STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 40,401–40,500 of 47,868
Sotgia, S., Mangoni, A. A., Pintus, G., Carru, C., & Zinellu, A. (2017) · Future Science OA · doi:10.4155/fsoa-2017-0004 · Cited by 2
Nagla, J. R. (2015) · WPI Publishing eBooks · doi:10.1201/b18241-11 · Cited by 2
Freesmeyer, M. G., Gabler, A. S., Kühnel, C., & Winkens, T. (2017) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000001677 · Cited by 2
A novel method to evaluate gamma camera rotational uniformity and sensitivity variation
Kappadath, S. C., Erwin, W. D., & Wendt, R. E. (2009) · Medical Physics · doi:10.1118/1.3125642 · Cited by 2
Simulated altitude exposure assessment by hyperspectral imaging
Călin, M. A., Macovei, A., Miclos, S. I., Parasca, S. V., Savastru, R., & Hristea, R. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.5.056012 · Cited by 2
Chew, C. R., Lam, T., Chan, S. T. F., & Chin‐Lenn, L. (2017) · ANZ Journal of Surgery · doi:10.1111/ans.14045 · Cited by 2
Pertinhez, T. A., Casali, E., Zambianchi, L., Spisni, A., & Baricchi, R. (2017) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2017.06.024 · Cited by 2
Eagle, B., Williams, D. J., & Dingley, J. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000002172 · Cited by 2
Comparison of the Measurements of Two Different Body Composition Analyzers
Kera, T., Kawai, H., Yoshida, H., Hirano, H., Kojima, M., Fujiwara, Y., Ihara, K., & Obuchi, S. P. (2015) · Rigakuryoho Kagaku · doi:10.1589/rika.30.847 · Cited by 2
Automatic measurement of the sinus of Valsalva by image analysis
Mairesse, F., Blanchard, C., Boucher, A., Sliwa, T. M., Lalande, A., & Voisin, Y. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2017.06.014 · Cited by 2
Elschner, C., Korn, P., Hauptstock, M., Schulz, M. C., Range, U., Jünger, D., & Scheler, U. (2017) · PLoS ONE · doi:10.1371/journal.pone.0179249 · Cited by 3
Testing for failure of passive transfer: are all tests made equal?
Cuttance, E., Mason, W., & Laven, R. A. (2017) · Livestock · doi:10.12968/live.2017.22.5.244 · Cited by 2
Assessing left ventricular ejection time from wrist cuff pulse waveforms: Algorithm and evaluation
Jilek, J., & Štork, M. (2017) · International Conference on Applied Electronics · doi:10.23919/ae.2017.8053584 · Cited by 2
Reproducibilidad de las mediciones clínicas
Rojas, C., Puerta, J. A., Gómez, J., & Calvache, J. A. (2016) · RFS Revista Facultad de Salud · doi:10.25054/rfs.v8i1.1335 · Cited by 2
Liu, M., Chen, Z., & Ma, L. (2017) · Europe PMC (PubMed Central) · doi:10.3969/j.issn.1673-4254.2017.09.17 · Cited by 2
Survey of mean particle length in whole-plant corn silage
Salvati, G. G. S., Ferraretto, L. F., Júnior, G. S. D., Drago, F., & SHAVER, R. D. (2017) · The Professional Animal Scientist · doi:10.15232/pas.2017-01631 · Cited by 2
Ha, D. Y., & Jung, J. W. (2017) · Journal of the Korean Ophthalmological Society · doi:10.3341/jkos.2017.58.12.1341 · Cited by 2
NICBPM: Non-invasive cuff-less blood pressure monitor
Aboughaly, A. A., Iqbal, D., Ghany, M. A. A. E., & Hofmann, K. (2017) · doi:10.1109/icm.2017.8268843 · Cited by 2
An Alternative Method to Calculate Simplified Projected Aortic Valve Area at Normal Flow Rate
Ferreira, J. S. S. M., Moreira, N., Ferreira, A. R., Mendes, S. L., Martins, R., Ferreira, M. J., & Pêgo, M. (2018) · Arquivos Brasileiros de Cardiologia · doi:10.5935/abc.20180018 · Cited by 2
Follow-up for patients with obstructive sleep apnea syndrome using a portable recording device.
