STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 40,701–40,800 of 47,868
Automating the timed up and go test (tug test) with wearable sensors
Beyea, J. (2017) · Cited by 3
Borges, J. H., Langer, R. D., Cirolini, V. X., Páscoa, M. A., Guerra‐Júnior, G., & Gonçalves, E. M. (2017) · Nutrition · doi:10.1016/j.nut.2017.03.001 · Cited by 2
Establishing Agreement between Parent-reported and Directly-measured Behaviours
Bennetts, S. K., Mensah, F. K., Westrupp, E. M., Hackworth, N. J., Nicholson, J. M., & Reilly, S. (2017) · Australasian Journal of Early Childhood · doi:10.23965/ajec.42.1.12 · Cited by 2
Chang, D. C., Piaggi, P., & Krakoff, J. A. (2017) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2017.04.009 · Cited by 2
Slattery, F., Schermer, T. R., Esterman, A., Johnston, K., & Crockett, A. J. (2017) · Canadian Respiratory Journal · doi:10.1155/2017/6327180 · Cited by 2
Comparing two measurement systems using the probability of agreement web app
da Rocha, L. T., & Stevens, N. T. (2017) · Quality Engineering · doi:10.1080/08982112.2017.1361538 · Cited by 2
Comparison of registry and government evaluation data to ascertain severe trauma cases in Japan
Nakahara, S., Sakamoto, T., Fujita, T., Koyama, T., Katayama, Y., Tanabe, S., & Yamamoto, Y. (2017) · Acute Medicine & Surgery · doi:10.1002/ams2.302 · Cited by 3
Facial shape; height and width in the second and third trimester of pregnancy
den Boogert, A., de Jong-Pleij, E., Ribbert, L. S. M., Pistorius, L. R., Tromp, E., & Bilardo, C. M. (2017) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2017.1384807 · Cited by 2
The letter knowledge assessment tool
Pedro, C., Lousada, M., Pereira, R., Hall, A. O., & Jesus, L. M. T. (2017) · Logopedics Phoniatrics Vocology · doi:10.1080/14015439.2017.1384055 · Cited by 2
Oyapero, O., Njokanma, O. F., & Disu, E. A. (2017) · Journal of Clinical Neonatology · doi:10.4103/jcn.jcn_24_17 · Cited by 2
Ohya, N., Yamada, T., & Sato, Y. (2017) · Rigakuryoho Kagaku · doi:10.1589/rika.32.603 · Cited by 2
Brodin, N., Grooten, W. J. A., Stråt, S., Löfberg, E., & Alexanderson, H. (2017) · BMC Research Notes · doi:10.1186/s13104-017-2991-0 · Cited by 2
Resolving the test–retest agreement or reliability dilemma
Thomas, H. (2017) · Methodological Innovations · doi:10.1177/2059799117703121 · Cited by 2
Yellow–green laser‐based flow cytometry for CD34+ progenitor cell counting
Rico, L. G., Juncà, J., Ward, M. D., Bradford, J. A., & Pétriz, J. (2017) · Cytometry Part A · doi:10.1002/cyto.a.23299 · Cited by 4
Kalman Filter Models for the Prediction of Individualised Thermal Work Strain
Guo, J., Chen, Y., Fan, W. P., Lee, S. H. M., Ong, J., Tan, P. L., Law, L. Y. L., LEE, J. K. W., & Seng, K. (2018) · InTech eBooks · doi:10.5772/intechopen.71205 · Cited by 2
Lund‐Andersen, C., Petersen, H. H., Jøns, C., Philbert, B. T., Tfelt‐Hansen, J., Skovgaard, L. T., & Svendsen, J. H. (2018) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-018-0334-2 · Cited by 2
Comparison of predictive equations of lean mass in young and postmenopausal women
de Branco, F. M. S., de Paula, A. L. B., Rossato, L. T., Barreiro, S. M., Nahas, P. C., Murta, E. F. C., Orsatti, F. L., & de Oliveira, E. P. (2018) · Clinical Nutrition ESPEN · doi:10.1016/j.clnesp.2018.01.068 · Cited by 2
Pulse wave analysis reproducibility with the Complior Analyse device: a methodological study
