STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 27,801–27,900 of 47,868
Zhang, Q., Liang, Y., Zhang, Q.-H., Li, R.-J., Chua, Y. L. H., Xie, J., Lee, P.-W., & Yu, C. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.11.011 · Cited by 12
Perperidis, A., Cusack, D., White, A. C., McDicken, N., MacGillivray, T., & Anderson, T. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.02.008 · Cited by 12
Absolute CD4+ cell count using a plastic microchip and a microscopic cell counter
Bae, S. Y., Park, H., Oh, J., Yoon, S., Park, D. W., Choi, I. K., Kim, H. J., Oh, J. H., Hur, D. S., Chung, C., et al. (2009) · Cytometry Part B Clinical Cytometry · doi:10.1002/cyto.b.20470 · Cited by 12
Vanvuchelen, M., & Vochten, C. (2010) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2010.09.019 · Cited by 14
Buisker, T., Dufour, M. K., & Myers, J. J. (2015) · AIDS and Behavior · doi:10.1007/s10461-015-1018-x · Cited by 13
Accuracy of Different Equations for Estimating Fetal Weight
Benavides-Serralde, A., Hernandez‐Andrade, E. A., Fernandez-Lara, A., Figueras, F., Moreno-Alvarez, O., Camargo-Marín, L., Acevedo‐Gallegos, S., Gallardo‐Gaona, J. M., Velazquez‐Torres, B., & Guzmán‐Huerta, M. (2011) · Gynecologic and Obstetric Investigation · doi:10.1159/000328693 · Cited by 13
Kaźmierski, R., Watała, C. W., Podsiadły, E., Dorszewska, J., & Kozubski, W. P. (2009) · Journal of Clinical Ultrasound · doi:10.1002/jcu.20585 · Cited by 15
A sensitive method for the analysis of glutathione in porcine hepatocytes
Florholmen-Kjær, Å., Lyså, R. A., Fuskevåg, O., Goll, R., Revhaug, A., & Mortensen, K. E. (2014) · Scandinavian Journal of Gastroenterology · doi:10.3109/00365521.2014.964757 · Cited by 14
Comparing enfant and PowerDiva sweep visual evoked potential (sVEP) acuity estimates
Ridder, W. H., Waite, B. S., & Melton, T. F. (2014) · Documenta Ophthalmologica · doi:10.1007/s10633-014-9457-7 · Cited by 12
Myou, S., Fujimura, M., Kamio, Y., Kita, T., Watanabe, K., Ishiura, Y., Hashimoto, T., & Nakao, S. (2002) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.2002.t01-4-01689.x · Cited by 14
Influence of Selected Variables on Monocular, Interocular, and Binocular Visual Acuity
Pointer, J. S. (2008) · Optometry and Vision Science · doi:10.1097/opx.0b013e318162265d · Cited by 15
Arraiza, M., Azcárate, P., Cecco, C. N. D., Viteri, G., Simón-Yarza, I., Hernández‐Estefanía, R., Rábago, G., & Bastarrika, G. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2012.04.001 · Cited by 12
A Pilot Study of Continuous Transtracheal Mixed Venous Oxygen Saturation Monitoring
Wei, W., Zhu, Z., Liu, L., Zuo, Y., Gong, M., Xue, F., & Liu, J. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000156949.91614.e9 · Cited by 12
Development and validation of the Liverpool infant bronchiolitis severity score: a research protocol
van Miert, C., Abbott, J., Verheoff, F., Lane, S., Carter, B., & McNamara, P. S. (2014) · Journal of Advanced Nursing · doi:10.1111/jan.12387 · Cited by 13
A Qualitative and Quantitative Comparison of Two Rubella Virus-Specific IgG Antibody Immunoassays
Greenwood, N. P., Ovsyannikova, I. G., Vierkant, R. A., O’Byrne, M. M., & Poland, G. A. (2010) · Viral Immunology · doi:10.1089/vim.2010.0026 · Cited by 12
Bunout, D. C., Barrera, G., de la Maza, M. P., Leiva, L., Vivien Gattas, Z., & Hirsch, S. (2007) · Nutrition · doi:10.1016/j.nut.2007.08.012 · Cited by 12
