STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 43,801–43,900 of 47,868
Yagi, T., Yamamuro, A., Akasaka, T., Yamabe, K., Tamita, K., Katayama, M., Nagai, K., Tani, T., Tanabe, K., Morioka, S., et al. (2003) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(03)00480-2
Westley, I. S., Sallustio, B. C., & Morris, R. G. (2005) · Therapeutic Drug Monitoring · doi:10.1097/00007691-200502000-00016
172. Total energy expenditure in stable patients with cystic fibrosis
McCloskey, M. (1999) · The Netherlands Journal of Medicine · doi:10.1016/s0300-2977(99)90224-3
Hanot, J., Delande, M., & Himpe, D. (2010) · European Journal of Anaesthesiology · doi:10.1097/00003643-201006121-00207
Continuous cardiac output measurements in intensive care patients after cardiac surgery
Mielck, F., Bühre, W., Hanekop, G., Tirilomis, T., & Sonntag, H. (2001) · European Journal of Anaesthesiology · doi:10.1097/00003643-200107001-00074
Effect of Inspiratory Flow on Methacholine Challenge in Children
Chang, A. B., Wilson, S., Masters, I. B., Harrhy, V. A., & Hubbard, M. (2004) · Journal of Asthma · doi:10.1081/jas-120026094
Khamar, M., Danayak, P., & Majumder, C. (2015) · Journal of Clinical Ophthalmology and Research · doi:10.4103/2320-3897.149367
Evaluation of an expired fraction carbon dioxide monitor – incorrect statistical analysis?
Lewis, I. H. (2003) · Anaesthesia · doi:10.1046/j.1365-2044.2003.03207_2.x
Estimación de la fiabilidad en la obtención de información mediante cuestionarios
Gómara, E. R. (2001) · Atención Primaria · doi:10.1016/s0212-6567(01)70489-1
A hand-held quantitative capnometer during air embolism in Göttingen mini-pigs
Maleck, W. H., Jatzko, A., & Petroianu, G. A. (2000) · Resuscitation · doi:10.1016/s0300-9572(00)00169-6
Choroidal Thickness Measurements
Huang, J., Savini, G., Chen, S., Feng, Y., & Wang, Q. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2012.02.026
Cardiac output estimation with transesophageal Doppler
Donati, A., Coltrinari, R., Achilli, D., Adrario, E., Mariani, L., Bechi, P., Pelaia, P., & Pietropaoli, P. (1998) · Critical Care · doi:10.1186/cc207
Yepes, D., Bejarano, J., Panesso, R., & Granados, M. (2007) · Medicina Intensiva · doi:10.1016/s0210-5691(07)74840-4
Ventilation and Haemodynamic Indicators in Spontaneously Breathing Pigs under General Anaesthesia
Kobr, J., Kuntscher, V., Třeška, V., Moláček, J., Vobruba, V., & Fremuth, J. (2010) · Acta Veterinaria Brno · doi:10.2754/avb201079010061
Cardiac Output Monitoring With Brachial Arterial Catheter
Al‐Ruzzeh, S., Modine, T., Athanasiou, T., & Fayad, G. (2006) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2005.07.017
Videobasierte 2D-Gangbildanalyse
Vogt, L., Himmelreich, H., Ruhleder, M., Mahrous, A., & Banzer, W. B. (2003) · Manuelle Medizin · doi:10.1007/s00337-003-0209-0
Bendel, S., Kettunen, R., Hartikainen, J. E. K., Remes, J., Vanninen, E. J., Yang, J., Kuikka, J. T., & Huikuri, H. V. (1999) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050587
Accuracy of OCT in Evaluating Neointimal Thickness After Stent Implantation
Ferrante, G., Dimopoulos, K., Montone, R. A., & Barlis, P. (2010) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2010.04.004
Park, K. S., Min, S. K., Lee, S. Y., Kim, J. S., Kim, J. Y., Park, S. Y., & Son, Y. P. (2008) · Korean Journal of Anesthesiology · doi:10.4097/kjae.2008.54.5.493
Comparison of Two Diverse Measurement Methods by Graphical Agreement
Stošović, M., Rašković, S., & Marinković, J. (2012) · Renal Failure · doi:10.3109/0886022x.2012.715609
Doppler estimates of cardiac output
Rennie, J. M., & Barnes, R. J. (1990) · The Journal of Pediatrics · doi:10.1016/s0022-3476(05)82465-5
Assessment of Gastric pH in the Critically III
Neill, K. M., Ahern, H. L., & Rice, K. T. (1995) · Worldviews on Evidence-based Nursing presents the archives of Online Journal of Knowledge Synthesis for Nursing · doi:10.1111/j.1524-475x.1995.00050.x
Hand-Carried Echocardiography in Assessing Ventricular Function and Valvular Regurgitation
Umekawa, S., Yamamoto, K., Koezuka, A., Nakao, S., Yuba, M., Sakata, Y., Ozaki, T., & Masuyama, T. (2004) · Journal of Echocardiography · doi:10.2303/jecho.2.49
Is the 6-minute cycle test useful in a cardiac rehabilitation programme?
