STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 41,201–41,300 of 47,868
Gönen, T., & Usgu, S. (2025) · Turkish Journal of Sports Medicine · doi:10.47447/tjsm.0883 · Cited by 1
HRV‐Based Thresholds in Rowing: Validity and Reliability Assessment
Held, S., Rappelt, L., Wiedenmann, T., Rommelmann, J., Gronwald, T., & Donath, L. (2025) · European Journal of Sport Science · doi:10.1002/ejsc.70054 · Cited by 4
Influence of stainless-steel orthodontic brackets on the tomographic planning of dental implants
Maracci, L. M., Barbosa, G. F., Savegnago, G. D. O., de Mello, W. M., Marquezan, M., & Liedke, G. S. (2025) · Brazilian journal of oral sciences/Brazilian Journal of Oral Sciences · doi:10.20396/bjos.v24i00.8677114 · Cited by 1
van der Meulen, L. R., van Dinther, M., Chiribiri, A., Smink, J., CRUCIAL Investigators, Backes, W. H., Bennett, J. B., Wildberger, J. E., Scannell, C. M., & Holtackers, R. J. (2025) · Diagnostics · doi:10.3390/diagnostics15182341 · Cited by 1
Polat, H., Kırmacı, Z. İ. K., Uzun, M., Fırat, Y. E., Erel, S., & Neyal, A. M. (2025) · Multiple Sclerosis and Related Disorders · doi:10.1016/j.msard.2025.106773 · Cited by 1
Musso, M., Bai, S., & Oliveira, A. S. (2025) · Wearable Technologies · doi:10.1017/wtc.2025.10026 · Cited by 3
Actigraphy and diary-assessed sleep in first-trimester pregnant women: A Bland-Altman analysis
Tsai, S., Lee, P., Gordon, C. J., Kuo, S., & Lee, C. (2025) · Sleep Medicine · doi:10.1016/j.sleep.2025.106831 · Cited by 2
Benke, B., John, M. T., Szentpétery, A., & Marada, G. (2025) · Dentistry Journal · doi:10.3390/dj13100444 · Cited by 1
Validation of a new textile sensor band for on-farm heart rate variability assessment in calves
Turini, L., Rossi, G. P., Sala, G., Foggi, G., Gislon, G., Mondini, S., Barbieri, S., Calonaci, S., Canali, E., Bonelli, F., et al. (2025) · Veterinary Quarterly · doi:10.1080/01652176.2025.2569550 · Cited by 1
Nordlie, E., Elander, J., Värendh, M., Stenfeldt, K., Tjernström, F., Gisselsson‐Solén, M., Sjögren, J., Magnusson, M., & Ehinger, J. K. (2025) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-025-09675-4 · Cited by 1
Harifidy, R. Z., Ishidaira, H., Magome, J., & Souma, K. (2025) · Climatic Change · doi:10.1007/s10584-025-04003-5 · Cited by 1
Nourrisson, C., Varlet‐Marie, E., Guitard, J., Guegan, H., Nabet, C., Ménotti, J., Pelloux, H., Brenier‐Pinchart, M., & Sterkers, Y. (2025) · Journal of Clinical Microbiology · doi:10.1128/jcm.00538-25 · Cited by 1
Predictors of lower-limb arterial occlusion pressure across commonly used cuff widths
Wedig, I. J., Lennox, I. M., Petushek, E. J., Durocher, J. J., McDaniel, J., & Elmer, S. J. (2025) · Frontiers in Physiology · doi:10.3389/fphys.2025.1658744 · Cited by 4
Caña-Pino, A., & Marín-Rubio, A. (2025) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk10040416 · Cited by 1
Assessing the accuracy of predicted values of human CO2 generation rates for IAQ applications
Oke, O., Fernández‐Verdejo, R., Lowe, A. C., Watson, L. P. E., Chen, S., Flagner, S., Plasqui, G., & Persily, A. K. (2025) · Indoor Environments · doi:10.1016/j.indenv.2025.100132 · Cited by 2
