STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 43,901–44,000 of 47,868
Müller, S. A. (2009) · Universitätsbibliothek der FU Berlin Hochschulschriftenstelle u. Dokumentenserver · doi:10.17169/refubium-14036
Jonathan, B., Liu, Q., Steele, B. N., Lucas, C. L., Dennis, R. G., & Lin, W. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22889
Effect of valve replacement for aortic stenosis on ventricular function
Zhao, Y. X. (2011) · DiVA at Umeå University (Umeå University) · Cited by 1
Assessing reproducibility of enzyme-linked immunosorbent assay serologic tests
Massé, J. (1996) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(96)00051-0
Chang, J.-B., Huang, C.-H., Chiu, J.-S., Chuang, M., Tien, H.-L., & Wang, Y. (2007) · 核子醫學雜誌 · doi:10.6332/anms.2004.004
Araújo, L. M. P. (2006) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.5.2006.tde-13092006-155555
Estimation of Uncertainty in Complex Biomeasurements
Cysewska-Sobusiak, A. R. (2007) · IEEE International Workshop on Advanced Methods for Uncertainty Estimation in Measurement (AMUEM) · doi:10.1109/amuem.2007.4362565
Monitoring of breathing tube position and patency in situ using reflected sound
Mansfield, J. P., & Wodicka, G. R. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1995.575313
MSX1 in relation to clefting. hypodontia and hydrocephaly in humans
van den Boogaard, M. H. (2013) · Utrecht University Repository (Utrecht University) · Cited by 1
Meningiomas and sex hormones, radiotherapy and benign brain tumours
Davis, C. (1991) · European Journal of Cancer and Clinical Oncology · doi:10.1016/0277-5379(91)90326-9
Clinical evaluation of pulse contour continuous cardiac output measurement
Scheffer, G. J., Ronday, M., Treffers, R., Zandstra, D. F., & Stoutenbeek, C. P. (1994) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/1053-0770(94)90414-6
Jarrin, D. C. (2012) · Spectrum Research Repository (Concordia University)
Čabarkapa, V., Đerić, M., & Stošić, Z. (2009) · Journal of Medical Biochemistry · doi:10.2478/v10011-009-0001-3
In-Vivo Assessment of Coronary Atherosclerosis
Rodríguez-Granillo, G. A. (2006) · RePub (Erasmus University Rotterdam) · Cited by 1
Ventricular Rotation and the Rotation Axis A New Concept in Cardiac Function
Gustafsson, U. (2010) · KTH Publication Database DiVA (KTH Royal Institute of Technology)
Loizou, C. P., Anastasiou, E., Kasparis, T., Lazarou, T., Pantziaris, M., & Pattichis, C. S. (2013) · IFIP advances in information and communication technology · doi:10.1007/978-3-642-41142-7_28
Cohendy, R., Périès, C., Lefrant, J., Doucot, P., Saïssi, G., & Eledjam, J. (1996) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1996.tb04568.x
Zhao, S., Cai, C., Zhu, X., Wang, G. L., & Yuan, F. Q. (2011) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2011.6017447
BONE LOSS IN RELATION TO HYPOTHALAMIC ATROPHY IN ALZHEIMER'S DISEASE
Loskutova, N. (2011) · KU ScholarWorks (The University of Kansas)
Andreasen, J., Olesen, C. G., Rasmussen, J., Nielsen, S. K., Nguyen, L., & Larsen, P. F. (2012) · Australian Occupational Therapy Journal · doi:10.1111/j.1440-1630.2012.01024.x
IRM des valvulopathies régurgitantes
Germain, P. (2011) · Springer eBooks · doi:10.1007/978-2-8178-0154-4_14
Nilforushan, N., & Karimi, N. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2014.10.025
Austin, S., McAtamney, D., Maguire, P., Loan, P. B., & Crean, P. M. (2000) · Pediatric Anesthesia · doi:10.1046/j.1460-9592.2000.010006691.x
Laubscher, T. P., Frutiger, A., Fanconi, S., Jutzi, H., & Brunner, J. X. (1995) · Springer eBooks · doi:10.1007/978-3-642-78399-9_45
