STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 31,201–31,300 of 47,868
Validation of the Italian food composition database of the European institute of oncology
Fidanza, F., & Perriello, G. (2002) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601435 · Cited by 9
Optic Disc Parameters From Optovue Optical Coherence Tomography
Mesiwala, N. K., Pekmezci, M., Porco, T. C., & Lin, S. C. (2011) · Journal of Glaucoma · doi:10.1097/ijg.0b013e31821206e8 · Cited by 9
Kasius, K. M., Claes, F., Meulstee, J., Weinstein, H. C., & Verhagen, W. I. M. (2014) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000069 · Cited by 9
Barletta, G., & Bene, M. R. D. (2011) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0b013e328343c2b8 · Cited by 9
Kamijo‐Ikemori, A., Sugaya, T., Yoshida, M., Hoshino, S., Akatsu, S., Yamazaki, S., Kimura, K., & Shibagaki, Y. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-1084 · Cited by 9
Han, B., Ivanov, K., Wang, L., & Yan, Y. (2015) · Wireless Mobile Communication and Healthcare · doi:10.4108/eai.14-10-2015.2261689 · Cited by 9
P4.57 STIFFNESS OF THE LARGE ARTERIES IN INDIVIDUALS WITH AND WITHOUT DOWN SYNDROME
Rodrigues, A. N., Coelho, L. O., Gonçalves, W. L. S., Vasconcellos, M., Cunha, R. S., Gouvêa, S. A., & Abreu, G. (2012) · Artery Research · doi:10.1016/j.artres.2012.09.204 · Cited by 9
Joint torque variability and repeatability during cyclic flexion-extension of the elbow
Ballaz, L., Raison, M., Detrembleur, C., Gaudet, G., & Lemay, M. (2016) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-016-0033-1 · Cited by 15
Coupling of dyspnea perception and occurrence of tachypnea during exercise
Tsukada, S., Masaoka, Y., Yoshikawa, A., Okamoto, K., Homma, I., & Izumizaki, M. (2016) · The Journal of Physiological Sciences · doi:10.1007/s12576-016-0452-5 · Cited by 10
Intralaboratory Reproducibility of Interpretation of Pap Smears: Results of an Experiment
Duca, P., Braga, M., Chiappa, L., Piffer, R., & Turolla, E. (1988) · Tumori Journal · doi:10.1177/030089168807400620 · Cited by 9
Effects of multisensory and motor stimulation on the behavior of people with dementia
Sposito, G., Barbosa, A., de Figueiredo, D. M. P., Yassuda, M. S., & Marques, A. S. P. D. D. (2016) · Dementia · doi:10.1177/1471301215592080 · Cited by 14
Lack of night-to-night variability of sleep-disordered breathing measured during home monitoring
Davidson, T. M., Gehrman, P., & Ferreyra, H. A. (2003) · Ear Nose & Throat Journal · doi:10.1177/014556130308200215 · Cited by 9
Repeatability of Associated Phoria Tests
Alhassan, M., Hovis, J. K., & Chou, R. B. (2015) · Optometry and Vision Science · doi:10.1097/opx.0000000000000638 · Cited by 9
Lo, W. L. A., & Huang, D. F. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-016-9894-9 · Cited by 10
Ruffion, A., Marionneau, N., TAIEB, C., & Perrin, P. (2005) · PubMed · Cited by 9
Seng, K., Chen, Y., Wang, T., Chai, A. K. M., Fun, D. C. Y., Teo, Y. S., Tan, P. M. S., Ang, W. H., & LEE, J. K. W. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/4/485 · Cited by 9
Validity of a Neurological Scoring System for Canine X-Linked Myotubular Myopathy