Pereira, T. S., & Maldonado, J. M. P. (2018) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000316 · Cited by 3
Kolesnyk, M. Y., & Sokolova, M. V. (2018) · Zaporozhye Medical Journal · doi:10.14739/2310-1210.2018.1.121875 · Cited by 2
Pestel, G., Fukui, K., Higashi, M., Schmidtmann, I. M., & Werner, C. D. (2018) · Der Anaesthesist · doi:10.1007/s00101-018-0452-3 · Cited by 2
Pereira, T. S., & Guimarães, J. (2018) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000330 · Cited by 3
Ha, S., & Lee, J. J. (2018) · Nuclear Medicine and Molecular Imaging · doi:10.1007/s13139-018-0529-6 · Cited by 2
Ishihara, M., Onoguchi, M., & Shibutani, T. (2018) · Molecular Imaging · doi:10.1177/1536012118782322 · Cited by 2
QCM-D sensor for the dose management of Apixaban in replacement surgery
Hussain, M., Schmidt, K., Körber, M. K., Langer, E., Faul, O., Northoff, H., Wendel, H. P., von Heymann, C., & Gehring, F. K. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.08.049 · Cited by 2
Baghel, P., Walia, S., & Noohu, M. M. (2018) · Hong Kong Physiotherapy Journal · doi:10.1142/s1013702518500099 · Cited by 2
Blasimann, A., Eichelberger, P., Lutz, N., Radlinger, L., & Baur, H. (2018) · The Foot · doi:10.1016/j.foot.2018.08.002 · Cited by 2
Pfeifer, C. M., Rowen, D. A., Buster, T. W., Cesar, G. M., Irons, S. L., & Burnfield, J. M. (2018) · Journal of Medical Devices · doi:10.1115/1.4041337 · Cited by 2
Statistical Assessment of Agreement
Mukherjee, S. P., SINHA, B. K., & Chattopadhyay, A. K. (2018) · Springer eBooks · doi:10.1007/978-981-13-2146-7_6 · Cited by 3
Radiological Evaluation of TATE Elbow Cartridge Position in Dogs
Shaw, T. R., Knowles, T. G., Burton, N. J., & Nutt, A. E. (2018) · Veterinary and Comparative Orthopaedics and Traumatology · doi:10.1055/s-0038-1673339 · Cited by 2
Dahaba, A. A., Suljević, I., Xiao, Z. Y., & Wang, K. (2018) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-018-0231-3 · Cited by 2
Oyapero, O., Njokanma, F., & Disu, E. A. (2018) · Archives of Medicine and Health Sciences · doi:10.4103/amhs.amhs_123_17 · Cited by 2
Gerber, D., Vasireddy, R., Varadarajan, B., Hartwich, V., Schär, M. Y., Eberle, B., & Vogt, A. P. (2019) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-018-00245-0 · Cited by 2
Inter-Annotator Agreement in linguistica: una rassegna critica
Gagliardi, G. (2018) · Accademia University Press eBooks · doi:10.4000/books.aaccademia.3375 · Cited by 7
Development of a Multi-Purpose Easy-to-Use Set of Tools for Home Based Rehabilitation
David, V., Forjan, M., Paštěka, R., Scherer, M., & Hofstätter, O. (2018) · International Conference on Software Development and Technologies for Enhancing Accessibility and Fighting Info-exclusion (DSAI) · doi:10.1145/3218585.3218677 · Cited by 2
Möller, D., Ballenberger, N., & Zalpour, C. (2019) · Jahrbuch der Deutschen Gesellschaft für Musikpsychologie/Jahrbuch Musikpsychologie · doi:10.5964/jbdgm.2018v28.35 · Cited by 2
Utility of point‐of‐care vs reference laboratory testing for the evaluation of glucose levels
Andriankaja, O. M., Muñoz‐Torres, F. J., Vergara, J. L., Pérez, C. M., & JOSHIPURA, K. J. (2019) · Diabetic Medicine · doi:10.1111/dme.13922 · Cited by 2
Queirós, S., Morais, P., Fonseca, J. C., D’hooge, J., & Vilaça, J. L. (2019) · SPIE Medical Imaging: Image Processing · doi:10.1117/12.2512777 · Cited by 2
