STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 14,701–14,800 of 47,868
Samama, C., Quezada, R. S., Riou, B., Mourgeon, E., Arock, M., Ankri, A., & VIARS, P. (1994) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1994.tb03880.x · Cited by 34
Ambulatory Monitoring of Arterial Oxygen Saturation
Decker, M. J., Hoekje, P. L., & Strohl, K. P. (1989) · CHEST Journal · doi:10.1378/chest.95.4.717 · Cited by 34
Chandra, S., Bahl, V. K., Reddy, S. C. B., Bhargava, B., Malhotra, A., & Wasir, H. S. (1997) · American Heart Journal · doi:10.1016/s0002-8703(97)70233-3 · Cited by 34
Kautzner, J., Gang, Y., Kishore, R., Copie, X., Janota, T., Nagayoshi, H., Camm, A. J., & Malík, M. (1996) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.1996.tb00291.x · Cited by 34
Wolfisberg, H., Schmutz, A., Stotzer, R., & Thormann, W. (1993) · Journal of Chromatography A · doi:10.1016/0021-9673(93)83260-y · Cited by 34
Comparability of the tandem-R andIMx assays for the measurement of serum prostate-specific antigen
Jacobsen, S. J., Lilja, H. G., Klee, G. G., Wright, G. L., Pettersson, K. S. I., & Oesterling, J. E. (1994) · Urology · doi:10.1016/s0090-4295(94)80049-9 · Cited by 34
RING, H. A., Trimble, M., Costa, D. C., George, M. S., Verhoeff, P. N. L. G., & Ell, P. J. (1992) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.55.9.758 · Cited by 34
Lee, T. ‐., Sakahara, N., Fiebig, E. W., Hirschkorn, D. F., Johnson, D., & Busch, M. P. (1998) · Transfusion · doi:10.1046/j.1537-2995.1998.38398222870.x · Cited by 34
Summers, L. K. M., Arner, P., Ilic, V., Clark, M. L., Humphreys, S. M., & Frayn, K. N. (1998) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1998.274.4.e651 · Cited by 37
Armon, M. P., Whitaker, S. C., Gregson, R. H. S., Wenham, P. W., & Hopkinson, B. R. (1998) · Journal of Endovascular Therapy · doi:10.1177/152660289800500306 · Cited by 34
Dye, L., Mansfield, M. W., Lasikiewicz, N., Mahawish, L., Schnell, R., Talbot, D. C. S., Chauhan, H. J., Croden, F., & Lawton, C. L. (2009) · British Journal Of Nutrition · doi:10.1017/s0007114509991504 · Cited by 37
Theodorou, A. S., Cooke, C. B., King, R. F. G. J., Hood, C., Denison, T., Wainwright, B. G., & Havenetidis, K. (1999) · Journal of Sports Sciences · doi:10.1080/026404199365416 · Cited by 33
Interrater and intrarater reliability in the diagnosis and staging of endometriosis
Schliep, K. C., Stanford, J. B., Chen, Z., Zhang, B., Dorais, J. K., Boiman Johnstone, E., Hammoud, A. O., Varner, M. W., Louis, G. M. B., & Peterson, C. M. (2012) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e31825bc6cf · Cited by 33
Revivo, G., Amstutz, D. K., Gagnon, C. M., & McCormick, Z. L. (2019) · PM&R · doi:10.1016/j.pmrj.2018.06.018 · Cited by 33
Muscle Oxygen Saturation Breakpoints Reflect Ventilatory Thresholds in Both Cycling and Running
Feldmann, A., Ammann, L., Gächter, F., Zibung, M., & Erlacher, D. (2022) · Journal of Human Kinetics · doi:10.2478/hukin-2022-0054 · Cited by 41
Comparing Three Devices for Jump Height Measurement in a Heterogeneous Group of Subjects
Magnúsdóttir, Á., orgilsson, B., & Karlsson, B. (2014) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000000464 · Cited by 33
