STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 14,001–14,100 of 47,868
O'Connor, R. D., Xu, J., Ewald, G. A., Ackerman, J. J. H., Peterson, L. R., Gropler, R. J., & Bashir, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22734 · Cited by 38
Stoustrup, P. B., Verna, C., Kristensen, K. D., Küseler, A., Herlin, T., & Pedersen, T. K. (2012) · Orthodontics and Craniofacial Research · doi:10.1111/ocr.12008 · Cited by 36
Hidalgo, I. R., Rozema, J. J., Dhubhghaill, S. N., Zakaria, N., Koppen, C., & Tassignon, M. (2015) · Journal of Refractive Surgery · doi:10.3928/1081597x-20150224-01 · Cited by 35
Morris, M., Lamb, K., Hayton, J. W., Cotterrell, D., & Buckley, J. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1439-1 · Cited by 35
MacMillan, E. L., Mädler, B., Fichtner, N., Dvorak, M. F., Li, D. K. B., Curt, A. E. P., & MacKay, A. L. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.08.076 · Cited by 38
Automatic fovea location in retinal images using anatomical priors and vessel density
Chin, K. S., Trucco, E., Tan, L., & Wilson, P. J. (2013) · Pattern Recognition Letters · doi:10.1016/j.patrec.2013.03.016 · Cited by 35
Léderlin, M., Ozier, A., Montaudon, M., Bégueret, H., Ousova, O., Marthan, R., Berger, P., & Laurent, F. (2009) · European Radiology · doi:10.1007/s00330-009-1541-0 · Cited by 35
Cesano, A., Perbellini, O., Evensen, E., Chu, C. C., Cioffi, F., Ptacek, J., Damle, R. N., Chignola, R., Cordeiro, J., Yan, X., et al. (2012) · Haematologica · doi:10.3324/haematol.2012.071910 · Cited by 39
Vlasselaers, D., Herpe, T. V., Milants, I., Eerdekens, M., Wouters, P. J., Moor, B. D., & den Berghe, G. V. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200603 · Cited by 39
Miller, C., Pearce, K., Jordan, P., Argyle, R., Clark, D., Stout, M., Ray, S. G., & Schmitt, M. (2011) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ejechocard/jer248 · Cited by 42
Queiróga, M. R., Cavazzotto, T. G., Katayama, K. Y., Portela, B. S., Tartaruga, M. P., & Ferreira, S. A. (2013) · Motriz Revista de Educação Física · doi:10.1590/s1980-65742013000400005 · Cited by 47
Tissue Microarray Validation: A Methodologic Study with Special Reference to Lung Cancer
Karlsson, C., Bodin, L., Piehl‐Aulin, K., & Karlsson, M. G. (2009) · Cancer Epidemiology Biomarkers & Prevention · doi:10.1158/1055-9965.epi-08-0743 · Cited by 39
Heart rate during sleep: implications for monitoring training status.
