STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 15,101–15,200 of 47,868
McNulty, S. E., Roy, J., Torjman, M. C., & Seltzer, J. L. (1990) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf02828284 · Cited by 33
Inoue, H., Aizawa, H., Fukuyama, S., Takata, S., Matsumoto, K., Shigyo, M., Koto, H., & Hara, N. (1999) · Lung · doi:10.1007/pl00007627 · Cited by 33
Steady‐State versus Non‐Steady‐State QT‐RR Relationships in 24‐hour Holter Recordings
Lande, G., Funck‐Brentano, C., Ghadanfar, M. M., & Escande, D. (2000) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2000.tb06752.x · Cited by 36
Nichols, K. J., DePuey, E. G., Rozanski, A., Salensky, H., & Friedman, M. I. (1997) · PubMed · Cited by 33
Teigen, L. M., Kuchnia, A. J., Nagel, E., Deuth, C., Vock, D. M., Mulasi, U., & Earthman, C. P. (2017) · Journal of Parenteral and Enteral Nutrition · doi:10.1002/jpen.1036 · Cited by 39
Management of Lung Nodules Detected by Volume CT Scanning
Bölükbas, S., Eberlein, M. H., & Schirren, J. (2010) · New England Journal of Medicine · doi:10.1056/nejmc0912888 · Cited by 33
Yoshida, M., Murayama, R., Ota, E., Nakata, M., Kozuma, S., & Homma, Y. (2013) · International Urogynecology Journal · doi:10.1007/s00192-012-1962-1 · Cited by 32
Devine, J. K., Chinoy, E. D., Markwald, R. R., Schwartz, L. P., & Hursh, S. R. (2020) · Sensors · doi:10.3390/s21010076 · Cited by 32
Antonini-Canterin, F., Moura, L. M., Enache, R., Leiballi, E., Pavan, D., Piazza, R., Popescu, B. A., Ginghină, C., Nicolosi, G. L., & Rajamannan, N. M. (2010) · Circulation · doi:10.1161/circulationaha.109.891598 · Cited by 32
Lukic, Y. X., Teepe, G. W., Fleisch, E., & Kowatsch, T. (2022) · JMIR Serious Games · doi:10.2196/39186 · Cited by 32
Olson, D. J. (2022) · Linguistic Approaches to Bilingualism · doi:10.1075/lab.21039.ols · Cited by 40
Development and clinical validation of CT-based regional modified Centiloid method for amyloid PET
Kim, S.-J., Ham, H., Park, Y. H., Choe, Y. S., Kim, Y. J., Jang, H., Na, D. L., Kim, H. J., Moon, S. H., & Seo, S. W. (2022) · Alzheimer s Research & Therapy · doi:10.1186/s13195-022-01099-0 · Cited by 32
Griffiths, P., Sims, J., Williams, A., Williamson, N., Cella, D. F., Brohan, E., & Cocks, K. (2022) · Quality of Life Research · doi:10.1007/s11136-022-03286-w · Cited by 41
Reliability of the active knee joint position sense test and influence of limb dominance and sex
Busch, A., Bangerter, C., Mayer, F., & Baur, H. (2023) · Scientific Reports · doi:10.1038/s41598-022-26932-2 · Cited by 36
An evaluation of mechanical and biophysical skin parameters at different body locations
John, A. J. U. K., Galdo, F. D., Gush, R., & Worsley, P. R. (2023) · Skin Research and Technology · doi:10.1111/srt.13292 · Cited by 34
Silveira, E. A., Barcelo, R., Lamas, G. C., Rodrigues, P. P. D. O., Chaves, B. S., Protásio, T. D. P., Rousset, P. L. A., & Ghesti, G. F. (2024) · Energy Conversion and Management · doi:10.1016/j.enconman.2024.118222 · Cited by 33
Screening Accuracy of BMI for Adiposity Among 8- to 19-Year-Olds
Freedman, D. S., Zemel, B. S., Dietz, W. H., & Daymont, C. B. (2024) · PEDIATRICS · doi:10.1542/peds.2024-065960 · Cited by 36
Comparing Autorefractors for Measurement of Accommodation