Screening for obstructive sleep apnea using a contact-free system compared with polysomnography
Zhao, R. Z., Xue, J., Dong, X. S., Zhi, H., Chen, J., Zhao, L., Zhang, X., Li, J., Penzel, T., & Han, F. (2021) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.9138 · Cited by 34
Delhaye, E., Bouvet, A., Nicolas, G., Vilas‐Boas, J. P., Bideau, B., & Bideau, N. (2022) · Sensors · doi:10.3390/s22155786 · Cited by 36
Update and Novel Validation of a Pregnancy Physical Activity Questionnaire
Chasan‐Taber, L., Park, S., Marcotte, R. T., STAUDENMAYER, J. W., Strath, S. J., & Freedson, P. S. (2023) · American Journal of Epidemiology · doi:10.1093/aje/kwad130 · Cited by 47
Phu, J., Wang, H., & Kalloniatis, M. (2023) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13229 · Cited by 33
Validity and reliability of Nike + Fuelband for estimating physical activity energy expenditure
Tucker, W. J., Bhammar, D. M., Sawyer, B. J., Buman, M. P., & Gaesser, G. A. (2015) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-015-0008-7 · Cited by 34
Dried blood spot analysis for therapeutic drug monitoring of pazopanib
de Wit, D., den Hartigh, J., Gelderblom, H. A. J., Qian, Y., den Hollander, M., Verheul, H. M. W., Guchelaar, H., & van Erp, N. P. (2015) · The Journal of Clinical Pharmacology · doi:10.1002/jcph.558 · Cited by 33
Normal T2 map profile of the entire femoral cartilage using an angle/layer‐dependent approach
Kaneko, Y., Nozaki, T., Yu, H. J., Chang, A., Kaneshiro, K., Schwarzkopf, R. M., Hara, T., & Yoshioka, H. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24936 · Cited by 33
Tepper, L. A., Caudri, D., Utens, E. M. W. J., van der Wiel, E. C., Quittner, A. L., & Tiddens, H. A. W. M. (2014) · Pediatric Pulmonology · doi:10.1002/ppul.22991 · Cited by 33
Weir, R. R., Carson, E. L., Mulhern, M. S., Laird, E. J., Healy, M. J., & Pourshahidi, L. K. (2015) · Journal of Human Nutrition and Dietetics · doi:10.1111/jhn.12328 · Cited by 34
Zhang, X., Chen, Z., Wang, L., Yang, W., Li, D., & Jin, Z. M. (2015) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411915589115 · Cited by 34
Miguelez, J., Moskovich, M., Cuckle, H., Zugaib, M., Bunduki, V., & Maymon, R. (2010) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2010.29.12.1741 · Cited by 33
Panthier, C., Querques, G., Puche, N., Tien, V. L., Blanco-Garavito, R., Béchet, S., Massamba, N., & Souied, E. H. (2013) · Retina · doi:10.1097/01.iae.0000433986.32991.1e · Cited by 33
Contrast Sensitivity Perimetry and Clinical Measures of Glaucomatous Damage
Swanson, W. H., Malinovsky, V. E., Dul, M. W., Malik, R., Torbit, J. K., Sutton, B., & Horner, D. G. (2014) · Optometry and Vision Science · doi:10.1097/opx.0000000000000395 · Cited by 34
Springer, I., Müller, M. C., Hamm, B., & Dewey, M. (2011) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.01.113 · Cited by 34
Ughi, G. J., Adriaenssens, T., Desmet, W., & D’hooge, J. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.003291 · Cited by 33
Botaro, B. G., Cortinhas, C. S., Março, L. V., Moreno, J. F. G., Silva, L. F. P. E., Benites, N. R., & dos Santos, M. V. (2013) · Journal of Dairy Science · doi:10.3168/jds.2013-6559 · Cited by 33
Wang, L., Poon, C. C. Y., & Zhang, Y. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/5/008 · Cited by 36
