STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 27,901–28,000 of 47,868
Dimeski, G., Badrick, T. C., Flatman, R., & Ormiston, B. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.039248 · Cited by 12
Validation of the howRu and howRwe questionnaires at the individual patient level
Hendriks, S. H., Rutgers, J., van Dijk, P. R., Groenier, K. H., Bilo, H. J. G., Kleefstra, N., Kocks, J. W. H., van Hateren, K. J. J., & Blanker, M. H. (2015) · BMC Health Services Research · doi:10.1186/s12913-015-1093-8 · Cited by 12
National perinatal audit, a feasible initiative for the Netherlands!? A validation study
van Diem, M. T., Reu, P. A. O. M. D., Eskes, M., BROUWERS, H. A. A., Holleboom, C. A. G., Slagter‐Roukema, T., & Merkus, H. M. W. M. (2010) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.3109/00016349.2010.500468 · Cited by 12
Kneidinger, N., Warszawska, J. M., Schenk, P., Fuhrmann, V., Bojic, A., Hirschl, A. M., Herkner, H., Madl, C., & Makristathis, A. (2013) · Critical Care · doi:10.1186/cc12814 · Cited by 12
Reproducibility of and sex differences in common orthopaedic ankle and foot tests in runners
van der Worp, M. P., de Wijer, A., Staal, J. B., & der Sanden, M. W. G. N. (2014) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-15-171 · Cited by 21
Earlobe arterialized capillary blood gas analysis in the intensive care unit: a pilot study
Vaquer, S., Masip, J., Gili, G., Gomà, G., Oliva, J. C., Frechette, A., Evetts, S. E., Russomano, T., & Artigas, A. (2014) · Annals of Intensive Care · doi:10.1186/2110-5820-4-11 · Cited by 12
Lee, T. H., Lee, J. S., Hong, S. J., Lee, J. S., Jeon, S. R., Kim, W. J., Kim, H. G., Cho, J. Y., Kim, J. O., Cho, J.-H., et al. (2014) · The Turkish Journal of Gastroenterology · doi:10.5152/tjg.2014.8021 · Cited by 12
Asymmetric Motion Distribution Between Components of a Mobile-Core Lumbar Disc Prosthesis
Patwardhan, A. G., Havey, R. M., Wharton, N. D., Tsitsopoulos, P. P., Newman, P., Carandang, G., & Voronov, L. I. (2012) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.j.00638 · Cited by 12
Reproducibility of Apparent Diffusion Coefficient Measurements in Malignant Breast Masses
Jang, M., Kim, S. M., Yun, B. L., Ahn, H. S., Kim, S. Y., Kang, E., & Kim, S. (2015) · Journal of Korean Medical Science · doi:10.3346/jkms.2015.30.11.1689 · Cited by 12
Comparison of anterior and posterior topographic analysis between 3 imaging systems
Mi, H. F., Tan, N., Ang, M., Htoon, H. M., & Mehta, J. S. (2015) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2015.05.039 · Cited by 12
Validating self-reported food expenditures against food store and eating-out receipts
Tang, W., Aggarwal, A., Liu, Z., Acheson, M. A., Rehm, C. D., Moudon, A. V., & Drewnowski, A. (2015) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2015.166 · Cited by 12
Diez‐Aguilar, M., Martínez-García, L., Cantón, R., & Morosini, M. I. (2015) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.02237-15 · Cited by 12
Repeatability Using Automatic Tracing with Canon OCT- HS100 and Zeiss Cirrus HD-OCT 5000
Brautaset, R., Birkeldh, U., Alstig, P. F., Wikén, P., & Nilsson, M. (2016) · PLoS ONE · doi:10.1371/journal.pone.0149138 · Cited by 12
Comparison of frequency doubling and flicker defined form perimetry in early glaucoma
Horn, F. K., Scharch, V., Mardin, C. Y., Lämmer, R., & Kremers, J. (2016) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-016-3286-1 · Cited by 12
Tustin, K., Gimeno, H., Morton, E., & Marsden, J. F. (2016) · Developmental Medicine & Child Neurology · doi:10.1111/dmcn.13081 · Cited by 12