Early Definition of Treatment Outcomes After Reperfusion Therapy for Myocardial Infarction
Zhang, Y., Patel, A. A., & Jeremy, R. (2004) · Heart Lung and Circulation · doi:10.1016/j.hlc.2004.01.007
Okuno, N. M. (2011) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.39.2011.tde-19092011-150742 · Cited by 1
Comparison of results from two methods of measurement of stride characteristics
Peterson, M. G. E., Murray-Weir, M., & Root, L. (2002) · Proceedings - IEEE Symposium on Computer-Based Medical Systems · doi:10.1109/cbms.1993.262986
Evaluation of an in‐line dialysate urea monitor including assessment of ‘V’
Kerr, P. G., xiong, D., Howard, J., McGEE, O., Strauss, B. J., & Atkins, R. C. (1996) · Nephrology · doi:10.1111/j.1440-1797.1996.tb00087.x
Ong, H. S., Lim, M., & Lh, L. (2002) · Annals of the Academy of Medicine Singapore · doi:10.47102/annals-acadmedsg.v31n2p145
Reverte, P. E. (2012) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 1
Gómez, M. I. L., Sáiz, D. D. F., & Sanchís, V. J. C. (2012) · RUA, Repositorio Institucional de la Universidad de Alicante (Universidad de Alicante)
Zhang, Y., Sun, K., Ye, B., Chen, G., Wu, L., & Zhang, Z. (2009) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2009.5163116
An Automatic Calibration Approach For Left Ventricular Volume Assessment
Perrenot, B., Vaillant, R., Douek, P., Prost, R., Peyrin, F., & Finet, G. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353329
Statistical modelling of body composition in children and their parents
Villoria, M. F. (2009) · Enlighten: Theses (The University of Glasgow) · Cited by 1
Rossi, L. P. (2013) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Kolbach, D. N., Leffers, P., Neumann, H. A. M., Kuiper, J., Partsch, H., & Prins, M. H. (2005) · Phlebology The Journal of Venous Disease · doi:10.1177/026835550502000302 · Cited by 2
A Wireless Interface for Replacing the Cables in Bridge-Sensor Applications
Pavlin, M., & Novak, F. (2012) · Sensors · doi:10.3390/s120810014
Lung Emphysema & Cardiac Function
Jörgensen, K. (2008)
PMC14 EQUIVALENCE OF PAPER AND TOUCH SCREEN VERSIONS OF THE EQ-5D VISUAL ANALOG SCALE (EQ-VAS)
Ramachandran, S. P., Taber, T., Craig, B., & Coons, S. J. (2005) · Value in Health · doi:10.1016/s1098-3015(10)63017-3
Evaluierung des minimalinvasiven FloTrac™/Vigileo™-Monitoringsystems an kritisch kranken Patienten
Zukunft, B. (2008) · Universitätsbibliothek der FU Berlin Hochschulschriftenstelle u. Dokumentenserver · doi:10.17169/refubium-14692
Shih, S.-T., & Chang, K.-Y. (2009)
Cronin, L. (2010) · Arrow@dit (Dublin Institute of Technology) · doi:10.34961/7684 · Cited by 1
Comparison of Ultrasound and Scheimpflug Methods for Central Corneal Thickness
Erşekerci, T. K., Kılıç, R., Çomçalı, S. Ü., Çetin, A. B., & Yasin, M. D. (2015) · Journal of Advances in Medicine and Medical Research · doi:10.9734/bjmmr/2015/17579
Whole body vibration to address motor and sensory impairments in people with multiple sclerosis
Uszynski, M. (2014) · University of Limerick Institutional Repository (University of Limerick) · doi:10.34961/7717
Kunkel, S. A. (2011) · University of Minnesota Digital Conservancy (University of Minnesota) · Cited by 1
Hoffmann-Petersen, N., & Pedersen, E. B. (2015) · The Open Hypertension Journal · doi:10.2174/1876526201507010007
Johns, S. (2012) · ORCA Online Research @Cardiff (Cardiff University)
Renal risk markers and cardiovascular disease
Hillege, J. L. (2002) · University of Groningen research database (University of Groningen / Centre for Information Technology)
Clinical relevance of exercise testing in pulmonary hypertension