Measurement properties of the Work Limitations Questionnaire were sufficient among cancer survivors
Tamminga, S. J., Verbeek, J. H. A. M., Frings‐Dresen, M. H. W., & de Boer, A. G. E. M. (2013) · Quality of Life Research · doi:10.1007/s11136-013-0484-8 · Cited by 38
Pneumatic tube transport affects platelet function measured by multiplate electrode aggregometry
Thalén, S., Forsling, I., Eintrei, J., Söderblom, L., & Antović, J. P. (2013) · Thrombosis Research · doi:10.1016/j.thromres.2013.04.020 · Cited by 33
Zuvela, E., Walls, M. L., & MATSON, P. L. (2013) · Reproductive Biology · doi:10.1016/j.repbio.2013.04.005 · Cited by 33
A comparison of technologies used for estimation of body temperature
Mangat, J., Standley, T. D. A., Prevost, A. T., Vasconcelos, J. C., & White, P. A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/003 · Cited by 33
Quantification of Ghosting Produced With Presbyopic Contact Lens Correction
Kollbaum, P. S., Dietmeier, B. M., Jansen, M. E., & Rickert, M. E. (2012) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0b013e31825aa879 · Cited by 33
España‐Romero, V., Golubić, R., Martin, K. R., Hardy, R., Ekelund, U., Kuh, D. J., Wareham, N. J., Cooper, R., Brage, S., & teams, O. B. O. T. N. S. A. D. C. (2014) · PLoS ONE · doi:10.1371/journal.pone.0087085 · Cited by 41
Toyono, M., Krasuski, R. A., Pettersson, G., Matsumura, Y., Yamano, T., & Shiota, T. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2009.05.017 · Cited by 33
Accuracy of Temporal Artery Thermometry in Neonatal Intensive Care Infants
Lee, G., Flannery-Bergey, D., Randall-Rollins, K., Curry, D., Rowe, S., Teague, M. V., Tuininga, C., & Schroeder, S. (2011) · Advances in Neonatal Care · doi:10.1097/anc.0b013e3182087d2b · Cited by 33
López, E., Grabar, S., Barbier, A., KRAUSS, B. S., Jarreau, P., & Moriette, G. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1647-5 · Cited by 33
Marquié, L., Duarte, L. R., Mariné, C., Lauque, D., & Sorum, P. C. (2008) · Acute Pain · doi:10.1016/j.acpain.2008.01.003 · Cited by 296
Hamilton, P. A., Marcos, L. S., & Secic, M. (2013) · Journal of Clinical Nursing · doi:10.1111/jocn.12060 · Cited by 33
Maas, C., Ringwald, C., Weber, K., Engel, C., Poets, C. F., Binder, G., & Bassler, D. (2014) · Neonatology · doi:10.1159/000357555 · Cited by 33
Maisonobe, J.-A., Garcia, C. A., Nécib, H., Vanderlinden, B., Hendlisz, A., Flamen, P., & Buvat, I. (2012) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-012-2274-x · Cited by 36
Comparison of algorithms to determine jump height and flight time from body mounted accelerometers
Monnet, T., Decatoire, A., & Lacouture, P. (2014) · Sports Engineering · doi:10.1007/s12283-014-0155-1 · Cited by 37
Kacere, R. D., Pereyra, M., Nemeth, M. A., Muthupillai, R., & Flamm, S. D. (2005) · Radiology · doi:10.1148/radiol.2353030995 · Cited by 35
Bongers, B. C., Werkman, M. S., Blokland, D., Eijsermans, R. M. J. C., van der Torre, P., Bartels, B., Verschuren, O. W., & Takken, T. (2015) · Pediatric Exercise Science · doi:10.1123/pes.2014-0078 · Cited by 33
Kerr, A., Slater, G., Byrne, N. M., & Chaseling, J. (2015) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2014-0188 · Cited by 34
