STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 28,101–28,200 of 47,868
Preventive effects of the heparin-coated stent on restenosis in the porcine model
Ahn, Y. K., Jeong, M. H., Kim, J. W., Kim, S. H., Cho, J. H., Cho, J. G., Park, C. S., Juhng, S. W., Park, J. C., & Kang, J. C. (1999) · Catheterization and Cardiovascular Interventions · doi:10.1002/(sici)1522-726x(199911)48:3<275::aid-ccd8>3.0.co;2-m · Cited by 76
Yi, G., Gallagher, M. M., Yap, Y. G., Guo, X., HARRISON, R., MCDONALD, J. T., Camm, A. J., & Malík, M. (2000) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2000.tb00796.x · Cited by 12
Taylor, L., Ashley, K., Jones, R. L., & Deddens, J. A. (2004) · American Journal of Industrial Medicine · doi:10.1002/ajim.20096 · Cited by 12
Electromyographic Power Spectral Analysis of the Paraspinal Muscles
Ali, M., Bandpey, M., & Watson, M. J. (2001) · Physiotherapy · doi:10.1016/s0031-9406(05)60694-3 · Cited by 12
Dilatation of the Bile Duct in Patients after Cholecystectomy: A Retrospective Study
Landry, D., Tang, A., Murphy-Lavallée, J., Lepanto, L., Billiard, J.-S., Olivié, D., & Sylvestre, M. (2013) · Canadian Association of Radiologists Journal · doi:10.1016/j.carj.2012.09.004 · Cited by 12
Aydin, F. A., Tezcan, G., Güngör, Ö., Cengiz, A. K., Hazar, V., Akman, S., Güven, A. G., Yeşilipek, A., Akbas, H. S., & Güngör, F. (2010) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e328334fc6f · Cited by 12
Accuracy of three novel predictive methods for measurements of fat mass in healthy older subjects
Lara, J., Siervo, M., Bertoli, S., Mathers, J. C., Battezzati, A., Ferraris, C., & Tagliabue, A. (2013) · Aging Clinical and Experimental Research · doi:10.1007/s40520-013-0169-8 · Cited by 15
Increasing vigilance on the medical/surgical floor to improve patient safety
Jacobs, J. L., Apatov, N. M., & Glei, M. (2007) · Journal of Advanced Nursing · doi:10.1111/j.1365-2648.2006.04161.x · Cited by 12
Woods, C. B., & Nelson, N. M. (2014) · Journal of Transport & Health · doi:10.1016/j.jth.2014.07.001 · Cited by 12
Massart, C., Gibassier, J., Oger, J. J.-F., Page, E. L., & Edan, G. (2006) · Clinica Chimica Acta · doi:10.1016/j.cca.2006.09.021 · Cited by 12
van der Lee, I., van Es, H. W., Noordmans, H. J., van den Bosch, J. M. M., & Zanen, P. (2005) · Respiration · doi:10.1159/000088711 · Cited by 12
Lamb, K., Eaves, S. J., & Hartshorn, J. E. O. (2004) · Journal of Sports Sciences · doi:10.1080/02640410310001641485 · Cited by 12
Maximal Accumulated Oxygen Deficit in Patients with Chronic Heart Failure
Mezzani, A., Corrà, U., Sassi, B. H., Colombo, R., Giordano, A., & Giannuzzi, P. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000191432.87926.41 · Cited by 12
The reliability of frontal facial photographs to assess changes in nasolabial soft tissues
Muradin, M. S. M., Rosenberg, A. J. W. P., van der Bilt, A., Stoelinga, P. J. W., & Koole, R. (2007) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2007.05.010 · Cited by 12
Kalache, K. D., Nishina, H., Ojutiku, D., & Hanson, M. A. (2001) · Fetal Diagnosis and Therapy · doi:10.1159/000053938 · Cited by 12
The effect of posture change on the position of the skin marks for the transverse horizontal axis
O'Boyle, K. H., Gallagher, F. D., O’Sullivan, M., & McDevitt, W. E. (1996) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(96)90461-8 · Cited by 12
Hofhuis, J. G. M., Dijkgraaf, M. G. W., Hovingh, A., Braam, R. L., van de Braak, L., Spronk, P. E., & Rommes, J. H. (2011) · Critical Care · doi:10.1186/cc10447 · Cited by 12
Ksiezycki-Ostoya, B. K., McCollum, A. G. H., & Becker, P. J. (2009) · Seminars in Orthodontics · doi:10.1053/j.sodo.2009.03.005 · Cited by 12
Total Carbon Dioxide Measured by the Vitros Enzymatic Method