Hassen, S. B., Hammami, R., Negra, Y., Sammoud, S., & van den Tillaar, R. (2025) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk10040417 · Cited by 2
Rata, M., Tunariu, N., Jiang, Y., Hughes, J. C., Hopkinson, G., Scurr, E. D., Winfield, J. M., Gulani, V., Koh, D., & Orton, M. R. (2025) · European Radiology · doi:10.1007/s00330-025-12071-5 · Cited by 1
Koos, A., Milani, R. V., Velasco‐Gonzalez, C., Morin, D. P., & Bober, R. (2025) · European Heart Journal - Imaging Methods and Practice · doi:10.1093/ehjimp/qyaf132 · Cited by 1
Pathological and radiological evaluation of ureteral wall thickness measurement in urolithiasis
O’Meara, S., Rohan, P., Cullivan, O., O’Brien, F. J., O’Shea, A., & Davis, N. F. (2025) · Urolithiasis · doi:10.1007/s00240-025-01879-x · Cited by 1
Jha, P., Birring, S. S., Sehgal, I. S., Muthu, V., Dhooria, S., Prasad, K. T., Aggarwal, A. N., & Agarwal, R. (2025) · The Journal of Allergy and Clinical Immunology In Practice · doi:10.1016/j.jaip.2025.10.028 · Cited by 1
Cluster trimming: Improving segment homogeneity in product testing with consumers
Jaeger, S. R., MacFie, H. J. H., Lawlor, J., Fillion, L., Antille, N., Rytz, A., & Hasted, A. M. (2025) · Food Quality and Preference · doi:10.1016/j.foodqual.2025.105782 · Cited by 1
Vannier, C., Guézais, A., Talbot, M., Faucheur, A. L., & Mahé, G. (2025) · Vascular Medicine · doi:10.1177/1358863x251379810 · Cited by 1
Szczepan, S., Pożarowszczyk-Kuczko, B., & Michalik, K. (2025) · Scientific Reports · doi:10.1038/s41598-025-23633-4 · Cited by 1
ODABAŞIOĞLU, M. E., Kasırga, Z., & Kanter, A. G. (2025) · Journal of Back and Musculoskeletal Rehabilitation · doi:10.1177/10538127251395837 · Cited by 1
Denk, M. C., Bertin, M., Donadono, V., Kangesu, L., Yulia, A., Ushakov, F. B., Pandya, P. P., & Napolitano, R. (2025) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.70137 · Cited by 1
Gesto, C. D., Spinoni, M., & Grano, C. (2025) · Healthcare · doi:10.3390/healthcare13222993 · Cited by 1
Park, K.-M., Lee, D., Lee, J., Beom, J., & Lee, S. J. (2025) · Biomedical Engineering Letters · doi:10.1007/s13534-025-00534-z · Cited by 1
Kumar, A., Karmakar, S., Giddaluru, S. G., Singh, P., Lin, K., Muthukumar, S., & Prasad, S. (2025) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2025.100715 · Cited by 1
Mesnage, M., Massot, B., Blanchard, M., Raimbaud, P., & Lavoué, G. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11252930 · Cited by 1
Dauvergne, J. E., Lakhal, K., & Boulain, T. (2025) · Systematic Reviews · doi:10.1186/s13643-025-03009-5 · Cited by 1
Hileghem, L. V., Vloemans, D., Dosso, F. D., Pollet, F., Verbist, W., Thomas, D., Vermeire, S., & Lammertyn, J. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c05535 · Cited by 2
Deuren, T. V., Decorte, T., Catteeuw, P., Latré, S., & Verdonck, T. (2025) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2024-0537 · Cited by 1
Validity and reliability of an inertial measurement unit to assess jump performance
Saini, P., Suresh, A., Nair, S., Bădicu, G., Ramírez‐Campillo, R., & Thapa, R. K. (2025) · Proceedings of the Institution of Mechanical Engineers Part P Journal of Sports Engineering and Technology · doi:10.1177/17543371251395819 · Cited by 1