Quantitative measurement of syndesmophyte volume and height in ankylosing spondylitis using CT
Tan, S., Yao, J., Flynn, J. A., Yao, L., & Ward, M. M. (2013) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2012-202661 · Cited by 33
Reliability of Cycling Gross Efficiency Using the Douglas Bag Method
Hopker, J., Jobson, S., Gregson, H. C., Coleman, D. A., & Passfield, L. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31822cb0d2 · Cited by 43
Zhao, M., Zou, J., Wang, W., & Li, J. (2007) · Clinical and Experimental Ophthalmology · doi:10.1111/j.1442-9071.2007.01633.x · Cited by 33
Poulsen, E., Christensen, H. W., Penny, J. Ø., Overgaard, S., Vach, W., & Hartvigsen, J. (2012) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-13-242 · Cited by 36
Validation of Computerized Automatic Calculation of the Sequential Organ Failure Assessment Score
Harrison, A. M., Yadav, H., Pickering, B. W., Cartin‐Ceba, R., & Herasevich, V. (2013) · Critical Care Research and Practice · doi:10.1155/2013/975672 · Cited by 34
Barkauskas, K. J., Rajiah, P. S., Ashwath, R. C., Hamilton, J., Chen, Y., Ma, D., Wright, K. L., Gulani, V., Griswold, M. A., & Seiberlich, N. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-014-0065-1 · Cited by 33
Smith, J. A. J., Papich, M. G., Russell, G., & Mitchell, M. A. (2010) · Journal of Zoo and Wildlife Medicine · doi:10.1638/2010-0019.1 · Cited by 38
Explorations in statistics: correlation
Curran‐Everett, D. (2010) · AJP Advances in Physiology Education · doi:10.1152/advan.00068.2010 · Cited by 36
Martindale, J. H., Sutton, C., & Goodacre, L. (2012) · Clinical Rheumatology · doi:10.1007/s10067-012-2057-6 · Cited by 33
Rathleff, M. S., Thorborg, K., & Bandholm, T. (2013) · PLoS ONE · doi:10.1371/journal.pone.0068172 · Cited by 34
Predicting fluid responsiveness with transthoracic echocardiography is not yet evidence based
Wetterslev, M., Haase, N., JOHANSEN, R. R., & Perner, A. (2012) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.12045 · Cited by 33
Pineau, V., Lebel, B., Gouzy, S., Dutheil, J.-J., & Vielpeau, C. (2010) · Orthopaedics & Traumatology Surgery & Research · doi:10.1016/j.otsr.2010.04.007 · Cited by 33
Delanaye, P., Cavalier, E., Moranne, O. P., Lutteri, L., Krzesinski, J.-M., & Bruyère, O. (2013) · BMC Nephrology · doi:10.1186/1471-2369-14-57 · Cited by 42
Validity of the Actical activity monitor for assessing steps and energy expenditure during walking
Johnson, M. J., Meltz, K., Hart, K., Schmudlach, M., Clarkson, L., & Borman, K. (2014) · Journal of Sports Sciences · doi:10.1080/02640414.2014.964747 · Cited by 37
Chen, Z., Li, J., Liu, J., Cai, X., Yuan, J., Deng, D., & Yu, M. (2016) · Scientific Reports · doi:10.1038/srep20187 · Cited by 38
Agreement between health utility instruments in cochlear implantation
Ramakers, G. G. J., Smulders, Y. E., van Zon, A., Kraaijenga, V. J. C., Stegeman, I., van Zanten, G. A., & Grolman, W. (2016) · Clinical Otolaryngology · doi:10.1111/coa.12626 · Cited by 33
Estimation of Energy Expenditure for Wheelchair Users Using a Physical Activity Monitoring System
Hiremath, S. V., Intille, S. S., Kelleher, A. R., Cooper, R. A., & Ding, D. (2016) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2016.02.016 · Cited by 38
