STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 40,901–41,000 of 47,868
Kelly, A., & Middleton, P. M. (2003) · Emergency Medicine Australasia · doi:10.1046/j.1442-2026.2003.00455_1.x · Cited by 2
Luo, H., Fishbein, M. C., Berglund, H., Nishioka, T., Kim, C.-J., & Siegel, R. J. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00198-7 · Cited by 2
Point-of-care testing in anticoagulation reversal
Beynon, C., Potzy, A., & Sakowitz, O. W. (2015) · Thrombosis Research · doi:10.1016/j.thromres.2015.03.016 · Cited by 2
Rouse, S. J. (1998) · British Journal of Occupational Therapy · doi:10.1177/030802269806100209 · Cited by 2
Transesophageal Echocardiography Cardiac Output in FlowTrak/ Vigileo Study
Perez, W. J., & Perrino, A. C. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181d3264c · Cited by 2
Smith, J., & Truscott, J. (2006) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.2006.01269.x · Cited by 2
Multicenter Study on the Analytical Performance of a New Point-of-Care Blood Gas Analyzer
Boldt, J., Goerlach-Graw, A., Halwachs‐Baumann, G., Hindinger, J., Leinberger, R., Luebke, B., Nagel, D. W., Normand, H., Quintel, M., Riegebauer, J., et al. (2003) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/00134384-200309000-00012 · Cited by 2
Biometric gonioscopy for measuring the anterior chamber angle
Thomas, R. (2001) · Ophthalmology · doi:10.1016/s0161-6420(00)00399-7 · Cited by 2
de Greeff, A., & Shennan, A. H. (2007) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32809efa64 · Cited by 2
Feasibility of endocardial edge detection by using an inversion recovery artifact
Laffon, É., Cassen, C., Latrabe, V., Montaudon, M., Laurent, F., Massot, P., Ducassou, D., & Barat, J. L. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1067 · Cited by 2
Measurement decisions in nursing and midwifery research
Norman, I. J., & Griffiths, P. (2013) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2013.03.011 · Cited by 2
A method for estimating respiratory muscle efficiency using an automated metabolic cart
Sherman, M. S., Matityahu, A., & Campbell, D. (1996) · Respiration Physiology · doi:10.1016/s0034-5687(96)00071-0 · Cited by 2
Lee, C., Zhang, J., Kailasam, A., TAI, B., Ye, F., Low, A. F.-H., Hou, X., Hay, E. T., Teo, S.-G., Lim, Y., et al. (2008) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.2008.00397.x · Cited by 2
A High Significance Level after Analysis of Covariance in a Small-group Study?
Chen, T.-H. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318212b928 · Cited by 2
Drummond, G. B. (1994) · Anaesthesia · doi:10.1111/j.1365-2044.1994.tb03555.x · Cited by 2
Caswell, M., & Stuart, J. (1991) · Journal of Clinical Pathology · doi:10.1136/jcp.44.5.429 · Cited by 2
Dental health and acute myocardial infarction: Author's reply
Mattila, K. J. (1989) · BMJ · doi:10.1136/bmj.298.6687.1580 · Cited by 2
Ciarmiello, A., Pace, L., Betocchi, S., Alfano, B., Chiariello, M., & Salvatore, M. (1994) · Nuclear Medicine and Biology · doi:10.1016/0969-8051(94)90168-6 · Cited by 2
Inappropriate analysis of reproducibility
Delgado, J., & Maria, C. F. (2003) · British Journal of Haematology · doi:10.1046/j.1365-2141.2003.04661.x · Cited by 2
Nichtinvasives erweitertes hämodynamisches Monitoring
Bock, M., Sturm, T., & Motsch, J. (2007) · Der Anaesthesist · doi:10.1007/s00101-007-1189-6 · Cited by 2
Peripheral Light‐Focusing: Measurement Reliability and Correlations with Ocular Dimensions
Twelker, J. D., HARBISON, S. C., & Bailey, I. L. (2005) · Optometry and Vision Science · doi:10.1097/01.opx.0000153169.75212.1b · Cited by 2
Frequency of adverse drug reactions [letter; comment]
DeBoer, A. (1993) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1993.tb05901.x · Cited by 2
Lin, E., Hwang, J., & Yuan, C. (1999) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.1999.757574 · Cited by 2
Malagon, I. L. (1996) · Clinical Intensive Care · doi:10.1080/714028970 · Cited by 2
Husmann, L., Leschka, S., Desbiolles, L. M., Schepis, T., Koepfli, P., Gaemperli, O., Seifert, B., Flohr, T. G., Frauenfelder, T., Marinček, B., et al. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000236906.05265.4f · Cited by 2
A Triple Isotope Technique for Estimation of Fat and Vitamin B12Malabsorption in Crohn's Disease
Pedersen, N. T., & Rannem, T. (1991) · Scandinavian Journal of Gastroenterology · doi:10.3109/00365529109025047 · Cited by 2
