Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 43,501–43,600 of 47,868
Accuracy of Temporal Artery Thermometry in Neonatal Intensive Care Unit Infants
Rollins, K., & Flannery-Bergey, D. (2011) · Journal of Obstetric, Gynecologic & Neonatal Nursing · doi:10.1111/j.1552-6909.2011.01243_33.x
Pathogenese der Trichterbildung der Urethra bei Frauen mit Streßharninkontinenz
Goldammer, K. (2001) · edoc Publication server (Humboldt University of Berlin) · doi:10.18452/14642
Bowman, L., & Loucks, A. B. (2007) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/86.4.1251
Bressollette, L. (2012) · OhioLink ETD Center (Ohio Library and Information Network)
Both, D. R., Matheus, S. C., Martins, G. Q., & Behenck, M. S. (2014) · Revista de Salud Pública · doi:10.15446/rsap.v16n3.39931
Breaks in sedentary time in young children : measures and methodological issues
Alghaeed, Z. (2014) · Enlighten: Theses (The University of Glasgow)
Grewar, J. D. (2009) · UpSpace Institutional Repository (University of Pretoria)
Topics in Atrial Fibrillation Management
SCHOLTEN, M. F. (2006) · RePub (Erasmus University Rotterdam)
The Measurement of Sporting Performance using Mobile Physiological Monitoring Technology
Johnstone, J. (2014) · University of Hertfordshire Research Archive (University of Hertfordshire) · doi:10.18745/th.13527 · Cited by 1
Total Body Water (TBW) for Body Composition Assessment in Young Adult Females from Colombia
González-Correa, C. H., Caicedo-Eraso, J. C., & Gallagher, D. (2015) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-287-928-8_11
Seele, M. (2007) · SUNScholar (Stellenbosch University)
Clifford, E. (2011) · Arrow@dit (Dublin Institute of Technology) · doi:10.34961/1191
Klinimetrie van meten van bewegingsuitslagen van de knie
Lenssen, A. F. (2009) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-313-6912-6_8
Conrick-Martin, I., McGovern, M. M., Boner, K., Bourke, J., Fitzgerald, E., Hone, R., Lynch, M., Phelan, D. M. J., & Walshe, C. M. (2013) · Critical Care · doi:10.1186/cc11988
Couper, K. (2026) · Warwick Research Archive Portal (University of Warwick) · doi:10.82444/warw.33689812
Corneal nerve structure and function as markers of diabetic neuropathy
Pritchard, N. (2012) · Faculty of Health; Institute of Health and Biomedical Innovation
Stéphan, D., Tavera, C., Raponsky, J., Moreau, S., Weltin, D., Düver, S., Jeanne, J. F., Ziani, E., & Chauveau, M. (2000) · Phlebology The Journal of Venous Disease · doi:10.1007/s005230070006
Pineau, V., Lebel, B., Gouzy, S., Dutheil, J.-J., & Vielpeau, C. (2010) · Revue de Chirurgie Orthopédique et Traumatologique · doi:10.1016/j.rcot.2010.06.008
Kar, J., Knutsen, A. K., Cupps, B. P., & Pasque, M. K. (2014) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.553.350
Evaluation of Diagnostic Device for Obstructive Sleep Apnea
Cunnington, D. (2003) · CHEST Journal · doi:10.1378/chest.124.4.1623
Lamivudine plasma levels in chronic hepatitis B patients.
Wolters, L. M. M., Geerlings, C. J. C., van Dijk, L., Niesters, H. G. M., Vulto, A. G., & de Man, R. A. (2003) · PubMed
Bard, R. L., & Nicklas, J. M. (2006) · Journal of Cardiopulmonary Rehabilitation · doi:10.1097/00008483-200611000-00008
Saito, K., Okura, H., Obase, K., Imai, K., Tamada, T., Hayashida, A., Neishi, Y., Kawamoto, T., & Yoshida, K. (2011) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(11)60703-1
Tyrakowski, M., Czubak, J., & Siemionow, K. B. (2015) · European Spine Journal · doi:10.1007/s00586-015-3954-6
Hypercapnia as the influencing factor of pulse oximetry
Hinkelbein, J., & Genzwuerker, H. V. (2008) · European Respiratory Journal · doi:10.1183/09031936.00114608
Comments on ‘Does the type of creatinine assay affect creatinine clearance determination?’