Snyder, J. M., Meisner, A., Mack, D. L., Goddard, M. A., Coulter, I. T., Grange, R. W., & Childers, M. K. (2015) · Human Gene Therapy Clinical Development · doi:10.1089/humc.2015.049 · Cited by 11
Saban, B., & Masharawi, Y. (2016) · Physiotherapy · doi:10.1016/j.physio.2016.06.003 · Cited by 9
Heart rate inflection point estimates the anaerobic threshold in overweight and obese young adults
Cambri, L. T., Novelli, F. I., Sales, M. M., de Sousa, L. C. D. J. L., Queiroz, M. G., Dias, A. R. L., Meireles, K., & Arsa, G. (2016) · Sport Sciences for Health · doi:10.1007/s11332-016-0304-y · Cited by 9
Ahankari, A. S., Dixit, J. V., Fogarty, A., Tata, L. J., & Myles, P. R. (2016) · BMJ Innovations · doi:10.1136/bmjinnov-2016-000139 · Cited by 9
Oğul, H., Güzel, Y., Pirimoğlu, B., Tuncer, K., Polat, G., Ergun, F., Sade, R., Bayraktutan, Ü., Yüce, İ., & Kantarcı, M. (2016) · European Journal of Radiology · doi:10.1016/j.ejrad.2016.08.010 · Cited by 9
Feasibility and reliability of carotid intima–media thickness measurements in nonsedated infants
Mivelaz, Y., Bernardo, S. D., Boulos, T., Prša, M., Vial, Y., Chioléro, A., & Sekarski, N. (2016) · Journal of Hypertension · doi:10.1097/hjh.0000000000001065 · Cited by 10
Chen, Y.-C., & Hsiao, T. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0233-7 · Cited by 10
TOUNO, M., Rafamantanantsoa, H. H., Ebine, N., Peng, H.-Y., YOSHITAKE, Y., Tanaka, H., & Saitoh, S. (2003) · 体力科學 · doi:10.7600/jspfsm1949.52.265 · Cited by 9
Manoni, F., Gessoni, G., Fogazzi, G. B., Alessio, M. G., Caleffi, A., Gambaro, G., Epifani, M. G., Pieretti, B., Perego, A. F., Ottomano, C., et al. (2016) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.1007/s13631-016-0127-5 · Cited by 9
Chen, M., Xia, J., Pei, G., Zhang, Y., Wu, S., Qin, Y., Deng, Y., Guo, S., Guo, Y., Xu, G., et al. (2016) · BMC Nephrology · doi:10.1186/s12882-016-0345-0 · Cited by 9
Domínguez‐Vicent, A., Trussardi, C., Wogatai, U., Montés‐Micó, R., & Brautaset, R. (2016) · Journal of Refractive Surgery · doi:10.3928/1081597x-20160721-03 · Cited by 9
A note on statistical repeatability and study design for high-throughput assays
Nicholson, G., & Holmes, C. C. (2016) · Statistics in Medicine · doi:10.1002/sim.7175 · Cited by 10
Nielsen, F. K., Egund, N., Jørgensen, A., Peters, D. A., & Jurik, A. G. (2016) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-016-1336-9 · Cited by 9
Cooperstein, R., & Young, M. D. (2016) · Chiropractic & Manual Therapies · doi:10.1186/s12998-016-0131-x · Cited by 10
Ostenfeld, E., Evaldsson, A. W., Engblom, H., Ingvarsson, A., Roijer, A., Meurling, C., Holm, J., Rådegran, G., & Carlsson, M. (2016) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12398 · Cited by 9
Karsenty, C., Hadeed, K., Dulac, Y., Semet, F., Alacoque, X., Breinig, S., Léobon, B., Acar, P., & Hascoët, S. (2016) · Archives of cardiovascular diseases · doi:10.1016/j.acvd.2016.09.003 · Cited by 9
Ford, T. J. (2016) · Journal of the American Academy of Child & Adolescent Psychiatry · doi:10.1016/j.jaac.2016.09.177 · Cited by 10
