STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 40,801–40,900 of 47,868
Ambulatory Blood Pressure Monitoring
Östergren, J., & Isaksson, H. (1993) · Vascular Medicine Review · doi:10.1177/1358863x9300400203 · Cited by 2
Babalola, O., Goudge, J., Levin, J., Brown, C., & Griffiths, F. E. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2022.868252 · Cited by 3
Ribeiro, A. G. S. V., Crisp, A. H., Ravelli, M. N., de Oliveira, M. R. M., & Verlengia, R. (2022) · Journal of Sports Sciences · doi:10.1080/02640414.2022.2091346 · Cited by 4
Cordovil, K., Crivelli, M., Lima, L. C., Brito, F. D. S. B., & Fleury, M. K. (2022) · The North African Journal of Food and Nutrition Research · doi:10.51745/najfnr.6.14.94-106 · Cited by 2
Unsupervised Classification of Human Activity with Hidden Semi-Markov Models
Cavallo, F. R., Toumazou, C., & Nikolić, K. (2022) · Applied System Innovation · doi:10.3390/asi5040083 · Cited by 2
Rico-González, M., Arcos, A. L., Bastida‐Castillo, A., & Pino‐Ortega, J. (2022) · Revista Tecnología y Ciencia · doi:10.33414/rtyc.44.42-51.2022 · Cited by 2
Agreement of the Newly Developed Moyers' Equations and Moyers' Tables
Thiradilok, S., Witayabusarakhum, P., Manopatanakul, S., & Ho, C. T. C. (2022) · European Journal of Dentistry · doi:10.1055/s-0042-1749157 · Cited by 2
Cao, H., Sesselmann, S., Xu, J., Seehaus, F., & Forst, R. (2022) · Clinical Orthopaedics and Related Research · doi:10.1097/corr.0000000000002453 · Cited by 2
Jemaa, H. B., Sarra, K., Karmous, I., Henda, J., Kari, K. E., Aguenaou, H., Aouidet, A., & Mankaï, A. (2023) · African Health Sciences · doi:10.4314/ahs.v23i3.77 · Cited by 2
Balas-Nakash, M., Legorreta-Legorreta, J., Rodríguez-Cano, A. M., Aguilera-Pérez, R., & Perichart‐Perera, O. (2010) · PubMed · Cited by 4
Comparison of two different methods for the determination of erythrocyte sedimentation rate
Özdemir, Ş., Öztürk, G., Altuntaş, A., Akyol, S., Bulut, E., Erden, G., & Temel, İ. (2014) · Journal of Clinical and Experimental Investigations · doi:10.5799/ahinjs.01.2014.03.0422 · Cited by 2
Predicting time to exhaustion during high-intensity exercise using rating of perceived exertion
Okuno, N. M., Soares-Caldeira, L. F., Milanez, V. F., & Perandini, L. A. (2015) · Science & Sports · doi:10.1016/j.scispo.2015.05.003 · Cited by 3
Benitez-del-Castillo, J. M., Martinez, A., & Regi, T. (2011) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2011.02649.x · Cited by 2
Cloetens, L. (2009) · Cited by 6
Delport, E. (2007) · UpSpace Institutional Repository (University of Pretoria) · Cited by 2
Weißbach, W., & Wiesmüller, G. A. (2006) · RWTH Publications (RWTH Aachen) · Cited by 2
Quantification and Visualization of Cardiovascular Function using Ultrasound
Larsson, M. (2009) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 4
Halim, A. B., Khedr, B., Caprio, F., Mazzantini, M., & Donadio, C. (2007) · Springer eBooks · doi:10.1007/978-3-540-73841-1_198 · Cited by 2
Determinants and measurement of lean body mass in Indian adults
Kulkarni, B. (2014) · Cited by 2
Respiratory Inductive Plethysmography for Assessing Risk of Pulmonary Barotrauma
DALL'AVA-SANTUCCI, J., Brunet, F. P., & Dhainaut, J.-F. (1992) · Yearbook of intensive care and emergency medicine · doi:10.1007/978-3-642-84734-9_41 · Cited by 2
Kampa, N. (2006) · Epsilon Open Archive (Sveriges lantbruksuniversitet biblioteket (Swedish University of Agricultural Sciences)) · Cited by 2