Feasibility of sputum induction in lung transplant recipients
van den Berg, J. W., Slebos, D., Postma, D. S., Dijkhuizen, B., Koëter, G. H., Timens, W., van der Bij, W., & Kauffman, H. F. (2004) · Clinical Transplantation · doi:10.1111/j.1399-0012.2004.00237.x · Cited by 2
Left ventricular volume determination using colour superpositioning of contrast echocardiograms
Zotz, R. J., Genth, S., Rupprecht, H., Brennecke, R., Erbel, R. M., & Meyer, J. (1995) · European Journal of Ultrasound · doi:10.1016/0929-8266(94)00071-k · Cited by 2
An automated procedure for the determination of protein concentration in subcellular fractions
Voirol, P., Aubert, A.-C., Jonzier-Perey, M., & Baumann, P. (1998) · Clinica Chimica Acta · doi:10.1016/s0009-8981(98)00029-1 · Cited by 2
Incorrect analysis of data leads to incorrect conclusions
Hardy, J., Bélisle, S. J., & Gravel, N. R. (1997) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03013401 · Cited by 2
Knee moment at work: validation of a questionnaire based on knee moment in working life
Sahlström, A., Montgomery, F., & Balogh, I. (1996) · International Archives of Occupational and Environmental Health · doi:10.1007/bf00409417 · Cited by 2
Verdecchia, P., Angeli, F., Gattobigio, R., Angeli, E., Pede, S., & Pittavini, L. (2006) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000209072.92589.ea · Cited by 2
French, H. (2006) · Physical Therapy Reviews · doi:10.1179/108331906x163423 · Cited by 3
Doppler evaluation of aortic valve area in children with aortic stenosis
Weiss, P. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90036-m · Cited by 2
Interleukin 1α and hematological examination in mechanics exposed to low benzene concentrations
Hotz, P., Carbonnelle, P., Scheiff, J. M., Tschopp, A., & Lauwerys, R. (1998) · International Archives of Occupational and Environmental Health · doi:10.1007/s004200050245 · Cited by 2
Fetal transmission pulse oximetry: Is it accurate?
Nijland, R., van den Berg, P. P., & Jongsma, H. W. (2001) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2001.117477 · Cited by 2
Yang, Y., Pawlak, M. A., Macdonald, G. J., & Duggan, K. A. (1993) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.1993.tb01699.x · Cited by 2
Errors in 14 pulse oximeters during profound hypoxia
Gorback, M. S. (1990) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf02828294 · Cited by 2
Michelucci, A., Conti, A., Frati, M., Mininni, S., Padeletti, L., Porciani, M. C., Rostagno, C., Galanti, G., Cattot, G., Petrogalli, G., et al. (1998) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.1998.tb00027.x · Cited by 2
Outcome of breech delivery at term.
Cleary, R. (1992) · BMJ · doi:10.1136/bmj.305.6867.1499-c · Cited by 2
Yamauchi, T., Furui, S., Suzuki, S., Mimura, K., Hayashi, T., Yamada, T., Futami, C., Tsukiyama, Y., & Harada, M. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/5/014 · Cited by 2
Onimus, T., Saulnier, F., Beague, S., Pronnier, P., Nseir, S., & Durocher, A. (2002) · ITBM-RBM · doi:10.1016/s1297-9562(02)80030-4 · Cited by 2
Nathanson, I. T. (1995) · Pediatric Pulmonology · doi:10.1002/ppul.1950190112 · Cited by 2
Reproducibility of intravenous linear pharmacokinetic parameters of ethanol in dogs
Tzamaloukas, A. H., Jackson, J. E., Gallegos, J. C., McLane, M. M., & Long, D. A. (1987) · Alcohol · doi:10.1016/0741-8329(87)90002-4 · Cited by 2
Molina, C. G. E., Landeros, L. C., Lira, J. R. R. D., Castañeda, R. E., Cisneros, E. A., & Rodríguez, V. M. V. (2005) · MEDICRIT Revista de Medicina Crítica · doi:10.5413/mrmc.2005.28.50 · Cited by 2
Assessing observer variability: Authors' reply
Brennan, P., & Silman, A. J. (1992) · BMJ · doi:10.1136/bmj.305.6848.313-c · Cited by 2
Kirkegaard-Nielsen, H., Helbo-Hansen, H. S., Lindholm, P., Severinsen, I. K., & Bülow, K. (1995) · International journal of clinical monitoring and computing · doi:10.1007/bf01207198 · Cited by 2
On the Analysis and Interpretation of Spontaneous Variability of Cardiac Output
Nguyen, T. V., & Hillman, K. (2001) · Critical Care Medicine · doi:10.1097/00003246-200101000-00051 · Cited by 2
GAUDY, J. H., Sicard, J.-F., & Quignon, M. (1992) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03008289 · Cited by 2
Random Blood Glucose Estimation in Type 2 Diabetes: Does it Reflect Overall Clycaemic Control?