Nakamura, T., Okamura, T., Fujimura, T., Yamada, J., Nao, T., Tateishi, H., Maeda, T., Oda, T., Shiraishi, K., Nakashima, T., et al. (2017) · International journal of cardiac imaging · doi:10.1007/s10554-017-1080-8 · Cited by 9
Left ventricular longitudinal strain in soccer referees
Gianturco, L., Bodini, B. D., Gianturco, V., Lippo, G., Solbiati, A., & Turiel, M. (2017) · Oncotarget · doi:10.18632/oncotarget.15242 · Cited by 9
Mohammadi, V., Hilfiker, R., Jafarnezhadgero, A., Jamialahmadi, S., Ardakani, M. K., & Granacher, U. (2017) · Annals of Applied Sport Science · doi:10.29252/acadpub.aassjournal.5.3.31 · Cited by 9
Garcia, R., Labarre, Q., Degand, B., Ingrand, P., Gal, F. L., Bonnet, B., Delaubier, A., Guillou, C. L., Gellen, B., Coisne, D., et al. (2017) · Echocardiography · doi:10.1111/echo.13426 · Cited by 9
An integrated blood pressure measurement system for suppression of motion artifacts
Abderahman, H. N., Dajani, H. R., Bolić, M., & Groza, V. Z. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2017.03.007 · Cited by 9
Ichikawa, J., Mori, T., Kodaka, M., Nishiyama, K., Ozaki, M., & Komori, M. (2017) · Perfusion · doi:10.1177/0267659117692661 · Cited by 9
Validity of thoracic respiratory inductive plethysmography in high body mass index subjects
Rétory, Y., David, P., de Picciotto, C., Niedzialkowski, P., Bonay, M., & Petitjean, M. (2017) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2017.03.009 · Cited by 10
Pazzaglia, U. E., Congiu, T., Sibilia, V., Casati, L., Minini, A., & Benetti, A. (2017) · Journal of Morphology · doi:10.1002/jmor.20681 · Cited by 9
Raila, J., KAWASHIMA, C., Sauerwein, H., Hülsmann, N., Knörr, C., Myamoto, A., & Schweigert�, F. J. (2017) · BMC Veterinary Research · doi:10.1186/s12917-017-1042-3 · Cited by 13
Peterson, M. E., Rishniw, M., Bilbrough, G. E. A., & Cote, K. B. (2017) · Journal of Feline Medicine and Surgery · doi:10.1177/1098612x17708918 · Cited by 9
Lundgaard, E., Wouda, M. F., & Strøm, V. (2017) · Spinal Cord · doi:10.1038/sc.2017.34 · Cited by 9
Assessing Passeriformes health in South Texas via select venous analytes
Pistone, J. P., Heatley, J. J., Campbell, T. A., & Voelker, G. (2017) · Comparative Biochemistry and Physiology Part B Biochemistry and Molecular Biology · doi:10.1016/j.cbpb.2017.06.002 · Cited by 10
Deskur-Śmielecka, E., Kotlińska–Lemieszek, A., Chudek, J. T., & Wieczorowska–Tobis, K. (2017) · Clinical Interventions in Aging · doi:10.2147/cia.s130583 · Cited by 9
van de Bunt, F., Pearl, M. L., Lee, E. K., Peng, L., & DiDomenico, P. B. (2017) · Pediatric Radiology · doi:10.1007/s00247-017-3882-1 · Cited by 9
Hambly, K., Sibley, R. C., & Ockendon, M. (2012) · Kent Academic Repository (University of Kent) · Cited by 9
Statistical Analysis of Microbiological Diagnostic Tests
Baveja, C. P., & Aggarwal, P. (2017) · Indian Journal of Medical Microbiology · doi:10.4103/ijmm.ijmm_16_215 · Cited by 10
Kabbara, S. W., Zangwill, L. M., Mundae, R. S., Hammel, N., Bowd, C., Medeiros, F. A., Weinreb, R. N., & Belghith, A. (2017) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2016-310111 · Cited by 9
Determination of protein thiolation index (PTI) as a biomarker of oxidative stress in human serum