Alternative Methods for Assessment of Split Renal Function
Björkman, H. (2008) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 2
Oat (Avena sativa L.) quality improvement for increased beta-glucan concentration
Newell, M. (2011) · Iowa State University Digital Repository (Iowa State University) · doi:10.31274/etd-180810-2763 · Cited by 4
Characterization of Glucose Metabolism
Mazze, R. S., APRN-BC, F. E. S. S., Bergenstal, R. M., Criego, A. B., Cuddihy, R. M., Langer, O., Simonson, G. D., & Powers, M. A. (2011) · Wiley eBooks · doi:10.1002/9781119950424.ch3 · Cited by 2
Validation and calibration of self-report methods: the Youth Activity Profile
Maduro, P. F. D. S.-M. (2013) · Iowa State University Digital Repository (Iowa State University) · doi:10.31274/etd-180810-3179 · Cited by 6
Principles of Rehabilitation Following Sports Injuries: Sports‐Specific Performance Testing
McHugh, M. P., Bangsbo, J., & Lexell, J. E. (2003) · Wiley eBooks · doi:10.1002/9780470757277.ch10 · Cited by 6
Automated feature detection in multidimensional images : a unified tensor approach
Heiberg, E. (2001) · Cited by 2
Page, J. L. (2024) · ChesterRep (University of Chester) · doi:10.17638/03181639 · Cited by 2
Kinetic indices and dialysis outcomes
Prado-Velasco, M., Roa, L. M., Palma, A., & Milán, J. A. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1280485 · Cited by 2
Multiwavelength Shack-Hartmann Aberrometer
Jain, P. (2006) · UA Campus Repository (The University of Arizona) · Cited by 2
Eye-hand coordination : an exploration of measurement and different training methods using the SVT
Ellison, P. (2015) · Edge Hill University · Cited by 7
Heintze, S. D. (2010) · University of Groningen research database (University of Groningen / Centre for Information Technology) · Cited by 2
The competence of physiotherapists to deliver a cognitive behavioural approach for low back pain
Hansen, Z. (2026) · Warwick Research Archive Portal (University of Warwick) · doi:10.82444/warw.33646315 · Cited by 2
Outcome Measures in Clinical Trials
Heyse, J. F. (2014) · Wiley eBooks · doi:10.1002/9781118445112.stat04953 · Cited by 2
Physical activity engagement in people with Multiple Sclerosis
Kayes, N. M. (2010) · Tuwhera (Auckland University of Technology) · Cited by 4
STUDIES ON ENERGY EXPENDITURE IN WALKING AFTER STROKE
Danielsson, A. (2008) · Gothenburg University Publications Electronic Archive (Gothenburg University) · Cited by 2
Aherne, A., Polet, P., Atkinson, E., STEPHENS, S. R., Day, J., & Rogers, P. J. (1998) · Proceedings of The Nutrition Society · doi:10.1079/pns19980094 · Cited by 2
Quantitative Molecular Techniques
Nolte, F. S. (2009) · Wiley eBooks · doi:10.1128/9781555815974.ch15 · Cited by 2
Measuring disease progression in MS: do patients' and physicians' perspectives match?
Kragt, J. J. (2010) · Digital Academic REpository of VU University Amsterdam (Vrije Universiteit Amsterdam) · Cited by 3
Real‐Time, Automated Echocardiographic Measures of Ventricular Area and Area Change:
Martin, G. R., Seibel, N. L., & Majd, M. (1994) · Echocardiography · doi:10.1111/j.1540-8175.1994.tb01055.x · Cited by 2
La condición física como determinante de salud en personas jóvenes
Ruiz, J. R. (2008) · Apunts Educación Física y Deportes · Cited by 13
[Diagnosis of complex congenital heart disease through magnetic resonance].