Aldaba, M., López, S. G., Vilaseca, M., Pujol, J., & Arjona, M. (2015) · Optometry and Vision Science · doi:10.1097/opx.0000000000000685 · Cited by 32
Unique spatial distribution ofin vivohuman muscle activation
Kinugasa, R., Kawakami, Y., Sinha, S., & Fukunaga, T. (2011) · Experimental Physiology · doi:10.1113/expphysiol.2011.057562 · Cited by 35
Vachhrajani, S. H., Sen, A. N., Satyan, K. B., Kulkarni, A. V., Birchansky, S. B., & Jea, A. H. (2014) · Journal of Neurosurgery Pediatrics · doi:10.3171/2014.7.peds13591 · Cited by 32
Sleep–wake patterns in patients with cirrhosis: All you need to know on a single sheet
Montagnese, S., Middleton, B., Skene, D. J., & Morgan, M. Y. (2009) · Journal of Hepatology · doi:10.1016/j.jhep.2009.06.006 · Cited by 34
Increased blood‐oxygen binding affinity in Tibetan and Han Chinese residents at 4200 m
Simonson, T. S., Wei, G., Wagner, H. E., Wuren, T., Bui, A., Fine, J. M., Ga, Q., Beltrami, F. G., Ma, Y., Wagner, P. D., et al. (2014) · Experimental Physiology · doi:10.1113/expphysiol.2014.080820 · Cited by 35
Ohno, Y., Nishio, M., Koyama, H., Yoshikawa, T., Matsumoto, S., Seki, S., Obara, M., CAUTEREN, M. V., Takahashi, M., & Sugimura, K. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24232 · Cited by 38
Arani, A., Rosa, M. R. D., Ramsay, E. A., Plewes, D. B., Haider, M. A., & Chopra, R. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24028 · Cited by 32
Huang, J., Savini, G., Hu, L., Hoffer, K. J., Lu, W., Feng, Y., Yang, F., Hu, X., & Wang, Q. (2012) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2012.10.034 · Cited by 32
Computer-Based Test to Measure Optimal Visual Acuity in Age-Related Macular Degeneration
González, E. G., Tarita‐Nistor, L., Markowitz, S. N., & Steinbach, M. J. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-1240 · Cited by 37
Alderliesten, T., Sonke, J., Betgen, A., van Vliet-Vroegindeweij, C., & Remeijer, P. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2012.08.016 · Cited by 32
Juráš, V., Winhofer, Y., Szomolányi, P., Vosshenrich, J., Hager, B., Wolf, P., Weber, M., Luger, A., & Trattnig, S. (2015) · Radiology · doi:10.1148/radiol.15140484 · Cited by 33
Bernard, Y. F., Morel, M., Descotes‐Genon, V., Jehl, J., Meneveau, N. F., & Schiele, F. (2013) · Echocardiography · doi:10.1111/echo.12386 · Cited by 32
Geometric Facial Gender Scoring: Objectivity of Perception
Gilani, S. Z., Rooney, K., Shafait, F., Walters, M., & Mian, A. S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0099483 · Cited by 35
Rousset, S., Fardet, A., Lacomme, P., Normand, S., Montaurier, C., Boirie, Y., & Morio, B. (2014) · European Journal of Sport Science · doi:10.1080/17461391.2014.949309 · Cited by 36
Sonographic cervical length measurement in pregnant women with a cervical pessary
Goya, M., Pratcorona, L., Higueras, T., Pérez‐Hoyos, S., Carreras, E., & Cabero, L. (2011) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.8960 · Cited by 35
Continuous Measurement of Blood Glucose: Validation of a New Intravascular Sensor
Skjærvold, N. K., Solligård, E., Hjelme, D. R., & Aadahl, P. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181ff4187 · Cited by 34
Kanamori, A., Nakamura, M., Tomioka, M., Kawaka, Y., Yamada, Y., & Negi, A. (2012) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2011-301084 · Cited by 32