Groepenhoff, H. (2013) · Digital Academic REpository of VU University Amsterdam (Vrije Universiteit Amsterdam)
RENAL FUNCTION IN RELATION TO GENTAMICIN AND DABIGATRAN CLEARANCE AND DOSING
Ken, P., & Chin, L. (2014)
Cost Effective Diagnosis and Monitoring of HIV-1 in a Resource Poor Setting
Rekhviashvili, N. (2008) · University of the Witwatersrand, Johannesburg Institutional Repository on DSpace (University of the Witwatersrand, Johannesburg)
Respiratory Morbidity and Exhaled Nitric Oxide in the First 2 Years of Life: the Generation R Study
Gabriele, C. (2009) · EUR Research Repository (Erasmus University Rotterdam)
Vessel segmentation for time resolved phase contrast MRI
Bidhult, S. L. (2013) · Lund University Publications Student Papers (Lund University)
The safety of oxygen‐driven nebulisers
Crone, P. D. (1993) · Emergency Medicine Australasia · doi:10.1111/j.1442-2026.1993.tb00783.x
Leinonen, J. (2006) · Työväentutkimus Vuosikirja
Wild, J. M., Sims, A. J., Pemberton, J., Kenny, A., & Murray, A. (2007) · Computers in cardiology · doi:10.1109/cic.2007.4745424
Quantification of beading intensity in cultured neurons
Dastgheyb, R. M., Gallo, G., & Barbee, K. A. (2011) · IEEE Annual Northeast Bioengineering Conference (NEBEC) · doi:10.1109/nebc.2011.5778566
Chedid, F. D., Imran, A., Durrani, N. U. R., Musharaf, I., Rehman, M., & Datt, G. (2010) · Early Human Development · doi:10.1016/j.earlhumdev.2010.09.046
Kobr, J., & Pizingerová, K. (2014) · Journal of Clinical and Experimental Research in Cardiology · doi:10.15744/2394-6504.1.103
Advanced Cardiovascular Monitoring
de Waal, E. E. C. (2009) · Utrecht University Repository (Utrecht University)
Dawson, H., Sutton‐Harmer, A., Hoff, B. H., & Grift, E. (2000) · Equine Veterinary Education · doi:10.1111/j.2042-3292.2000.tb00071.x
Raczak, G., Pinna, G. D., Figura-Chmielewska, M., Daniłowicz-Szymanowicz, L., Szwoch, M., Kubica, J., & Buda, T. G. I. P. (2002) · Via Medica Journals
Lassout, O., Hochstrasser, D. F., & Lescuyer, P. (2014) · Clinical Proteomics · doi:10.1186/1559-0275-11-38 · Cited by 1
Central Visual Field Assessment in Late Stage Glaucoma
Balian, C. (2006) · UWSpace (University of Waterloo)
Song, W., Yang, X., Wang, J., Yu, Y., & Sun, K. (2011) · Computing in cardiology
Immune response to exercise in patients with COPD.
van Helvoort, H. A. C. (2006) · Radboud Repository (Radboud University)
Development and refinement of a portable electronic device for haematocrit determination
Groenewald, A. J., & Pieters, H. (2008) · South African Journal of Science · doi:10.1590/s0038-23532008000600018
Tomographic ventilation-perfusion lung scintigraphy in cardiopulmonary disease
Jögi, J. (2011) · Lund University Publications (Lund University)
Muris, D. M. J., Gronenschild, E. H. B. M., Schram, M. T., Karaça, Ü., Stehouwer, C. D. A., & Houben, A. J. H. M. (2014) · Microvascular Research · doi:10.1016/j.mvr.2014.04.006
Bimanual movement control : insights from golf ball striking
Tinmark, F. (2014) · Diva portal (Dalarna University Library)
Dynamic Morphology of the Aorta. Pre- and postoperative imaging
van Prehn, J. (2009) · Utrecht University Repository (Utrecht University)
Amount of error in a measurement? …Reliability
McDonough, P. G. (2003) · Fertility and Sterility · doi:10.1016/s0015-0282(03)02176-9
Examining the role of sitting behaviour in non-specific chronic low back pain
O’Sullivan, K. (2012) · Arrow@dit (Dublin Institute of Technology) · Cited by 1
Infarct size and myocardial function : A methodological study
Rosendahl, L. (2010) · KTH Publication Database DiVA (KTH Royal Institute of Technology)