Singh, M., Moaddab, A., Shin, D., Weber, J., Chau, K., Dakroub, A. H., Parikh, R., Pipitone, K., Ali, Z. A., & Khalique, O. K. (2025) · Tomography · doi:10.3390/tomography11120139 · Cited by 1
Psychometric properties of Turkish ChatGPT usage and attitudes scales in nursing students
Ceylan, H., & Yangöz, Ş. T. (2025) · Teaching and learning in nursing · doi:10.1016/j.teln.2025.11.024 · Cited by 1
Enhancing public health through ocean research—a model for global partnership
Piccioli, A., Lucentini, L., Muratore, A., Risoluti, R., Briancesco, R., Rosa, G. L., Notargiacomo, L., Mattei, G., Mattei, D., Gregorio, F. N. D., et al. (2025) · Frontiers in Climate · doi:10.3389/fclim.2025.1670665 · Cited by 1
Dia, I., Sy, B., Diagne, O., Mané, S., & Diouf, L. (2025) · Mining · doi:10.3390/mining5040084 · Cited by 1
Łabieniec, Ł., Szymański, K. R., Andrejczuk, A., Spyridonidis, T., Filis, K., & Apostolopoulos, D. J. (2025) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2025.102607 · Cited by 2
Yamauchi, H., Ando, M., Ino, K., Tsukihara, H., Aoyama, G., Sakuma, I., & Ono, M. (2025) · JTCVS Techniques · doi:10.1016/j.xjtc.2025.11.007 · Cited by 1
Mulligan, D. J., & Milner, C. E. (2025) · PLoS ONE · doi:10.1371/journal.pone.0339481 · Cited by 1
Diagnostic accuracy of echocardiography in identifying heart failure related pleural effusions
Sah, A., Derakhshesh, M., Bozell, H. D., WASIM, M., Javed, F., Kirkpatrick, P., Corona, E. F., Shkolnik, B., Feustel, P. J., Hu, K., et al. (2025) · Respiratory Medicine · doi:10.1016/j.rmed.2025.108627 · Cited by 1
Synchronization of OpenCap with Force Platforms: Validation of an Event-Based Algorithm
Vivas, M. I. P., Arturo, D., Peñuela-Arango, S., Quiñones-Preciado, J. A., & Gómez-Salazar, L. (2026) · Italian National Conference on Sensors · doi:10.3390/s26020360 · Cited by 2
M-ECG: extracting heart signals with a novel computational analysis of magnetoencephalography data
Izadysadr, A., Bagherzadeh, H. S., Stapleton-Kotloski, J. R., Popli, G., O’Donovan, C. A., & Godwin, D. W. (2026) · Frontiers in Neuroimaging · doi:10.3389/fnimg.2025.1675960 · Cited by 1
Sekkat, H., Khallouqi, A., Mouden, O. E., Bannan, A., Berrada, Y., Halimi, A., Madkouri, Y., & Rhazouani, O. E. (2026) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2026.113633 · Cited by 1
Cui, C., Hartanto, H., Yin, X., Li, J., LUK, C. W., Szeto, C. C., & Chen, T.-H. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.118400 · Cited by 1
Fukunaga, M., Ichikawa, S., Ichijiri, K., Ito, O., Moriya, T., & Yamaguchi, Y. (2026) · Radiological Physics and Technology · doi:10.1007/s12194-025-00995-y · Cited by 1
Comparison of prolonged exhalation end-tidal CO₂ and transcutaneous CO₂ monitoring in COPD patients
Zha, S., He, Z., Niu, J., Huang, Q., Liang, Z., Zhou, Z., Yang, H., Lin, S., Guan, L., Zhou, L., et al. (2026) · Critical Care · doi:10.1186/s13054-025-05834-5 · Cited by 1
Mortezaee, M., Shamsi, H., Eslami, A., & Naeini, S. A. (2026) · Results in Engineering · doi:10.1016/j.rineng.2026.109112 · Cited by 1
Ahn, Y., Lee, G. D., Choi, S., Kim, H. R., Kim, Y., Kim, D. K., Park, S.-I., Choe, J., & Yun, J. K. (2026) · Lung Cancer · doi:10.1016/j.lungcan.2026.108934 · Cited by 1