Villumsen, P., Lelieveld, D. W. V., & Möller, S. (2013) · European Journal of Physiotherapy · doi:10.3109/21679169.2013.860622
Long, A., Rouet, L., Vitry, F., Albertini, J. N., Marcus, C. D., & Clément, C. (2009) · Anales de Cirugía Vascular · doi:10.1016/j.acvsp.2008.08.008
Consumo de oxigênio de pico em idosas: comparação entre valores medidos e previstos
Lima, R. M., Bottaro, M., Rauber, S. B., Moreira, S. R., Carregaro, R. L., Barros, J. D. F., & Oliveira, R. J. (2013) · Motriz Revista de Educação Física · doi:10.1590/s1980-65742013000200010
Should the pupil be used as a fixed reference for instrument alignment?
Schachar, R. A. (2005) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2005.12.009
Evaluation of an Abbreviated Protocol for Cytomegalovirus pp65 Antigenemia Testing
LaSala, P. R., Yarsa, J., Nguyen, D. V., Han, X. Y., & Tarrand, J. J. (2009) · American Journal of Clinical Pathology · doi:10.1309/ajcp5c0trrwynjxw
Frequency doubling technology and Octopus visual field
Iester, M., Mennoud, A., & Schnyder, C. C. (2000) · Acta Ophthalmologica Scandinavica · doi:10.1111/j.1600-0420.2000.tb01084.x
Dhamija, S., Hill, A., Cairnduff, V., Bronte, J., McKillop, A. M., Sinclair, M., Patterson, C., & McCance, D. R. (2010) · Proceedings of The Nutrition Society · doi:10.1017/s0029665110002168
Traduction en Arabe et validation du questionnaire LFES – SQ
Yahia, A., Sellami, M., Guermazi, M., Ghroubi, S., Elleuch, M. H., André, E., Schmitt, C., TAIEB, C., Baklouti, S., & Elleuch, M. H. (2010) · Journal de Réadaptation Médicale Pratique et Formation en Médecine Physique et de Réadaptation · doi:10.1016/j.jrm.2010.03.008
VESSEL DIAMETER TRACKING IN INTRAVITAL MICROSCOPY IMAGE SEQUENCES
Lee, J., Jirapatnakul, A. C., Reeves, A. P., Crowe, W. E., & Sarelius, I. H. (2007) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2007.356863
Hoste, L., & Pottel, H. (2015) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2014.1003250
Sanders, A. P. (1995) · RePub (Erasmus University Rotterdam)
Maram, J., Sorbara, L., & SIMPSON, T. L. (2012) · Optometry Reports · doi:10.4081/optometry.2012.e4
In vitro validation of the luminal measurement of a novel catheter based moulding technique
Eccleshall, S., Jordan, P. J., Buller, N. P., & Townend, J. (1999) · Heart · doi:10.1136/hrt.81.2.206
Mitral annulus motion in left ventricular pumping
Emilsson, K. (2001)
Hammarén, E. (2014) · Gothenburg University Publications Electronic Archive (Gothenburg University)
Population-Based Studies of Bullying in Young Children
Verlinden-Bondaruk, M. (2014) · EUR Research Repository (Erasmus University Rotterdam)
Clinical Studies in Scanning Laser Polarimetry
Colen, T. P. (2003) · RePub (Erasmus University Rotterdam)
Cognitive-motor interventions: A novel approach to improve physical functioning in older adults
Pichierri, G. (2014) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-a-010104076
Cardiac function in primary and secondary hyperparathyroidism
Näppi, S. E. (2001) · Tampere University Institutional Repository (Tampere University)
Evaluation of Myocardial Function in Chronic Kidney Disease A Colour Tissue Velocity Imaging Study
Hayashi, S. Y. (2008) · DiVA (Digitala Vetenskapliga Arkivet)
Mechanisms involved in malabsorption of dietary lipids
Kalivianakis, M. (1998) · University of Groningen research database (University of Groningen / Centre for Information Technology) · Cited by 1
Klar, N. S. (2005) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400500266718
