STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 14,901–15,000 of 47,868
Sensitive non-isotopic assays for autoantibodies to IA-2 and to a combination of both IA-2 and GAD65
Chen, S., Willis, J. A., Maclean, C., Ananieva-Jordanova, R., Amoroso, M., Brooking, H., Powell, M. J., Collins, A., Bennett, S., Mitchell, S. E., et al. (2005) · Clinica Chimica Acta · doi:10.1016/j.cccn.2005.02.006 · Cited by 37
Serum free light chains; the need to establish local reference intervals
Pattenden, R. J., Rogers, S. Y., & Wenham, P. R. (2007) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/000456307782268200 · Cited by 33
Wuang, Y.-P., Chang, J., Wang, M.-H., & Lin, H. (2013) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2013.04.010 · Cited by 35
Shimizu, H., Ohnishi, Y., Inoue, T., & Yokoyama, M. (2001) · Journal of Electrocardiology · doi:10.1054/jelc.2001.23361 · Cited by 33
Hedeer, F., Palmer, J. C., Arheden, H., & Ugander, M. (2010) · BMC Medical Imaging · doi:10.1186/1471-2342-10-10 · Cited by 33
Walking speed in elderly outpatients depends on the assessment method
Pasma, J. H., Stijntjes, M., Ou, S. S., Blauw, G. J., Meskers, C. G. M., & Maier, A. B. (2014) · AGE · doi:10.1007/s11357-014-9736-y · Cited by 42
Practicality, Usefulness, and Limits of Pulse Oximetry in Critical Small Animal Patients
Hendricks, J. C., & King, L. G. (1993) · Journal of Veterinary Emergency and Critical Care · doi:10.1111/j.1476-4431.1993.tb00098.x · Cited by 33
EFFECT OF ACUTE AIRWAY INFLAMMATION ON THE PULMONARY ANTIOXIDANT STATUS
Deaton, C. M., Marlin, D., Smith, N. C., Harris, P. A., Dagleish, M. P., Schroter, R. C., & Kelly, F. J. (2005) · Experimental Lung Research · doi:10.1080/01902140591007092 · Cited by 33
Clinical Relevance of Diagnosing COPD by Fixed Ratio or Lower Limit of Normal: A Systematic Review
van Dijk, W. D., Gupta, N., Tan, W. C., & Bourbeau, J. (2013) · COPD Journal of Chronic Obstructive Pulmonary Disease · doi:10.3109/15412555.2013.781996 · Cited by 38
Hinterwimmer, S., Graichen, H., Vogl, T. J., & Abolmaali, N. (2008) · European Radiology · doi:10.1007/s00330-008-0896-y · Cited by 38
Effect of experience of severe stroke on subjective valuations of quality of life after stroke
Murphy, R. (2001) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.70.5.679 · Cited by 33
Ibrahim, E. H., Shaffer, J. M., & White, R. D. (2011) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2011.04.012 · Cited by 33
Stimulated skin wrinkling for predicting intraepidermal nerve fibre density
Wilder-Smith, E. P., Guo, Y., & Chow, A. W. L. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.03.011 · Cited by 33
Pickenbrock, H., Diel, A., & Zapf, A. (2015) · Clinical Rehabilitation · doi:10.1177/0269215515578297 · Cited by 33
Concha, M. R., Mertz, V. F., Cortínez, L. I., González, K. A., & Butte, J. M. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181a491b8 · Cited by 33
Dahaba, A. A., Xue, J. X., Zhao, G., Liu, Q. H., Xu, G. X., Bornemann‐Cimenti, H., Rehak, P., & Metzler, H. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181cf4111 · Cited by 37
Diffuse Optical Tomography of the Breast: Initial Validation in Benign Cysts