Wearable Biosensors and AI Analytics for Continuous Health Monitoring and Early Disease Detection
Mohmmed, H. A. (2024) · Academic International Journal of Engineering Science · doi:10.59675/e225 · Cited by 1
Oliva, P. J., Ghosh, S., Huang, F., Wiebe, E. M., Cuartero, J., Ghosh, S. S., Boulanger, P., Yun, J., Punithakumar, K., & Menon, G. (2026) · Brachytherapy · doi:10.1016/j.brachy.2025.12.007 · Cited by 1
Jiao, Y. (2026) · Sensor Review · doi:10.1108/sr-08-2025-0630 · Cited by 2
Xu, Z., Song, H., Huang, H., Fu, M., Tang, Y., Zhang, P., Zhang, G., & Li, J. (2026) · European Urology Open Science · doi:10.1016/j.euros.2026.01.003 · Cited by 2
Tanaka, S., Ohba, N., Saito, N., Tanaka, K., Ishimoto, Y., Ochi, K., Yasui, K., Fujita, M., Abe, K., & Takahashi, S. (2026) · Journal of Medical Ultrasonics · doi:10.1007/s10396-025-01612-6 · Cited by 2
Abdullahi, S. S., Ali, M., Kashif, U. A., Hassan, F., Li, J., Yuhang, L., Omer, M. O. M., Chen, K., & Nie, Z. (2026) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2026.3657796 · Cited by 1
Beyond CT: Attenuation correction for stand-alone brain PET
Jehl, M., Bonta, M. J., Mikhaylova, E., Ahnen, M. L., Cherry, S. R., Sacco, I., & Fischer, J. (2026) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2026.02.001 · Cited by 2
Cavallo, M., Ricchi, M., Axford, A., Yeung, K., McGing, J., Brizi, L., Tyler, D. J., Testa, C. M., & Grist, J. T. (2026) · Scientific Reports · doi:10.1038/s41598-026-38964-z · Cited by 1
[Translated article] It's possible to know tibial torsion in a X ray of the limbs?
González-Herranz, P., & Penelas-Abelleira, N. (2026) · Revista Española de Cirugía Ortopédica y Traumatología · doi:10.1016/j.recot.2026.02.014 · Cited by 1
Ramesh, J., Loney, T., du Plessis, S. S., Rivas, H., Sagahyroon, A. A., Aloul, F., & Boillat, T. (2026) · Sensors · doi:10.3390/s26041295 · Cited by 2
Khaled, O., Mahmoud, H. A., Ryad, L., Medhat, M., El-Sawi, S., Gamal, A., & Eissa, F. (2026) · Journal of Chromatography B · doi:10.1016/j.jchromb.2026.124979 · Cited by 1
Capnodynamic Cardiac Output Assessment in a Porcine Model of Aorto-pulmonary Shunt
Hedov, J., Svedmyr, A., Wallin, M. K. E. B., Hallbäck, M., Lönnqvist, P., & Karlsson, J. (2026) · Anesthesiology · doi:10.1097/aln.0000000000006012 · Cited by 1
Xu, Z. (2026) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2026.106803 · Cited by 1
Churcher, N. K. M., Rizvi, F. Z., Qureshi, A., Aziz, S., Madhurantakam, S., Ayisi‐Boateng, N. K., Adankwah, E., Ansah, M. K., Phillips, R. O., & Prasad, S. (2026) · npj Biosensing · doi:10.1038/s44328-026-00081-2 · Cited by 2
Nishioka, T., Yamaguchi, S., Hajima, D., & Inami, T. (2026) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2026.2638275 · Cited by 1
Muzyka−Woźniak, M., Kaminska, I., Piwowarczyk, P., & Szczęsna-Iskander, D. H. (2026) · Clinical ophthalmology · doi:10.2147/opth.s571059 · Cited by 1
López, J. J., & Banchero, L. (2026) · International Conference on Intelligent Control and Information Processing · doi:10.1109/icicip67436.2026.11417658 · Cited by 1