Giustarini, D., Galvagni, F., Colombo, G., Dalle‐Donne, I., Milzani, A., Aloisi, A. M., & Rossi, R. (2017) · Analytical Biochemistry · doi:10.1016/j.ab.2017.09.010 · Cited by 9
Mariacher, S., Ebner, M., Hurst, J., Szurman, P., & Januschowski, K. (2017) · Experimental Eye Research · doi:10.1016/j.exer.2017.10.020 · Cited by 9
Fully automated contour detection of the ascending aorta in cardiac 2D phase-contrast MRI
Codari, M., Scarabello, M., Secchi, F., Sforza, C., Baselli, G., & Sardanelli, F. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2017.11.010 · Cited by 9
Choukem, S. P., Manases, T., Mefo’o, J. P. N., Dimala, C. A., Mboue-Djieka, Y., Sobngwi, E., & Kengne, A. P. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.12.008 · Cited by 9
Donnelly, J. P., Lopata, C. J., Jordan, A. K., Thomeer, M. L., Rodgers, J. D., McDonald, C. A., & Nelson, A. T. (2017) · Measurement and Evaluation in Counseling and Development · doi:10.1080/07481756.2017.1395706 · Cited by 9
Butala, N. M., Kramer, D. B., Shen, C., Strom, J. B., Kennedy, K. F., Wang, Y., Valsdottir, L. R., Wasfy, J. H., & Yeh, R. W. (2018) · Annals of Internal Medicine · doi:10.7326/m17-1492 · Cited by 10
Iannessi, A., Beaumont, H., Hébert, C., Dittlot, C., & Falewee, M.-N. (2018) · PLoS ONE · doi:10.1371/journal.pone.0192124 · Cited by 9
Halsne, T., Müller, E. G., Spiten, A.-E., Sherwani, A. G., Mikalsen, L. T. G., Revheim, M.-E. R., & Stokke, C. (2018) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.117.204586 · Cited by 9
A Comparison of Auto-Refraction and Subjective Refraction: Based on Photorefractor (VS100)
Lee, K.-H., & Shim, H.-S. (2018) · Journal of Korean Ophthalmic Optics Society · doi:10.14479/jkoos.2018.23.1.39 · Cited by 9
Tschopp, M., Swanenburg, J., Wertli, M. M., Langenfeld, A., McCabe, C., Lewis, J. S., Baertschi, E., & Brunner, F. (2018) · Der Schmerz · doi:10.1007/s00482-018-0294-6 · Cited by 10
Kim, S., Miller, M. E., Lin, M., Rejeski, W. J., Kritchevsky, S. B., Marsh, A. P., & Groban, L. (2018) · European Review of Aging and Physical Activity · doi:10.1186/s11556-018-0194-x · Cited by 10
Zahran, S., McDonald, F., & Sherriff, M. (2018) · Journal of Orthodontics · doi:10.1080/14653125.2018.1490871 · Cited by 9
Fraser, A. N., Tsukanaka, M., Fjalestad, T., Madsen, J. E., & Röhrl, S. M. (2018) · Journal of Orthopaedic Research® · doi:10.1002/jor.24111 · Cited by 9
Diagnosing orthostatic hypotension with continuous and interval blood pressure measurement devices
Breeuwsma, A. C., Hartog, L., Kamper, A., Groenier, K., Bilo, H., Kleefstra, N., & van Hateren, K. V. (2018) · Journal of Human Hypertension · doi:10.1038/s41371-018-0091-9 · Cited by 7
Chromatic techniques for in vivo monitoring jaundice in neonate tissues
Sufian, A. T., Jones, G. R., Shabeer, H. M., Elzagzoug, E., & Spencer, J. W. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aadbdb · Cited by 10
Myhre, J. B., Johansen, A. M. W., Hjartåker, A., & Andersen, L. F. (2018) · PLoS ONE · doi:10.1371/journal.pone.0202907 · Cited by 9
Steemburgo, T., Lazzari, C., Farinha, J. B., de Paula, T. P., Viana, L. V., Reischak-Oliveira, Á., & de Azevedo, M. J. (2019) · Archives of Endocrinology and Metabolism · doi:10.20945/2359-3997000000103 · Cited by 12