van de Ven, S. M. W. Y., Elias, S. G., Wiethoff, A. J., van der Voort, M., Leproux, A., Tolker‐Nielsen, T., Brendel, B., Bakker, L., van der Mark, M. B., Mali, W. P. T. M., et al. (2008) · Molecular Imaging and Biology · doi:10.1007/s11307-008-0176-x · Cited by 44
Assessment of body composition in adolescent subjects with anorexia nervosa by bioimpedance
Moreno, M. V., Djeddi, D., & Jaffrin, M. Y. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.09.005 · Cited by 39
Validation of a new method for determination of cup orientation in THA
Steppacher, S. D., Tannast, M., Guoyan Zheng, A., Zhang, X., Kowal, J., Anderson, S. E., Siebenrock, K. A., & Murphy, S. B. (2009) · Journal of Orthopaedic Research® · doi:10.1002/jor.20929 · Cited by 33
Bahrmann, P., Figulla, H. R., Wagner, M., Ferrari, M. W., Voss, A., & Werner, G. S. (2005) · Heart · doi:10.1136/hrt.2004.048629 · Cited by 33
Madore, D. V., Meade, B. D., Rubin, F. A., Deal, C. D., & Lynn, F. (2010) · Vaccine · doi:10.1016/j.vaccine.2010.04.094 · Cited by 36
Deurloo, K., Spreeuwenberg, M., Rekoert‐Hollander, M., & van Vugt, J. (2007) · Journal of Clinical Ultrasound · doi:10.1002/jcu.20306 · Cited by 33
The reproducibility of dipping status: beyond the cutoff points
Chaves, H., de Souza, F. M. C., & Krieger, E. M. (2005) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000172709.05158.59 · Cited by 33
Kimura, M., Nishimura, A., Yokogawa, H., Okuda, T., Higashide, T., Saito, Y., & Sugiyama, K. (2012) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2012.05.010 · Cited by 33
Protocolo breve de evaluación del suicidio: fiabilidad interexaminadores
Nieto, R. G., Parra, I., Palao, D. J., López‐Castromán, J., Sáiz, P. A., García‐Portilla, M. P., Ruiz, J. S., Ibáñez, Á., Tiana, T., Duran‐Sindreu, S., et al. (2011) · Revista de Psiquiatría y Salud Mental · doi:10.1016/j.rpsm.2011.10.001 · Cited by 33
Clinical agreement between automated and calculated ultrasound measurements of bladder volume
Dudley, N. J., Kirkland, M., Lovett, J., & Watson, A. (2003) · British Journal of Radiology · doi:10.1259/bjr/31249864 · Cited by 33
Fuller, C. D., Thomas, C. R., Schwartz, S., Golden, N. M., Ting, J. Y., Wong, A. A., Erdogmus, D., & Scarbrough, T. J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/19/016 · Cited by 36
Bui, Y. K., Kipps, A. K., Brook, M. M., & Moon‐Grady, A. J. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.02.006 · Cited by 33
de Winter, B. C. M., van Gelder, T., Mathôt, R. A. A., Glander, P., Junior, H. T. S., Hilbrands, L. B., Budde, K., & van Hest, R. M. (2009) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e3181b8679a · Cited by 33
Masry, A. E., Mukhtar, A. M., Sherbeny, A. M. E., Fathy, M., & El‐Meteini, M. (2009) · Anaesthesia · doi:10.1111/j.1365-2044.2008.05793.x · Cited by 33
van Berkel, A., Rao, J. U., Lenders, J. W. M., Pellegata, N. S., Küsters, B., Piscaer, I., Hermus, A. R., Plantinga, T. S., Langenhuijsen, J. F., Vriens, D., et al. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.154815 · Cited by 35
Pubertal Growth and Serum Testosterone and Estradiol Levels in Boys
Albin, A., & Norjavaara, E. (2013) · Hormone Research in Paediatrics · doi:10.1159/000353761 · Cited by 43
Vlaar, A. M. M., & Wade, D. T. (2003) · Clinical Rehabilitation · doi:10.1191/0269215503cr674oa · Cited by 33