Gonzalez, A. M. M., González, M. H., Rosas, E. A., Antona, C. V., Orellana, J. E., Meza, S. S., Ibarra, J. L. R., & Hernández, A. B. (2005) · PubMed · Cited by 2
Biomechanics of Falls and Hip Fractures in Older Adults
Choi, W. J. (2013) · Summit (Simon Fraser University) · Cited by 2
Training intensity distribution, physiological adaptation and immune function in endurance athletes
Neal, C. M. (2011) · Stirling Online Research Repository (University of Stirling) · Cited by 2
The Relative Accuracy of Three Transcutaneous Dual Electrodes at 45 °C in Adults
Lanigan, C., Ponte, J., & Moxham, J. (1987) · Springer eBooks · doi:10.1007/978-1-4613-1927-6_57 · Cited by 2
Local and personalised modelling for renal medical Decision Support System
Tian, M. (2012) · Tuwhera (Auckland University of Technology) · Cited by 2
Modeling the development of in vitro and in vivo pressure-induced muscle damage
Ceelen, K. K. (2008) · TU/e Research Portal · doi:10.6100/ir633963 · Cited by 4
Estimación no-invasiva de la presión de pulso arterial a partir de imágenes ecográficas en modo B
Graf, S., & Armentano, R. L. (2007) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-74471-9_82 · Cited by 2
Borchardt, S. (2011) · Universitätsbibliothek der FU Berlin Hochschulschriftenstelle u. Dokumentenserver · doi:10.17169/refubium-15799 · Cited by 2
DEVELOPMENT, EVALUATION AND APPLICATION OF A PEDIATRIC ULCERATIVE COLITIS ACTIVITY INDEX (PUCAI)
Turner, D. (2008) · Europe PMC (PubMed Central) · Cited by 3
Evaluation of a Commercial Standard for Checking Pulse Oximeter Performance
Volsko, T. A., Chatburn, R. L., & Kallstrom, T. J. (1996) · Respiratory Care · doi:10.1177/002013249604100203 · Cited by 2
Elfving, B. (2002) · Figshare · Cited by 5
Long-term consequences of differences in early growth : epidemiological aspects
Euser, A. M. (2009) · Leiden Repository (Leiden University) · Cited by 2
Development of Radiance for Advanced Lighting Simulation of Novel Daylighting Technologies
Edmonds, I., & Greenup, P. (2001) · Cited by 2
Developing advanced mathematical models for detecting abnormalities in 2D/3D medical structures.
Elnakib, A. A. (2013) · ThinkIR: The University of Louisville's Institutional Repository (University of Louisville) · doi:10.18297/etd/402 · Cited by 6
Physiotherapy for osteoarthritis of the knee: predictors of outcome at one year
Chapple, C. (2012) · Otago University Research Archive (University of Otago) · Cited by 5
Grömping, U. (2013) · Journal of Statistical Software · doi:10.18637/jss.v052.b03 · Cited by 2
Transcutaneous and End-Tidal Capnometry
Lain, D. C. (2007) · Respiratory Care · doi:10.4187/respcare.07520340a · Cited by 2
HUMMING, NITRIC OXIDE AND PARANASAL SINUS VENTILATION
Maniscalco, M. (2006) · Figshare · Cited by 2
Saulnier, F., Durocher, A., Cadélis, G., Drault, J. N., & Wattel, F. (1993) · Réanimation Urgences · doi:10.1016/s1164-6756(05)80201-4 · Cited by 2
Lazzer, S., Boirie, Y., Itier, A., Brandolini, M., Meyer, M., & Vermorel, M. (2005) · Cahiers de Nutrition et de Diététique · doi:10.1016/s0007-9960(05)80466-3 · Cited by 2