Gao, L., Xia, L., Pan, S., Xiong, T., & Li, S. (2013) · Epilepsia · doi:10.1111/epi.12324 · Cited by 15
An improved method for microbiological testing of paper-based laminates used in food packaging
Feichtinger, M., Zitz, U., Fric, H., Kneifel, W., & Domig, K. J. (2014) · Food Control · doi:10.1016/j.foodcont.2014.10.002 · Cited by 12
Abe, Y., Ishikawa, H., & Fukao, A. (2008) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.214.51 · Cited by 12
Sundholm, J. K. M., Gustavsson, T., & Sarkola, T. (2014) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2014.03.006 · Cited by 12
Hypopituitary patients prefer a touch-screen to paper quality of life questionnaire
Goodhart, I. M., Ibbotson, V., Doane, A., Roberts, B., Campbell, M. J., & Ross, R. J. M. (2005) · Growth Hormone & IGF Research · doi:10.1016/j.ghir.2005.08.002 · Cited by 12
Aortic Annulus Diameter Measurement: What Is the Best Modality?
Yano, M., Nakamura, K., Nagahama, H., Matsuyama, M., Nishimura, M., & Onitsuka, T. (2012) · Annals of Thoracic and Cardiovascular Surgery · doi:10.5761/atcs.oa.11.01727 · Cited by 12
Douglas, A. D., Jefferis, J., Sharma, R., Parker, R. J., Handa, A. I., & Chantler, J. (2009) · Angiology · doi:10.1177/0003319709332958 · Cited by 12
Gonda, M., Fang, X. D., Perry, G. A., & Maltecca, C. (2012) · Vaccine · doi:10.1016/j.vaccine.2012.08.047 · Cited by 13
Poelzl, G., Gattermeier, M., Kratzer, H., Zeindlhofer, E., & Kuehn, P. (2001) · European Journal of Heart Failure · doi:10.1016/s1388-9842(01)00166-0 · Cited by 12
Clinical evaluation of the Trimline blood pressure cuffs with the Accutorr PlusTM Monitor
White, W. B., Herbst, T., Thavarajah, S., & Giacco, S. (2003) · Blood Pressure Monitoring · doi:10.1097/00126097-200306000-00008 · Cited by 12
Seismocardiographic adjustment of diastolic timed vibrations
Tavakolian, K., Khosrow-Khavar, F., Kajbafzadeh, B., Marzencki, M., Rohani, S., Kamińska, B., & Menon, C. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346794 · Cited by 14
Abdominal Fat Assessment in Adolescents Using Dual-energy X-ray Absorptiometry
Tsang, T. W., BRIODY, J. N., Kohn, M. R., Chow, C. M., & Singh, M. F. (2009) · Journal of Pediatric Endocrinology and Metabolism · doi:10.1515/jpem.2009.22.9.781 · Cited by 14
Nilsson, T., Segstedt, S., Milton, P., Sveinsdóttir, S., Jansson, T. T., Persson, H. W., Ley, D., & Cinthio, M. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2013.09.017 · Cited by 13
Gönen, T., Cosar, C. B., Şener, B., & Keskinbora, K. H. (2012) · Journal of Refractive Surgery · doi:10.3928/1081597x-20120723-04 · Cited by 12
Hyperventilation and finger exercise increase venous-arterial Pco2 and pH differences
Umeda, A., Kawasaki, K., Abe, T., Watanabe, M., Ishizaka, A., & Okada, Y. (2008) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2007.12.001 · Cited by 12
TTCA measurements in biomonitoring of low-level exposure to carbon disulphide
Kivistö, H. (2000) · International Archives of Occupational and Environmental Health · doi:10.1007/s004200050426 · Cited by 12
Liu, Y.-H., Sahul, Z. H., Weyman, C. A., Dione, D. P., Dobrucki, L. W., Mekkaoui, C., Brennan, M. P., Ryder, W. J., & Sinusas, A. J. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.082214 · Cited by 12
Semiautomated versus Manual Evaluation of Liver Metastases Treated by Radiofrequency Ablation