Miyata, S., Noda, A., Honda, K., Nakata, S., Suzuki, K., Nakashima, T., & Koike, Y. (2007) · PubMed · doi:10.18999/nagjms.69.1-2.37 · Cited by 3
Calculating gamma camera uniformity parameters: Beyond the vendor-specific protocol
Pandey, A., Sharma, P., Kumar, J., Saroha, K., Patel, C. D., Bal, C. S., & Kumar, R. (2017) · Indian Journal of Nuclear Medicine · doi:10.4103/ijnm.ijnm_67_17 · Cited by 2
A study of the reproducibility and reliability of the musculo-articular stiffness of the ankle joint
París-García, F., Barroso, A., & París, F. (2018) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2018.03.017 · Cited by 5
Subarachnoid space diameter in chromosomally abnormal fetuses at 11–13 weeks’ gestation
Ferreira, C. G., Rouxinol-Dias, A. L., Loureiro, T., & Nicolaides, K. H. (2018) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2018.1425833 · Cited by 2
Doverspike, G. A., Bendick, P. J., Brown, D., Hubbard, J., Shelpman, D., & Shanley, C. J. (2004) · Journal for Vascular Ultrasound · doi:10.1177/154431670402800101 · Cited by 2
Estimating B1+ in the breast at 7 T using a generic template
van Rijssel, M. J., Pluim, J. P. W., Luijten, P. R., Gilhuijs, K. G. A., Raaijmakers, A. J. E., & Klomp, D. W. J. (2018) · NMR in Biomedicine · doi:10.1002/nbm.3911 · Cited by 2
Mizéhoun-Adissoda, C., Aguèh, V., Yemoa, L. A., Sègla, B. I., Alihonou, F., Roger, G. J., Houinato, D. S., Desport, J., & Bigot, A. K. (2018) · African Journal of Food Science · doi:10.5897/ajfs2017.1656 · Cited by 2
Considering interpersonal differences in validating wearable sleep-tracking technologies
Liang, Z., & Martell, M. A. C. (2017) · International Conference on Mobile Computing and Ubiquitous Network (ICMU) · doi:10.23919/icmu.2017.8330096 · Cited by 2
Injection-Less Conductance Method for Vascular Sizing
Dabiri, A. E., & Kassab, G. S. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00371 · Cited by 2
Myocardial motion analysis based on an optical flow method using tagged MR images
Tabata, D., Isoda, H., Kato, K., Matsubara, H., Kosugi, T., Kosugi, T., Terada, M., Fukuyama, A., Komori, Y., & Naganawa, S. (2018) · Radiological Physics and Technology · doi:10.1007/s12194-018-0456-3 · Cited by 2
Koirala, N., & McLennan, G. (2017) · IEEE Western New York Image and Signal Processing Workshop (WNYISPW) · doi:10.1109/wnyipw.2017.8356253 · Cited by 2
Ali, S., Byanyima, R. K., Ononge, S., Ictho, J., Nyamwiza, J., Loro, E. L. E., Mukisa, J., Musewa, A., Nalutaaya, A., Ssenyonga, R., et al. (2018) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-018-1769-2 · Cited by 2
Rampersad, N., & Hansraj, R. (2018) · African Health Sciences · doi:10.4314/ahs.v18i2.15 · Cited by 2
Hepatic steatosis and fibrosis: evaluation with CT imaging
Hyodo, T., Yada, N., Maenishi, O., Matsuki, M., & Murakami, T. (2018) · Kanzo · doi:10.2957/kanzo.59.393 · Cited by 2
Electromyographic Analysis of Shoulder Girdle Muscles in Volleyball Throw: A Reliability Study
Zandi, S., Rajabi, R., Bandpei, M. A. M., & Minoonejad, H. (2018) · Biomedical Human Kinetics · doi:10.1515/bhk-2018-0021 · Cited by 2
