STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 43,701–43,800 of 47,868
Determinação ultra-sonográfica do sexo fetal pela medida dos ângulos do apêndice genital
Bunduki, V., Brizot, M. D. L., Miguelez, J., Peralta, C. F. A., Veja, A. J. M. D. L., & Zugaib, M. (2005) · Revista Brasileira Ginecologia e Obstetrícia · doi:10.1590/s0100-72032005000600004
Resolving Problems in Expiratory Gas Analysis
Kamimura, S., & Akiyama, S. (2009) · Rigakuryoho Kagaku · doi:10.1589/rika.24.941
Tomás, F. J. G., Comas, I., Dot-Bach, D., de la Presa, B. G., Borrell, J. M., Morales‐Romero, B., Santos, D. P., Álvarez, J. S., & Morist, S. T. (2013) · Revista del Laboratorio Clínico · doi:10.1016/j.labcli.2013.10.003
Clinically useful samples and reference change value
Kutasz, E., Lazzati, J. M., Maceiras, M., Zaidman, V., Rubinstein, M., & Chaler, E. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0657
Wavelets based algorithm for the evaluation of enhanced liver areas
Alvarez, M., de Pina, D. R., Giacomini, G., Romeiro, F. G., Duarte, S. B., Yamashita, S., & Miranda, J. R. D. A. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2043822
Gennart, F., Beckers, S., Verborgh, C., Baerdemaeker, A. D., & Poelaert, J. (2012) · Critical Care · doi:10.1186/cc10828
Gonçalves, E. M., Silva, A. M., Matias, C. N., de Lemos‐Marini, S. H. V., Santos, A. O., & Guerra‐Júnior, G. (2012) · Clinical Nutrition · doi:10.1016/j.clnu.2012.05.007
Wendland, A. E., de Azevedo, M. J., Gross, J. L., & Camargo, J. L. (2007) · Jornal Brasileiro de Patologia e Medicina Laboratorial · doi:10.1590/s1676-24442007000600002
Chabanova, E., Bille, D. S., Thisted, E., Holm, J., & Thomsen, H. S. (2012) · Journal of Biomedical Graphics and Computing · doi:10.5430/jbgc.v3n1p35
Analysis of mean transcutaneous capnography in consecutive patients undergoing polysomnography
Pinnola, G. C., & Bastos, P. S. (2014) · Arquivos de Neuro-Psiquiatria · doi:10.1590/0004-282x20140138
Seo, K.-S., Sim, M.-H., Kim, M.-Y., Yoon, C.-S., Chung, J.-H., Park, S.-B., & Yoon, H.-R. (2012) · The Transactions of The Korean Institute of Electrical Engineers · doi:10.5370/kiee.2012.61.12.1932
Gutberlet, M., Krieghoff, C., Barten, M. J., Hildebrand, L., Grothoff, M., Lehmkuhl, L., Luecke, C. F., Andres, C., & Mohr, F. W. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-16-s1-p276
Ou, P., Zhao, Y., Elfawal, S. K., Banka, P., & Powell, A. J. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-s1-p302
Variation in the measurement of fetal abdominal circumference
Wheeler, T., Elfes, C., & Anthony, F. W. (1990) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1990.tb02532.x
Buranarugsa, R. (2012) · The Open Sports Sciences Journal · doi:10.2174/1875399x01205010154 · Cited by 2
Barbier, O., Skalli, W., Mainard, L., & Mainard, D. (2014) · Revue de Chirurgie Orthopédique et Traumatologique · doi:10.1016/j.rcot.2014.07.006
Modified sensor for pulse oximetry in children
Newson, C. (1994) · Anaesthesia · doi:10.1111/j.1365-2044.1994.tb04481.x
Morita, C., Nakatsu, T., Kusachi, S., Kitawaki, T., Usui, S., Tobe, K., Toyonaga, S., Ogawa, H., Hirohata, S., & Shiratori, Y. (2007) · Journal of Medical Ultrasonics · doi:10.1007/s10396-006-0126-7
Capillary plasma lipid profiles
Mace, R., May, B., McCray, C., Tracy, T., Speirs, J., & Glueck, C. J. (1991) · Clinica Chimica Acta · doi:10.1016/0009-8981(91)90230-a
Implications of Turbulence Slope Variations in Different Approaches
Chen, H. Y. (2011) · Heart International · doi:10.4081/hi.2011.e7
Salim, A., Nacamuli, R. P., & Longaker, M. T. (2004) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200405000-00011
EuroSCORE reliability: is the ejection fraction as objective as presumed?