Waldeck, M. R., & Lambert, M. (2003) · Europe PMC (PubMed Central) · Cited by 35
Duc, S., Villerius, V., Bertucci, W., & Grappe, F. (2007) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2.3.270 · Cited by 51
Higher body mass index is associated with higher fractional creatinine excretion in healthy subjects
Sinkeler, S. J., Visser, F. W., Krikken, J. A., Stegeman, C. A., van der Heide, J. J. H., & Navis, G. (2011) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfq850 · Cited by 39
Tarroni, G., Corsi, C., Antkowiak, P. F., Veronesi, F., Kramer, C. M., Epstein, F. H., Walter, J. J., Lamberti, C., Lang, R. M., Mor‐Avi, V., et al. (2012) · Radiology · doi:10.1148/radiol.12112475 · Cited by 35
Normal Values for the Size of a Halo Produced by a Glare Source
Puell, M. C., Pérez‐Carrasco, M. J., Barrio, A. R., Antona, B., & Palomo‐Álvarez, C. (2013) · Journal of Refractive Surgery · doi:10.3928/1081597x-20130819-03 · Cited by 35
Zamora, E., Lupón, J., de Antonio, M., Vila, J., Peñafiel, J., Galán, A., Urrútia, A., Domingo, M., & Bayés‐Genís, A. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2013.212951 · Cited by 35
Agreement between Two Different Scoring Procedures for Goal Attainment Scaling is Low
Bovend’Eerdt, T. J. H., Dawes, H., Izadi, H., & Wade, D. T. (2011) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0624 · Cited by 42
Reliability analysis for continuous measurements: Equivalence test for agreement
Yi, Q., Wang, P., & He, Y. (2007) · Statistics in Medicine · doi:10.1002/sim.3110 · Cited by 41
Körperich, H., Barth, P., Gieseke, J., Muller, K., Burchert, W., Esdorn, H., Kececioglu, D., Beerbaum, P., & Laser, K. T. (2014) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeu179 · Cited by 35
Comparison of corneal endothelial cell measurements by two non-contact specular microscopes
Gasser, L., Reinhard, T., & Böhringer, D. (2015) · BMC Ophthalmology · doi:10.1186/s12886-015-0068-1 · Cited by 35
Repeatability of Autofluorescence Lifetime Imaging at the Human Fundus in Healthy Volunteers
Klemm, M., Dietzel, A., Haueisen, J., Nagel, E., Hammer, M., & Schweitzer, D. (2013) · Current Eye Research · doi:10.3109/02713683.2013.779723 · Cited by 35
Cooney, J., Moore, J. P., Ahmad, Y. A., Jones, J. G., LEMMEY, A. B., Casanova, F., Maddison, P. J., & Thom, J. M. (2013) · International Journal of Rheumatology · doi:10.1155/2013/174541 · Cited by 37
Is Home Blood Pressure Monitoring Useful in the Management of Patients With Resistant Hypertension?
Muxfeldt, E. S., Barros, G. S., Viegas, B. B., Carlos, F., & Salles, G. F. (2014) · American Journal of Hypertension · doi:10.1093/ajh/hpu145 · Cited by 44
Hislop, J. F., Bulley, C., Mercer, T. H., & Reilly, J. J. (2012) · Pediatric Exercise Science · doi:10.1123/pes.24.4.563 · Cited by 42
The effect of quantity of ice and size of contact area on ice pack/skin interface temperature
Janwantanakul, P. (2009) · Physiotherapy · doi:10.1016/j.physio.2009.01.004 · Cited by 35
Karakochuk, C. D., Janmohamed, A., Whitfield, K. C., Barr, S. I., Vercauteren, S., Kroeun, H., Talukder, A., McLean, J., & Green, T. (2014) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.12.021 · Cited by 36
Bergamini, E., Pillet, H., Hausselle, J., Thoreux, P., Guérard, S., Camomilla, V., CAPPOZZO, A., & Skalli, W. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2011.03.006 · Cited by 44