Mark, D. G., Hayden, G. E., Ky, B., Paszczuk, A., Pugh, M., Matthews, S., Horan, A. D., Gracias, V. H., Kirkpatrick, J. N., & Dean, A. J. (2009) · Journal of Critical Care · doi:10.1016/j.jcrc.2008.07.003 · Cited by 33
RELIABILITY AND VALIDITY OF THE BURULI ULCER FUNCTIONAL LIMITATION SCORE QUESTIONNAIRE
Stienstra, Y., Dijkstra, P. U., van Wezel, M. J., van Roest, M. H. G., Beets, M. R., Zijlstra, I. A. J., Johnson, R. C., Ampadu, E. O., Gbovi, J., Zinsou, C., et al. (2005) · American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2005.72.449 · Cited by 33
Freedman, S., Lane, R. J. M., Gillett, M. K., & Guz, A. (1988) · Thorax · doi:10.1136/thx.43.8.631 · Cited by 33
Wergel‐Kolmert, U., Wisén, A. G. M., & Wohlfart, B. (2002) · Clinical Physiology and Functional Imaging · doi:10.1046/j.1475-097x.2002.00428.x · Cited by 34
Induced sputum and bronchoalveolar lavage from patients with hypersensitivity pneumonitis
D’Ippolito, R., Chetta, A. A., Foresi, A., Marangio, E., Castagnaro, A., Merlini, S., Zompatori, M., & Olivieri, D. (2004) · Respiratory Medicine · doi:10.1016/j.rmed.2004.03.007 · Cited by 33
New Insights Into Compliance With a Mobile Phone Diary and Pedometer Use in Sedentary Women
Fukuoka, Y., Kamitani, E., Dracup, K., & Jong, S. S. (2011) · Journal of Physical Activity and Health · doi:10.1123/jpah.8.3.398 · Cited by 33
Forman, M. R., Zhu, Y., Hernandez, L. M., Himes, J. H., Dong, Y., Danish, R. K., James, K. E., Caulfield, L. E., Kerver, J. M., Arab, L., et al. (2014) · Journal of Nutrition · doi:10.3945/jn.114.194340 · Cited by 33
A System for Wearable Monitoring of Seated Posture in Computer Users
Dunne, L. E., Walsh, P. M., Smyth, B., & Caulfield, B. M. (2007) · Springer eBooks · doi:10.1007/978-3-540-70994-7_35 · Cited by 33
Christiansen, M. (2001) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/003655101300133649 · Cited by 38
Hallway Versus Treadmill 6-Minute-Walk Tests in Patients With Chronic Obstructive Pulmonary Disease
de Almeida, F. G., Victor, E. G., & Rizzo, J. Â. (2009) · Respiratory Care · doi:10.4187/respcare.09541712 · Cited by 33
Janssen, X., Cliff, D. P., Reilly, J. J., Hinkley, T., Jones, R. A., Batterham, M. J., Ekelund, U., Brage, S., & Okely, A. D. (2013) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2013.10.252 · Cited by 39
Use of reactance to estimate transpulmonary resistance
Johnson, M., Birch, M., Carter, R., Kinsella, J., & Stevenson, R. D. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00082504 · Cited by 36
The subjective postural vertical in standing: Reliability and normative data for healthy subjects
Bergmann, J., Kreuzpointner, M.-A., Krewer, C., Bardins, S., Schepermann, A., Koenig, E., Müller, F., & Jahn, K. (2014) · Attention Perception & Psychophysics · doi:10.3758/s13414-014-0815-z · Cited by 33
Donoghue, O. A., Harrison, A. J., Laxton, P., & Jones, R. K. (2008) · Sports Biomechanics · doi:10.1080/14763140701841407 · Cited by 43
Measuring waist circumference in disabled adults
Waninge, A., Ligthart, K. A. M., Kramer, J., Hoeve, S., van der Schans, C. P., & Haisma, H. H. (2010) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2010.02.009 · Cited by 33
Criterion-related validity of the one-mile run/walk test in children aged 8–17 years