Frezzotti, A., Gambini, A. M. M., Coppa, G., & Sio, G. D. (1998) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1998.008 · Cited by 12
Zinellu, A., Sotgia, S., Caddeo, S., Deiana, L., & Carru, C. (2005) · Journal of Separation Science · doi:10.1002/jssc.200500109 · Cited by 12
Hirano, K., Maruyama, S., Mino, Y., Naito, T., & Kawakami, J. (2011) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2010.12.020 · Cited by 12
Urinary iodide concentration in hyperthyroid cats
Wakeling, J., Elliott, J., Petrie, A., Brodbelt, D. C., & Syme, H. M. (2009) · American Journal of Veterinary Research · doi:10.2460/ajvr.70.6.741 · Cited by 15
Evaluation of analytical performance of the Pathfast® cardiac troponin I
Serio, F. D., Caputo, M., Zaninotto, M., Ottomano, C., & Plebani, M. (2009) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2009.182 · Cited by 12
Sagittal alignment of the lower extremity while standing in female
Sugama, R., Minoda, Y., Kobayashi, A., Iwaki, H., Ikebuchi, M., Hashimoto, Y., Takaoka, K., & Nakamura, H. (2010) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-010-1137-x · Cited by 12
Predicted and measured resting energy expenditure in healthy young women
Scalfi, L., Coltorti, A., Sapio, C., Biase, G. D., Borrelli, R., & Contaldo, F. (1993) · Clinical Nutrition · doi:10.1016/0261-5614(93)90137-s · Cited by 12
Repeatability of near visual acuity measurement at high and low contrast
Lam, A. K. C., Tong, C., Tse, J. S.-H., & Wong, M. Y. (2008) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2007.00235.x · Cited by 13
Comparison of intracranial pressure measured in the cerebral cortex and the cerebellum of the rat
Rooker, S., Visscher, G. D., Deuren, B. V., Borgers, Μ., Jorens, P. G., Reneman, R. S., van Rossem, K., & Verlooy, J. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00183-8 · Cited by 12
Intra‐ and interobserver repeatability of femur length measurement in early pregnancy
Rosati, P., Bartolozzi, F., & Guariglia, L. (2004) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.958 · Cited by 12
Griffanti, L., Baglio, F., Preti, M. G., Cecconi, P., Rovaris, M., Baselli, G., & Laganà, M. M. (2011) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.06.003 · Cited by 12
Flow-Through Analysis of Glutathione in Human Erythrocytes with an Amperometric Biosensor
Compagnone, D., Federici, G., Scarciglia, L., & Palleschi, G. (1994) · Analytical Letters · doi:10.1080/00032719408006343 · Cited by 12
Who uses contrast sensitivity in optometric practice?
Latham, K. (1998) · Ophthalmic and Physiological Optics · doi:10.1016/s0275-5408(97)00103-8 · Cited by 12
Kjøller‐Hansen, L., Steffensen, R., & Grande, P. (2004) · American Heart Journal · doi:10.1016/j.ahj.2004.04.004 · Cited by 12
Comparison of Calcitonin Determinations by Polyclonal and Monoclonal IRMAs
Tommasi, M., & Raspanti, S. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.083733 · Cited by 12
Agha, H. M., El-Beshlawy, A. M., Hamdy, M. M., Sobeih, A., Zahrae, F. E., Satar, I. A. E., AbdelMassih, A. F., Said, F., Aziz, O. A. E., Eltagui, M. H., et al. (2014) · Pediatric Cardiology · doi:10.1007/s00246-014-1035-y · Cited by 12
Bott, L., Béghin, L., Gondon, E., Hankard, R., Pierrat, V., & Gottrand, F. (2006) · Clinical Nutrition · doi:10.1016/j.clnu.2006.02.001 · Cited by 13
Dazzani, F., Micati, M., Caraceni, P., Drago, G. M., Domenicali, M., Pacilli, P., Tomassetti, V., Gelonesi, E., Trevisani, F., & Bernardi, M. (2005) · Digestive and Liver Disease · doi:10.1016/j.dld.2005.05.008 · Cited by 16
Smoking exposure in pregnancy: use of salivary cotinine in monitoring
Delpisheh, A., Topping, J. H., Reyad, M., Tang, A.-W., & Brabin, B. J. (2007) · British Journal of Midwifery · doi:10.12968/bjom.2007.15.4.23385 · Cited by 12
Queen's College Step Test as an Alternative of Harvard Step Test in Young Indian Women