Dandekar, V. K., Bauml, M. A., Ertel, A. W., Dickens, C., Gonzalez, R. C., & Farzaneh‐Far, A. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-16-24 · Cited by 35
Gómez‐Polo, C., Muñoz, M. P., Luengo, M. C. L., Vicente, P., Galindo‐Villardón, P., & Casado, A. M. M. (2015) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2015.07.013 · Cited by 42
Tobon‐Gomez, C., Butakoff, C., Aguadé‐Bruix, S., Sukno, F. M., Moragas, G., & Frangi, A. F. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2004819 · Cited by 36
Singler, K., Bertsch, T., Heppner, H. J., Kob, R., Hammer, K., Biber, R., Sieber, C. C., & Christ, M. (2013) · Age and Ageing · doi:10.1093/ageing/aft121 · Cited by 35
Macpherson, T. W., Taylor, J. M., McBain, T., Weston, M., & Spears, I. R. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.12.008 · Cited by 38
Cross Validation of the 20-Meter Shuttle Run Test for Adolescents with Down Syndrome
Guerra-Balic, M., Pitetti, K. H., & Fernhall, B. (2003) · Adapted Physical Activity Quarterly · doi:10.1123/apaq.20.1.70 · Cited by 35
Ohno, Y., Koyama, H., Fujisawa, Y., Yoshikawa, T., Seki, S., Sugihara, N., & Sugimura, K. (2015) · European Journal of Radiology · doi:10.1016/j.ejrad.2015.11.009 · Cited by 37
Kolsrud, O., Ricksten, S., Holmberg, E. C., Felldin, M., Karason, K., Hammarsten, O., Samuelsson, O. G., & Dellgren, G. (2015) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfv338 · Cited by 35
Ventura, B. V., Al-Mohtaseb, Z. N., Wang, L., Koch, D. D., & Weikert, M. P. (2015) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2015.11.003 · Cited by 35
A new design of CAD/CAM surgical template system for two-piece narrowing genioplasty
Li, B., Shen, S. G., Yu, H., Li, J., Xia, J. J., & Wang, X. (2015) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2015.10.013 · Cited by 35
Bahat, H. S., Sprecher, E., Sela, I., & Treleaven, J. M. (2016) · European Spine Journal · doi:10.1007/s00586-016-4388-5 · Cited by 40
Vetter, T. R., Bridgewater, C. L., Ascherman, L. I., Madan‐Swain, A., & McGwin, G. (2014) · Pain Research and Management · doi:10.1155/2014/736053 · Cited by 36
Bershad, E. M., Anand, A., DeSantis, S. M., Yang, M., Tang, R. A., Calvillo, E., Malkin-Gosdin, L., Foroozan, R., Damani, R. H., Maldonado, N. J., et al. (2015) · World Neurosurgery · doi:10.1016/j.wneu.2015.11.102 · Cited by 36
Methods for estimating multivariate stand yields and errors using k-NN and aerial laser scanning
Dash, J. P., Marshall, H. M., & Rawley, B. (2015) · Forestry An International Journal of Forest Research · doi:10.1093/forestry/cpu054 · Cited by 39
Leoni, D., Falla, D., Heitz, C., Capra, G., Clijsen, R., Egloff, M., Cescon, C., Baeyens, J., & Barbero, M. (2016) · Pain Practice · doi:10.1111/papr.12429 · Cited by 42
Repeatability of Placido‐Based Corneal Topography in Keratoconus
Ortiz-Toquero, S., Rodríguez, G., de Juan, V., & Martín, R. (2014) · Optometry and Vision Science · doi:10.1097/opx.0000000000000421 · Cited by 35
Inter-observer Variability Analysis of Automatic Lung Delineation in Normal and Disease Patients
Saba, L., Than, J. C. M., Noor, N. M., Rijal, O. M., Kassim, R. M., Yunus, A., Ng, C. R., & Suri, J. S. (2016) · Journal of Medical Systems · doi:10.1007/s10916-016-0504-7 · Cited by 35
Estimation of firm performance from a MIMIC model
Chaudhuri, K., Kumbhakar, S. C., & Sundaram, L. (2016) · European Journal of Operational Research · doi:10.1016/j.ejor.2016.05.005 · Cited by 40