Castro‐Piñero, J., Mora, J., Montesinos, J. L. G., Sjöstróm, M., & Ruiz, J. R. (2009) · Journal of Sports Sciences · doi:10.1080/02640410802603889 · Cited by 40
Osowski, J. M., Beare, T. M., & SPECKER, B. L. (2007) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2007.05.012 · Cited by 33
Domingo, C., Canturri, E., Luján, M., Moreno, A., Espuelas, H., & Marín, A. (2006) · Archivos de Bronconeumología · doi:10.1016/s1579-2129(06)60454-0 · Cited by 33
Schliep, K. C., Schisterman, E. F., Mumford, S. L., Perkins, N. J., Ye, A., Pollack, A. Z., Zhang, C., Porucznik, C. A., VanDerslice, J. A., Stanford, J. B., et al. (2013) · American Journal of Epidemiology · doi:10.1093/aje/kws283 · Cited by 33
Cresswell, A. B., Jassem, W., Srinivasan, P., Prachalias, A. A., Sizer, E., Burnal, W., Auzinger, G. M., Muiesan, P., Rela, M., Heaton, N. D., et al. (2012) · Annals of Intensive Care · doi:10.1186/2110-5820-2-s1-s12 · Cited by 33
Hagströmer, M., Ainsworth, B. E., Kwak, L., & Bowles, H. R. (2012) · Journal of Physical Activity and Health · doi:10.1123/jpah.9.s1.s29 · Cited by 39
Tünsmeyer, J., Hopster, K., Feige, K., & Kästner, S. (2014) · Veterinary Anaesthesia and Analgesia · doi:10.1111/vaa.12203 · Cited by 33
Asymmetry assessment using cone beam CT
Sievers, M. M., Larson, B. E., Gaillard, P. R., & Wey, A. R. (2011) · The Angle Orthodontist · doi:10.2319/041711-271.1 · Cited by 33
Doherty, M., Smith, P. M., & Schroder, K. (2000) · Journal of Sports Sciences · doi:10.1080/026404100402395 · Cited by 40
Assessment of Left Atrial Volume by Contrast Enhanced Magnetic Resonance Angiography
Hauser, T. H., McClennen, S., Katsimaglis, G., Josephson, M. E., Manning, W. J., & Yeon, S. B. (2004) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-120030568 · Cited by 34
Berlowitz, D. J., Spong, J., O’Donoghue, F. J., Pierce, R. J., Brown, D. J., Campbell, D. A., CATCHESIDE, P. G., Gordon, I., & Rochford, P. D. (2011) · Respiratory Care · doi:10.4187/respcare.00454 · Cited by 33
Low, G., Owen, N. E., Joubert, I., Patterson, A. J., Graves, M. J., Glaser, K. J., Alexander, G., & Lomas, D. J. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24826 · Cited by 34
Bell, L., Golley, R. K., & Magarey, A. (2014) · British Journal Of Nutrition · doi:10.1017/s0007114514001184 · Cited by 40
Meschede, D., Keck, C., Zander, M., Cooper, T. G., YEUNG, C. ‐., & Nieschlag, E. (1993) · International Journal of Andrology · doi:10.1111/j.1365-2605.1993.tb01363.x · Cited by 38
Kudo, S., Vennell, R., & Wilson, B. D. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.04.002 · Cited by 47
Validity and reliability of the SPORTS score
Blonna, D., Castoldi, F., D’Elicio, D., Bruzzone, M., Dettoni, F., Bonasia, D. E., & Rossi, R. (2011) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-011-1608-8 · Cited by 33
Brouwer, A. F. J., Roorda, R. J., & Brand, P. L. P. (2007) · Pediatric Pulmonology · doi:10.1002/ppul.20660 · Cited by 33
A cultural comparison of treatment need
Ngom, P. I., Brown, R., Diagne, F., Normand, F., & Richmond, S. (2005) · European Journal of Orthodontics · doi:10.1093/ejo/cji030 · Cited by 33
The reliability of telephone interviews compared with in-person interviews using memory aids