Valle, F. M., Mario Vargas, L., Cueva‐Quiroz, V. A., Alberto Manchego, S., & Nieves Sandoval, C. (2019) · Revista de Investigaciones Veterinarias del Perú · doi:10.15381/rivep.v30i1.15695 · Cited by 2
McGeown, J. P., Hume, P. A., Theadom, A., Kara, S., & Russell, B. K. (2022) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2021.11.017 · Cited by 2
STANDARDIZATION OF SPIROMETRY: HOW TO IMPROVE THE RESULT
Chushkin, M., La, P., On, O., & Стручков, П. В. (2019) · Tuberculosis and lung diseases · doi:10.21292/2075-1230-2019-97-2-26-32 · Cited by 2
Hu, L., Huang, Q., Cui, T., Duarte, I., Miller, G. W., Mugler, J. P., Cates, G. D., Mata, J. F., de Lange, E. E., Altes, T. A., et al. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab160c · Cited by 2
Oshita, T., Yabuuchi, H., & Masanobu, O. (2019) · The Neuroradiology Journal · doi:10.1177/1971400919834693 · Cited by 2
Validity of block start performance without arm forces or by kinematics-only methods
Otsuka, M., Potthast, W., Willwacher, S., Goldmann, J., Kurihara, T., & Isaka, T. (2019) · Sports Biomechanics · doi:10.1080/14763141.2019.1593497 · Cited by 2
Serial blood volume estimation in rabbits using trivalent chromium – An exploratory study
Baby, P. M., Kumar, P., Kumar, R., Jacob, S., Rawat, D., Binu, V. S. N., Karun, K. M., & Bhat, N. B. (2019) · MethodsX · doi:10.1016/j.mex.2019.05.009 · Cited by 2
Does low back pain affect the reliability of postural regulation?
Lauenroth, A., Reinhardt, L., Schulze, S. D., Laudner, K. G., Delank, K.-S., & Schwesig, R. (2019) · Somatosensory & Motor Research · doi:10.1080/08990220.2019.1615427 · Cited by 3
Jalili, M., Nazem, F., & Sazvar, A. (2018) · Journal of Shahrekord University of Medical Sciences · doi:10.34172/jsums.2019.04 · Cited by 2
Nikooyeh, B., & Neyestani, T. R. (2019) · Nutrition and Food Sciences Research · doi:10.29252/nfsr.6.2.1 · Cited by 3
Nakashima, T., Ohno, T., Koido, K., Hashimoto, H., & Terakado, H. (2019) · Journal of Oncology Pharmacy Practice · doi:10.1177/1078155219851834 · Cited by 2
Quantification of the Finger Tapping Test Based on the Flex Sensor—A Single Case Study
Jablonski, G., Luiz, L. M. D., Rabelo, A. G., & Andrade, A. D. O. (2019) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-13-2119-1_83 · Cited by 2
Salas, J. D. Z., & Murray, A. L. (2018) · Archivos Latinoamericanos de Nutrición · doi:10.37527/2018.68.1.007 · Cited by 2
Hatkar, S., Kadam, S. S., Khatkhatay, M. I., & Desai, M. P. (2019) · Indian Journal of Clinical Biochemistry · doi:10.1007/s12291-019-00841-0 · Cited by 2
Oxygen Uptake of Wave Surfers and Complementary Parameters in Front Crawl and Surfing-Paddling Tests
Godoy, D. F., Cadore, E. L., Feitosa, W. G., Correia, R. D. A., & Castro, F. A. D. S. (2019) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003205 · Cited by 2
Krausz, A. D., Dewar, R., & Burns, M. A. (2019) · The Journal of Applied Laboratory Medicine · doi:10.1373/jalm.2019.030031 · Cited by 3
Changes in intraocular pressure after intraocular eye surgery—the influence of measuring technique
Kovacic, H., Wolfs, R. C. W., Kılıç, E., & Ramdas, W. D. (2019) · International Journal of Ophthalmology · doi:10.18240/ijo.2019.06.14 · Cited by 2
Mello, M. M., Watte, G., Altmayer, S., Pallaoro, Y. L. D. R., Spilimbergo, F. B., Blanco, D. C., Meyer, G. M. B., Marchiori, E. D. S., & Hochhegger, B. (2019) · Radiologia Brasileira · doi:10.1590/0100-3984.2018.0128 · Cited by 2