Gulliford, M. C. (1995) · Diabetic Medicine · doi:10.1111/j.1464-5491.1995.tb00557.x · Cited by 2
Evaluation of the VMM Turbine for Spirometry in the Applied Physiology Laboratory
Smith, W. D. F., Cunningham, D. A., Paterson, D. H., & Rechnitzer, P. A. (1993) · Canadian Journal of Applied Physiology · doi:10.1139/h93-027 · Cited by 2
Regulation of aortic wall mechanics and stress An experimental study in man
Åstrand, H. (2008) · DiVA (Linkoping University) · Cited by 3
Al-dameh, A. (2011) · Otago University Research Archive (University of Otago) · Cited by 2
A comparative study of glucose meter accuracy during biochemical hypoglycaemia in humans
Thomson, G., Galloway, P. J., Murdoch, J., Fisher, B. M., & Semple, C. G. (1998) · Practical Diabetes · doi:10.1002/pdi.1960150504 · Cited by 2
Fonseca, P. (2012) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/6trr-0566 · Cited by 4
Techniques for Studying Arterial Elastic Properties
Cohn, J. N. (2002) · Hypertension · doi:10.1161/hyp.39.3.e20 · Cited by 2
Valuation of quality of life in rheumatoid arthritis
Buitinga, L. (2012) · doi:10.3990/1.9789036534673 · Cited by 2
Lora, K. R. (2008) · Lincoln (University of Nebraska) · Cited by 2
Hydraulic Bench Testing of the TruCATHTM/TruCCOMTM Continuous Cardiac Output Monitor
Segers, P., Vandenberghe, S., Decruyenaere, J. M. A., Poelaert, J., Wouters, P. F., Colardyn, F., & Verdonck, P. (2003) · Cardiovascular Engineering An International Journal · doi:10.1023/b:care.0000015101.72782.a7 · Cited by 2
INFLAMMATORY MARKERS AS NOVEL PREDICTORS OF CARDIOVASCULAR DISEASE
Welsh, P. I. (2008) · Enlighten: Theses (The University of Glasgow) · Cited by 4
Smythe, M. A., Koerber, J. M., Westley, S. J., Balasubramaniam, M., & Mattson, J. C. (2001) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2001-125-1458-dhl · Cited by 2
Is movement variability relevant for the elite golfer? A biomechanical and modelling perspective
Tucker, C. B. (2012) · Arrow@dit (Dublin Institute of Technology) · doi:10.34961/6384 · Cited by 3
Renström, A. (1997) · Gothenburg University Publications Electronic Archive (Gothenburg University) · Cited by 2
The Significance of Hypothermia in Preserving Ischemic Myocardium
Futterman, L. G., & Lemberg, L. (2004) · American Journal of Critical Care · doi:10.4037/ajcc2004.13.1.79 · Cited by 2
Clinical evaluation of a partial CO2 rebreathing technique
Berthelsen, P. G. (2002) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2002.460922_1.x · Cited by 2
Lack of agreement between tonometric and gastric juice partial carbon dioxide tension
Dubín, A., Badie, J., Fernandez, S., Estenssoro, E., Canales, H. S., Bordoli, G., & Pálizas, F. (2000) · Critical Care · doi:10.1186/cc701 · Cited by 2
Jorgensen, R. A. (2010) · University of Minnesota Digital Conservancy (University of Minnesota) · Cited by 3
Estimación y evaluación de Modelos estructurales centro-periferia.