Torp, P., Sloth, E., & Jakobsen, C.-J. (2005) · European Journal of Anaesthesiology · doi:10.1097/00003643-200506001-00012
Brander, P. E. (1994) · Journal of Sleep Research · doi:10.1111/j.1365-2869.1994.tb00105.x
Faisy, C., Rabbat, A., Kouchakji, B., Doré, M., & Laaban, J. P. (2001) · Nutrition Clinique et Métabolisme · doi:10.1016/s0985-0562(01)00057-7
Monitoraggio cardiovascolare dell’operato in chirurgia non cardiaca
Desebbe, O., Keller, G., Carre, A.-C., & Lehot, J.-J. (2013) · EMC - Anestesia-Rianimazione · doi:10.1016/s1283-0771(13)64500-4
Lomas, D. J., Britton, P. D., Summerton, C. B., & Seymour, C. A. (1994) · Clinical Radiology · doi:10.1016/s0009-9260(05)81890-2
Choix d'un automate d'hémostase
Abecassis, L., & Hamon, C. (2007) · Revue Francophone des Laboratoires · doi:10.1016/s1773-035x(07)80262-0
Lee, P.-J., Lee, Y.-J., Kim, K., Lee, J., Lim, M. K., & Lee, J. (2012) · The Transactions of The Korean Institute of Electrical Engineers · doi:10.5370/kiee.2012.61.6.885
Kim, M. K., Park, W. J., & Park, C. H. (2005) · Korean Circulation Journal · doi:10.4070/kcj.2005.35.11.854
Pascal, P., Bailliez, A., Blaire, T., Agostini, D., & Manrique, A. (2013) · Médecine Nucléaire · doi:10.1016/j.mednuc.2013.01.003
Long, A., Rouet, L., Vitry, F., Albertini, J. N., Marcus, C. D., & Clément, C. (2009) · Annales de Chirurgie Vasculaire · doi:10.1016/j.acvfr.2009.04.008
Gould, N., Møller, J., & Andrieux, L. (2008) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2007.007130
Gyermek, L. (1997) · Journal of Clinical Monitoring and Computing · doi:10.1023/b:jocm.0000012480.32738.8e
How sensitive are cardiac surgeons' fingers?: FIG
Angelini, G. D., Izzat, M. B., Bryan, A. J., & West, R. R. (1994) · BMJ · doi:10.1136/bmj.309.6970.1685
Zdravkovic, M., Christiansen, T., Grosch, K., & Ilondo, M. M. (2000) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2000.114
MEASUREMENT OF LYMPHEDEMA USING A SIMPLE DEVICE
Imran, D., & Mandal, A. (2003) · Plastic & Reconstructive Surgery · doi:10.1097/01.prs.0000100612.13447.c3
Valsecchi, S., Perego, G. B., Schreuder, J. J., Censi, F., & Jansen, J. R. C. (2007) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-007-9078-8
Chalmers, H., Scrivani, P. V., Dykes, N. L., Hubble, L. J., Hobbs, J. M., & Erb, H. N. (2007) · American Journal of Veterinary Research · doi:10.2460/ajvr.68.4.354
Overweight and Health-Related Factors Among Adolescents: The HBSC Portuguese Study
Fonseca, H., & de Matos, M. G. (2010) · Journal of Adolescent Health · doi:10.1016/j.jadohealth.2009.11.098 · Cited by 1
Veyrat, C., Beuve, D. S., Yafi, W. E., Sebaoun, G., & Kalmanson, D. (1994) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(94)90043-4
Evaluation of arterial propagation velocity based on the automated analysis of the Pulse Wave Shape
Clara, F., Scandurra, A. G., Meschino, G. J., & Passoni, L. I. (2011) · Journal of Physics Conference Series · doi:10.1088/1742-6596/332/1/012014
Reproducibility of Ambulatory Blood Pressure Monitoring Results in Pregnancy
Livi, R., Teghini, L., Parretti, E., Detti, L., & Mello, G. (1998) · American Journal of Hypertension · doi:10.1016/s0895-7061(98)00040-5
Diagnosis of the acute ischaemic heart by ion elution from myocardium
Reid, W. A., Brown, D., Purves, D. A., & Barnes, I. P. (1992) · The Journal of Pathology · doi:10.1002/path.1711670208
Diagnoses of coaxial probes in shock compression
Sun, Y., Ci, J., Peng-fei, Y., & Zhang, H. (2009) · Review of Scientific Instruments · doi:10.1063/1.3145239
Brodt, G. A. (2011) · Lume (Universidade Federal do Rio Grande do Sul)
Is Equivalent Truly Equivalent?