Jarvis, J. N., Bradley, J., Meintjes, G., Harrison, T. S., & Kozel, T. R. (2012) · Clinical Infectious Diseases · doi:10.1093/cid/cis781
Short-term stability of baroreflex sensitivity
Frederiks, J., Swenne, C. A., Maan, A. C., ten Voorde, B. J., & Bruschke, A. V. G. (2002) · Computers in cardiology · doi:10.1109/cic.1998.731804
Beishuizen, E. D. (2008) · Leiden Repository (Leiden University)
Bjerre, A., & Baldwin, L. (2012) · British and Irish Orthoptic Journal · doi:10.22599/bioj.55
Fetal echo doppler for early detection of congenital heart block
Bergman, G. (2010) · Figshare
Nigro, C. A., Dibur, E., Lima, S. Á. M., Giavedoni, S., Prieto, E., & Rhodius, E. E. (2005) · PubMed
Energy expenditure in lean and obese women: the role of posture allocation
Johannsen, D. L. (2006) · Iowa State University Digital Repository (Iowa State University) · doi:10.31274/rtd-180813-220
Cunha, S. I. D. O. A. (2008) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 1
VEGF Levels in Women with Gynaecological Cancers
Lee, J. (2010) · Otago University Research Archive (University of Otago)
Natural history of a coronary plaque followed by computed tomography
Inaba, S., Okayama, H., Kido, T., Mochizuki, T., & Higaki, J. (2012) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ejechocard/jer310
Chen, T.-H., Hsin, C., Ko, W., Liou, C., & Hung, W. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9593-x
Accuracy and reproducibility of an on-line quantitative coronary angiographic system
Desmet, W. J., Willems, J. L., Vrolix, M., Lierde, J. V., Byttebier, G., & Piessens, J. (2003) · Computers in cardiology · doi:10.1109/cic.1992.269532
Role of ambulatory blood pressure monitoring after pediatric renal transplantation
Krmar, R. T. (2008) · Figshare · Cited by 1
Lee, S.-W., Lee, J., Bae, J. H., Jeong, S. Y., Chun, K. A., Ha, J., Ahn, B. C., & Lee, K. B. (2003)
Fetal Growth and Development: The Generation R Study
Verburg, B. O. (2007) · RePub (Erasmus University Rotterdam) · Cited by 1
MRI correlates of vascular cerebral lesions and cognitive impairment
van Straaten, E. C. W. (2008) · Pure Amsterdam UMC · Cited by 3
Monitoring kidney function in diabetic nephropathy
Groth, S., Petersen, C., Dirksen, A., & Parving, H. ‐. (1989) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.1989.tb01406.x · Cited by 1
de Colombia, U. N., Barrera-Castro, S. M., Corredor, F. O., & Roosevelt, I. D. O. I. (2015) · Revista Colombiana de Medicina Física y Rehabilitación · doi:10.28957/rcmfr.v25n1a3
Comparison of Manual and Automated Methods to Measure Position-Induced Ocular Cyclotorsion
Kang, S. Y., Lim, J. W., & Kim, H. M. (2012) · Journal of Clinical & Experimental Ophthalmology · doi:10.4172/2155-9570.1000212
Survey of the TS-ECE Discrepancy and recent investigations in ICRF heated plasmas at Alcator C-Mod
White, A. E., Hubbard, A., Hughes, J. W., Bonoli, P. T., Austin, M. E., Bader, A., Harvey, R. W., Lin, Y., Ma, Y., Reinke, M. L., et al. (2012) · EPJ Web of Conferences · doi:10.1051/epjconf/20123203009
Fiabilidad test-retest de dinamometría manual en personas con secuelas de poliomielitis paralítica
Pérez-Sousa, M. Á., Vicente, M. M., Olivares, P. R., Corzo, H., Parraça, J. A., & Delgado, S. (2012) · Rehabilitación · doi:10.1016/j.rh.2012.05.005
Etude comparative du dosage de l'hémoglobine glyquée par la méthode CLHP sur G8® versus Intégra 800®
Szymanowicz, A., & Neyron, M.-J. (2010) · Annales de biologie clinique · doi:10.1684/abc.2010.0420
Short and long term effects of caesarean section and vaginal delivery
Larsson, C. (2010) · Figshare
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.