Shayeb, K. N. A., Turner, W., & Gillam, D. G. (2014) · Primary Dental Journal · doi:10.1308/205016814812736619 · Cited by 41
Noradilah, M. J., Ang, Y. N., Kamaruddin, N. A., Deurenberg, P., Ismail, M. N., & Poh, B. K. (2016) · Asia Pacific Journal of Public Health · doi:10.1177/1010539516641505 · Cited by 44
Almeida, G. J., Irrgang, J. J., Fitzgerald, G. K., Jakicic, J. M., & Piva, S. R. (2016) · Physical Therapy · doi:10.2522/ptj.20150407 · Cited by 39
Lakhal, K., Martin, M., Faiz, S., Ehrmann, S., Blanloeil, Y., Asehnoune, K., Rozec, B. R., & Boulain, T. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001324 · Cited by 33
Validity and reliability of elastic resistance bands for measuring shoulder muscle strength
Andersen, L. L., Vinstrup, J., Jakobsen, M. D., & Sundstrup, E. (2016) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.12695 · Cited by 39
Chamchod, S., Fuller, C. D., Mohamed, A., Grossberg, A. J., Messer, J. A., Heukelom, J., Gunn, G. B., Kantor, M. E., Eichelberger, H., Garden, A. S., et al. (2016) · Oral Oncology · doi:10.1016/j.oraloncology.2016.08.012 · Cited by 38
Kappen, I. F. P. M., Bittermann, G. K. P., Schouten, R. M., Bittermann, D., Etty, E. J., Koole, R., Kon, M., van der Molen, A. B. M., & Breugem, C. C. (2016) · Clinical Oral Investigations · doi:10.1007/s00784-016-1949-2 · Cited by 33
Johnson, S. B., Clayton, J. M., Butow, P. N., Silvester, W., Detering, K. M., Hall, J. P., Kiely, B. E., Cebon, J. S., Clarke, S. J., Bell, M. L., et al. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-012387 · Cited by 36
Elvas, L., Brito, D., Areia, M., Carvalho, R., Alves, S., Saraiva, S., & Cadime, A. T. (2016) · GE Portuguese Journal of Gastroenterology · doi:10.1159/000450594 · Cited by 33
Sommerlad, A., Singleton, D., Jones, R., Banerjee, S., & Livingston, G. (2017) · Alzheimer s & Dementia Diagnosis Assessment & Disease Monitoring · doi:10.1016/j.dadm.2017.02.001 · Cited by 38
Simons, M., Kee, E. G., Kimble, R. M., & Tyack, Z. F. (2017) · Burns · doi:10.1016/j.burns.2017.01.034 · Cited by 33
Cai, W., Fan, Y., Hu, H., Xiang, N., Fang, C., & Jia, F. (2017) · Surgical Oncology · doi:10.1016/j.suronc.2017.03.006 · Cited by 35
Automatic image quality assessment and measurement of fetal head in two-dimensional ultrasound image
Zhang, L., Dudley, N. J., Lambrou, T., Allinson, N. M., & Ye, X. (2017) · Journal of medical imaging · doi:10.1117/1.jmi.4.2.024001 · Cited by 36
Adrion, F., Kapun, A., Holland, E.-M., Staiger, M., Löb, P., & Gallmann, E. (2017) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2017.06.004 · Cited by 33
Messias, L. H. D., Gobatto, C. A., Beck, W. R., & Manchado-Gobatto, F. D. B. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00389 · Cited by 30
Adler, C., Steinbrecher, A., Jaeschke, L., Mähler, A., Boschmann, M., Jeran, S., & Pischon, T. (2017) · PLoS ONE · doi:10.1371/journal.pone.0180201 · Cited by 39
The Location of the Deepest Point of the Eyeball Determines the Optic Disc Configuration
Kim, Y. C., Jung, Y., Park, H.-Y. L., & Park, C. K. (2017) · Scientific Reports · doi:10.1038/s41598-017-06072-8 · Cited by 34