Aherne, E. A., Koktzoglou, I., Lind, B. B., & Edelman, R. R. (2019) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-019-0562-3 · Cited by 2
A new maximal bicycle test using a prediction algorithm developed from four large COPD studies
Eriksson, G., Radner, F., Peterson, S., Papapostolou, G., Jarenbäck, L., Jönsson, S., Ankerst, J., Tunsäter, A., Tufvesson, E., & Bjermer, L. H. (2019) · European Clinical Respiratory Journal · doi:10.1080/20018525.2019.1692645 · Cited by 2
Ismail, I., Narayanan, L. T., Hasan, R. A., & Supriyanto, E. (2019) · Sains Malaysiana · doi:10.17576/jsm-2019-4810-16 · Cited by 2
Liu, S., Rétory, Y., Sagniez, A., Hardy, S., Cottin, F., Roisman, G. L., & Petitjean, M. (2019) · PLoS ONE · doi:10.1371/journal.pone.0225766 · Cited by 2
John, J., Krishna, S., & Galigekere, R. R. (2020) · IEEE Access · doi:10.1109/access.2020.2973815 · Cited by 2
New Measures of Journal Impact Based on the Number of Citations and PageRank
Souma, W., Vodenska, I., & Chitkushev, L. T. (2019) · Journal of Digital Information Management · doi:10.6025/jdim/2020/18/1/11-20 · Cited by 4
Macharzina, R. R., Kocher, S., Hoffmann, F., Becher, H. H., Kammerer, T., Vogt, M., Vach, W., Fan, N., Rastan, A., Neumann, F., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.12.022 · Cited by 2
Use of portable gas analyzers during pediatric field testing
Itaborahy, B. D. H., Wamosy, R. M. G., Scalco, J. C., & Schivinski, C. I. S. (2020) · Pediatric Pulmonology · doi:10.1002/ppul.24700 · Cited by 2
Caruso, F., Trimer, R., Goulart, C. D. L., Ricci, P. A., Garcia-Araújo, A. S., Carmargo, P., Marinho, R. S., dos Santos, P. B., da Silva, A. L. G., Mendes, R. G., et al. (2020) · Physiotherapy Research International · doi:10.1002/pri.1837 · Cited by 3
Impact of tumour size measurement inter-operator variability on model-based drug effect evaluation
Lombard, A., Mistry, H. B., Chapman, S. C., Gueoguieva, I., Aarons, L. J., & Ogungbenro, K. (2020) · Cancer Chemotherapy and Pharmacology · doi:10.1007/s00280-020-04049-5 · Cited by 2
Determination of minimal recording period to assess resting heart rate variability during pregnancy
da Silva, D. F., Mohammad, S., Hutchinson, K. A., & Adamo, K. B. (2020) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2019-0351 · Cited by 2
Xu, J., Sonntag, R., Kretzer, J. P., Taylor, D., Forst, R., & Seehaus, F. (2020) · Materials · doi:10.3390/ma13071543 · Cited by 2
Assessment of Cardiac Output in Neonates
de Boode, W. P., Osypka, M. J., Soleymani, S., & Noori, S. (2019) · Elsevier eBooks · doi:10.1016/b978-0-323-53366-9.00014-4 · Cited by 2
Moffet, C. A., & Gunter, S. A. (2020) · Livestock Science · doi:10.1016/j.livsci.2020.104153 · Cited by 2
Młyńczak, M., Valdez, T. A., & Kukwa, W. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102614 · Cited by 2
Straßer, T., Kurtenbach, A., Langrová, H., Kuehlewein, L., & Zrenner, E. (2020) · Scientific Reports · doi:10.1038/s41598-020-69952-6 · Cited by 2
Anaerobic Threshold in Stand-up Paddle: Comparison Between Direct and Alternative Methods
Balikian, P., Marinho, A. H., de Araújo, G. G., Prado, E. S., Mendes, E. V., & Geraldes, A. (2020) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003718 · Cited by 5
How Accurate is the Use of Contralateral Implant Size as a Template in Bilateral Hemiarthroplasty?