Cesana, B. M., & Ulivieri, F. M. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.8.1468
Vanhercke, D., Claessens, T. E., Vandekerckhove, H. J., Tricht, I. V., Segers, P., & Verdonck, P. (2006) · Echocardiography · doi:10.1111/j.1540-8175.2006.00209.x
Total Body Potassium in Healthy Italians and Americans: A Cross‐Calibration Study
LORENZO, A. D., Andréoli, A., Puja, A., Wang, J., & Pierson, R. N. (2000) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2000.tb06483.x
den Broeck, J. V., Brestoff, J. R., & Chhagan, M. K. (2013) · Springer eBooks · doi:10.1007/978-94-007-5989-3_6
Isioye, O. A. (2014) · Positioning · doi:10.4236/pos.2014.51004
A previsibilidade biométrica nas lentes intra-oculares multifocais
Lacava, A. C., Caballero, J. C., & Centurión, V. (2007) · Revista Brasileira de Oftalmologia · doi:10.1590/s0034-72802007000400006
Chirino, L. R., Viana, J., Bento, S., Costa, G., Tomé, R., & Oliveira, F. (2006) · European Journal of Anaesthesiology · doi:10.1097/00003643-200606001-00725
van Prehn, J., Bartels, L. W., Mestres, G., Vincken, K. L., Prokop, M., Verhagen, H. J. M., Moll, F. L., & van Herwaarden, J. A. (2009) · Anales de Cirugía Vascular · doi:10.1016/j.acvsp.2008.08.024
Bland-Altman analysis for pupillometer comparison
Brown, S. M. (2010) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2010.08.001
Ornetti, P., Maillefert, J.-F., Paternotte, S., Dougados, M., & Gossec, L. (2011) · Revue du Rhumatisme · doi:10.1016/j.rhum.2011.02.002
Reproductibilité de la mesure des principaux angles de coxométrie chez l’adulte
Bouttier, R., Morvan, J., Mazières, B., Rat, A., Ziegler, L. E., Fardellone, P., Fautrel, B., Guillemin, F., Pouchot, J., Roux, C. H., et al. (2012) · Revue du Rhumatisme · doi:10.1016/j.rhum.2012.01.004
Jeong, N.-H., Yang, K.-Y., Seol, H., & Jung, E. H. (2012) · Korean Journal of Obstetrics & Gynecology · doi:10.5468/kjog.2012.55.7.454
Repeatability of the Visual Manipulation Test
Kulp, M. T., & Edwards, K. (2000) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2000.tb01071.x
Improved illumination for the Perkins applanation tonometer
Ressiniotis, T., Zeki, S. M., Clarke, M. W., & Mitchell, K. W. (2003) · Ophthalmic and Physiological Optics · doi:10.1046/j.1475-1313.2003.00146.x
Gandia, P., Koraïchi, F., Kamar, N., Rostaing, L. P. E., du Rieu, Q. C., Lavit, M., & Houin, G. (2011) · Annales de Toxicologie Analytique · doi:10.1051/ata/2011125
Dosage of inhaled nitric oxide: a simple method for experimental studies
Ney, L., Kemming, G., Kuebler, W. M., Sckell, A., & Goetz, A. E. (1999) · Research in Experimental Medicine · doi:10.1007/s004330050117
Reliability and validity of a computer-based little irregularity index: Authors' response