Screening for thoracic aortic pathology: Clinical practice in a single tertiary center
Bons, L. R., de Assis, L. U., Dekker, S., Kauling, R. M., Cuypers, J. A. A. E., Verhagen, H. J. M., Budde, R. P. J., & Roos‐Hesselink, J. W. (2018) · Congenital Heart Disease · doi:10.1111/chd.12663 · Cited by 2
Effect of aging on pulse rate variability for evaluating autonomic nervous system
Yoshida, K., Takano, K., Hatanaka, M., Kashibayashi, T., Kakigi, T., & Kato, J. (2018) · Journal of medical technology · doi:10.14932/jamt.17-112 · Cited by 2
Grillo, E. U. (2018) · Logopedics Phoniatrics Vocology · doi:10.1080/14015439.2018.1545866 · Cited by 3
Spectral Repeatability of a Hyperspectral System for Human Iris Imaging
Cecilia, L. D., Marazzi, F., & Rovati, L. L. (2018) · IEEE International Forum on Research and Technology for Society and Industry (RTSI) · doi:10.1109/rtsi.2018.8548513 · Cited by 2
Anesthesia depth monitoring using alternative placement of entropy sensors: a prospective study
Иосифович, В. Д., Akselrod, B. A., Гуськов, Д. А., & Goncharova, A. V. (2018) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-018-00238-z · Cited by 2
PESA: Probabilistic Efficient Storage Algorithm for Time-Domain Spectrum Measurements
Kalaa, M. O. A., Ghanem, M., Refai, H. H., & Seidman, S. J. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2851678 · Cited by 2
Campo, A., McGarry, M., Panis, T., Dirckx, J., & Konofagou, E. E. (2019) · Journal of Biomechanical Engineering · doi:10.1115/1.4042435 · Cited by 2
Preliminary Evaluation of a Mobile Device for Dark Adaptation Measurement
Pundlik, S. J., & Luo, G. (2019) · Translational Vision Science & Technology · doi:10.1167/tvst.8.1.11 · Cited by 3
Aptidão cardiorrespiratória em crianças e adolescentes
Batista, K. R. D. O., de Oliveira, M. G. D., Lemos, C. F. D. S., Couto, J. D. O., Soares, N. M. M., & Silva, R. J. D. S. (2019) · Brazilian Journal of Kinanthropometry and Human Performance · doi:10.5007/1980-0037.2018v20n6p535 · Cited by 4
Moreira, S. R., Gurjão, A. L. D., Costa, F. L. D. O., Araújo, F. D. S., Simões, H. G., & de Moraes, J. F. V. N. (2019) · Revista Andaluza de Medicina del Deporte · doi:10.33155/j.ramd.2017.10.003 · Cited by 2
Coward, T. J., Richards, R., Fenlon, M. R., & Scott, B. (2019) · Journal of Prosthodontics · doi:10.1111/jopr.13041 · Cited by 2
Taremwa, I. M., Ndeze, I., Mwambi, B., Atuhairwe, C., Achieng, D. I., & Natukunda, B. (2019) · Journal of Blood Medicine · doi:10.2147/jbm.s188302 · Cited by 3
Yang, J., Nikanjam, M., Capparelli, E. V., Tsunoda, S. M., Greenberg, H. E., Penzak, S. R., Stoch, S. A., Bertino, J., Nafziger, A. N., & JOSEPH, D. R. (2019) · The Journal of Clinical Pharmacology · doi:10.1002/jcph.1440 · Cited by 2
Neirynck, J., Proost, R., & Campenhout, A. V. (2019) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-019-2746-2 · Cited by 2
Maximal Sustained Isokinetic Power at Exercise Intolerance is not Critical Power