Bandyopadhyay, A. (2008) · International Journal of Sport and Health Science · doi:10.5432/ijshs.6.15 · Cited by 12
Infraclavicular sensor site: A new promising site for transcutaneous capnography
Chhajed, P. N., Chaudhari, P., Tulasigeri, C., Kate, A. H., Kesarwani, R., Miedinger, D., Leuppi, J. D., & Baty, F. (2012) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2012.671490 · Cited by 12
Rose, M. H., Bandholm, T., & Jensen, B. R. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.09.025 · Cited by 12
Classification of transcranial Doppler signals using their chaotic invariant measures
Öztürk, A., & Arslan, A. (2007) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2007.02.004 · Cited by 12
Mostamand, J., Bader, D. L., & Hudson, Z. (2012) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2011.03.003 · Cited by 12
Influence of freeze-drying on the clotting properties of fibrinogen in plasma
Jensen, T., Halvorsen, S., Godal, H. C., & Skjønsberg, O. H. (2002) · Thrombosis Research · doi:10.1016/s0049-3848(02)00057-9 · Cited by 12
Comparison of coronary plaque subtypes in male and female patients using 320-row MDCTA
Khosa, F., Khan, A. N., Nasir, K., Bedayat, A., Malik, Z., Jon, A. F., Cheema, A. R., Clouse, M. E., & Welty, F. K. (2012) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2012.11.033 · Cited by 13
Transcutaneous PCO2 monitoring in infants hospitalized with viral bronchiolitis
Gal, S., Riskin, A., Chistyakov, I., Shifman, N., Srugo, I., & Kugelman, A. (2014) · European Journal of Pediatrics · doi:10.1007/s00431-014-2407-2 · Cited by 12
0.1%/0.2% commercial chlorhexidine solutions as subgingival irrigants in chronic periodontitis
Asari, A. M., Newman, H. N., Wilson, M., & Bulman, J. S. (1996) · Journal Of Clinical Periodontology · doi:10.1111/j.1600-051x.1996.tb00552.x · Cited by 12
Greil, W., & Steller, B. (1992) · Psychiatry Research · doi:10.1016/0165-1781(92)90071-a · Cited by 12
Impact of nuchal cord on measurement of fetal nuchal translucency thickness
Scheier, M., Egle, D., Himmel, I., Ramoni, A., Viertl, S., Huter, O., & Marth, C. (2007) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.4064 · Cited by 13
Comparison between RapidTEG® and conventional thromboelastography in cardiac surgery patients
Thai, J., Reynolds, E. J., Natalia, N., Cornelissen, C., Lemmens, H. J. M., Hill, C. C., & van der Starre, P. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer054 · Cited by 12
Grading of Aortic Valve Stenosis at 64-Slice Spiral Computed Tomography
Lembcke, A. E., Woinke, M., Borges, A. C., Dohmen, P. M., Lachnitt, A., Westermann, Y., Geigenmueller, A., Hermann, K., Butler, C., Thiele, H., et al. (2009) · Investigative Radiology · doi:10.1097/rli.0b013e3181a64d76 · Cited by 12
A comparison of retrospective versus contemporaneous nausea scores with patient‐controlled analgesia
McIndoe, A. K., WARWICK, P., & O'Connor, M. (1996) · Anaesthesia · doi:10.1111/j.1365-2044.1996.tb07742.x · Cited by 12
Mussap, M., Ponchia, S., Zaninotto, M., Varagnolo, M., & Plebani, M. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2005.10.016 · Cited by 12
Saur, J., Trinkmann, F., Doesch, C., Weissmann, J., Hamm, K., Schoenberg, S. O., Borggrefe, M. M., Haghi, D., & Kaden, J. J. (2010) · Cardiology · doi:10.1159/000288712 · Cited by 12
Fiducial approach for assessing agreement between two instruments
Wang, C. M., & Iyer, H. K. (2008) · Metrologia · doi:10.1088/0026-1394/45/4/006 · Cited by 12
Reproducibility of Morning Blood Pressure Surge and Its Relation to Blood Pressure Reactivity
Wang, M.-Y., Huang, C.-J., Chang, N.-C., & Tsai, P. (2007) · Clinical and Experimental Hypertension · doi:10.1080/10641960701578345 · Cited by 12
Adaptive network based on fuzzy inference system for equilibrated urea concentration prediction