Measures of agreement for vectorcardiography data
Wang, H. (2009) · Statistics in Medicine · doi:10.1002/sim.3519
Jumilla, M. C. B. (2013) · Digital Repository (Polytechnic University of Cartagena) · doi:10.31428/10317/4040 · Cited by 1
Hilmersson, M. (2014) · Journal of Novel Physiotherapies · doi:10.4172/2165-7025.1000195
The prediction of maximal oxygen uptake from a perceptually-regulated exercise test (PRET)
Morris, M. (2024) · ChesterRep (University of Chester) · doi:10.17638/03181629 · Cited by 1
Automatic detection of the end of the Empting Maneuvers in venous muscle pump test
Sánchez-Gendriz, I., Hernández-Seoane, D., Posada-Quintero, H. F., & Sóñora-Mengana, A. (2012) · Symposium on Image, Signal Processing and Artificial Vision (STSIVA) · doi:10.1109/stsiva.2012.6340552
Eriksson, M. J., Rosfors, S., & Brodin, L. (1999) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(99)70085-4
Braga, M. M. (2008) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.23.2008.tde-20012009-151623
Wang, K., Sims, A. J., & Murray, A. (2009) · Computers in Cardiology Conference · doi:10.25405/ncl.34119162
Analytical performance evaluation of haematological equipment Medonic CA 530 Thor
Chávez-Almazán, L. A., López-Silva, S., Barlandas-Rendón, E., & Armenta-Solís, A. (2009) · Redalyc (Universidad Autónoma del Estado de México)
Non-invasive hemodynamic measurements early in pregnancy
Rang, S. (2008) · UvA-DARE (University of Amsterdam)
Functional residual capacity Development of new monitoring techniques for critically ill patients
Olegård, C. (2010) · Gothenburg University Publications Electronic Archive (Gothenburg University) · Cited by 1
Assessing reproducibility: agreement vs correlation
Herranz, A. (1994) · European Respiratory Journal · doi:10.1183/09031936.94.07101910
Park, S. Y., Kim, D. H., Joe, H. B., Yoo, J. Y., Kim, J. S., Kang, M. S., & Hong, Y. W. (2012) · Korean Journal of Anesthesiology · doi:10.4097/kjae.2012.62.5.423
Frequency doubling perimetry using a liquid crystal display
Spry, P. G. D., Gibbs, M. L., Johnson, C. A., & Howard, D. L. (2001) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(00)00803-5
Aguirregomoscorta, J. I., Altube, L., Menéndez, I., Romaní, A., Basualdo, L. V., & Vallejo, G. (2005) · Archivos de Bronconeumología · doi:10.1016/s1579-2129(06)60331-5
McCarthy, W. F., & Guo, N. (2007) · Collection of Biostatistics Research Archive
Beyer, K. B. (2010) · University Library - University of Saskatchewan (University of Saskatchewan)
Estimation of body composition from total body potassium [40K] counts among college women
Saleh, Z. A., Razek, F. H. A., & Hussein, L. (2003) · Nutrition Research · doi:10.1016/s0271-5317(02)00471-2
Fritsche‐Polanz, R., Huber, A., Wolfgang Hagen, M., Feix, A., Hauser, A.-C., Sunder–Plassmann, G., Bieglmayer, C., & Födinger, M. (2003) · Laboratory Medicine · doi:10.1309/9chq-l715-dc8v-dqar
Vitamin D receptor genotype BB is associated with higher serum osteocalcin in first pregnancy
Feuz, J., Wisser, J., Heufelder, A. E., Joba, W., Zimmermann, R., & von Mandach, U. (2009) · Journal of Perinatal Medicine · doi:10.1515/jpm.2009.091
Jordanoglou, J. B., Latsi, P. I., Chroneou, A., & Koulouris, N. G. (2007) · Acta Physiologica · doi:10.1111/j.1748-1716.2007.01742.x
POST-POLIO SYNDROME - PHYSIOTHERAPEUTIC ANALYSIS AND INTERVENTIONS
Vreede, K. S. (2013) · Figshare · Cited by 1
Establishment of cheap and reliable real-time PCR for quantitation of HIV-1 viral load in plasma.