Yong, S., Swisher, A. R., Ferguson, C., & Cannon, D. T. (2019) · International Journal of Sports Medicine · doi:10.1055/a-0946-1974 · Cited by 3
Rojas‐Gualdrón, D. F., Hernández, J. M. A., Arango, D. C., Cardona, Á. M. S., & Duque, M. O. G. (2019) · Revista Facultad Nacional de Salud Pública · doi:10.17533/udea.rfnsp.v37n2a10 · Cited by 3
Surawech, C., & Sasiwimonphan, K. (2019) · BJR|Open · doi:10.1259/bjro.20190025 · Cited by 2
Validation of a widely used heart rate monitor to track steps in older adults
Ruediger, S. L., on behalf of the NeuroExercise Study Group, Stuckenschneider, T., Abeln, V., Askew, C. D., Wollseiffen, P., & Schneider, S. (2019) · The Journal of Sports Medicine and Physical Fitness · doi:10.23736/s0022-4707.19.09830-x · Cited by 2
Irvine, K. L., Mans, C., & Friedrichs, K. R. (2019) · Journal of Avian Medicine and Surgery · doi:10.1647/2018-374 · Cited by 2
Effects of Cross-Clamping on Vascular Mechanics: Comparing Waveform Analysis With a Numerical Model
Politi, M. T., Ventre, J., Fernández, J. M., Ghigo, A., Gaudric, J., Armentano, R. L., Capurro, C., & Lagrée, P. (2019) · Journal of Surgical Research · doi:10.1016/j.jss.2019.08.009 · Cited by 2
Validity of Formulas Used for Estimation of One Repetition Maximum Strength in Young Men
Hazır, T., Esatbeyoğlu, F., Ekinci, Y. E., & İŞLER, A. K. (2019) · Turkiye Klinikleri Journal of Sports Sciences · doi:10.5336/sportsci.2019-70546 · Cited by 2
Ali, S. H. M., Omar, N., Shafie, M. S., Ismail, N. A. N., Hadi, H., & Nor, F. M. (2019) · Egyptian Journal of Forensic Sciences · doi:10.1186/s41935-019-0163-1 · Cited by 2
Reproducibility and criterion validity of data derived from a flywheel resistance exercise system
Spudić, D., Kambič, T., Cvitkovič, R., & Pori, P. (2019) · Isokinetics and Exercise Science · doi:10.3233/ies-194169 · Cited by 3
Three-wavelength optoelectronic system for hemodialysis monitoring
Коноплев, Г., Stepanova, O. S., Frorip, A., & Gerasimchuk, R. P. (2019) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1400/6/066043 · Cited by 2
Linear Regression Models for Total Body Water Measurement Based on Bioelectrical Impedance Analysis
Khatun, F., Raña, M. S., & Sarkar, A. K. (2019) · International Conference on Advances in Science, Engineering and Robotics Technology (ICASERT) · doi:10.1109/icasert.2019.8934698 · Cited by 2
Yang, S., Zeng, L., ZHAO, Q. P., Zen, Z.-P., Li, A., Zhang, L.-W., Li, L., Song, N., Liu, Y., & Zhang, H. (2020) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000001141 · Cited by 2
Internal tibial torsion is related to syndesmosis injury in a large osteological collection
McCarthy, C. F., Weinberg, D. S., & Liu, R. W. (2020) · Foot and Ankle Surgery · doi:10.1016/j.fas.2020.01.001 · Cited by 2
Evaluating a pragmatic estimate of insulin sensitivity in Latino youth with obesity
Peña, A., Olson, M. L., Soltero, E. G., Lee, C. D., Toledo, M. J. L., Ayers, S. L., & Shaibi, G. Q. (2020) · Clinical Obesity · doi:10.1111/cob.12353 · Cited by 2
Analgesic trials in neonates: observations, pitfalls and recommendations.