Midorikawa, T., Ohta, M., Hikihara, Y., Torii, S., & Sakamoto, S. (2015) · British Journal Of Nutrition · doi:10.1017/s0007114515002585 · Cited by 12
on behalf of the BOOST-II UK Collaborative Group, Moreton, R., Fleck, B. W., Fielder, A. R., Williams, C., Butler, L., Wilson, C. M., Cocker, K. D., Juszczak, E., King, A., et al. (2016) · Eye · doi:10.1038/eye.2015.280 · Cited by 12
Ochocińska, A., Śnitko, R., Czekuć-Kryśkiewicz, E., Kępka, A., Szalecki, M., & Janas, R. M. (2016) · Journal of Immunoassay and Immunochemistry · doi:10.1080/15321819.2015.1126601 · Cited by 13
Shen, M., Xu, Z. Y., Yang, C., Leng, L., Liu, J., Chen, Q., Wang, J., & Lü, F. (2014) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000000017 · Cited by 13
Cheng, J., Salam, T., Russell, P. J., Garway‐Heath, D. F., & Kotecha, A. (2013) · Journal of Glaucoma · doi:10.1097/ijg.0b013e31825c0f9e · Cited by 12
Chao, C., Golebiowski, B., Stapleton, F. J., & Richdale, K. (2015) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000000182 · Cited by 12
Evaluation of renal function in elderly patients
Maioli, C., Cozzolino, M. G., Gallieni, M. A., Sole, A. D., Tagliabue, L., Strinchini, A., Gaito, S., Lecchi, M., Cusi, D., & Lucignani, G. (2013) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000000066 · Cited by 12
Association between depression severity and cardiac autonomic modulation
Tolentino, J. C., & Schmidt, S. L. (2016) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2016.03.125 · Cited by 13
Clinical Evaluation of Accuracy of Horizontal Meridian Limbal Marking
Igarashi, A., Kamiya, K., & Shimizu, K. (2013) · Optometry and Vision Science · doi:10.1097/opx.0b013e3182936590 · Cited by 12
Kar, J., Cupps, B. P., Zhong, X., Koerner, D. J., Kulshrestha, K., Neudecker, S., Bell, J. M., Craddock, H., & Pasque, M. K. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25239 · Cited by 13
Awatani, T., Mori, S., Shinohara, J., Koshiba, H., Nariai, M., Tatsumi, Y., Nagata, A., & Morikita, I. (2016) · Journal of Physical Therapy Science · doi:10.1589/jpts.28.936 · Cited by 12
Cirrus HD‐OCT Short‐Term Repeatability of Clinical Retinal Nerve Fiber Layer Measurements
Wong, E. P. Y., Yoshioka, N., Kalloniatis, M., & Zangerl, B. (2014) · Optometry and Vision Science · doi:10.1097/opx.0000000000000452 · Cited by 12
Comparing cardiac output monitors and defining agreement: A systematic review and meta-analysis
Crossingham, I. R., Nethercott, D. R., & Columb, M. O. (2016) · Journal of the Intensive Care Society · doi:10.1177/1751143716644457 · Cited by 12
Pien, G. W., Keenan, B. T., Marcus, C. L., Staley, B. A., Ratcliffe, S. J., JACKSON, N. J., Wieland, W., Sun, Y., & Schwab, R. J. (2016) · SLEEP · doi:10.5665/sleep.5736 · Cited by 13
Kulcke, A., Feiner, J., Menn, I., Holmer, A., Hayoz, J., & Bickler, P. E. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001219 · Cited by 14
Harvey, C. E., Laster, L. L., & Shofer, F. S. (2012) · Journal of Veterinary Dentistry · doi:10.1177/089875641202900402 · Cited by 12
Performance of a New Binocular Wavefront Aberrometer Based on a Self-imaging Diffractive Sensor
Warden, L., Liu, Y., Binder, P. S., Dreher, A. W., & Sverdrup, L. H. (2008) · Journal of Refractive Surgery · doi:10.3928/1081597x-20080201-10 · Cited by 12
Conductivity: On-Line Monitoring of Dialysis Adequacy
Vecchio, L. D., Filippo, S. D., Andrulli, S., Manzoni, C., Corti, M., Barbisoni, F., & Locatelli, F. (1998) · The International Journal of Artificial Organs · doi:10.1177/039139889802100902 · Cited by 12
Sibling Sleep—What Can It Tell Us About Parental Sleep Reports in the Context of Autism?
