Comparison of total haemoglobin mass measured with the optimized carbon monoxide rebreathing method across different Radiometer™ ABL-80 and OSM-3 hemoximeters
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A new Radiometer™ hemoximeter (ABL-80) has recently become available to measure carboxyhaemoglobin concentration for the optimized CO-rebreathing method (oCOR-method). Within the English Institute of Sport (EIS), hemoximeters are used in three different laboratories; therefore, precision and agreement of total haemoglobin mass (tHbmass) determination across sites is essential, and comparison to the previous model OSM-3 is desirable. Six male and one female (age 30 ± 6 years, body mass 78.1 ± 10.6 kg) undertook the oCOR-method. Venous blood (~2 ml) was sampled immediately before and at 7 min during the oCOR-method; with seven replicates from each time point simultaneously analysed on five different Radiometer™ hemoximeters [OSM-3(1), OSM-3(2), ABL-80(1), ABL-80(2) and ABL-80(3)]. There were no differences (p > 0.05) between Δ%HbCO or mean tHbmass analysed with five different hemoximeters (OSM-3(1): 886 ± 167 g; OSM-3(2): 896 ± 160 g: ABL-80(1): 904 ± 157 g; ABL-80(2): 906 ± 163 g: ABL-80(3): 906 ± 162 g). However, the Bland-Altman plot revealed that there was closer agreement between ABL-80 machines for tHbmass than for the OSM-3. The variance (i.e. % error) across replicate samples decreased as the number of samples increased, with the error derived from the 'worse-case' scenario (single samples) being 1.2 to 1.6 fold greater in the OSM-3 than the ABL-80. Although there were no differences in the average tHbmass measured with five different hemoximeters, the new ABL-80 were in better agreement with each other compared to the old OSM-3. Previously, five replicates were required to achieve a low error using the OSM-3; however, three replicates are sufficient with the ABL-80 model to produce an error of ≤ 1% in tHbmass.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“values in keeping with other institutions using the oCOR method.19,46”
From Hemoglobin concentration, total hemoglobin mass and plasma volume in patients: implications for anemia (2017) · cites this paper as [46]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Impact of Alterations in Total Hemoglobin Mass on V˙O2max
Schmidt, W., & Prommer, N. (2010) · Exercise and Sport Sciences Reviews · doi:10.1097/jes.0b013e3181d4957a · Cited by 265
Determination of hemoglobin mass and blood volume with CO: evaluation and application of a method
Burge, C. M., & Skinner, S. L. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.79.2.623 · Cited by 215 · cited 1×
“…designed, the CO-rebreathing method has undergone numerous small adjustments in aspects such as the duration of breathing (Thomsen et al 1991, Burge and Skinner 1995, Schmidt and Prommer 2005), the timing of capillary blood sampling (Gore et al 2006, Prommer and Schmidt 2007), the…”
Method
Research works printed but not linked: 21
- 10.1016/j.jsams.2010.07.007 · DOI
- 10.1111/j.1399-6576.1993.tb03777.x · DOI
- 10.1080/17461391.2011.606843 · DOI
- 10.1152/japplphysiol.00719.2007 · DOI
- 10.1249/JSR.0b013e31825640d5 · DOI
- 10.1113/expphysiol.2010.054031 · DOI · Paper page
- 10.1136/bjsports-2013-092840 · DOI · Paper page
- 10.1249/01.mss.0000222848.35004.41 · DOI
- 10.1152/japplphysiol.00505.2005 · DOI · Paper page
- 10.1111/j.1600-0838.2011.01316.x · DOI
- 10.2165/00007256-200030010-00001 · DOI · Paper page
- 10.1046/j.1365-2044.2000.01166.x · DOI
- 10.1007/s00421-007-0439-2 · DOI
- 10.1249/MSS.0b013e3181820942 · DOI · Paper page
- 10.1007/s00421-005-0050-3 · DOI · Paper page
- 10.3109/00365513.2010.534174 · DOI
- 10.3109/00365519109091106 · DOI
- Turner G, 2014, Physiol. Meas., 35, N11, 10.1088/0967-3334/35/2/N11 · DOI
- 10.1371/journal.pone.0073990 · DOI · Paper page
- Vogt M, 2001, J. Appl. Physiol., 91, 173, 10.1152/jappl.2001.91.1.173 · DOI · Paper page
- Zijlstra W G, 1988, Clin. Chem., 34, 149, 10.1093/clinchem/34.1.149 · doi:10.1093/clinchem/34.1.149
Cited by
Otto, J. M., Plumb, J. O. M., Clissold, E., Kumar, S. B., Wakeham, D. J., Schmidt, W., Grocott, M. P. W., Richards, T., & Montgomery, H. E. (2017) · Haematologica · doi:10.3324/haematol.2017.169680 · Cited by 93
“4%: data not shown), values in keeping with other institutions using the oCOR method.(19,46) Finally, the oCOR method is quick and simple, avoids the technical difficulties of working with radiolabeled compounds,(40) offers an inconsequential burden for patients, is minimally invasive, and is safe even in patients wit…”
Method
Metadata
- Authors
- Turner, G., Richardson, A. J., Maxwell, N. S., & Pringle, J. S. M.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2014-11-24
- Volume
- 35
- Issue
- 12
- Pages
- N41-N49
- ISSN
- 0967-3334
- 1361-6579
- Cited by
- 9
- References
- 3
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of total haemoglobin mass measured with the optimized carbon monoxide rebreathing method across different Radiometer™ ABL-80 and OSM-3 hemoximeters. https://app.cochat.ai/papers/10.1088/0967-3334/35/12/n41
- The paper
- Turner, G., Richardson, A. J., Maxwell, N. S., & Pringle, J. S. M. (2014). Comparison of total haemoglobin mass measured with the optimized carbon monoxide rebreathing method across different Radiometer™ ABL-80 and OSM-3 hemoximeters. Physiological Measurement. https://doi.org/10.1088/0967-3334/35/12/n41
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.