Kjær, B. H., Ellegaard, K., Wieland, I., Warming, S., & Juul‐Kristensen, B. (2017) · Physiotherapy Theory and Practice · doi:10.1080/09593985.2017.1318419 · Cited by 47
Handeland, K., Kjellevold, M., Markhus, M. W., Graff, I. E., Frøyland, L., Lie, Ø. H., Skotheim, S., Stormark, K. M., Dahl, L., & Øyen, J. (2016) · Nutrients · doi:10.3390/nu8080467 · Cited by 41
Reliability of isometric trunk moment measurements in healthy persons over 50 years of age
Kienbacher, T., Paul, B., Habenicht, R., Starek, C., Wolf, M., Kollmitzer, J., & EBENBICHLER, G. R. (2014) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-1266 · Cited by 41
Bronchoarterial ratio in never‐smokers adults: Implications for bronchial dilation definition
Díaz, A. A., Young, T. P., Maselli, D. J., Martinez, C. H., MacLean, E. S., Yen, A., Dass, C. A., Simpson, S. A., Lynch, D. A., Kinney, G. L., et al. (2016) · Respirology · doi:10.1111/resp.12875 · Cited by 38
Grosso, P., Snider, M. G., & Muir, J. M. (2016) · The Open Orthopaedics Journal · doi:10.2174/1874325001610010490 · Cited by 35
Cahill‐Rowley, K., & Rose, J. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.10.031 · Cited by 35
SPARCS and Pelli–Robson contrast sensitivity testing in normal controls and patients with cataract
Gupta, L. C., Cvintal, V., Delvadia, R., Sun, Y., Erdem, E., Zangalli, C. E. S., Lu, L., Wizov, S. S., Richman, J., Spaeth, E., et al. (2017) · Eye · doi:10.1038/eye.2016.319 · Cited by 35
Quantifying Aortic Valve Calcification using Coronary Computed Tomography Angiography
Alqahtani, A. M., Boczar, K. E., Kansal, V., Chan, K. L., Dwivedi, G., & Chow, B. J. W. (2017) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2017.01.007 · Cited by 35
Jegatheswaran, J., Ruzicka, M., Hiremath, S. S., & Edwards, C. (2017) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2017.01.020 · Cited by 38
Prediction of the true IOL position
Norrby, S., Bergman, R., Hirnschall, N. D., Nishi, Y., & Findl, O. (2017) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2016-309543 · Cited by 37
New Precision Metrics for Contrast Sensitivity Testing
Dörr, M., Elze, T., Wang, H., Lu, Z., Bex, P. J., & Lesmes, L. A. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2708745 · Cited by 35
Raucci, F. J., Parra, D. A., Christensen, J. T., Hernandez, L. E., Markham, L. W., Xu, M., Slaughter, J. C., & Soslow, J. H. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-017-0377-z · Cited by 35
Wilson, J. D., Khan-Perez, J., Marley, D., Buttress, S. J., Walton, M., Li, B., & Roy, B. (2017) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2017.06.004 · Cited by 35
Measurement of Fluid Status Using Bioimpedance Methods in Korean Pediatric Patients on Hemodialysis
Yang, E. M., Park, E., Ahn, Y. H., Choi, H. J., Kang, H. G., Cheong, H. I., & Ha, I. S. (2017) · Journal of Korean Medical Science · doi:10.3346/jkms.2017.32.11.1828 · Cited by 35
Dutch population specific sex estimation formulae using the proximal femur
Colman, K. L., Janssen, M. C. L., Stull, K. E., van Rijn, R. R., Oostra, R., de Boer, H. H., & van der Merwe, A. E. (2017) · Forensic Science International · doi:10.1016/j.forsciint.2017.12.029 · Cited by 35
Lévy, S., Guertin, M., Khatibi, A., Mezer, A., Martinu, K., Chen, J.-I., Stikov, N., Rainville, P., & Cohen‐Adad, J. (2018) · PLoS ONE · doi:10.1371/journal.pone.0189944 · Cited by 38
Steinmetz, M., Broder, M., Hösch, O., Lamata, P., Kutty, S., Kowallick, J. T., Staab, W., Ritter, C. O., Hasenfuss, G. P., Paul, T., et al. (2018) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.11.097 · Cited by 37