Muñiz, A. S. G., Carvajal, C. R., Herrero, R. Á., & Vázquez, E. F. (2004) · Redes Revista hispana para el análisis de redes sociales · doi:10.5565/rev/redes.56 · Cited by 2
Accuracy of venous blood oxygen pressure depends on arterial blood oxygen pressure
Zavorsky, G. S. (2009) · European Respiratory Journal · doi:10.1183/09031936.00097909 · Cited by 2
Sims, A. J., Pemberton, J., Irvine, T., Kenny, A., & Murray, A. (2003) · Computers in cardiology · doi:10.1109/cic.2002.1166781 · Cited by 2
Limits of agreement between raters are required for the use of HJHS 2.1 in clinical studies
Fischer, K. (2014) · Haemophilia · doi:10.1111/hae.12586 · Cited by 2
Uesugi, F., Inada, T., Inada, K., Kawachi, S., & Matsuda, M. (1996) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(96)80128-5 · Cited by 2
Individual, behavioural and environmental pathways to adolescent obesity
Chivers, P. (2010) · ResearchOnline@ND (The University of Notre Dame) · Cited by 4
Nakamura, T., Kimura, H., Katô, M., Kurashige, S., & Wakamatsu, K. (2006) · Cell Biology International · doi:10.1016/j.cellbi.2006.10.009 · Cited by 2
Ivey, L., Thom, J. Y., & Baker, R. I. (1997) · Pathology · doi:10.1080/00313029700169574 · Cited by 2
Chemiluminescent Assay for Serum Thyroglobulin in the Management of Patients with Thyroid Carcinoma
Perry, L., & Dawnay, A. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.4.778 · Cited by 2
From Sample to Population: Using and Reporting Inferential Statistics
Parker, C., & Drummond, A. E. (2006) · British Journal of Occupational Therapy · doi:10.1177/030802260606900104 · Cited by 2
The function of left ventricular basal segments is most important for long-term recovery
Täng, M. S., Waagstein, F., & Andersson, B. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2006.11.014 · Cited by 2
Fraction of Carbon-Free Body Mass as Oxygen Is a Constant Body Composition Ratio in Men
Wang, Z., Deurenberg, P., Wang, W., Pierson, R. N., & Heymsfield, S. B. (1998) · Journal of Nutrition · doi:10.1093/jn/128.6.1008 · Cited by 2
Huang, J., Wang, Q., & Savini, G. (2012) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2011.11.028 · Cited by 2
Half-night polysomnography: how is it compared to full-night polysomnography?
Chung, K. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.12030748 · Cited by 2
Siconolfi, S. F., Gretebeck, R. J., Wong, W. W., Moore, S. S., & Gilbert, J. H. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.4.1578 · Cited by 3
Tissue perfusion and metabolism during intra-abdominal hypertension
Maddison, L. (2014) · DSpace repository (University of Tartu) · Cited by 2
CT-based measurement of lung volume and attenuation of deceased
Sylvan, E. (2005) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 2
Sloth, M. V. E. (1998) · Scandinavian Cardiovascular Journal · doi:10.1080/14017439850139852 · Cited by 2
Kroff, J. (2005) · SUNScholar (Stellenbosch University) · Cited by 4
Portable biomedical devices: a critical issue during telecare services design
Gortzis, L. G., Bakettas, I., Makropoulos, C., Graschew, G., & Nikiforidis, G. (2008) · Informatics for Health and Social Care · doi:10.1080/17538150802127165 · Cited by 2
Janaudis‐Ferreira, T. (2010) · DiVA at Umeå University (Umeå University) · Cited by 12
Blood Pressure in Pediatric Chronic Kidney Disease—It’s in the Ears of the Beholder
McBryde, K. D. (2011) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2011.10.004 · Cited by 2
Resting energy expenditure of children attending a rehabilitation programme following head injury
Littlewood, O. T. R. A. (2001) · Developmental Neurorehabilitation · doi:10.1080/13638490026412 · Cited by 2
Takahashi, S., Takamura, M., Yamamoto, S., Kudo, M., Narumi, Y., Murakami, T., & Nakamura, H. (2007) · Acta Radiologica · doi:10.1080/02841850601067645 · Cited by 2
Shetty, A. M., Stafford, R. J., Elliott, A. M., Kassouf, W., Brown, G. A., Stephens, L. C., Tinkey, P. T., Bidaut, L. M., Pisters, L. L., & Hazle, J. D. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21206 · Cited by 2
McCall, J. L., Funamoto, S., Yun, K., & Parry, B. R. (1991) · Australian and New Zealand Journal of Surgery · doi:10.1111/j.1445-2197.1991.tb00191.x · Cited by 2
Biomechanical evaluation of distance running during training and competition
Bridgman, C. F. (2015) · University of Salford Institutional Repository (University of Salford) · Cited by 10
Classic papers in nursing and midwifery research
Norman, I. J. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2010.05.013 · Cited by 2
Considerations for Evaluating the Accuracy of Hemoglobin Monitoring
O’Reilly, M. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31825d95d6 · Cited by 2
Gilmore, E. D. (2005) · British Journal of Ophthalmology · doi:10.1136/bjo.2005.074682 · Cited by 2
ICODEXTRIN METABOLISM IN PERITONEAL DIALYSIS: CLINICAL AND EXPERIMENTAL STUDIES
López, E. G. (2007) · Figshare · Cited by 2
Assessing the consistency of bladder filling using an ultrasonic Bladderscan® device
Dudley, N. J. (2012) · British Journal of Radiology · doi:10.1259/bjr/24030690 · Cited by 2
Advantages and Limitations of Intracoronary Ultrasound for the Assessment of Vascular Dimensions
Mario, C. D., Escaned, J., BAPTISTA, J., Haase, J., Ozaki, Y., Roelandt, J. R. T. C., & Serruys, P. W. J. C. (1994) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.1994.tb00889.x · Cited by 2
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.