Schwichtenberg, A. J., Hensle, T., Honaker, S. M., Miller, M. R., Ozonoff, S. J., & Anders, T. F. (2016) · Clinical Practice in Pediatric Psychology · doi:10.1037/cpp0000143 · Cited by 14
Laillou, A., Icard‐Vernière, C., Rochette, I., Picq, C., Berger, J., Sambath, P., & Mouquet‐Rivier, C. (2013) · Food and Nutrition Bulletin · doi:10.1177/15648265130342s114 · Cited by 12
Actigraphy of Wrist and Ankle for Measuring Sleep Duration in Altitude Travelers
Latshang, T. D., Mueller, D. J., Cascio, C. M. L., Stöwhas, A.-C., Stadelmann, K., Tesler, N., Achermann, P., Huber, R., Kohler, M., & Bloch, K. E. (2016) · High Altitude Medicine & Biology · doi:10.1089/ham.2016.0006 · Cited by 12
Maxwell, B. M., Brunell, M. K., Olsen, C. H., & Bentzel, D. E. (2016) · PubMed Central · Cited by 12
Ozone, S., Shaku, F., Sato, M., Takayashiki, A., Tsutsumi, M., & Maeno, T. (2016) · Family Practice · doi:10.1093/fampra/cmw053 · Cited by 12
Panissa, V. L. G., Júlio, U. F., França, V., Lira, F. S., Hofmann, P., Takito, M. Y., & Franchini, É. (2016) · PubMed Central · Cited by 20
Selmi, M. A., Elloumi, M., Hambli, M., Sellami, M., Yahmed, M. H., & Sassi, R. H. (2016) · Science & Sports · doi:10.1016/j.scispo.2016.05.001 · Cited by 12
Comparison of V̇o 2peak Performance on a Motorized vs. a Nonmotorized Treadmill
Morgan, A. L., Laurent, C. M., & Fullenkamp, A. M. (2015) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001273 · Cited by 14
Yoshida, M., Igawa, Y., Higashimura, S., Suzuki, M., Niimi, A., & Sanada, H. (2016) · Neurourology and Urodynamics · doi:10.1002/nau.23111 · Cited by 12
A Comparison of Iran and UK EQ-5D-3L Value Sets Based on Visual Analogue Scale
Kiadaliri, A. (2016) · International Journal of Health Policy and Management · doi:10.15171/ijhpm.2016.131 · Cited by 12
Milligan, G. S., House, J. R., & Tipton, M. (2017) · Work · doi:10.3233/wor-172487 · Cited by 12
Validation of the Intuitive Eating Scale in pregnancy
Paterson, H., Hay‐Smith, J., Treharne, G. J., Herbison, P., & Howarth, C. (2016) · Journal of Health Psychology · doi:10.1177/1359105316671186 · Cited by 14
Balcı, M. K., Arı, E., Vayvada, M., Saltürk, C., Aşıcıoğlu, E., Kahveci, G., Akbal, Ö. Y., & Kutlu, C. A. (2016) · Transplantation Proceedings · doi:10.1016/j.transproceed.2016.06.055 · Cited by 12
Hatay, G. H., Yıldırım, M., & Öztürk-Işık, E. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1591-9 · Cited by 13
Wong, H. M., Wen, Y. F., Jayaraman, J., Li, J., Sun, L., KING, N. M., & ROBERTS, G. J. (2016) · Heliyon · doi:10.1016/j.heliyon.2016.e00216 · Cited by 12
The validity of the Youth Physical Activity Questionnaire in 12–13-year-old Scottish adolescents
McCrorie, P., Perez, A., & Ellaway, A. (2017) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2016-000163 · Cited by 15
Croyal, M., Fall, F., Krempf, M., Thedrez, A., Ouguerram, K., Ferchaud‐Roucher, V., Aguesse, A., Billon‐Crossouard, S., Mata, P., Rodrigo Alonso, K., et al. (2017) · Journal of Chromatography B · doi:10.1016/j.jchromb.2016.12.040 · Cited by 14