Kallner, A. (2015) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2014.1003249
Meng, D. (2011) · University Library - University of Saskatchewan (University of Saskatchewan)
Statistics in Diabetic Medicine
Hollis, S. (1995) · Diabetic Medicine · doi:10.1111/j.1464-5491.1995.tb00437.x
Demura, S., Yamaji, S., Yamada, T., & Minami, M. (2008) · European Journal of Sport Science · doi:10.1080/17461390801988008
Sangali, E. B., Campos, E. Z., Castoldi, R. C., Fernandes, R. A., Júnior, I. F. F., & Júnior, P. B. (2012) · journal of physical education · doi:10.4025/reveducfis.v23i3.14283
Magosaki, E., Schäfer, D. M., Magosaki, N., Handke, M., Heinrichs, G., Sch�chlin, A., Brink, I., Bode, C., & Geibel, A. (2004) · Journal of Medical Ultrasonics · doi:10.1007/s10396-004-0011-1
Ali, S., & van Besouw, J. P. (2001) · European Journal of Anaesthesiology · doi:10.1097/00003643-200107001-00054
An Examination of body composition measurement methods in children
Kaplan, R. (2009) · Digital Scholarship - UNLV (University of Nevada Reno) · doi:10.34917/2296618
Exploring Intestinal Ischemia : An experimental study
Fröjse, R. (2005) · DiVA at Umeå University (Umeå University) · Cited by 1
Radial strain assessment of the interventricular septum wall by a new technique in healthy subjects
Moladoust, H., Mokhtari‐Dizaji, M., Ojaghi‐Haghighi, Z., D’hooge, J., Noohi, F., Khaledifar, A., & Khajavi, A. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0222-x
Fregonasse, T., Bottaro, M., Novaes, J. D. S., Oliveira, R., & de Melo, G. F. (2003) · Fitness & Performance Journal · doi:10.3900/fpj.2.2.97.s
Comparison between methods of tonometry: time for a change of approach.
Holtedahl, K. A., Christoffersen, T., Fors, T., & Ringberg, U. (1993) · British Journal of Ophthalmology · doi:10.1136/bjo.77.11.754-a
Clinical estimation of fetal weight in labour by mothers and midwives
Nwosu, E. C., Welch, C. R., Manasset, P., Gazvanit, K., & Walkinshaw, S. A. (1996) · Journal of Obstetrics and Gynaecology · doi:10.3109/01443619609030078
Barral, M., Soyer, P. A., Hassen, W. B., Gayat, É., Aout, M., Chiaradia, M., Rahmouni, A., & Luciani, A. (2013) · Journal de radiologie diagnostique et interventionnelle · doi:10.1016/j.jradio.2012.09.013
An easier alternative to orthogonal regression for calculation of International Sensitivity Indexes.
Taberner, D. A., & Dufty, J. M. (1995) · Journal of Clinical Pathology · doi:10.1136/jcp.48.10.901
Epi-aortic Doppler measurement of cardiac output in univentricular connection
Bogers, A. J. J. C. (2009) · Medical Devices Evidence and Research · doi:10.2147/mder.s4666
Südkamp, M., Cremers, B., Böhm, M., Mehlhorn, U., Magalski, A., Harrison, M., Erdmann, E., & de Vivie, E. R. (2002) · Zeitschrift für Herz- Thorax- und Gefäßchirurgie · doi:10.1007/s00398-002-0365-x
Quantification of evacuation proctography
Halligan, S., McGee, S., & Bartram, C. I. (1993) · Clinical Radiology · doi:10.1016/s0009-9260(05)81314-5
Poster 070: Accuracy of a New Technique for Recording Natural Head Position in 3 Dimensions
Xia, J. J. (2008) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2008.05.224
Albini, L., Focà, E., Motta, D., Gotti, D., Lapadula, G., Cesana, B. M., & Torti, C. (2012) · AIDS Research and Human Retroviruses · doi:10.1089/aid.2011.0243
da Silva, L. M., Vianna, P. T. G., Takaku, M., Mizubuti, G. B., & Castiglia, Y. M. M. (2013) · Open Journal of Nephrology · doi:10.4236/ojneph.2013.34032
Liu, R. S. N. (2004) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2004.04.006
Measurement of systolic blood pressure with a pulse oximeter
Chawla, R., Indrayan, A., Bhattacharya, A., Talke, P. O., Nichols, R. J., & Traber, D. L. (1992) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf01617436
Lee, D. S. (2012) · Research Online (University of Wollongong)
Maeda, Y., Araki, Y., Uno, T., Yoshida, A., Nishigaki, K., Inaba, N., Hayashi, H., & Deguchi, Y. (2011) · Journal of Rural Medicine · doi:10.2185/jrm.6.9
Validity of Expired Gas Dynamics Model during Intermittent Load Exercise
Takahashi, S., Chiba, T., Ishii, H., & Nishijima, T. (2005) · International Journal of Sport and Health Science · doi:10.5432/ijshs.3.57