van Dijk, M., Tibboel, D., van den Anker, J. N., & Simons, S. H. P. (2005) · Paediatric and Perinatal Drug Therapy · Cited by 2
Belvedere, S., Gouil, Q. A., Thompson, C., & Solomon, J. (2020) · Vascular and Endovascular Surgery · doi:10.1177/1538574420906945 · Cited by 2
Change of bio-electric interferential currents of acute fatigue and recovery in male sprinters
Tan, Y., Liu, Y., Ye, R., Xu, H., Nie, W., Lü, J., Zhang, B., Wang, C., & He, B. (2020) · Sports Medicine and Health Science · doi:10.1016/j.smhs.2020.02.004 · Cited by 2
Pazzaglia, U. E., Reguzzoni, M., Depero, L. E., Federici, S., Bondioni, M. P., Zarattini, G., & Raspanti, M. (2020) · Microscopy Research and Technique · doi:10.1002/jemt.23477 · Cited by 2
Jaker, S., Burgan, A., Prakash, V., Birkinshaw, A., Moosai, K., Jacques, A. M., Fluck, D. S., MacGregor, M., Lazariashvili, O., Sharma, P., et al. (2020) · JRSM Cardiovascular Disease · doi:10.1177/2048004020915393 · Cited by 2
Ober, R. A., & Geist, G. E. (2020) · Journal of the American Association for Laboratory Animal Science · doi:10.30802/aalas-jaalas-19-000140 · Cited by 5
Savakus, J. C., Weinberg, D. S., Moore, T. A., & Vallier, H. A. (2020) · JAAOS Global Research and Reviews · doi:10.5435/jaaosglobal-d-19-00093 · Cited by 2
Leonardi, B., D’Avenio, G., Vitanovski, D., Grigioni, M., Perrone, M. A., Romeo, F., Secinaro, A., Everett, A. D., & Pongiglione, G. (2020) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000965 · Cited by 2
ESTIMATION OF PLATELET COUNT ON THE BASIS OF RED CELL: PLATELET RATIO
Abid, B. F. (2009) · Iraqi journal of Medical Sciences · Cited by 2
Malladi, A., Battapady, H. D., Hampton, R. M., & Jing, S. (2020) · Scientia Horticulturae · doi:10.1016/j.scienta.2020.109474 · Cited by 2
Relative Ectopic Kidney Function Quantification Using DMSA Tomoscintigraphy Modality
Njeh, I., Chtourou, K., & Hamida, A. B. (2020) · Journal of Healthcare Engineering · doi:10.1155/2020/6092305 · Cited by 2
Using a Crossline Laser to Predict Peak Plantar Pressure During Walking
Donovan, L., Torp, D. M., & Thomas, A. C. (2020) · Journal of Athletic Training · doi:10.4085/1062-6050-307-19 · Cited by 2
Uryga, A., Kaczmarska, K., Burzyńska, M., Czosnyka, M., & Kasprowicz, M. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab9bb6 · Cited by 2
Spiral electrode for continuous fetal heart rate monitoring during in-utero myelomeningocele repair
Segura, L. G., Arendt, K. W., Sviggum, H. P., Haider, C. R., Qureshi, M. Y., Weingarten, T. N., Johnson, J. N., & Ruano, R. (2020) · International Journal of Obstetric Anesthesia · doi:10.1016/j.ijoa.2020.06.004 · Cited by 2
Beyer, B., Michaud, A., Oliver, T., Feipel, V., & Dugailly, P.-M. (2020) · Musculoskeletal Science and Practice · doi:10.1016/j.msksp.2020.102217 · Cited by 2
Takahashi, R., Sano, K., Kimura, K., Ishioka, T., Suzuki, M., Nakaya, N., Ozeki, S., & Hamaguchi, T. (2020) · Medicine · doi:10.1097/md.0000000000021889 · Cited by 2
Sajid, S., Kuiper, J. H., Dhawan, R., Banerjee, R., & Lewthwaite, S. (2020) · Journal of Clinical Orthopaedics and Trauma · doi:10.1016/j.jcot.2020.08.001 · Cited by 2
Radiographic goniometry of the PIP-joint: A reliable measurement method
Verhaegen, P. D. H. M., Kemper, L. T., Brink, S. M., & de Jong, T. R. (2020) · Journal of Hand Therapy · doi:10.1016/j.jht.2020.08.002 · Cited by 2
Segmentation-Free Estimation of Aortic Diameters from MRI Using Deep Learning
Aguerreberry, A., de la Rosa, E., Lalande, A., & Fernández, E. A. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-68107-4_17 · Cited by 2
Okwose, N. C., Bouzas‐Cruz, N., Fernández, Ó. G., Koshy, A. O., Green, T., Woods, A., Robinson-Smith, N., Tovey, S., McDiarmid, A. K., Parry, G., et al. (2020) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2020.09.479 · Cited by 2