Marappa-Ganeshan, R., Sim, F. C. J., Sidhom, S., Chakrabarty, G., Pandit, H. G., & van Duren, B. H. (2020) · Indian Journal of Orthopaedics · doi:10.1007/s43465-020-00203-6 · Cited by 2
Zheng, Y., Li, W., Sui, F., Ma, H., Wang, H., & Wang, Z.-J. (2020) · Journal of Surgical Research · doi:10.1016/j.jss.2020.08.022 · Cited by 2
Thewlis, D., Waters, A., Solomon, L. B., & Perilli, E. (2020) · Bone · doi:10.1016/j.bone.2020.115662 · Cited by 2
Paramanandam, V. S., Daptardar, A. A., Kamat, M. V., Lee, M., Ward, L. C., Kilbreath, S. L., & Dylke, E. S. (2020) · Lymphatic Research and Biology · doi:10.1089/lrb.2020.0072 · Cited by 2
Choksi Khushali, K., Rathi Ambika, L., Trushna, G., & Patel Shivani, M. (2020) · International Journal of Scientific and Research Publications · doi:10.29322/ijsrp.10.09.2020.p10588 · Cited by 2
Mills, C. D. (2020) · Open Access Journal of Biomedical Science · doi:10.38125/oajbs.000227 · Cited by 2
Estimation of Voice Perturbation Measures Using Signal Processing Algorithms
Karunaimathi, V. P., Gladis, D., & Balakrishnan, D. (2020) · International Journal of Engineering Research and Technology · doi:10.37624/ijert/13.11.2020.3806-3813 · Cited by 2
MRI-Derived Tumour-to-Breast Volume Is Associated with the Extent of Breast Surgery
Cozzi, A., Schiaffino, S., Pepa, G. D., Carriero, S., Magni, V., Spinelli, D., Carbonaro, L. A., & Sardanelli, F. (2021) · Diagnostics · doi:10.3390/diagnostics11020204 · Cited by 2
Preciado, L. L. S., Vallarta‐Robledo, J. R., Chávez‐Palencia, C., Lizárraga‐Corona, E., & Larrosa‐Haro, A. (2021) · American Journal of Human Biology · doi:10.1002/ajhb.23585 · Cited by 4
Baert, J., Pomar, L., Mchirgui, A., Lambert, V., Carles, G., Hcini, N., Baud, D., & Vial, Y. (2021) · Journal of Pediatric Neurology · doi:10.1055/s-0041-1722854 · Cited by 2
de Rê, A., Fonseca, F. R., Queiroz, A. P., dos Reis, C. M., Bahl, M., Kocks, J. W. H., van der Molen, T., & Maurici, R. (2021) · Jornal Brasileiro de Pneumologia · doi:10.36416/1806-3756/e20200371 · Cited by 2
Allometric scaling and growth: Evaluation and applications in subadult body mass estimation
Yim, A., Konigsberg, L. W., Hwa, H., Chang, C., Chen, J., & Liu, H. (2021) · American Journal of Physical Anthropology · doi:10.1002/ajpa.24329 · Cited by 3
Real-time multimodal 3D imaging system for remote estimation of vital signs
Zhang, C., Gebhart, I., Kühmstedt, P., Rosenberger, M., & Notni, G. (2021) · doi:10.1117/12.2592660 · Cited by 2
Majors, C. E., Pawłowski, M. E., Tkaczyk, T., Dube, Q., & Richards-Kortum, R. R. (2021) · Annals of Biomedical Engineering · doi:10.1007/s10439-021-02827-7 · Cited by 2
The new Roche Elecsys TSH assay conforms with current IFCC C-STFT standards