Witt, V., Scharner, D., Printz, D., Pötschger, U., Fritsch, G., & Gadner, H. (2001) · Transfusion Medicine and Hemotherapy · doi:10.1159/000050258
Thierry, S., Thébert, D., Brocas, E., Razzaghi, F., Vermès, E., de Louw, A. V., & Tenaillon, A. (2004) · Annales Françaises d Anesthésie et de Réanimation · doi:10.1016/j.annfar.2004.06.012
Radiological Analysis of Human Hand in Terms of Artistic Anatomy
YILMAZ, A., Alıcıoğlu, B., Süt, N., Uluçam, E., & Çıkmaz, S. (2010) · Turkiye Klinikleri Journal of Medical Sciences · doi:10.5336/medsci.2008-9789
¿Dónde y cuándo colocar el termómetro de mercurio? Resultados de una comparación
de la Rubia, J. A. D. L. R., Vilar, A. M. F., Higuera, C. P., & Jaime, A. A. (2003) · Enfermería Clínica · doi:10.1016/s1130-8621(03)73823-6
The reliability of three-dimensional gait kinematics in healthy children
Skaaret, I., Fosdahl, M. A., Huse, A.-B., Beyer, K., & Røislien, J. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.10.253
Balsdon, M. E. R. (2012) · Scholarship@Western (Western University) · Cited by 2
Machado, F. A., de Moraes, S. M. F., Peserico, C. S., Mezzaroba, P. V., & Higino, W. P. (2012) · Motriz Revista de Educação Física · doi:10.1590/s1980-65742012000200010
RELIABILITIES OF HUMAN JUDGEMENTS: MEASUREMENTS FROM PHOTOGRAPHIC CT SCAN IMAGES
Pickersgill, M. J., Valentine, J. D., & Hart, G. C. (1998) · Psychological Reports · doi:10.2466/pr0.1998.82.1.171
Rejection of Erroneous Saturation Data in Optical Pulse Oximetry in Newborn Patients
Scalise, L., Marchionni, P., Carnielli, V. P., & Longo, L. (2011) · AIP conference proceedings · doi:10.1063/1.3626923
The effects of eccentrically biased versus conventional resistance training in older adults
Raj, I. S., Bird, S. R., Westfold, B. A., & SHIELD, A. J. (2011) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2011.11.046
Lauszus, F. F. (2006) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1080/00016340600969259
Accuraatheid en precisie van spirometers
Schermer, T. R., Verweij, E. H. A., Cretier, R., Pellegrino, A., & Poels, P. J. P. (2012) · Huisarts en Wetenschap · doi:10.1007/s12445-012-0192-6
Is the “instant flow” option on the NIOX ® analyser needed?
Malik, G., & Turner, S. (2006) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.02.002
Introduction of non-linearity by data transformation in method comparison and commutability studies
Stöckl, D., & Thienpont, L. M. (2008) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2008.342
Fregonasse, T., Bottaro, M., Novaes, J. D. S., Oliveira, R., & de Melo, G. F. (2003) · Fitness & Performance Journal · doi:10.3900/fpj.2.2.97.p · Cited by 1
Accuracy of computer-based quantification of aortic valve stenosis
Schöbel, W. A., Voelker, W., Obergfell, S., Haase, K. K., & Karsch, K.-R. (1998) · Catheterization and Cardiovascular Diagnosis · doi:10.1002/(sici)1097-0304(199805)44:1<16::aid-ccd5>3.0.co;2-a
Tobon‐Gomez, C., Butakoff, C., Ordás, S., Aguadé‐Bruix, S., & Frangi, A. F. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.708506
Szymanowicz, A., Bernay, A., Lornage, C., & Neyron, M.-J. (2009) · Immuno-analyse & Biologie Spécialisée · doi:10.1016/j.immbio.2009.07.002
Impedancia bioeléctrica como método para estimar cambios en los fluídos corporales en remeros
Rodríguez-Bies, E., Holway, F. E., González-Jurado, J. A., Saravia, F., Baños, Á. R., & de la Rosa, F. J. B. (2009) · Archivos de medicina del deporte: revista de la Federación Española de Medicina del Deporte y de la Confederación Iberoamericana de Medicina del Deporte
Clinical evaluation of the Braun BP 3000 Easy Click according to the ANSI/AAMI SP 10:2002
Nolly, H. L., Romero, M., Nolly, A., Silva, M., & Nolly, M. B. (2006) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000200485.57163.15
The Reliability Of An Isometric Test Based On Constant Perception Of Effort
Kilburn, S. M., & Cheung, S. S. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000353663.47754.64
Impedance cardiography [letter; comment]
Ng, H., & Walley, T. (1993) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1993.tb05900.x
KNECHT, S. D., Hopman, J. C. W., Daniëls, O., Stoelinga, G. B. A., Reneman, R. S., & Hoeks, A. P. G. (1989) · Heart · doi:10.1136/hrt.62.1.50