Tran, A. M., Hatch, J. P., Prihoda, T. J., & Rugh, J. D. (2003) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/s0889-5406(03)00557-2
Evaluation of the Wisecheck Glucose Monitoring System
Kwon, S., Kim, H. N., Ko, S.-Y., Cho, C. H., Kim, J. S., & Lim, C. S. (2014) · Laboratory Medicine Online · doi:10.3343/lmo.2014.4.1.15
Pitfalls in measuring high‐density lipoprotein cholesterol concentrations in HIV‐infected patients
Aragonès, G., Beltrán‐Debón, R., Rull, A., Marsillach, J., Rodríguez, F., Alí, S., Fernández-Sénder, L., Camps, J., Joven, J., & Alonso‐Villaverde, C. (2009) · HIV Medicine · doi:10.1111/j.1468-1293.2009.00772.x
Repeatability of Spectral Domain OCT (3D-OCT 1000) in Normal Subjects and Various Macular Diseases
Moon, S. W., Lee, J. M., Song, Y. M., Cho, H. Y., & Lee, B. R. (2010) · Journal of the Korean Ophthalmological Society · doi:10.3341/jkos.2010.51.4.524
Saraux, A., Alcalay, M., Audran, M., Boissier, M., Cantagrel, A. G., Chevalier, X., Dougados, M., Duquesnoy, B., Flipo, R. M., Goupille, P., et al. (2004) · Revue du Rhumatisme · doi:10.1016/j.rhum.2004.08.002
Hellstern, P. (2001) · Intensivmedizin und Notfallmedizin · doi:10.1007/s003900170002
Nevière, R., Mathieu, D., Hérengt, F., Riou, Y., Chagnon, J. L., Guimiez, P., Renaud, N., & Wattel, F. (1993) · Réanimation Urgences · doi:10.1016/s1164-6756(05)80485-2
Conventional Audiometry Versus Cochlear Microphone Audiometry
Juaristi, J. S. (2007) · Acta Otorrinolaringologica (English Edition) · doi:10.1016/s2173-5735(07)70322-8
Faulkner, J., & Lambrick, D. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1525-4 · Cited by 1
RetractedJoly, L., Guyomarc’h, L., Damm, C., Dureuil, B., & Veber, B. (2011) · Annales Françaises d Anesthésie et de Réanimation · doi:10.1016/j.annfar.2011.07.019
S40.5: Relative validation of a physical activity questionnaire with appropriate statistical methods
Schmidt, M., & Steindorf, K. (2004) · Biometrical Journal · doi:10.1002/bimj.200490142
Wang, S., Lin, A. T., & Lin, C. (2007) · Neurourology and Urodynamics · doi:10.1002/nau.20237
Santos-Martínez, L. E., Guevara-Carrasco, M., Ricoy, G. L. N., Baranda-Tovar, F. M., Moreno-Ruíz, L. A., Herrera-Velázquez, M. A., Magaña‐Serrano, J. A., Valencia-Sánchez, J. S., & Calderón-Abbo, M. C. (2014) · Archivos de cardiología de México · doi:10.1016/j.acmx.2013.11.005
The optimisation of the energy-related cost function for the Delft Shoulder & Elbow Model
Wijk, M. P. R. V. (2011)
Monitorización cardiovascular en cirugía no cardíaca
Desebbe, O., Keller, G., Carre, A.-C., & Lehot, J.-J. (2013) · EMC - Anestesia-Reanimación · doi:10.1016/s1280-4703(13)64515-6 · Cited by 1
Response to Is the Aldosterone:Renin Ratio Truly Reproducible?