Kratzsch, J., Baumann, N. A., Ceriotti, F., Lu, Z. X., Schott, M., van Herwaarden, A. E., Vieira, J. G. H., Lehmann, H., Kasapic, D., & Giovanella, L. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0352 · Cited by 3
Three-Way Mixed Effect ANOVA to Estimate MRMC Limits of Agreement
Wen, S., & Gallas, B. D. (2022) · Statistics in Biopharmaceutical Research · doi:10.1080/19466315.2022.2063169 · Cited by 3
Instrumented Footwear and Machine Learning for Gait Analysis and Training
de la Mora, P. (2021) · Columbia Academic Commons (Columbia University) · doi:10.7916/d8-9amh-da27 · Cited by 2
Lischke, R., Shajari, M., Feucht, N., Kook, D., Bechmann, M., Wiltfang, R., Priglinger, S. G., & Mayer, W. J. (2021) · Current Eye Research · doi:10.1080/02713683.2021.1962362 · Cited by 2
Modulus of Elasticity of Elastic Tubes Used in Neuromuscular Rehabilitation Programs
Reis, A. L., Reis, T. L., de Aguiar, L. S., Reis, J. D. J. S., Reis, T. L., Deus, L. A., Neves, R. V. P., Corrêa, H. D. L., Honorato, F. S., de Araújo, T. B., et al. (2021) · Journal of Sport Rehabilitation · doi:10.1123/jsr.2021-0085 · Cited by 2
Farklı Tükenme Aralıkları ve Matematiksel Model Kullanımının Kritik Güç Tahminlerine Etkisi
NOROUZI, M., Çabuk, R., Balcı, G. A., As, H., & Özkaya, Ö. (2021) · Spor Bilimleri Dergisi · doi:10.17644/sbd.931304 · Cited by 3
Gabrysz‐Forget, F., Maynard-Paquette, A.-C., Kharat, A., Tremblay, F., Carricart, M., Lavoie, A., Girard, M., & Dubé, B. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808770 · Cited by 3
The Application of Magnetic Resonance Imaging in Skeletal Age Assessment
Alshamrani, K. A. (2022) · Applied Bionics and Biomechanics · doi:10.1155/2022/9607237 · Cited by 2
RetractedThe impact of altering participant MRI scanning position on back muscle volume measurements
Alharthi, S. S., Meakin, J., Wright, C., & Fulford, J. (2022) · BJR|Open · doi:10.1259/bjro.20210051 · Cited by 2
Ishida, H., Yamamoto, Y., Saito, M., Ishihara, Y., Fujita, T., Ishida, M., Kato, Y., Nohisa, Y., Matsunami, H., Takemura, M., et al. (2022) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632221098870 · Cited by 2
Phungwattanakul, N., Boonyapo, U., & Wiangkham, T. (2022) · Physiotherapy Theory and Practice · doi:10.1080/09593985.2022.2063773 · Cited by 2
Cheng, S., Yan, W.-T., Zhang, J., Li, T., Li, X., & Yu, A. (2022) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-022-05681-y · Cited by 2
Structural Correlates of Neurological Signs in Huntington’s Disease: A Quantitative Approach
Loh, E. A., Roberts, J. K. A., & Mohr, E. (1994) · Behavioural Neurology · doi:10.1155/1994/208028 · Cited by 2
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.