Development of a visually guided Raman spectroscopy probe for cervical assessment during pregnancy
O'Brien, C. M., Cochran, K. J., Masson, L. E., Goldberg, M., Marple, E. T., Bennett, K., Reese, J., Slaughter, J. C., Newton, J. M., & Mahadevan-Jansen, A. M. (2018) · Journal of Biophotonics · doi:10.1002/jbio.201800138 · Cited by 9
Tien, H. C. N., Peng, H. T., Nascimento, B., Callum, J., Rhind, S. G., & Beckett, A. (2018) · Panamerican Journal of Trauma Critical Care & Emergency Surgery · doi:10.5005/jp-journals-10030-1217 · Cited by 9
Sun, J., Wu, G., Shan, F., & Meng, Z. (2018) · Academic Radiology · doi:10.1016/j.acra.2018.09.027 · Cited by 9
Exploring the influence from whole blood DNA extraction methods on Infinium 450K DNA methylation
Hjorthaug, H. S., Gervin, K., Mowinckel, P., & Munthe‐Kaas, M. C. (2018) · PLoS ONE · doi:10.1371/journal.pone.0208699 · Cited by 9
Rodríguez‐Mañero, M., Azcárate, P., Kreidieh, B., Alvez, M. T., Martínez‐Monzonís, A., Díaz-Dorronsoro, A., Cid‐Menéndez, A., González‐Juanatey, J. R., Barba-Cosials, J., Rábago, G., et al. (2019) · Echocardiography · doi:10.1111/echo.14232 · Cited by 9
Papaioannou, T. G., Fasoulis, R., Toumpaniaris, P., Tsioufis, C., Dilaveris, P., Soulis, D., Koutsouris, D., & Tousoulis, D. M. (2019) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.02.002 · Cited by 12
Computed tomographic dimensions of the normal adult equine eye
Hollis, A. R., Dixon, J., Berlato, D., Murray, R., & Weller, R. (2019) · Veterinary Ophthalmology · doi:10.1111/vop.12636 · Cited by 9
Jenner, J., Sörensson, P., Pernow, J., Caidahl, K., & Eriksson, M. J. (2019) · Clinical Medicine Insights Cardiology · doi:10.1177/1179546819831980 · Cited by 10
Lemańska, A., Poole, K., Aning, J. J., Griffin, B. A., MANDERS, R. J. F., Saxton, J., Wainwright, J., & Faithfull, S. (2019) · European Review of Aging and Physical Activity · doi:10.1186/s11556-018-0207-9 · Cited by 9
Sgambato, M. R., Wahrlich, V., & dos Anjos, L. A. (2019) · Clinical Nutrition ESPEN · doi:10.1016/j.clnesp.2019.03.003 · Cited by 11
Mateo, F., Carrasco, J. J., Aguilar‐Rodríguez, M., Soria‐Olivas, E., Bonanad, S., Querol, F., & Pérez‐Alenda, S. (2019) · Haemophilia · doi:10.1111/hae.13744 · Cited by 9
Alves, V. G. F., da Rocha, E. E. M., González, M. C., da Fonseca, R. B. V., & Silva, M. H. D. N. (2019) · Journal of Parenteral and Enteral Nutrition · doi:10.1002/jpen.1589 · Cited by 9
Raake, P. W. J., Barthelmes, J., Krautz, B., Buss, S. J., Huditz, R., Schlegel, P., Weber, C., Stangassinger, M., Haberkorn, U., Katus, H. A., et al. (2019) · International journal of cardiac imaging · doi:10.1007/s10554-019-01610-z · Cited by 10
Gürtler, C., Laible, M., Schwabe, W., Steinhäuser, H., Li, X., Liu, S., Schlombs, K., & Şahin, U. (2018) · Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2018.02.004 · Cited by 9
Sampling Apple Trees to Accurately Estimate Mean Fruit Weight and Fruit Size Distribution
Marini, R. P., Schupp, J. R., Baugher, T. A., & Crassweller, R. M. (2019) · HortScience · doi:10.21273/hortsci13956-19 · Cited by 9
Is the Energy Expenditure Provided by Exergames Valid?