Keil, S., Bruners, P., Ohnsorge, L., Plumhans, C., Behrendt, F. F., Stanzel, S. F., Sühling, M., Günther, R. W., Das, M., & Mahnken, A. H. (2010) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2009.10.024 · Cited by 12
Differences in pain perception during open muscle biopsy and Bergstroem needle muscle biopsy
Dengler, J., Linke, P., Gdynia, H., Wolf, S., Ludolph, A. C., Vajkoczy, P., & Meyer, T. (2014) · Journal of Pain Research · doi:10.2147/jpr.s69458 · Cited by 12
Determination of kidney function with 99mTc-DTPA renography using a dual-head camera
Madsen, C., Møller, M. L., Zerahn, B., Fynbo, C. A., & Jensen, J. J. (2013) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e32835f1620 · Cited by 12
Comparison of Fixation Disparity Measured by Saladin Card and Disparometer
Frantz, K. A., Elston, P., Michalik, E., Templeman, C. D., & Zoltoski, R. K. (2011) · Optometry and Vision Science · doi:10.1097/opx.0b013e318214ba6e · Cited by 12
Timed-urine collections for renal clearance studies
Hellerstein, S., Berenbom, M., Erwin, P., Wilson, N., & DiMaggio, S. (2005) · Pediatric Nephrology · doi:10.1007/s00467-005-2036-0 · Cited by 12
Evaluating theQuikRead®C-reactive protein test as a point-of-care test
Diar, H. A., Nakwa, F. L., Thomas, R., Libhaber, E. N., & Velaphi, S. (2012) · Paediatrics and International Child Health · doi:10.1179/1465328111y.0000000045 · Cited by 12
Doesch, C., Zompolou, C., Streitner, F., Haghi, D., Schimpf, R., Rudic, B., Kuschyk, J., Schoenberg, S. O., Borggrefe, M. M., & Papavassiliu, T. (2014) · Netherlands Heart Journal · doi:10.1007/s12471-014-0601-5 · Cited by 12
Tonometry in Corneal Edema after Cataract Surgery: ReboundversusGoldmann Applanation Tonometry
Fuest, M., Mamas, N., Walter, P., & Plange, N. (2014) · Current Eye Research · doi:10.3109/02713683.2014.888451 · Cited by 12
Computed tomographic evaluation of femoral component rotation in total knee arthroplasty
Vaidya, S. V., Gadhiya, R. M., Bagaria, V. B., Ranawat, A. S., & Ranawat, C. S. (2013) · Indian Journal of Orthopaedics · doi:10.4103/0019-5413.106898 · Cited by 12
Signal processing methods for non-contact cardiac detection using Doppler radar
Vasu, V., Heneghan, C., Arumugam, T., & Sezer, S. (2010) · SiPS ... design and implementation - IEEE Workshop on Signal Processing Systems · doi:10.1109/sips.2010.5624817 · Cited by 12
Béghin, L., Huybrechts, I., Ortega, F. B., Coopman, S., Μanios, Y., Wijnhoven, T. M. A., Duhamel, A., Ciarapica, D., Gilbert, C. C., Kafatos, A., et al. (2013) · Annals of Nutrition and Metabolism · doi:10.1159/000343096 · Cited by 14
Evaluation of an Internet-Based Monitoring System for Influenza-Like Illness in Sweden
Rehn, M., Carnahan, A., Merk, H., Kühlmann‐Berenzon, S., Galanis, I., Linde, A., & Nyrén, O. (2014) · PLoS ONE · doi:10.1371/journal.pone.0096740 · Cited by 12
Comparison of Power Output During Ergometer and Track Cycling in Adolescent Cyclists
Nimmerichter, A., & Williams, C. A. (2014) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000000723 · Cited by 13
Driel, R. V., Trask, C., Johnson, P. W., Callaghan, J. P., Koehoorn, M. W., & Teschke, K. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.757479 · Cited by 12
Mumcuoglu, E. U., Long, F. R., Castile, R. G., & Gürcan, M. N. (2012) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-012-9476-4 · Cited by 12