Drokov, M. Y., Davydova, J. O., Kuzmina, L. A., Galtseva, I. V., Михайлович, К. Н., Vasilyeva, V. A., Dubnyak, D. S., Koroleva, O. M., Mikhaltsova, E. D., Popova, N. N., et al. (2017) · Leukemia Research · doi:10.1016/j.leukres.2017.01.014 · Cited by 12
Krogh, M. R., Nghiem, G. M., Halvorsen, P. S., Elle, O. J., Grymyr, O.-J., Hoff, L., & Remme, E. W. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1798-4 · Cited by 12
Altamirano‐Diaz, L., Welisch, E., Rauch, R., Miller, M. J., Park, T. S., & Norozi, K. (2017) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-017-9994-1 · Cited by 13
Bruder, A. M., McClelland, J. A., Shields, N., Dodd, K., Hau, R., van de Water, A. T. M., & Taylor, N. F. (2017) · Disability and Rehabilitation · doi:10.1080/09638288.2017.1288764 · Cited by 15
Blackford, E. B., & Estepp, J. R. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2253460 · Cited by 15
Radiologist agreement on the quantification of bronchiectasis by high-resolution computed tomography
de Brito, M. C. B., Ota, M. K., Filho, F. S. L., & Meirelles, G. D. S. P. (2017) · Radiologia Brasileira · doi:10.1590/0100-3984.2015.0146 · Cited by 12
Shi, C., Zhang, D., Xiao, Z., Wang, L., Ma, R., Chen, H., & Luo, L. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25629 · Cited by 12
Ang, T., Harkness, E. F., Maxwell, A., Lim, Y. Y., Emsley, R., Howell, A., Evans, D. G., Astley, S., & Gadde, S. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2253797 · Cited by 12
Grabowski, P. J., Narveson, M., & Siegle, S. (2017) · Military Medicine · doi:10.7205/milmed-d-16-00134 · Cited by 16
Cortés‐Castell, E., Juste, M., Palazón‐Bru, A., Monge, L., Sánchez-Ferrer, F., & Baeza, M. R. (2017) · PeerJ · doi:10.7717/peerj.3238 · Cited by 14
Comparison of imaging-based and pathological dimensions in pancreatic neuroendocrine tumors
Paiella, S., Impellizzeri, H., Zanolin, E., Marchegiani, G., Miotto, M., Malpaga, A., Robertis, R. D., D’Onofrio, M., Rusev, B. C., Capelli, P., et al. (2017) · World Journal of Gastroenterology · doi:10.3748/wjg.v23.i17.3092 · Cited by 13
Bueno‐Antequera, J., Oviedo‐Caro, M. Á., & Munguía‐Izquierdo, D. (2017) · Psychiatry Research · doi:10.1016/j.psychres.2017.05.014 · Cited by 18
de Sousa, F. B., Porto, I. M., de Figueiredo, R. C. B. Q., Pires, A. C., & Gerlach, R. F. (2017) · Archives of Oral Biology · doi:10.1016/j.archoralbio.2017.06.017 · Cited by 12
Measurement of the normal feline pituitary gland in brachycephalic and mesocephalic cats
Häußler, T. C., von Pückler, K. H., Thiel, C., Enderlein, S., Failing, K., Ondreka, N., Kramer, M., & Schmidt, M. J. (2017) · Journal of Feline Medicine and Surgery · doi:10.1177/1098612x17723774 · Cited by 13
Vertebral heart size in chinchillas (Chinchilla lanigera) using radiography and CT
Doss, G. A., Mans, C., Hoey, S., Girolamo, N. D., Stepien, R. L., & Waller, K. R. (2017) · Journal of Small Animal Practice · doi:10.1111/jsap.12715 · Cited by 12
Basic overview of method validation in the clinical virology laboratory
Newman, H., & Maritz, J. (2017) · Reviews in Medical Virology · doi:10.1002/rmv.1940 · Cited by 12
Nguyen, D. L., de Labriolle-Vaylet, C., Durand, E., Fernandez, P., Bonnin, F., Deliu, D., Besson, F. L., & Chaumet‐Riffaud, P. (2017) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000000769 · Cited by 12