Jiang, Y., Xie, Z., Zhang, L., Li, Y., & Lyu, Y. (2026) · Soil Dynamics and Earthquake Engineering · doi:10.1016/j.soildyn.2026.110274 · Cited by 1
Wang, Y., Alexander, C. M., & Strutton, P. H. (2026) · Scientific Reports · doi:10.1038/s41598-026-45536-8 · Cited by 1
Nascimento, E. M. F., Borszcz, F. K., Ventura, T. P., Antunes, D., Guglielmo, L. G. A., & de Lucas, R. D. (2026) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2026.2645354 · Cited by 1
Rutten, C., Fisher, Y., Shannon, P. T., Pai, V., Krishnan, P., Shinar, S., & Miller, E. (2026) · Pediatric Radiology · doi:10.1007/s00247-026-06592-4 · Cited by 1
Ghazzagh, A., Niknam, A., & Shahrbanian, S. (2026) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-026-01616-w · Cited by 1
Abdul‐Kadir, M., Shafit, M. A. M., Salam, A., & Kamal, K. M. (2026) · BMC Ophthalmology · doi:10.1186/s12886-026-04730-y · Cited by 1
Bacchetti, A., McCormack, B., Lin, T., Filippatou, A. G., Gakis, G., Pellegrini, N., Kinder, E., Gulati, A., Lievers, E., Otero-Duran, G., et al. (2026) · Multiple Sclerosis Journal · doi:10.1177/13524585261426768 · Cited by 1
Reproducibility and validity of healthy dietary indices derived from 24-hour dietary recalls
Li, M., Sun, G., Han, Y., Xu, H., Zhang, J., Wang, T., Lyu, Y., Cao, H., Li, X., Ma, X., et al. (2026) · Frontiers in Nutrition · doi:10.3389/fnut.2026.1730154 · Cited by 2
Arafat, A. A., Awad, A. K., Albabtain, M. A., Alotaibi, H. F., Alqussayer, S. A., Altunusi, F., Adel, M. E., & Gumaa, M. (2026) · The Cardiothoracic Surgeon · doi:10.1186/s43057-026-00196-2 · Cited by 1
The Dependency of LogMAR Visual Acuity Measurements on Chart Design and Scoring Rule
Hazel, C. A., & Elliott, D. B. (2002) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2002.tb01580.x · Cited by 1
Thomann, B., Fechter, T., Fischer, J., Runz, A., Ludwig, U., Sachpazidis, I., Blanck, O., Roers, J., Grehn, M., Grohmann, M., et al. (2026) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2026.03.055 · Cited by 1
Accurate quantification of polyester in textiles through complete depolymerisation and HPLC
Cerri, M., Pitkänen, L., Schutgens, C., & Hummel, M. (2026) · Analytical Methods · doi:10.1039/d6ay00086j · Cited by 1
Wu, J., Dimagiba, E., Zhao, A., Ahmed, M., Yu, X., Yan, J., Zhang, Y., Lorenzo, K., Cham, H., & Yip, T. (2026) · Sleep Science and Practice · doi:10.1186/s41606-026-00188-5 · Cited by 1
Zhang, M., Sun, L., Lin, C., Yu, X., Shi, Y., & Fan, Z. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1794158 · Cited by 1
Pan, Z., Hu, M., Zhou, J., Wang, Y., Pan, Y., Wu, H., Du, J., Ma, L., Zeng, L., & Chen, D. (2026) · Water Research · doi:10.1016/j.watres.2026.126026 · Cited by 1
Combined trochleoplasty and medial patellofemoral ligament reconstruction reduces patellar height
Riechelmann, F., Schaufler, A., Gasser, N., Nardelli, P., Arora, R., & Hackl, W. (2026) · Journal of Experimental Orthopaedics · doi:10.1002/jeo2.70742 · Cited by 1
Nishioka, T., Yamaguchi, S., Hajima, D., Yabuno, N., Aoki, A., Kunita, Y., Hashimoto, Y., & Inami, T. (2026) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000005422 · Cited by 1
Opperman, T., Patel, R., Chiong, J. D., Stewart, D. J., & Nasser, A. (2026) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djag146 · Cited by 1