Validation of the SenseWear armband in circuit resistance training with different loads
Benito, P. J., Neiva, C. M., González-Quijano, P. S., Cupeiro, R., Morencos, E., & Peinado, A. B. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2269-5 · Cited by 39
Clinical measurement and assessing agreement
Columb, M. O. (2008) · Current Anaesthesia and Critical Care · doi:10.1016/j.cacc.2008.07.001 · Cited by 32
Popovich, I., Dalbeth, N., Doyle, A., Reeves, Q., & McQueen, F. M. (2014) · Skeletal Radiology · doi:10.1007/s00256-014-1869-7 · Cited by 32
Keulenaer, B. L. D., Regli, A., Dąbrowski, W., Kaloiani, V., Bodnár, Z., Izura, J., Litvin, A., Davis, W. A., Palermo, A., Waele, J. J. D., et al. (2011) · Intensive Care Medicine · doi:10.1007/s00134-011-2298-x · Cited by 34
Yabuuchi, H., Matsuo, Y., Tsukamoto, H., Horiuchi, T., Sunami, S., Kamitani, T., Jinnouchi, M., Nagao, M., Akashi, K., & Honda, H. (2014) · Clinical Radiology · doi:10.1016/j.crad.2014.03.008 · Cited by 32
Comparison of segmentation methods for MRI measurement of cardiac function in rats
Riegler, J., Cheung, K. K., Man, Y. F., Cleary, J. O., Price, A. N., & Lythgoe, M. F. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22305 · Cited by 32
Korporaal, J. G., van den Berg, C. A. T., Jeukens, C. R. L. P. N., Groenendaal, G., Moman, M. R., Luijten, P. R., van Vulpen, M., & van der Heide, U. A. (2010) · Radiology · doi:10.1148/radiol.10092068 · Cited by 32
Martins, W. P., Ferriani, R. A., Nastri, C. O., & Filho, F. M. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.02.005 · Cited by 33
Double tracer gas single-breath washout: reproducibility in healthy subjects and COPD
Husemann, K., Berg, N., Engel, J., Port, J., Joppek, C., Tao, Z., Singer, F., Schulz, H., & Kohlhäufl, M. J. (2014) · European Respiratory Journal · doi:10.1183/09031936.00085713 · Cited by 33
Horje, C. S. H. T., Bruijnen, R. C. G., Roovers, L., Groenen, M. J. M., Joosten, F. B. M., & Wahab, P. J. (2015) · PLoS ONE · doi:10.1371/journal.pone.0136105 · Cited by 32
Eizadi‐Mood, N., Moein, N., & Saghaei, M. (2005) · Clinical Toxicology · doi:10.1081/clt-200066071 · Cited by 32
Blackman, A. V., Grabuschnig, S., Legenstein, R. A., & Sjöström, P. J. (2014) · Frontiers in Neuroanatomy · doi:10.3389/fnana.2014.00065 · Cited by 37
Westland, R., Schreuder, M. F., van der Lof, D. F., Vermeulen, A., der Meer, I. M. J. D.-V., Bökenkamp, A., & van Wijk, J. A. E. (2014) · Pediatric Nephrology · doi:10.1007/s00467-014-2853-0 · Cited by 37
Comparison of inflammatory markers in induced and spontaneous sputum in a cohort of COPD patients
Tangedal, S., Aanerud, M., Persson, L. J. P., Brokstad, K. A., Bakke, P. S., & Eagan, T. (2014) · Respiratory Research · doi:10.1186/s12931-014-0138-6 · Cited by 32
Barreto, E. Q., Milani, H. J. F., Júnior, E. A., Haratz, K. K., Rôlo, L. C., Nardozza, L. M. M., & Moron, A. F. (2010) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2010.29.5.767 · Cited by 32
Davies, S. J., Minhas, S., Wilson, R., Yates, D., & Howell, S. J. (2013) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2013.04.010 · Cited by 32
Hannon, D., Bradley, J. M., Bradbury, I., Bell, N., Elborn, J. S., & O’Neill, K. (2014) · BMJ Open Respiratory Research · doi:10.1136/bmjresp-2014-000031 · Cited by 32