Automated detection of foveal center in SD ‐ OCT images using the saliency of retinal thickness maps
Niu, S., Chen, Q., de Sisternes, L., Leng, T., & Rubin, D. L. (2017) · Medical Physics · doi:10.1002/mp.12614 · Cited by 12
Saloom, H. F., Papageorgiou, S. N., Carpenter, G. H., & Cobourne, M. T. (2017) · European Journal of Orthodontics · doi:10.1093/ejo/cjx064 · Cited by 14
Validation of a Commercial Android Smartwatch as an Activity Monitoring Platform
Amor, J. D., & James, C. J. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2732678 · Cited by 13
Ros, C., de la Fuente, C., Ródenas, S., Novellas, R., Viu, J., & Añor, S. (2017) · Veterinary Record · doi:10.1136/vr.104201 · Cited by 12
Intensity ratio to improve black hole assessment in multiple sclerosis
Adusumilli, G., Trinkaus, K. M., Sun, P., Lancia, S., Viox, J. D., Wen, J., Naismith, R. T., & Cross, A. H. (2017) · Multiple Sclerosis and Related Disorders · doi:10.1016/j.msard.2017.11.020 · Cited by 13
Castoldi, S., Cozzi, V., Baldelli, S., Fucile, S., Clementi, E., & Cattaneo, D. (2017) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000473 · Cited by 12
Real-time emotional state estimation system for Canines based on heart rate variability
Hamada, R., Ohno, K., Matsubara, S., Hoshi, T., Nagasawa, M., Kikusui, T., Kubo, T., Nakahara, E., Ikeda, K., Yamaguchi, S., et al. (2017) · IEEE International Conference on Cyborg and Bionic Systems (CBS) · doi:10.1109/cbs.2017.8266120 · Cited by 13
Computational 3D imaging to quantify structural components and assembly of protein networks
Asgharzadeh, P., Özdemir, B., Reski, R., Röhrle, O., & Birkhold, A. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.01.020 · Cited by 12
Arnalich‐Montiel, F., Ortiz-Toquero, S., Auladell, C., & Couceiro, A. (2018) · Cornea · doi:10.1097/ico.0000000000001530 · Cited by 12
Langer, R. D., Matias, C. N., Borges, J. H., Cirolini, V. X., Páscoa, M. A., Guerra‐Júnior, G., & Gonçalves, E. M. (2018) · Military Medicine · doi:10.1093/milmed/usx223 · Cited by 16
Messias, L. H. D., Polisel, E. E. C., & Manchado-Gobatto, F. D. B. (2018) · PLoS ONE · doi:10.1371/journal.pone.0194313 · Cited by 15
Knight, B., Brereton, A., Powell, R. J., & Liversedge, H. (2018) · Ultrasound · doi:10.1177/1742271x17751257 · Cited by 12
The role of contrast-enhanced computed tomography to detect renal stones
Odenrick, A., Kartalis, N., Voulgarakis, N., Morsbach, F., & Loizou, L. (2018) · Abdominal Radiology · doi:10.1007/s00261-018-1778-7 · Cited by 12
Kong, J.-S., Lee, Y., Kim, M. K., Choi, M., Heo, Y., Hyun, T. H., Kim, S. M., Lyu, E.-S., Oh, S., Park, H., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0192588 · Cited by 13
Barber, J. L., Perez, A. Z., Olsen, Ø. E., Kiparissi, F., Baycheva, M., Knaflez, D., Shah, N., & Watson, T. A. (2018) · Pediatric Radiology · doi:10.1007/s00247-018-4084-1 · Cited by 12
Obid, P., Yiu, K. K., Cheung, K., Kwan, K. Y.-H., Ruf, M., & Cheung, J. P. Y. (2018) · Spine · doi:10.1097/brs.0000000000002671 · Cited by 12