Viana, R. B., Gentil, P., Andrade, M. S., Vancini, R. L., & de Lira, C. A. B. (2019) · International Journal of Sports Medicine · doi:10.1055/a-0955-9394 · Cited by 10
Clinical performance evaluation of the new hematology analyzer Mindray BC‐6000
Shen, Y., Cao, J. P., Zhou, Z., Wang, Y., Shen, Y., & He, J. (2019) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13075 · Cited by 9
Falck, R. S., Best, J. R., Li, M. C. R., Eng, J. J., & Liu-Ambrose, T. Y. L. (2019) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2019.00203 · Cited by 10
VALIDITY AND RELIABILITY OF FREE SOFTWARE FOR BIDIMENTIONAL GAIT ANALYSIS
Quixadá, A. P., Onodera, A. N., Peña, N., Miranda, J. G. V., & Sá, K. N. (2017) · Revista Pesquisa em Fisioterapia · doi:10.17267/2238-2704rpf.v7i4.1648 · Cited by 9
Short-Term Stability of Hematologic Parameters in Frozen Whole Blood
Tang, O., Selvin, E., Arends, V. L., & Saenger, A. K. (2019) · The Journal of Applied Laboratory Medicine · doi:10.1373/jalm.2018.028357 · Cited by 13
Intharakham, K., Panerai, R. B., Katsogridakis, E., Lam, M. Y., Llwyd, O., Salinet, A. S. M., Nogueira, R. D. C., Haunton, V. J., & Robinson, T. G. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab39d3 · Cited by 9
Heart-Thigh Cuff Pulse Wave Velocity: A Novel Nontechnical Measure of Arterial Stiffness
Fico, B. G., Gourley, D., Wooten, S. V., & Tanaka, H. (2019) · American Journal of Hypertension · doi:10.1093/ajh/hpz124 · Cited by 9
Gregoric, M., Kotnik, K. Z., Pigac, I., & Blenkuš, M. G. (2019) · Nutrients · doi:10.3390/nu11092234 · Cited by 9
de Melo, C. A. O., Lopes, J. G., Andrade, A. O., Trindade, R. M. P., & Magalhães, R. D. S. (2019) · Anais da Academia Brasileira de Ciências · doi:10.1590/0001-3765201920180165 · Cited by 9
Reference equation for maximal voluntary ventilation in children and adolescents
Silva, J. C., Carvalho, I. E., Corso, S. D., & Lanza, F. C. (2019) · Pediatric Pulmonology · doi:10.1002/ppul.24576 · Cited by 9
Dullenkopf, A., Horn, K., Steurer, M. P., Heß, F., & Welter, J. (2019) · Journal of Anesthesia · doi:10.1007/s00540-019-02712-7 · Cited by 9
Moreno‐Galarraga, L., Zallo, N. Á., Olid, A. O., Miranda-Ferreiro, G., Martínez‐González, M. Á., & Martín‐Calvo, N. (2019) · Gaceta Sanitaria · doi:10.1016/j.gaceta.2019.08.012 · Cited by 10
Tinsley, G. M., & Moore, M. L. (2019) · Nutrition Research · doi:10.1016/j.nutres.2019.12.006 · Cited by 9
do Nascimento, I. B., & Fleig, R. (2020) · Clinics · doi:10.6061/clinics/2020/e1428 · Cited by 9
Daste, C., Abdoul, H., Foissac, F., Papelard, A., Alami, S., Kwakkenbos, L., Carrier, M., Lefèvre‐Colau, M., Thombs, B. D., Poiraudeau, S., et al. (2020) · British Journal of Dermatology · doi:10.1111/bjd.18922 · Cited by 9
Kc, A., Schaefer, M. K., Stone, N. D., & Perz, J. F. (2020) · Infection Control and Hospital Epidemiology · doi:10.1017/ice.2020.78 · Cited by 9
Gade, J., Astrup, A. V., Vinther, A., & Zerahn, B. (2020) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12633 · Cited by 11
Determining MAOD Using a Single Exhaustive Severe Intensity Test
Valenzuela, J. R., Riojas, A. E., McFarlin, B. K., Vingren, J. L., & Hill, D. W. (2020) · International journal of exercise science · doi:10.70252/fbds3074 · Cited by 10
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.