Accuracy of Infrared Ear Thermometry in Children
Chen, Z., Zhang, X., Li, L., & Pu, Y. (2014) · Clinical Pediatrics · doi:10.1177/0009922814536774 · Cited by 32
Golriz, S., Hébert, J. J., Foreman, K. B., & Walker, B. F. (2012) · Chiropractic & Manual Therapies · doi:10.1186/2045-709x-20-15 · Cited by 32
Collado‐Mateo, D., Adsuar, J. C., Olivares, P. R., Cano-Plasencia, R., & Gusi, N. (2015) · Somatosensory & Motor Research · doi:10.3109/08990220.2015.1074566 · Cited by 32
Psychometric Properties of the Memory Binding Test: Test-Retest Reliability and Convergent Validity
Gramunt, N., Sánchez‐Benavides, G., Buschke, H., Lipton, R. B., Masramon, X., Gispert, J. D., Peña‐Casanova, J., Fauria, K., & Molinuevo, J. L. (2016) · Journal of Alzheimer s Disease · doi:10.3233/jad-150776 · Cited by 41
Manato, L., Pereira, T. S. S., Velásquez-Meléndez, G., Cardoso, L. D. O., Benseñor, I. M., & Molina, M. D. C. B. (2015) · Sao Paulo Medical Journal · doi:10.1590/1516-3180.2014.00533004 · Cited by 39
Li, M., Cao, J., Guo, J., Niu, J., & Xiong, M. (2015) · Meteorological Applications · doi:10.1002/met.1537 · Cited by 32
Self-perceived health in older Europeans: Does the choice of survey matter?
Croezen, S., Burdorf, A., & van Lenthe, F. J. (2016) · European Journal of Public Health · doi:10.1093/eurpub/ckw017 · Cited by 42
A practical validation study of a commercial accelerometer using good and poor sleepers
Dickinson, D. L., Cazier, J., & Cech, T. (2016) · Health Psychology Open · doi:10.1177/2055102916679012 · Cited by 32
Crespo, C., Fernández, J. R., Aboy, M., & Mojón, A. (2012) · Chronobiology International · doi:10.3109/07420528.2012.701147 · Cited by 34
Automated Segmentation of Pathological Cavities in Optical Coherence Tomography Scans
Pilch, M., Stieger, K., Wenner, Y., Preising, M. N., Friedburg, C., zu Bexten, E. M., & Lorenz, B. (2013) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-11396 · Cited by 32
Elkjær, M. (2012) · PubMed · Cited by 37
McLean, A. S., Huang, S. J., Kot, M., Rajamani, A., & Hoyling, L. (2011) · Anaesthesia and Intensive Care · doi:10.1177/0310057x1103900409 · Cited by 32
Development and validation of a vision and night driving questionnaire
Kimlin, J. A., Black, A. A., Djaja, N., & Wood, J. M. (2016) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12307 · Cited by 34
Kumar, P. K., Araki, T., Rajan, J., Saba, L., Lavra, F., Ikeda, N., Sharma, A., Shafique, S., Nicolaides, A. N., Laird, J. R., et al. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1601-y · Cited by 35
Reliability and Validity of Athletes Disability Index Questionnaire
Noormohammadpour, P., HosseiniKhezri, A., Farahbakhsh, F., Mansournia, M. A., Smuck, M. W., & Kordi, R. (2017) · Clinical Journal of Sport Medicine · doi:10.1097/jsm.0000000000000414 · Cited by 32
Roger, C., Müller, L., Riou, B., Molinari, N., Louart, B., Kerbrat, H., Teboul, J., & Lefrant, J. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew386 · Cited by 35
A novel two‐dimensional correlation coefficient for assessing associations in time series data
Dikbaş, F. (2017) · International Journal of Climatology · doi:10.1002/joc.4998 · Cited by 32
Size Measurement and T-staging of Lung Adenocarcinomas Manifesting as Solid Nodules ≤30 mm on CT