Graded and ramp protocols present similar results in apparently healthy subjects
Lima, T. B., Santos, T. M., Damasceno, V. D. O., & Campos, E. Z. (2020) · Brazilian Journal of Kinanthropometry and Human Performance · doi:10.1590/1980-0037.2020v22e57565 · Cited by 2
Song, K., Xu, Q., Koenig, H. M., Kong, M., Slaughter, M. S., Huang, Y., Clifford, S. P., & Huang, J. (2020) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2020.10.043 · Cited by 4
Kauser, F., Amitava, A. K., Saxena, J., Raza, S., Masood, A., & Alam, M. (2020) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_2391_19 · Cited by 2
Appraising the Validity of Tools to Measure Multijoint Leg Power: A Systematic Review
Trivedi, P., Gilbert, R. W., & Dechman, G. (2020) · Archives of Rehabilitation Research and Clinical Translation · doi:10.1016/j.arrct.2020.100099 · Cited by 3
Characterization of posterior corneal astigmatism in a population with keratoconus
Marques, R., Guerra, P. S., Quintas, A. M., & Rodrigues, W. (2020) · Seminars in Ophthalmology · doi:10.1080/08820538.2020.1863436 · Cited by 2
Athavale, N. A., Mahapure, S., Shyam, A. K., Sancheti, P., Nirgude, A., & Bhore, N. (2021) · Indian Journal of Health Sciences and Biomedical Research (KLEU) · doi:10.4103/kleuhsj.kleuhsj_63_20 · Cited by 2
Braun, T., Marks, D., Thiel, C., & Grüneberg, C. (2021) · BMC Neurology · doi:10.1186/s12883-021-02327-0 · Cited by 2
A Novel Fast Searching Algorithm Based on Least Square Regression
Challa, R. K., Chintha, S. P., Reddaiah, B., & Rao, K. S. (2021) · Revue d intelligence artificielle · doi:10.18280/ria.350111 · Cited by 2
Prospective comparison of thermometers used in very preterm infants
Dunne, E. A., O’Donnell, C. P. F., & McCarthy, L. K. (2021) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/archdischild-2020-321342 · Cited by 2
Performance of allergen testing in a survey of frozen meals and meals ready-to-eat (MREs)
Shelver, W. L., McGarvey, A. M., & Yeater, K. M. (2021) · Food Additives & Contaminants Part A · doi:10.1080/19440049.2021.1914870 · Cited by 2
Ye, W., Hackett, S., Vandevelde, C., Twigg, S., Helliwell, P., & Coates, L. C. (2021) · The Journal of Rheumatology · doi:10.3899/jrheum.200927 · Cited by 2
Tayyem, R., Albataineh, S. R., Allehdan, S., & Badran, E. (2021) · Nutrición Hospitalaria · doi:10.20960/nh.03528 · Cited by 3
The “Shiny and Thick High Heel Sign”
Schacht, H., König, I. R., Hensler, J., Schramm, P., Küchler, J. N., Ditz, C., & Neumann, A. (2021) · Clinical Neuroradiology · doi:10.1007/s00062-021-01036-y · Cited by 2
Reference Intervals of Fetal Cardiac Volume Between 14 and 40 Weeks of Gestation
Thammavong, K., Luewan, S., & Tongsong, T. (2021) · Journal of Ultrasound in Medicine · doi:10.1002/jum.15768 · Cited by 2
Do heart rate variability is relationed to endurance performance in female futsal players?
Pinto, J. C. B. D. L., Medeiros, R. M. V., Mortatti, A. L., Nakamura, F. Y., Fortes, L. D. S., Machado, D. G. D. S., & Fonteles, A. I. (2021) · Brazilian Journal of Kinanthropometry and Human Performance · doi:10.1590/1980-0037.2021v23e73799 · Cited by 5
Bugeja, J. M., Chandra, S. S., Neubert, A., Fripp, J., Lockard, C. A., Ho, C. P., Crozier, ., & ENGSTROM, C. M. (2021) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2021.06.008 · Cited by 2
Pham, K. V. (2021) · Applied Sciences · doi:10.3390/app11146599 · Cited by 2
Ankrah, J. (2021) · Journal of Geography Environment and Earth Science International · doi:10.9734/jgeesi/2021/v25i630292 · Cited by 2
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.