Azar, A. T. (2013) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2013.05.012 · Cited by 12
Ryeng, K. A., Larsen, S. E., Ranheim, B., Albertsen, G., & Arnemo, J. M. (2001) · American Journal of Veterinary Research · doi:10.2460/ajvr.2001.62.406 · Cited by 12
Keller, U., Grabenbauer, G. G., Kuechler, A., Sauer, R., & Distel, L. V. (2004) · International Journal of Radiation Biology · doi:10.1080/09553000410001724568 · Cited by 12
Measurement of cardiac output: Comparison of four different methods
Kothari, N., Hegde, A., & Mandke, N. V. (2003) · Indian Journal of Thoracic and Cardiovascular Surgery · doi:10.1007/s12055-003-0011-6 · Cited by 12
Simon, R., Desebbe, O., Hénaine, R., Bastien, O. H., Lehot, J.-J., & Cannesson, M. P. (2009) · Annales Françaises d Anesthésie et de Réanimation · doi:10.1016/j.annfar.2009.04.010 · Cited by 12
Zahariev, A., Bergouignan, A., Caloin, M., Normand, S., Gauquelin‐Koch, G., Gharib, C., & Blanc, S. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0021-8 · Cited by 12
Non-invasive Intracranial Pressure estimation using Support Vector Machine
Chacón, M., Pardo, C., Puppo, C., Curilem, M., & Landerretche, J. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627816 · Cited by 12
Early Pregnancy Placental Bed and Fetal Vascular Volume Measurements Using 3-D Virtual Reality
Reus, A. D., der Aa, J. K.-V., Rifouna, M. S., Koning, A. H. J., Exalto, N., van der Spek, P. J., & Steegers, E. A. P. (2014) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2014.02.022 · Cited by 14
Nishiyama, T., Kohno, Y., & Koishi, K. (2011) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-011-9311-3 · Cited by 12
New Methodological Approach to Improve Reproducibility of Brachial Artery Flow‐Mediated Dilatation
Kanahara, M., Harada, H., Katoh, A., & Ikeda, H. (2013) · Echocardiography · doi:10.1111/echo.12307 · Cited by 12
Winz, O., Meyer, P. T., Knollmann, D., Lipke, C. S. A., Kühl, H. P., Oelve, C., & Schaefer, W. M. (2008) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2008.00840.x · Cited by 12
Donma, M. M., Donma, O., & Sönmez, S. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.07.017 · Cited by 14
Jones, B. J., & Twomey, P. J. (2008) · Journal of Clinical Pathology · doi:10.1136/jcp.2007.050872 · Cited by 12
Repeatability of Peak Oxygen Uptake in Children Who Are Healthy
Johnston, K., JENKINS, S. C., & Stick, S. M. (2005) · Pediatric Physical Therapy · doi:10.1097/01.pep.0000154340.43505.91 · Cited by 12
Bailey, J. M., Shanewise, J. S., Kikura, M., & Sharma, S. (1995) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(05)80227-7 · Cited by 12
Brautaset, R., Birkeldh, U., Rosén, R. M., Ramsay, M. W., & Nilsson, M. (2014) · European Journal of Ophthalmology · doi:10.5301/ejo.5000437 · Cited by 12
Gobbo, L. A., Cyrino, E. S., Petróski, E. L., Cardoso, J. R., Carvalho, F. O., Romanzini, M., & Avelar, A. (2008) · Revista Brasileira de Medicina do Esporte · doi:10.1590/s1517-86922008000400011 · Cited by 13
Nolan, B. G., Ross, L. A., Vaccaro, D. E., Groman, E. V., & Reinhardt, C. P. (2009) · American Journal of Veterinary Research · doi:10.2460/ajvr.70.4.547 · Cited by 12
Comparability of infant abdominal skin and axillary temperatures
Thomas, K. A. (2003) · Newborn and Infant Nursing Reviews · doi:10.1053/s1527-3369(03)00123-5 · Cited by 12
Yun, J. Y., Park, S., Cho, D.-S., Jeung, H.-J., Lee, S.-A., & Seo, S. J. (2011) · Korean Journal of Anesthesiology · doi:10.4097/kjae.2011.61.4.281 · Cited by 12
Reliability of isometric subtalar pronator and supinator strength testing
Hagen, M., Lahner, M., Winhuysen, M., & Maiwald, C. (2015) · Journal of Foot and Ankle Research · doi:10.1186/s13047-015-0075-8 · Cited by 13
Do bifocals reduce accommodative amplitude in convergence excess esotropia?