Wetsch, W. A., Carlitscheck, M., Spelten, O., & Hinkelbein, J. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.09.234 · Cited by 2
Dixon, R., Meire, H. B., Leigh, C., Posner, J., & Rolan, P. E. (1996) · Cephalalgia · doi:10.1046/j.1468-2982.1996.1607507.x · Cited by 2
Evaluation of simple methods to estimate total body fat in healthy women
Sohlström, A., Forslund, A. H., Sjödln, A., & Forsum, E. (1992) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/j.1600-0838.1992.tb00344.x · Cited by 3
Urea Kinetic Modeling: Comparing the Options
Hoenich, N. A., Keir, M. J., Hildreth, K., Woffindin, C., Goodall, R., Vanholder, R. C., & Ward, M. K. (1993) · Artificial Organs · doi:10.1111/j.1525-1594.1993.tb00636.x · Cited by 2
Yan, Y. L., Tan, Y. Y., Chang, T. C., & Yeo, G. S. H. (1995) · Australian and New Zealand Journal of Obstetrics and Gynaecology · doi:10.1111/j.1479-828x.1995.tb01975.x · Cited by 2
Measurement of cardiac output in pregnancy by thermodilution and impedance techniques
Sramek, B. B. (1990) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1990.tb01728.x · Cited by 2
Leibowitz, A. B. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31819304e5 · Cited by 2
Assessment of test repeatability of arterial stiffness index
Sharma, G. K., Gudapati, S. B., Waller, J. L., & Prisant, L. M. (2005) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000180670.76279.8e · Cited by 2
Cysteinyl‐leukotrienes in nasal lavage fluid in children with asthma
Singer, F., Horak, F., Friesenbichler, W., Schneider, B. K., Szépfalusi, Z., & Frischer, T. (2008) · Pediatric Allergy and Immunology · doi:10.1111/j.1399-3038.2007.00614.x · Cited by 2
Validation of Foot to Foot Bioelectrical Impedance in 6- to 10-Year-Old Children
Abbott, R. A., & Davies, P. S. W. (2000) · KARGER eBooks · doi:10.1159/000061771 · Cited by 2
Takase, B., Hosaka, H., Kitamura, K., Uehata, A., Satomura, K., Isojima, K., Kosuda, S., Kusano, S., Kurita, A., & Ohsuzu, F. (2001) · Japanese Heart Journal · doi:10.1536/jhj.42.749 · Cited by 2
Ellis, K. J. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.8.1469 · Cited by 2
Hein, H., Abdallah, C., Jugert, C., Kuziek, G., & MAGNUSSEN, H. (1998) · Somnologie - Schlafforschung und Schlafmedizin · doi:10.1007/s11818-998-0025-9 · Cited by 2
A reverse engineering schema to monitor 3-D control of upper limbs while playing the Wii
Schmid, M., Bibbo, D., Conforto, S., & D’Alessio, T. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.07.070 · Cited by 2
Evaluation of isotope proctography in constipated subjects
Halligan, S. (1993) · International Journal of Colorectal Disease · doi:10.1007/bf00290312 · Cited by 2
An esothoracic electrode for electrophysiological studies
MCENEANEY, D. J. (2002) · Journal of Electrocardiology · doi:10.1054/jelc.2002.371731 · Cited by 2
Shieh, H. H., Ventura, A. M. C., & Bousso, A. (2010) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0b013e3181dab1c5 · Cited by 2
Arterialised blood gas sampling in the critically ill: Correct tools for the job?