Pineau, J., Lalys, L., Pellegrini, M., & Battistini, N. (2013) · ISRN Obesity · doi:10.1155/2013/462394 · Cited by 15
Nishizawa, S., Iida, H., Tsuchida, T., Ito, H., Konishi, J., & Yonekura, Y. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1180-7 · Cited by 12
Winfield, J. M., Papoutsaki, M.-V., Ragheb, H., Morris, D. M., Heerschap, A., ter Voert, E. E. G. W., Kuijer, J. P. A., den Bos, I. C. P.-V., Douglas, N. H. M., Orton, M. R., et al. (2015) · British Journal of Radiology · doi:10.1259/bjr.20140717 · Cited by 12
Picozzi, G., Diciotti, S., Falchini, M., Foresti, S., Gallesi, F., Cavigli, E., Livi, L., Villari, N., & Mascalchi, M. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000242837.11436.6e · Cited by 12
Bandirali, M., Sconfienza, L. M., Aliprandi, A., Leo, G. D., Marchelli, D., Ulivieri, F. M., & Sardanelli, F. (2013) · La radiologia medica · doi:10.1007/s11547-013-0342-3 · Cited by 12
Reproducibility of heart rate turbulence indexes in heart failure patients
D’Addio, G., Cesarelli, M., Corbi, G., Romano, M., Furgi, G., Ferrara, N., & Rengo, F. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626653 · Cited by 12
Augustine, D. X., Yaqub, M. K., Szmigielski, C. A., Lima, E., Petersen, S. E., Becher, H. H., Noble, J. A., & Leeson, P. (2014) · Echocardiography · doi:10.1111/echo.12655 · Cited by 12
Kolus, A., Dubé, P.-A., Imbeau, D., Labib, R., & Dubeau, D. (2014) · Applied Ergonomics · doi:10.1016/j.apergo.2014.04.003 · Cited by 12
Ukawa, T., Takayanagi, T., Morimoto, H., Higashi, Y., Idei, N., Yoshizumi, M., & Tsuji, T. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0955-z · Cited by 12
Home and Office Blood Pressure Monitoring in Renal Transplant Recipients
Sberro‐Soussan, R., Rabant, M., Snanoudj, R., Zuber, J., Bererhi, L., Mamzer, M., Legendre, C. M., & Thervet, É. (2012) · Journal of Transplantation · doi:10.1155/2012/702316 · Cited by 12
Shindi, A. A. F., Pei-Chen, Z., Zou, Z., & Li, Y. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.01.062 · Cited by 12
Martín, M. L., Álvarez, F. J. V., González, R., Salvanés, F. J. R., Cobo, P. C., & García, M. A. H. (2011) · Rehabilitación · doi:10.1016/j.rh.2011.03.008 · Cited by 12
Harmon, E. Y., Fronhofer, V., Keller, R. S., Feustel, P. J., Brosnan, M. J., von der Thüsen, J. H., Loegering, D. J., & Lennartz, M. R. (2012) · PLoS ONE · doi:10.1371/journal.pone.0029944 · Cited by 13
Reliability of the Dynamic Gait Index (Finnish version) in individuals with neurological disorders
Tuomela, J., Paltamaa, J., & HÄKKINEN, A. H. (2012) · Disability and Rehabilitation · doi:10.3109/09638288.2012.660602 · Cited by 12
Ye, S., Wang, Y. C., Shimbo, D., Newman, J. D., Levitan, E. B., & Muntner, P. (2013) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2013.12.006 · Cited by 15
Sibbald, C. J., Seto, W., Taylor, T. L., Saunders, E. F., Doyle, J., & Dupuis, L. L. (2008) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e318180c662 · Cited by 12
Validity of Oxycon Mobile in measuring inspiratory capacity in healthy subjects
Hannink, J., Lahaije, A., Verberkt, C. A., Dekhuijzen, R. P. N., van Helvoort, H. A., & Heijdra, Y. F. (2010) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2010.00924.x · Cited by 16
Cheng, W., Zeng, M., Arellano, C., Mafori, W., Goldin, J. G., Krishnam, M. S., & Ruehm, S. G. (2010) · British Journal of Radiology · doi:10.1259/bjr/82257160 · Cited by 12