Kozák, L. R., van Graan, L. A., Chaudhary, U. J., Szabó, Á., & Lemieux, L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.09.014 · Cited by 37
Ma, W., Yin, X., Zhang, R., Liu, F., Yang, D., Fan, Y., Rong, J., Tian, M., & Yu, Y. (2017) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph14101211 · Cited by 34
Comparison of an adaptive local thresholding method on CBCT and µ CT endodontic images
Michetti, J., Basarab, A., Diemer, F., & Kouamé, D. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa90ff · Cited by 33
Lenoir, A., Trachsel, D. S., Younes, M., Barrey, É., & Robert, C. (2017) · Frontiers in Veterinary Science · doi:10.3389/fvets.2017.00170 · Cited by 33
Sanabria, S. J., Göksel, O., Martini, K., Forte, S., Frauenfelder, T., Huch, R., & Rominger, M. B. (2018) · European Radiology · doi:10.1007/s00330-017-5287-9 · Cited by 33
Vannebo, K. T., Iversen, V. M., Fimland, M. S., & Mork, P. J. (2018) · Journal of Back and Musculoskeletal Rehabilitation · doi:10.3233/bmr-170829 · Cited by 33
Ferri‐Morales, A., Ferreira, M. V. N., Vlachopoulos, D., Ubago‐Guisado, E., Torres-Costoso, A. I., de Moraes, A. C. F., BARKER, A. R., Moreno, L. A., Martínez‐Vizcaíno, V., & Gracia‐Marco, L. (2018) · Pediatric Exercise Science · doi:10.1123/pes.2017-0171 · Cited by 39
Smits, J. M., Nossent, G. D., Evrard, P., Láng, G., Knoop, C., Erp, J. M. K., Langer, F., Schramm, R., van de Graaf, E. A., Vos, R., et al. (2018) · Transplant International · doi:10.1111/tri.13262 · Cited by 34
Saba, L., Mallarini, G., Sanfilippo, R., Zeng, G., Montisci, R., & Suri, J. S. (2012) · Europe PMC (PubMed Central) · doi:10.3978/j.issn.2223-3652.2011.11.01 · Cited by 33
Pilotto, A., Veronese, N., Guerrero, K. L. Q., Zora, S., Boone, A. L. D., Puntoni, M., Giorgeschi, A., Cella, A., Hidalgo, I. R., Pers, Y., et al. (2018) · Rejuvenation Research · doi:10.1089/rej.2018.2103 · Cited by 39
Pulmonary vascular pruning in smokers with bronchiectasis
Díaz, A. A., Maselli, D. J., Rahaghi, F. N., Come, C. E., Yen, A., MacLean, E. S., Okajima, Y., Martinez, C. H., Yamashiro, T., Lynch, D. A., et al. (2018) · ERJ Open Research · doi:10.1183/23120541.00044-2018 · Cited by 35
Quantifying hitting activity in tennis with racket sensors: new dawn or false dawn?
Keaney, E. M., & Reid, M. M. (2018) · Sports Biomechanics · doi:10.1080/14763141.2018.1535619 · Cited by 33
Li, X., Wu, S., Li, D., Yu, T., Zhu, H., Song, Y., Meng, L., Fan, H., & Xie, L. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26604 · Cited by 33
The SonicHand Protocol for Rehabilitation of Hand Motor Function: A Validation and Feasibility Study
Colombo, R., Raglio, A., Panigazzi, M., Mazzone, A., Bazzini, G., Imarisio, C., Molteni, D., Caltagirone, C., & Imbriani, M. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2905076 · Cited by 35
Coherence and reliability of a wearable inertial measurement unit for measuring postural sway
Hansson, E. E., & Tornberg, Å. B. (2019) · BMC Research Notes · doi:10.1186/s13104-019-4238-8 · Cited by 36
Reliability of mobility measures in older medical patients with cognitive impairment
Braun, T., Thiel, C., Schulz, R. J., & Grüneberg, C. (2019) · BMC Geriatrics · doi:10.1186/s12877-019-1036-z · Cited by 37
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.