Singh, S. (2008) · Indian Journal of Critical Care Medicine · doi:10.4103/0972-5229.43675 · Cited by 2
Perret, C., Poiraudeau, S., Fermanian, J., & Revel, M. (2000) · Annales de Réadaptation et de Médecine Physique · doi:10.1016/s0168-6054(00)88986-2 · Cited by 2
Reliability of Screening for Sensory Impairment in Depressed Versus Nondepressed Older Adults
Andelin, L. C., Alessi, C., & Aronow, H. U. (1995) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1995.tb07207.x · Cited by 2
Wootton, R., Flecknell, P. A., & Mehta, A. (1987) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/8/4/008 · Cited by 2
Morales, M., Positano, V., Lombardi, M., Rodriguez, O., Passera, M., & Rovai, D. (2004) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.04.026 · Cited by 2
Thermodilution cardiac output measurements during conventional and high-frequency ventilation
SHERRY, K. M., Feneck, R. O., & Normandale, J. P. (1988) · Journal of Cardiothoracic Anesthesia · doi:10.1016/0888-6296(88)90312-2 · Cited by 2
Sjöberg, F., Vegfors, M., & Lennmarken, C. (1990) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519009087517 · Cited by 2
Cox regression was used to compare the measurement error of two tests vs. a gold standard
Virgili, G., Angi, M. R., Molinari, A., & Casotto, V. (2007) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2006.07.013 · Cited by 2
Campillo, B., Bories, P. N., & Pornin, B. (1997) · Nutrition Clinique et Métabolisme · doi:10.1016/s0985-0562(97)80054-4 · Cited by 2
Thein, E., Raab, S., Harris, A. G., Kleen, M. S., Habler, O. P., Pape, A., Meisner, F. G., & Messmer, K. (2009) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1998.43.s1.536 · Cited by 2
Terrier, F., Toumiaire, J., Belenger, J., Slosman, D. O., Rubbia, L., Grossholz, M., Mentha, G., Hiltbrand, E., & Mermillod, B. (1995) · Academic Radiology · doi:10.1016/s1076-6332(05)80116-3 · Cited by 2
Is pericardium a suitable calibration reference in integrated backscatter analysis?
Voon, W., Chiu, C., Su, H., Chen, H., Hsieh, C., Huang, J., Lai, W., Sheu, S., & Lin, Y.-T. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.06.001 · Cited by 2
Étude comparative du dosage sérique de la 25-OH vitamine D3 sur Elecsys® versus Liaison®
Szymanowicz, A., Devaux, C., & Neyron, M.-J. (2009) · Immuno-analyse & Biologie Spécialisée · doi:10.1016/j.immbio.2009.03.003 · Cited by 3
Measurement of HbA1 using patient‐collected finger‐prick specimens
Patel, V., McNally, P. G., Chambers, K., Swift, P., & Mitchell, V. (1993) · Practical Diabetes · doi:10.1002/pdi.1960100508 · Cited by 2
Inhaled nedocromil sodium in symptomatic young children born prematurely
Yuksel, B., & Greenough, A. (1996) · Respiratory Medicine · doi:10.1016/s0954-6111(96)90173-0 · Cited by 2
Accurate biometry in silicone oil-filled eyes
Symes, R. J. (2013) · Eye · doi:10.1038/eye.2013.59 · Cited by 2
Determining cell density in breast carcinomas
Haerslev, T., & Skovgaard, L. T. (1994) · Human Pathology · doi:10.1016/0046-8177(94)90158-9 · Cited by 2
Optimization of cyclosporine therapy in kidney transplantation
Remuzzi, G., Perico, N., & Gaspari, F. (1998) · Transplantation Proceedings · doi:10.1016/s0041-1345(98)00387-x · Cited by 2
Hiremath, S. S., Edwards, C., McCormick, B. B., & Ruzicka, M. (2014) · Journal of Clinical Hypertension · doi:10.1111/jch.12332 · Cited by 2
Mega, M. S., Dinov, I. I., Mazziotta, J. C., Manese, M., Thompson, P. M., Lindshield, C., Moussai, J., Tran, N., Olsen, K., Felix, J., et al. (2004) · Neurobiology of Aging · doi:10.1016/s0197-4580(04)80908-4 · Cited by 2
Vaitkus, P. T., Higgins, J. C., Watkins, M. W., Brown, K. A., & Battle, R. W. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80209-4 · Cited by 2
Question 3-6. Les questionnaires d’activité physique - application aux BPCO
Varray, A. L. (2005) · Revue des Maladies Respiratoires · doi:10.1016/s0761-8425(05)85703-1 · Cited by 2
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.