Rossi, G. P., Seccia, T. M., & Pessina, A. C. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.149880
Serio, F. D., Trerotoli, P., Varraso, L., Mazzarella, A., Specchia, I., & Pansini, N. (2004) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/00134384-200412000-00010
Part 6: Statistics in orthopaedics
Pipkin, F. B. (1993) · Current Orthopaedics · doi:10.1016/0268-0890(93)90009-g
Thompson, S., Warren, R. J., Ryan, C., & Jolley, D. (1995) · Serodiagnosis and Immunotherapy in Infectious Disease · doi:10.1016/0888-0786(96)87296-9
Evans, D. W., & Raj, M. (1986) · Heart · doi:10.1136/hrt.56.1.106-a
Estimation of the proportion of body fat in mice from the proportion of body water
Terpstra, A. H. M. (2003) · Journal of Animal Physiology and Animal Nutrition · doi:10.1046/j.1439-0396.2003.00413.x
Nickl, W., Bugaj, T. J., Mondritzki, T., Kuhlebrock, K., Dinh, W., Krahn, T., Sohler, F., & Truebel, H. (2011) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2011.014
Takahashi, S., Chiba, T., Ishii, H., & Nishijima, T. (2005) · International Journal of Sport and Health Science · doi:10.5432/ijshs.3.68
Central venous versus mixed venous oxygen saturation in patients undergoing cardiac surgery
Lorenzen, A.-G., & Christiansen, C. L. (2005) · European Journal of Anaesthesiology · doi:10.1097/00003643-200506001-00067
Opioid-taking self-efficacy in Taiwanese Outpatients with cancer pain
Liang, S. (2007) · Faculty of Health
Validation of commercial cardiac output computers in a flow model
Bühre, W., Weyland, A., Weyland, W., Wietasch, G. J. K. G., Allgeier, B., Schorn, B., & Sonntag, H. (1994) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/1053-0770(94)90582-7
Exploration hémodynamique invasive du ventricule droit
Saulnier, F., Durocher, A., Cadélis, G., Hérengt, F., & Wattel, F. (1992) · Réanimation Urgences · doi:10.1016/s1164-6756(05)80191-4
Bone imaging and strength in chronic obstructive pulmonary disease
Romme, E. A. (2014) · Research Publications (Maastricht University) · doi:10.26481/dis.20140220er
Photometric haemoglobin assessment
Kerkkamp, H. E. M. (1997) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03014469
Mahmud, A., Jatoi, N. A., & Feely, J. (2009) · Artery Research · doi:10.1016/j.artres.2009.10.008 · Cited by 1
Journois, D., Donnadieu, S., Bacchi, B., Dru, M., & Safran, D. (1993) · Annales Françaises d Anesthésie et de Réanimation · doi:10.1016/s0750-7658(05)80648-3
Cerebral blood flow thermodilution measurements
Berré, J., Mélot, C., & Moraine, J.-J. (1998) · European Journal of Anaesthesiology · doi:10.1097/00003643-199801001-00040
van Rossum, L. K., Cransberg, K., Mathôt, R. A. A., & Vulto, A. G. (2005) · Tijdschrift voor kindergeneeskunde · doi:10.1007/bf03061548
Mesure de la température chez le nouveau-né: l'après-mercure
Semama, D. S., & Gouyon, J. (1999) · Archives de Pédiatrie · doi:10.1016/s0929-693x(99)80304-2
Evaluación de la medición de bilirrubina total en el analizador GEM® Premier™ 4000
Salán, M. E., Valtuille, C. P., Navarro, S. D. C., & Uranga, M. R. (2012) · Revista del Laboratorio Clínico · doi:10.1016/j.labcli.2012.01.002
The accuracy of transcutaneous bilirubin measurements in preterm infants
Alsafadi, T., & Alsaedi, S. (2015) · Journal of Clinical Neonatology · doi:10.4103/2249-4847.151160
Oh, S. B., Moon, J. W., & Kim, H. C. (2010) · Journal of the Korean Ophthalmological Society · doi:10.3341/jkos.2010.51.3.372
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.