Cook, L. S., White, J. L., Stuart, G. C. E., & Magliocco, A. M. (2003) · Annals of Epidemiology · doi:10.1016/s1047-2797(03)00039-5 · Cited by 40
Nasal and bronchial airway epithelial cell mediator release in children
Pringle, E., Richardson, H. B., Miller, D., Spiteri-Cornish, D., Devereux, G. S., Walsh, G. M., & Turner, S. (2012) · Pediatric Pulmonology · doi:10.1002/ppul.22672 · Cited by 33
Use of Saliva in Therapeutic Drug Monitoring of Caffeine in Preterm Infants
de Wildt, S. N., Kerkvliet, K. T., Wezenberg, M. G. A., Ottink, S., Hop, W. C. J., Vulto, A. G., & Anker, J. N. V. D. (2001) · Therapeutic Drug Monitoring · doi:10.1097/00007691-200106000-00011 · Cited by 33
Uhlin, F., Fridolin, I., Lindberg, L., & Magnusson, M. (2005) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfi026 · Cited by 33
Demura, K., Morikawa, S., Murakami, K., Sato, K., Shiomi, H., Naka, S., Kurumi, Y., Inubushi, T., & Tani, T. (2006) · Journal of Surgical Research · doi:10.1016/j.jss.2006.02.016 · Cited by 33
Valentine, A. R., & Tanumihardjo, S. A. (2004) · Journal of Nutrition · doi:10.1093/jn/134.5.1186 · Cited by 34
A Novel Approach for Lactate Threshold Assessment Based on Rating of Perceived Exertion
Fabre, N., Mourot, L., Zerbini, L., Pellegrini, B., Bortolan, L., & Schena, F. F. (2013) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.8.3.263 · Cited by 36
Gower, S. T., Quigg, C. A., Hunt, J. O., Wallace, S. K. A., & Myles, P. S. (2006) · Anaesthesia and Intensive Care · doi:10.1177/0310057x0603400514 · Cited by 38
Reproducibility of functional aortic analysis using magnetic resonance imaging: the MESA
Noda, C., Ambale‐Venkatesh, B., Ohyama, Y., Liu, C., Chamera, E. H., Redheuil, A. B., Teixidó‐Turà, G., Chugh, A. R., Wu, C. O., Hundley, W. G., et al. (2015) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jev215 · Cited by 33
Li, Z., Baker, W. B., Parthasarathy, A. B., Ko, T. S., Wang, D., Schenkel, S. S., Durduran, T., Li, G., & Yodh, A. G. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.12.125005 · Cited by 37
Clinical Agreement in Quantitative Measurements
Indrayan, A. (2013) · Springer series on epidemiology and public health · doi:10.1007/978-3-642-37131-8_2 · Cited by 33
Isometric hand grip strength measured by the Nintendo Wii Balance Board – a reliable new method
Blomkvist, A. W., Andersen, S., de Bruin, E. D., & Jørgensen, M. G. (2016) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-016-0907-0 · Cited by 38
Yıldırım, N., Şahin, A., Başmak, H., & Bal, C. (2007) · Journal of Pediatric Ophthalmology & Strabismus · doi:10.3928/01913913-20070701-02 · Cited by 33
Rimoldi, O. E., Schäfers, K. P., Boellaard, R., Turkheimer, F., Stegger, L., Law, M. P., Lammertsma, A. A., & Camici, P. G. (2006) · PubMed · Cited by 33
Urbina, J., Sotelo, J. A., Springmüller, D., Montalba, C., Letelier, K., Cristián Tejos, N., Pablo Irarrázaval, M., Andía, M. E., Razavi, R., Valverde, I., et al. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25208 · Cited by 33
Single Breath-Hold T1ρ-Mapping of the Heart for Endogenous Assessment of Myocardial Fibrosis
van Oorschot, J. W. M., Visser, F., Eikendal, A. L. M., Vonken, E.-J. P. A., Luijten, P. R., Chamuleau, S. A. J., Leiner, T., & Zwanenburg, J. J. M. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000261 · Cited by 35