Silvennoinen, M., Rantalainen, T., & Kainulainen, H. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.06.027 · Cited by 12
Guo, W., Liu, X., Gao, Z., Pirbhulal, S., Huang, W., Lin, W.-H., Zhang, H., Tan, N., & Zhang, Y. (2015) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0048-y · Cited by 12
Turner, G., Richardson, A. J., Maxwell, N. S., & Pringle, J. S. M. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/12/n41 · Cited by 9
Comparison of three point-of-care blood glucose meters for use in adult and juvenile alpacas
Tennent‐Brown, B. S., Koenig, A., Williamson, L. H., & Boston, R. C. (2011) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.239.3.380 · Cited by 13
Chaplin, J. E., Hallman, M., Nilsson, N.-Ö., & Lindblad, B. (2011) · Acta Paediatrica · doi:10.1111/j.1651-2227.2011.02581.x · Cited by 12
Hill, R. F., Tofts, P. S., & Baldock, C. (2010) · Radiation Measurements · doi:10.1016/j.radmeas.2010.02.003 · Cited by 12
Weiss, P. F., Klink, A. J., Faerber, J., & Feudtner, C. (2013) · Pediatric Rheumatology · doi:10.1186/1546-0096-11-43 · Cited by 16
Statistical methods in epidemiology. VI. Correlation and regression: the same or different?
Rigby, A. S. (2000) · Disability and Rehabilitation · doi:10.1080/09638280050207857 · Cited by 12
Evaluation of the In2it® analyzer for HbA1c determination
Martin, M., Leroy, N., Sulmont, V., & Gillery, P. (2010) · Diabetes & Metabolism · doi:10.1016/j.diabet.2009.11.005 · Cited by 12
Force Capacity of Back Extensor Muscles in Healthy Males: Effects of Age and Recovery Time
Kurz, E., Anders, C., Walther, M., Schenk, P., & Scholle, H. (2014) · Journal of Applied Biomechanics · doi:10.1123/jab.2013-0308 · Cited by 12
Manual compression of the abdomen to assess expiratory flow limitation during mechanical ventilation
Lemyze, M., Favory, R., Alves, I., Perez, T., & Mathieu, D. (2011) · Journal of Critical Care · doi:10.1016/j.jcrc.2011.05.011 · Cited by 12
Öztuna, D., Elhan, A. H., Küçükdeveci, A. A., Kutlay, Ş., & Tennant, A. (2010) · Disability and Rehabilitation · doi:10.3109/09638281003777572 · Cited by 12
Aortic pressure wave reconstruction during exercise is improved by adaptive filtering: a pilot study
Stok, W. J., Westerhof, B. E., Guelen, I., & Karemaker, J. M. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0795-2 · Cited by 12
The Mandarin Chinese version of the childhood autism spectrum test (CAST): Test–retest reliability
Sun, X., Allison, C. L., Auyeung, B., Matthews, F. E., Baron‐Cohen, S., & Brayne, C. (2013) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2013.05.042 · Cited by 12
Andersson, A. K., Kron, J., Castrén, M. K., Athlin, Å. M., Hök, B., & Wiklund, L. (2015) · Scandinavian Journal of Trauma Resuscitation and Emergency Medicine · doi:10.1186/s13049-014-0082-y · Cited by 12
Body-Density Measurement in Children: The BOD POD Versus Hydrodensitometry
Holmes, J. C., Gibson, A. L., Cremades, J. G., & Mier, C. M. (2011) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.21.3.240 · Cited by 12
Hsu, C.-C., Chang, Y.-H., Lin, W.-C., Tang, S.-W., Wang, P.-W., Huang, Y.-C., & Chiu, N.-T. (2014) · TheScientificWorldJournal · doi:10.1155/2014/879497 · Cited by 12
Can ultrasound be used to estimate bone mineral density in children with growth problems?
