998) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/s004210050360 · Cited by 43
Jensen, C., Vasseljen, O., & Westgaard, R. H. (1996) · Journal of Electromyography and Kinesiology · doi:10.1016/1050-6411(94)00012-3 · Cited by 36
The accuracy of the frequency–volume chart: comparison of self‐reported and measured volumes
Hansen, P., & Klarskov (1998) · British Journal of Urology · doi:10.1046/j.1464-410x.1998.00627.x · Cited by 36
Cavalcanti, S., Ciandrini, A., Severi, S., Badiali, F., Bini, S., Gattiani, A., Cagnoli, L., & Santoro, A. (2004) · Kidney International · doi:10.1111/j.1523-1755.2004.00523.x · Cited by 36
Alemán-Mateo, H., Franco, M. R. H., Esparza‐Romero, J., Estrada, R. O. M., Urquídez-Romero, R., & Valencia, M. E. (2007) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602597 · Cited by 42
A kinematic study of lateral unicompartmental arthroplasty
Robinson, B. J., Rees, J. L., Price, A. J., Beard, D. J., & Murray, D. M. (2002) · The Knee · doi:10.1016/s0968-0160(02)00039-x · Cited by 36
pnar, A. E.-T., Uiterkamp, L. A., Sikkema, J. M., Bots, M. L., Koomans, H. A., Bruinse, H. W., & Franx, A. (2003) · Journal of Hypertension · doi:10.1097/00004872-200311000-00014 · Cited by 36
Martin, G., Tapsell, L. C., Batterham, M. J., & Russell, K. G. (2002) · Public Health Nutrition · doi:10.1079/phn2002329 · Cited by 39
A comparison of serum and saliva paracetamol concentrations.
Smith, M., Whitehead, E., O'Sullivan, G., & Reynolds, F. (1991) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1991.tb05580.x · Cited by 35
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.