Fresina, M., Schiavi, C., & Campos, E. C. (2010) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-010-1418-6 · Cited by 12
A NOVEL NONINVASIVE IMPEDANCE-BASED TECHNIQUE FOR CENTRAL VENOUS PRESSURE MEASUREMENT
Ward, K. R., Tiba, M. H., Draucker, G. T., Proffitt, E. K., Barbee, R. W., Gunnerson, K. J., Reynolds, P. S., & Spiess, B. D. (2010) · Shock · doi:10.1097/shk.0b013e3181ab9b9b · Cited by 12
Ambulatory blood pressure in heart failure
Jamieson, M. J., & Jamieson, C. (2001) · European Journal of Clinical Investigation · doi:10.1046/j.1365-2362.2001.0310s2018.x · Cited by 12
Sanchez, O. A., Louie, E. A., Copenhaver, E. A., & Damon, B. M. (2009) · NMR in Biomedicine · doi:10.1002/nbm.1388 · Cited by 12
Application of bioreactance for cardiac output assessment during exercise in healthy individuals
Elliott, A. D., Hull, J. H., Nunan, D., Jakovljević, D. G., Brodie, D. A., & Ansley, L. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1440-8 · Cited by 12
Høyer, E., Opheim, A. I., Strand, L. I., & Moe‐Nilssen, R. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.03.001 · Cited by 17
Qayed, M. D., Thompson, A., Applegate, K., Haight, A. E., Rogatko, A., Chiang, K., & Horan, J. (2010) · Pediatric Blood & Cancer · doi:10.1002/pbc.22506 · Cited by 12
Hozumi, T., Yoshida, K., Abe, Y., Kanda, R., Akasaka, T., Takagi, T., Yagi, T., Ogata, Y., & Yoshikawa, J. (1998) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(98)70043-4 · Cited by 12
Brostrøm, S., Jennum, P., & Lose, G. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00199-8 · Cited by 12
Suzukamo, Y., Noguchi, H., Takahashi, N., Shimatsu, A., Chihara, K., Green, J., & Fukuhara, S. (2006) · Growth Hormone & IGF Research · doi:10.1016/j.ghir.2006.09.002 · Cited by 17
Katzberg, R. W., Buonocore, M. H., Low, R. K., Hu, B. R., Jain, K. A., del Castillo, M. S., Troxel, S. A., & Nguyen, M. M. (2009) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.270 · Cited by 12
Can dimercaptosuccinic acid renal scintigraphy be used to assess global renal function?
Durand, E., & Prigent, A. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050569 · Cited by 12
Appearance of the levator ani muscle in pregnancy as assessed by 3-D MRI
Boreham, M. K., Zaretsky, M. V., Corton, M. M., Alexander, J. M., McIntire, D. D., & Twickler, D. M. (2005) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2005.07.094 · Cited by 12
Total body water in children with cystic fibrosis using bioelectrical impedance
Puiman, P. J., Francis, P. W., Buntain, H. M., Wainwright, C. E., Masters, I. B., & Davies, P. S. W. (2004) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2004.06.007 · Cited by 13
Marwah, S. A., Shah, H., Chauhan, K., Trivedi, A., & Haridas, N. (2013) · Indian Journal of Clinical Biochemistry · doi:10.1007/s12291-013-0329-9 · Cited by 12
Viegi, G., SIMONI, M., Pistelli, F., Englert, N., Salonen, R. M., Niepsuj, G., Hałuszka, J., & ROEMER, W. (2000) · Respiratory Medicine · doi:10.1053/rmed.1999.0672 · Cited by 12
Seo, Y., Wang, Z., Ball, G., & Rollins, N. K. (2012) · Pediatric Radiology · doi:10.1007/s00247-012-2527-7 · Cited by 12
Differences in Plethysmographic Lung Volumes
Williams, J. H., & Bencowitz, H. Z. (1989) · CHEST Journal · doi:10.1378/chest.95.1.117 · Cited by 12
Otto, J., Kämmer, D., Biermann, A., Jansen, M., Dembinski, R., Schumpelick, V., & Schachtrupp, A. (2008) · BMC Surgery · doi:10.1186/1471-2482-8-18 · Cited by 12
Schachar, R. A., & Fygenson, D. K. (2006) · British Journal of Ophthalmology · doi:10.1136/bjo.2006.094888 · Cited by 12
Evaluation of semi-automatic arterial stenosis quantification
Hoyos, M. H., Serfaty, J., Maghiar, A., Desbleds‐Mansard, C., Orkisz, M., Magnin, I. E., & Douek, P. (2006) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-006-0049-1 · Cited by 12
The importance of accurate anatomic assessment for the volumetric analysis of the amygdala
Bonilha, L., Kobayashi, E., Cendes, F., & Li, L. M. (2005) · Brazilian Journal of Medical and Biological Research · doi:10.1590/s0100-879x2005000300012 · Cited by 15
The Repeatability of Diagnostic Tests and Surveys in Dry Eye
Nichols, K. K., & Zadnik, K. (2002) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-0717-8_165 · Cited by 12
Resch, H., Deák, G. G., Pereira, I., & Vass, C. (2012) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2012.02385.x · Cited by 12
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.