Brouwer, T. A., van den Boogaard, C., van Roon, E. N., Kalkman, C. J., & Veeger, N. J. G. M. (2018) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-018-0123-6 · Cited by 35
Winzer, E., Wakolbinger, M., & Schindler, K. (2018) · European Journal of Clinical Nutrition · doi:10.1038/s41430-018-0126-x · Cited by 41
Uz, Z., van Gulik, T. M., Aydemirli, M. D., Guerci, P., Ince, Y., Cuppen, D., Ergin, B., Aksu, U., de Mol, B. A. J. M., & İnce, C. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00962.2017 · Cited by 35
Presset, B., Laurenczy, B., Malatesta, D., & Barral, J. (2018) · Journal of Exercise Science & Fitness · doi:10.1016/j.jesf.2018.05.001 · Cited by 39
Objective Assessment of Spasticity With a Method Based on a Human Upper Limb Model
Ang, W. S., Geyer, H., Chen, I., & Ang, W. T. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2821197 · Cited by 35
Buchan, D. S., McSeveney, F., & McLellan, G. (2018) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12538 · Cited by 42
Wong, B., Parikh, D., Rosen, L. M., Gorski, M. G., Angelilli, A., & Shih, C. (2018) · Journal of Glaucoma · doi:10.1097/ijg.0000000000001059 · Cited by 35
Comparison of Green Versus Blue Fundus Autofluorescence inABCA4-Related Retinopathy
Müller, P. L., Pfau, M., Mauschitz, M. M., Möller, P. T., Birtel, J., Chang, P., Gliem, M., Schmitz-Valckenberg, S., Fleckenstein, M., Holz, F. G., et al. (2018) · Translational Vision Science & Technology · doi:10.1167/tvst.7.5.13 · Cited by 36
Banerjee, M. B., Pradhan, S., Roy, R. B., Tudu, B., Das, D. K., Bandyopadhyay, R., & Pramanik, P. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2878926 · Cited by 35
Similä, T., Nieminen, P. A., & Virtanen, J. I. (2018) · BMC Oral Health · doi:10.1186/s12903-018-0666-4 · Cited by 35
Validation of a Wearable Device and an Algorithm for Respiratory Monitoring During Exercise
Massaroni, C., Nicolò, A., Girardi, M., Camera, A. L., Schena, E., Sacchetti, M., Silvestri, S., & Taffoni, F. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2899658 · Cited by 39
Colorado, L. H., Markoulli, M. P., & Edwards, K. P. (2019) · Current Eye Research · doi:10.1080/02713683.2019.1600196 · Cited by 37
The use of wearable cameras in assessing children's dietary intake and behaviours in China
Zhou, Q., Wang, D., Mhurchú, C. N., Gurrin, C. G., Zhou, J., Cheng, Y., & Wang, H. (2019) · Appetite · doi:10.1016/j.appet.2019.03.032 · Cited by 43
Malla, C. U. P., Hernández, M. V., Rachmadi, M. F., & Komura, T. (2019) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2019.00033 · Cited by 38
Jakobsen, G., Engstrøm, M., Thronæs, M., Løhre, E. T., Kaasa, S., Fayers, P. M., Hjermstad, M. J., & Klepstad, P. (2019) · Supportive Care in Cancer · doi:10.1007/s00520-019-04998-5 · Cited by 43
Porter, J. A., Nguo, K., Collins, J., Kellow, N. J., Huggins, C. E., Gibson, S., Davidson, Z. E., Schoeller, D. A., Prentice, R. L., Neuhouser, M. L., et al. (2019) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/nqz200 · Cited by 36
Yan, W., Xu, X., Xu, Q., Yan, W., Sun, Z., Jiang, Q. Y., & Shi, D. (2019) · Annals of Translational Medicine · doi:10.21037/atm.2019.08.49 · Cited by 35
Sex-specific distributions and determinants of thoracic aortic diameters in the elderly
Bons, L. R., Rueda-Ochoa, O. L., Ghoul, K. E., Rohde, S., Budde, R. P. J., Leening, M. J. G., Vernooij, M. W., Franco, O. H., van der Lugt, A., Roos‐Hesselink, J. W., et al. (2019) · Heart · doi:10.1136/heartjnl-2019-315320 · Cited by 41