Heidinger, B. H., Anderson, K. R., Moriarty, E., Costa, D. B., Gangadharan, S. P., VanderLaan, P. A., & Bankier, A. A. (2017) · Academic Radiology · doi:10.1016/j.acra.2017.01.009 · Cited by 32
Adequacy of the Ultra-Short-Term HRV to Assess Adaptive Processes in Youth Female Basketball Players
Nakamura, F. Y., Pereira, L. A., Abad, C. C. C., Cruz, I. D. F., Flatt, A. A., Esco, M. R., & Loturco, I. (2017) · Journal of Human Kinetics · doi:10.1515/hukin-2017-0024 · Cited by 36
Two degrees of freedom quasi-static EMG-force at the wrist using a minimum number of electrodes
Clancy, E. A., Martinez-Luna, C., Wartenberg, M., Dai, C., & Farrell, T. R. (2017) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2017.03.004 · Cited by 38
Chen, H., van Eijnatten, M. A. J. M., Wolff, J., de Lange, J., van der Stelt, P. F., Lobbezoo, F., & Aarab, G. (2017) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20170043 · Cited by 32
Chaemsaithong, P., Ting, Y. H., Cheng, K. Y. Y., Poon, L. C., Leung, T. Y., & Sahota, D. S. (2017) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2017.1341481 · Cited by 33
Diagnostic precision of triage algorithms for mass casualty incidents. English version
Heller, A. R., Salvador, N., Frank, M., Schiffner, J., Kipke, R., & Kleber, C. (2017) · Der Anaesthesist · doi:10.1007/s00101-017-0352-y · Cited by 32
Hall, D. A., Mehta, R. L., & Fackrell, K. (2017) · American Journal of Audiology · doi:10.1044/2017_aja-16-0129 · Cited by 36
Robertson, A. D., Marzolini, S., Middleton, L. E., Basile, V. S., OH, P. I., & MacIntosh, B. J. (2017) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2017.00318 · Cited by 37
Analysis of free amino acids in mammalian brain extracts
Ksenofontov, A. L., Boyko, A. I., Mkrtchyan, G. V., Tashlitsky, V. N., Timofeeva, A. V., Graf, A. V., Bunik, V. I., & Baratova, L. A. (2017) · Biochemistry (Moscow) · doi:10.1134/s000629791710011x · Cited by 34
Schless, S., Hanssen, B., Cenni, F., Bar‐On, L., Aertbeliën, E., Molenaers, G., & Desloovere, K. (2017) · Developmental Medicine & Child Neurology · doi:10.1111/dmcn.13597 · Cited by 32
Smart watch, smarter EDSS: Improving disability assessment in multiple sclerosis clinical practice
Costa, G. D., Radaelli, M., Maida, S., Sangalli, F., Colombo, B., Moiola, L., Comı, G., & Martinelli, V. (2017) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2017.10.043 · Cited by 32
Lo, W. L. A., Zhao, J.-L., Chen, L., Lei, D., Huang, D. F., & Tong, K. F. (2017) · Scientific Reports · doi:10.1038/s41598-017-14107-3 · Cited by 36
Optical coherence tomography for assessment of epithelialization in a human ex vivo wound model
Glinos, G. D., Verne, S. H., Aldahan, A. S., Liang, L., Nouri, K., Elliot, S. J., Glassberg, M. K., DeBuc, D. C., Koru‐Sengul, T., Tomic‐Canic, M., et al. (2017) · Wound Repair and Regeneration · doi:10.1111/wrr.12600 · Cited by 35
Ruíz-Mesa, R., Abengózar-Vela, A., & Ruiz-Santos, M. (2017) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2017.08.016 · Cited by 32
Schuurmann, R. C. L., Overeem, S. P., van Noort, K., de Vries, B. A., Slump, C. H., & de Vries, J. P. P. M. (2018) · Journal of Endovascular Therapy · doi:10.1177/1526602818764413 · Cited by 32