Rate discrimination, gap detection and ranking of temporal pitch in cochlear implant users
Cosentino, S., Carlyon, R. P., Deeks, J. M., Parkinson, W. S., & Bierer, J. A. (2016) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-016-0569-5 · Cited by 33
Lee, S., Lee, J., Hwang, J., Shin, J., Kim, T.-H., & Sk, K. (2016) · Scandinavian Journal of Rheumatology · doi:10.3109/03009742.2016.1150506 · Cited by 33
Eick, G. N., Urlacher, S. S., McDade, T. W., Kowal, P. R., & Snodgrass, J. J. (2016) · Biodemography and Social Biology · doi:10.1080/19485565.2016.1169396 · Cited by 35
Kaplanoğlu, H., & Beton, O. (2016) · Surgical and Radiologic Anatomy · doi:10.1007/s00276-016-1750-6 · Cited by 33
Gatta, G., Cortesi, M., & Zamparo, P. (2016) · PLoS ONE · doi:10.1371/journal.pone.0162387 · Cited by 33
Haap, M. M., Roth, H. J., Huber, T., Dittmann, H., & Wahl, R. (2017) · Scientific Reports · doi:10.1038/srep39835 · Cited by 38
Krishnamoorthy, P. M., Vengrenyuk, Y., Ueda, H., Yoshimura, T., Pena, J., Motoyama, S., Baber, U., Hasan, C. M., Kesanakurthy, S., Sweeny, J. M., et al. (2017) · EuroIntervention · doi:10.4244/eij-d-16-00139 · Cited by 36
Miyagi, W. E., de Poli, R. A. B., Papoti, M., Bertuzzi, R., & Zagatto, A. M. (2017) · Scientific Reports · doi:10.1038/srep42485 · Cited by 41
Keiser, S., Meinild‐Lundby, A., Steiner, T., Trösch, S., Rauber, S., Krafft, A., Burkhardt, T., Hilty, M. P., Siebenmann, C., Wehrlin, J. P., et al. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2016.1271908 · Cited by 37
Nardelli, M., Greco, A., Bolea, J., Valenza, G., Scilingo, E. P., & Bailón, R. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2694999 · Cited by 39
Popovic, V., Zerahn, B., & Heaf, J. G. (2017) · Journal of Renal Nutrition · doi:10.1053/j.jrn.2017.03.003 · Cited by 37
Dail, R. B., Holditch‐Davis, D., Sloane, R. J., Guenther, B. D., & Katz, L. M. (2017) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2017.06.005 · Cited by 33
van Houdt, P. J., Agarwal, H. K., van Buuren, L. D., Heijmink, S. W. T. P. J., Haack, S., van der Poel, H. G., Ghobadi, G., Pos, F. J., Peeters, J., Choyke, P. L., et al. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26816 · Cited by 33
Pyrocarbon interposition shoulder arthroplasty in advanced collapse of the humeral head
Hudek, R., Werner, B. S., Abdelkawi, A. F., & Gohlke, F. (2017) · Der Orthopäde · doi:10.1007/s00132-017-3495-2 · Cited by 33
Yamako, G., Chosa, E., Totoribe, K., Fukao, Y., & Deng, G. (2017) · PLoS ONE · doi:10.1371/journal.pone.0188165 · Cited by 39
López-Taylor, J. R., González-Mendoza, R. G., Gaytán-González, A., Jiménez-Alvarado, J. A., Villegas-Balcázar, M., Jáuregui-Ulloa, E. E., & Torres-Naranjo, F. (2018) · Journal of Sports Medicine · doi:10.1155/2018/6843792 · Cited by 30
Juerchott, A., Saleem, M. A., Hilgenfeld, T., Freudlsperger, C., Zingler, S., Lux, C. J., Bendszus, M., & Heiland, S. (2018) · Scientific Reports · doi:10.1038/s41598-018-31384-8 · Cited by 33
Rauseo, M., Mirabella, L., Grasso, S., Cotoia, A., Spadaro, S., D’Antini, D., Valentino, F., Tullo, L., Loizzi, D., Sollitto, F., et al. (2018) · BMC Anesthesiology · doi:10.1186/s12871-018-0624-3 · Cited by 33
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.