Clinical Validation of Two New Planimetric Techniques for Measuring Ulcer Surface Area
Foltyński, P., Rosiński, G., & Ładyżyński, P. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968261449261 · Cited by 1
Katsumata, T., Shimizu, K., Suzuki, N., Miura, T., Miyagi, M., Miura, H., Xinze, W., Park, U., Yamamoto, K., & Ebihara, S. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.1769921 · Cited by 1
Hybrid motion–measurement control and traceable HMI for a 3-PSP manipulator
Rugbani, A., & Agll, A. (2026) · Industrial Robot the international journal of robotics research and application · doi:10.1108/ir-10-2025-0358 · Cited by 1
Stiller, N., Schmidt, J., Meigen, C., Messerschmidt, A., Kieß, W., Vogel, M., Körner, A., Schulz‐Kornas, E., & Haak, R. (2026) · Clinical Oral Investigations · doi:10.1007/s00784-026-06939-z · Cited by 1
When posture matters: Investigating cuffless BP estimation errors across postural changes
Lai, J. C. Y., Kar, P., & Maulik, U. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.110685 · Cited by 1
Korkan, Ü., Pekdemir, M., Özturan, İ. U., Doğan, N. Ö., Yaka, E., & Yılmaz, S. (2026) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2026.06.011 · Cited by 2
Hu, H., Yu, Z., Qin, F., & Yang, F. (2026) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2026.1856637 · Cited by 2
Setup reproducibility of the semi-Fowler’s position in radiotherapy: a practical feasibility study
Park, S., 김태규, Choi, J. O., Jeong, C., Park, S., Cho, J., Lim, H., & Kim, J. (2026) · Journal of Radiotherapy in Practice · doi:10.1017/s146039692610048x · Cited by 1
Are there age-related differences in glycaemic response and glycaemic index?
Wolever, T. M. S., & Zurbau, A. (2026) · European Journal of Clinical Nutrition · doi:10.1038/s41430-026-01773-8 · Cited by 1
Mavrych, V., Majeed, K. M. K., Alshehri, S. S., Yasmin, U., Kashif, M. R., Kashif, A., Mahdi, W., Talha, R., & Bolgova, O. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15124554 · Cited by 1
Kim, H., Lee, S.-T., & Lee, J. (2026) · Applied Sciences · doi:10.3390/app16125902 · Cited by 1
A Reflectance–based multimodal wearable photoplethysmography (PPG) sensor
Durbha, R., & Koomson, V. (2026) · Review of Scientific Instruments · doi:10.1063/5.0304023 · Cited by 1
Muscle Oxygen Saturation as a Marker of Internal Load in Elite Soccer: A Case Series
Herzog, S., Philippi, M., Feldmann, A., Asian, J., Fílter, A., Requena, B., Batterson, P. M., & Bogdanis, G. C. (2026) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000005483 · Cited by 1
Motamedi, B., Heiderscheidt, E., Tesfamariam, A. T., & Rossi, P. M. (2026) · Journal of Hydrology · doi:10.1016/j.jhydrol.2026.135936 · Cited by 1
Surkova, E., Gimelli, A., Giannopoulos, A. A., Marsan, N. A., Baggiano, A., Čikeš, M., Baritussio, A., Ramkisoensing, A. A., Dweck, M. R., González‐Del‐Hoyo, M., et al. (2026) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeag171 · Cited by 1
Wang, S., Niu, M., Feng, J., Li, Q., Wei, G., & Shi, P. (2026) · Soil and Tillage Research · doi:10.1016/j.still.2026.107361 · Cited by 1
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.