Khan, K., Sarafoglou, K., Somani, A., Frohnert, B. I., & Miller, B. S. (2013) · Acta Paediatrica · doi:10.1111/apa.12314 · Cited by 12
Katsoulidou, A., Rokka, C., Issaris, C., Haida, C., Tzannis, K., Sypsa, V., Detsika, M. G., Paraskevis, D. N., & Hatzakis, A. E. (2011) · Virology Journal · doi:10.1186/1743-422x-8-10 · Cited by 15
Comparison of patient-reported visual outcome methods to quantify the perceptual effects of defocus
Kollbaum, P. S., Jansen, M. E., & Rickert, M. E. (2012) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2012.05.001 · Cited by 13
Browning, D. J. (2010) · PubMed Central · Cited by 12
Measurement Consistency from Magnetic Resonance Images
Chung, D., Chung, M. K., Durtschi, R. B., Gentry, L. R., & Vorperian, H. K. (2008) · Academic Radiology · doi:10.1016/j.acra.2008.04.020 · Cited by 12
Tse, H., Cheung, B. M. Y., Ng, W., Chan, J. K. F., Devereux, R. B., & Lau, C. (2003) · Journal of Cardiac Failure · doi:10.1054/jcaf.2003.12 · Cited by 12
da Silva, C., Pedro, F., Deister, L., Sahlén, A., Manouras, A., & Shahgaldi, K. (2012) · Echocardiography · doi:10.1111/j.1540-8175.2012.01695.x · Cited by 13
McGhie, J. S., Menting, M. E., Vletter, W. B., Frowijn, R., Roos‐Hesselink, J. W., Soliman, O. I. I., van der Zwaan, H. B., Geleijnse, M. L., & van den Bosch, A. E. (2015) · Echocardiography · doi:10.1111/echo.13102 · Cited by 12
Muckelbauer, R., Libuda, L., & Kersting, M. (2009) · Public Health Nutrition · doi:10.1017/s1368980009990759 · Cited by 12
Mathis, J. C., & Campbell, V. L. (2015) · American Journal of Veterinary Research · doi:10.2460/ajvr.76.7.632 · Cited by 14
Towards harmonization of forest deposition collectors - case study of comparing collector designs
Žlindra, D., Eler, K., Clarke, N., & Simončić, P. (2011) · iForest - Biogeosciences and Forestry · doi:10.3832/ifor0586-004 · Cited by 12
Lee, S., Jeon, G., & Lee, G. (2013) · Sensors · doi:10.3390/s131013609 · Cited by 12
Fiber analysis: Evaluation of screen printing fabric filters bags by three statistical approaches
Marichal, M. D. J., Trujillo, A. I., Cadenazzi, M., & Arias, G. (2011) · Animal Feed Science and Technology · doi:10.1016/j.anifeedsci.2011.06.005 · Cited by 12
Juusela, M., Poussa, T. A., Kotaniemi, J., Lundbäck, B., & Sovijärvi, A. R. A. (2008) · International Journal of Circumpolar Health · doi:10.3402/ijch.v67i4.18343 · Cited by 12
Petterwood, J., Dowsey, M. M., Rodda, D., & Choong, P. (2014) · Frontiers in Surgery · doi:10.3389/fsurg.2014.00035 · Cited by 12
Onxley, J. D., Yoo, D. S., Muradyan, N., MacFall, J. R., Brizel, D. M., & Craciunescu, O. I. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.03.006 · Cited by 12
Doughty, M. J., Jalota, V., Bennett, E., Naase, T., & Oblak, E. (2005) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2004.00261.x · Cited by 12
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.