Gudjonsson, O., Sanz, E. J., Alván, G., Sm, A., & Reviriego, J. (1990) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1990.tb03781.x
A disposable blood pressure cuff. An assessment of its accuracy
Dodd, F., ARMSTRONG, P., RAY, D. C., & Scott, D. H. T. (1990) · Anaesthesia · doi:10.1111/j.1365-2044.1990.tb14394.x
Dahaba, A. A. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200212000-00087
Calderón, J. L. M., Pérez, J. V., Guadaño, F. B., & Gómez, J. C. S. (2013) · Revista del Laboratorio Clínico · doi:10.1016/j.labcli.2013.07.004
Letters to the Editor-in-Chief
Weber, C. L., & Schneider, D. A. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200110000-00029
A system for postoperative visualization and analysis of left ventricular pressure–volume loops
Beard, B. B., Stewart, J. R., & Fischell, T. A. (1998) · Computers in Biology and Medicine · doi:10.1016/s0010-4825(97)00045-0
Serrano, J. A., Robles, J. A. G., Fernández, E. G., & Domínguez, J. L. D. (1999) · Revista Española de Cardiología · doi:10.1016/s0300-8932(99)74957-2
Noninvasive assessment of intracranial pressure using functional matrix estimation method
Lee, H., Kim, H., Lee, D.-H., Yang, X. K., Jeong, E.-J., Park, D.-H., Kim, Y., & Kim, D. (2015) · International Winter Conference on Brain-Computer Interface (BCI) · doi:10.1109/iww-bci.2015.7073052
McSorley, S. T., Dani, K., Patterson, J., Brennan, D., Hadley, D. M., & Muir, K. W. (2012) · Open Journal of Radiology · doi:10.4236/ojrad.2012.23013
Daouk, J., Bailly, P., Fin, L., & Meyer, M.-É. (2010) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e32833d691a
The peak flow whistle: a simple device for monitoring peak flow in children.
Tsanakas, J. N., Bannister, O. M., Boon, A. W., & Milner, R. D. G. (1986) · BMJ · doi:10.1136/bmj.293.6559.1410
Yaqub, M. K., Ioannou, C., Javaid, M. K., Cooper, C. C., Papageorghiou, A. T., & Noble, J. A. (2013) · Fetal Diagnosis and Therapy · doi:10.1159/000354342
Non-exhaustive tests for critical power estimation
Nakamura, F. Y., Okuno, N. M., Perandini, L. A., Simões, H. G., Altimari, L. R., & Bishop, D. J. (2009) · Science & Sports · doi:10.1016/j.scispo.2009.04.003
Amount of error in a measurement?…Reliability
Yip, S., Sahota, D. S., & Lok, I. H. (2003) · Fertility and Sterility · doi:10.1016/s0015-0282(03)02174-5
Li, Y., Würgler‐Hauri, C. C., Schuppisser, M. C., Gerber, C., & Snedeker, J. G. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4023702
Qiao, H., Gai, L., Wang, M., He, B., Zhang, S., Yang, X., Jin, Q., & Guan, Z. (2012) · International journal of cardiac imaging · doi:10.1007/s10554-012-0157-7
Is there an agreement between central venous and coronary sinus pressures?
Yazigi, A. G., Gebara, S., Haddad, F., Hayeck, G., & Antakly, M.-C. (1998) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(98)90128-8
Accuracy of weighed dietary records.
Jackson, A. A., & Wootton, S. A. (1990) · BMJ · doi:10.1136/bmj.300.6732.1138-b
Drechsler, H., Masztalewicz, M., Safranow, K., & Nowacki, P. (2013) · Neurologia i Neurochirurgia Polska · doi:10.5114/ninp.2013.35574
Eureka! A reliable, home-made water volumetry device
Kimmel, L. A., Prescott, J., Holland, A. E., & Bedi, H. S. (2014) · International Journal of Therapy and Rehabilitation · doi:10.12968/ijtr.2014.21.3.126
Hypertension Crisis in Adrenal Surgery and Treatment of Postoperative Hypotension
Otto, M., Dzwonkowski, J., Januszewicz, A., Pęczkowska, M., Kański, A., Kasperlik-Zaluska, A. A., Rosłonowska, E., & Szmidt, J. (2010) · Polish Journal of Surgery · doi:10.2478/v10035-009-0028-7
Vestibular Schwannoma: Optimizing Tumor Growth Monitoring by Volume Measurements
van de Langenberg, R., & Stokroos, R. J. (2012) · Springer eBooks · doi:10.1007/978-94-007-2894-3_26
Traitement des spondylarthropathies. Nouveautés et perspectives en 2001
Dougados, M. (2001) · Revue du Rhumatisme · doi:10.1016/s1169-8330(01)00209-5
Picard, F. A., Garçon, P., Chaudeurge, A., Simion, C., & Cador, R. (2014) · Annales de Cardiologie et d Angéiologie · doi:10.1016/j.ancard.2014.05.005
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.