Jandeaux, C., Kuchcinski, G., Ternynck, C., Riquet, A., Leclerc, X., Pruvo, J., & Soto-Ares, G. (2019) · American Journal of Neuroradiology · doi:10.3174/ajnr.a6257 · Cited by 35
Sieren, M. M., Berlin, C., Oechtering, T. H., Hunold, P., Drömann, D., Barkhausen, J., & Frydrychowicz, A. P. (2019) · PLoS ONE · doi:10.1371/journal.pone.0224121 · Cited by 35
Estimation of ocular axial length from conventional optometric measures
Morgan, P. B., McCullough, S. J., & Saunders, K. J. (2019) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2019.11.005 · Cited by 35
Kowalkowska, J., Wądołowska, L., Hamułka, J., Wojtas, N., Człapka-Matyasik, M., Kozirok, W., Bronkowska, M., Sadowska, J., Naliwajko, S. K., Dziaduch, I., et al. (2019) · Nutrients · doi:10.3390/nu11122929 · Cited by 40
Rensen, N., Steur, L. M. H., Schepers, S. A., Merks, J. H. M., Moll, A. C., Kaspers, G. J. L., van Litsenburg, R. R. L., & Grootenhuis, M. A. (2019) · Quality of Life Research · doi:10.1007/s11136-019-02365-9 · Cited by 35
Cassinotto, C., Lapuyade, B., Guiu, B., Grottes, H. M. D., Piron, L., Merrouche, W., Irlès‐Depé, M., Molinari, N., & de Lédinghen, V. (2020) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2020.04.034 · Cited by 39
Cheung, G. C., Dalci, O., Mustac, S., Papageorgiou, S. N., Hammond, S., Darendeliler, M. A., & Papadopoulou, A. K. (2020) · European Journal of Orthodontics · doi:10.1093/ejo/cjaa031 · Cited by 38
Jarrett, C. L., Shields, K. L., Broxterman, R. M., Hydren, J. R., Park, S. H., Gifford, J. R., & Richardson, R. S. (2020) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00025.2020 · Cited by 35
Zhou, Y., Wetherley, E. B., & Gader, P. (2020) · Remote Sensing of Environment · doi:10.1016/j.rse.2020.111857 · Cited by 39
On Statistical Measures for Data Quality Evaluation
Han, X. (2020) · Journal of Geographic Information System · doi:10.4236/jgis.2020.123011 · Cited by 35
Almazán-Polo, J., López‐López, D., Morales, C. R., Rodríguez‐Sanz, D., Vallejo, R., Losa‐Iglesias, M. E., Bravo-Aguilar, M., & Calvo‐Lobo, C. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9082647 · Cited by 40
Warmerdam, E., Romijnders, R., Welzel, J., Hansen, C., Schmidt, G. U., & Maetzler, W. (2020) · Sensors · doi:10.3390/s20205963 · Cited by 40
Philip, K. E. J., Bennett, B., Fuller, S., Lonergan, B., McFadyen, C., Burns, J., Tidswell, R., & Vlachou, A. (2020) · BMJ Open Respiratory Research · doi:10.1136/bmjresp-2020-000778 · Cited by 36
Zabaloy, S., Freitas, T. T., Carlos‐Vivas, J., Giráldez, J. C., Loturco, I., Pareja‐Blanco, F., González, J. G., & Alcaráz, P. E. (2021) · Sports Biomechanics · doi:10.1080/14763141.2020.1838603 · Cited by 42
Iannaccone, A., Conte, D., Cortis, C., & Fusco, A. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18020392 · Cited by 46
Halochromic Polymer Nanosensors for Simple Visual Detection of Local pH in Coatings
Theerasilp, M., & Crespy, D. (2021) · Nano Letters · doi:10.1021/acs.nanolett.1c00620 · Cited by 35
Pearce, E., Horvath, S., Katta, S., Dagnall, C. L., Aubert, G., Hicks, B. D., Spellman, S. R., Katki, H. A., Savage, S. A., Alsaggaf, R., et al. (2021) · Aging · doi:10.18632/aging.203126 · Cited by 41
Mejía‐Mejía, E., May, J. M., Elgendi, M., & Kyriacou, P. A. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106222 · Cited by 41
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.