Berg-Poppe, P. J., Cesar, G. M., Tao, H., Johnson, C., & Landry, J. (2018) · International Journal of Therapy and Rehabilitation · doi:10.12968/ijtr.2018.25.6.272 · Cited by 12
Nonlinear Flow Sensor Calibration with an Accurate Syringe
Biselli, P., Nóbrega, R. S., & Soriano, F. G. (2018) · Sensors · doi:10.3390/s18072163 · Cited by 12
Tian, B., Liu, Q., Wang, X., Chen, S., Xu, B., Zhu, C., & Lu, J. (2018) · Clinical Imaging · doi:10.1016/j.clinimag.2018.08.005 · Cited by 12
Two-minute walk test: Reference equations for healthy adults in China
Zhang, J., Chen, X., Huang, S., Wang, Y., Lin, W., Zhou, R., & Zou, H. (2018) · PLoS ONE · doi:10.1371/journal.pone.0201988 · Cited by 17
Bae, J. S., Lee, J. M., Park, S., Lee, K. B., & Han, J. K. (2018) · European Journal of Radiology · doi:10.1016/j.ejrad.2018.08.015 · Cited by 12
Myhr, K. A., Pedersen, F. H. G., Kristensen, C. B., Visby, L., Hassager, C., & Møgelvang, R. (2018) · Echocardiography · doi:10.1111/echo.14112 · Cited by 15
Condylar long axis and articular eminence in MRI in patients with temporomandibular disorders
Piancino, M. G., Tepedino, M., Cavarra, F., Bramanti, E., Laganà, G., Chimenti, C., & Cirillo, S. (2018) · CRANIO® · doi:10.1080/08869634.2018.1532647 · Cited by 12
Tsai, W., Peng, Y., Wu, H., Hsu, S., Chiu, Y., Liu, L.-C., Tsai, S.-M., & Chien, K. (2018) · Scientific Reports · doi:10.1038/s41598-018-33657-8 · Cited by 12
Joo, S., Lee, K., & Song, C. (2018) · BioMed Research International · doi:10.1155/2018/2439312 · Cited by 12
Fischer, C., & Penzel, T. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aaf298 · Cited by 13
de Knegt, M. C., Haugen, M., Linde, J. J., Kühl, J. T., Nordestgaard, B. G., Køber, L., Hove, J. D., & Kofoed, K. F. (2018) · PLoS ONE · doi:10.1371/journal.pone.0207980 · Cited by 12
Validity and reliability of a standalone low-end 50-Hz GNSS receiver during running
Padulo, J., Iuliano, E., Brisola, G. M. P., Iacono, A. D., Zagatto, A. M., Lupo, C., Fuglsang, T., Ardigò, L. P., & Čular, D. (2018) · Biology of Sport · doi:10.5114/biolsport.2019.79974 · Cited by 12
Queirós, S., Morais, P., Fehske, W., Papachristidis, A., Voigt, J., Fonseca, J. C., D’hooge, J., & Vilaça, J. L. (2019) · International journal of cardiac imaging · doi:10.1007/s10554-019-01532-w · Cited by 12
Júnior, J. F. M., Bravo‐Valenzuela, N. J., Nardozza, L. M. M., Peixoto, A. B., Mattar, R., Martins, W. P., Tonni, G., & Júnior, E. A. (2019) · Journal of Perinatal Medicine · doi:10.1515/jpm-2018-0342 · Cited by 12
Gaibazzi, N., Davies, J. E., Tuttolomondo, D., Pontone, G., Guaricci, A. I., Lorenzoni, V., Benatti, G., Siniscalchi, C., & Pastorini, G. (2019) · International Journal of Cardiology · doi:10.1016/j.ijcard.2019.01.104 · Cited by 12
Phillips, J. L., Heneka, N., Lovell, M. R., Lam, L. T.-M., Davidson, P. M., Boyle, F. M., McCaffrey, N., Fielding, S., & Shaw, T. J. (2019) · Trials · doi:10.1186/s13063-018-3152-z · Cited by 14
Pfister, J., Blaimer, M., Kullmann, W., Bartsch, A. J., Jakob, P. M., & Breuer, F. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27657 · Cited by 15
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.