Wong, A., Yiu, S., Nasreddine, Z. S., Leung, K.-T., Lau, A. Y. L., Soo, Y. O. Y., Wong, K. S., & Mok, V. (2018) · PLoS ONE · doi:10.1371/journal.pone.0196344 · Cited by 34
Zhou, Y., Höglund, P., & Clyne, N. (2018) · Journal of Renal Nutrition · doi:10.1053/j.jrn.2018.05.003 · Cited by 32
Relationship between the Ki67 index and its area based approximation in breast cancer
Niazi, M. K. K., Şenaras, Ç., Pennell, M. L., Arole, V., Tozbikian, G. H., & Gürcan, M. N. (2018) · BMC Cancer · doi:10.1186/s12885-018-4735-5 · Cited by 32
Validation of an inertial measurement unit to determine countermovement jump height
Petersen, E. T., Jørgensen, P. B., Mechlenburg, I., & Sørensen, H. (2018) · Asia-Pacific Journal of Sports Medicine Arthroscopy Rehabilitation and Technology · doi:10.1016/j.asmart.2018.09.002 · Cited by 36
An automated and objective cover test to measure heterophoria
Mestre, C., Otero, C., Díaz-Doutón, F., Gautier, J., & Pujol, J. (2018) · PLoS ONE · doi:10.1371/journal.pone.0206674 · Cited by 32
VERDICT‐AMICO: Ultrafast fitting algorithm for non‐invasive prostate microstructure characterization
Bonet-Carné, E., Johnston, E. W., Daducci, A., Jacobs, J. G., Freeman, A., Atkinson, D., Hawkes, D. J., Punwani, S., Alexander, D. C., & Panagiotaki, E. (2018) · NMR in Biomedicine · doi:10.1002/nbm.4019 · Cited by 36
Alqurashi, Y. D., Nakamura, T., Goverdovsky, V., Moss, J., Polkey, M. I., Mandic, D. P., & Morrell, M. J. (2018) · Nature and Science of Sleep · doi:10.2147/nss.s175998 · Cited by 36
Bremer, B., Anastasiou, O. E., Ciesek, S., & Wedemeyer, H. H. (2018) · Antiviral Therapy · doi:10.3851/imp3281 · Cited by 32
Kulah, K., Gülşahı, A., Kamburoğlu, K., Geneci, F., Ocak, M., Çelik, H. H., & Özen, T. (2018) · Oral Surgery Oral Medicine Oral Pathology and Oral Radiology · doi:10.1016/j.oooo.2018.11.014 · Cited by 32
Beadnall, H. N., Wang, C., Hecke, W. V., Ribbens, A., Billiet, T., & Barnett, M. H. (2019) · Therapeutic Advances in Neurological Disorders · doi:10.1177/1756286418823462 · Cited by 37
Tunstall, J., Mueller, K., White, D. G., Oultram, J. W. H., & Higgins, H. M. (2019) · Frontiers in Veterinary Science · doi:10.3389/fvets.2019.00094 · Cited by 38
MICHIELS, C., Jambon, E., & Bernhard, J. (2019) · American Journal of Roentgenology · doi:10.2214/ajr.18.21048 · Cited by 32
Microplate assay for denatured collagen using collagen hybridizing peptides
Lin, A. H., Zitnay, J. L., Li, Y., Yu, S. M., & Weiss, J. A. (2018) · Journal of Orthopaedic Research® · doi:10.1002/jor.24185 · Cited by 32
Khalil, A., Elmogy, M. M., Ghazal, M. A., Burns, C., & El-Baz, A. S. (2019) · IEEE Access · doi:10.1109/access.2019.2923962 · Cited by 33
Large Incisional Hernias Increase in Size
Jensen, K. K., Arnesen, R. B., Christensen, J. K., Bisgaard, T., & Jørgensen, L. N. (2019) · Journal of Surgical Research · doi:10.1016/j.jss.2019.06.016 · Cited by 32
Doyle, C. B., Khan, A., & Burton, N. W. (2019) · The Journal of Sports Medicine and Physical Fitness · doi:10.23736/s0022-4707.18.09186-7 · Cited by 37
Mortensen, M. A., Borrelli, P., Poulsen, M. H., Gerke, O., Enqvist, O., Ulén, J., Trägårdh, E., Constantinescu, C. M., Edenbrandt, L., Lund, L. C., et al. (2019) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12592 · Cited by 33
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.