Supadej, K., & Intorasoot, S. (2012) · PubMed
Quality on-line monitoring of active compression decompression cardiopulmonary resuscitation
Gilly, H., Baubin, M., & Haid, C. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2000.901505
Niveles ambientales de aeroalergeno de soja en la ciudad de Barcelona
Carmona, C., & Cruz, M. J. (2005) · Tesis Doctorals en Xarxa (Consorci de Serveis Universitaris de Catalunya)
Zhao, S. (2012) · International Journal of the Physical Sciences · doi:10.5897/ijps11.1523
Hinkelbein, J., Osika, A., Genzwürker, H. V., & Fiedler, F. (2005) · Intensivmedizin und Notfallmedizin · doi:10.1007/s00390-005-0628-3 · Cited by 1
Accuracy of physical self-description among chronic exercisers and non-exercisers
Berning, J. M., DeBeliso, M., Sevene, T. G., Adams, K. J., Salmon, P. M., & STAMFORD, B. A. (2014) · Health Psychology Research · doi:10.4081/hpr.2014.1746
High speed perfusion image based on laser speckle fluctuations
Draijer, M. J. (2009) · doi:10.3990/1.9789036529792
Bonnyman, A. M. (2011) · MacSphere (McMaster University) · doi:10.71548/9377
Zhao, X., Arsenault, A., Lavoie, K., Meloche, B., & Bacon, S. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352368
Wild, J. M., Sims, A. J., Fleming, S. M., Kenny, A., & Murray, A. (2005) · Computers in cardiology · doi:10.1109/cic.2005.1588128
Kinoshita, T., Kawayama, T., Imamura, Y., Sakazaki, Y., Hirai, R., Ishii, H., Suetomo, M., Matsunaga, K., Azuma, K., Fujimoto, K., et al. (2015) · European Journal of Radiology · doi:10.1016/j.ejrad.2014.12.021
Evaluación de la troponina I en el analizador Pathfast®
Gerique, J. A. G., Izquierdo, F., Galán, A., Laporta, P., Garnacho, N., & Ekizoglou, N. (2009) · Revista del Laboratorio Clínico · doi:10.1016/j.labcli.2009.05.001
Held, M. F. G., Roche, S., Vrettos, B. C., Laubscher, M., & Walters, J. (2012) · Shoulder & Elbow · doi:10.1111/j.1758-5740.2012.00189.x
Validación de monitores de medida de presión arterial
Mas, J. R. I. (2003) · Hipertensión y Riesgo Vascular · doi:10.1016/s1889-1837(03)71336-1
Desenvolvimento de um Sistema de Verificação da Pressão Arterial Através do Método Oscilométrico
Pereira, L. F. (2006) · Americanae (AECID Library)
Orallo, M. A. G., Aguirre, P. C., Pereira, D., & Diz, J. C. (2012) · Revista Española de Anestesiología y Reanimación · doi:10.1016/j.redar.2012.02.009
MEDIAN NERVE BIAS TENSION TEST RESPONSES IN NORMAL SUBJECTS
Fortune, J. S. (2000) · University of the Witwatersrand, Johannesburg Institutional Repository on DSpace (University of the Witwatersrand, Johannesburg)
Diameter of the Infrarenal Abdominal Aorta in Children with Cerebral Palsy
Okutan, H., Savaş, S., Baykal, B., Savaş, Ç., Büyükyavuz, İ., & Gülsoy, U. K. (2005) · Annals of Vascular Surgery · doi:10.1007/s10016-005-0007-3
Cytological scoring system in primary breast cancer
Robinson, I. A., McKee, G., de Graaf, H., Willemse, P. H. B., & Sluiter, W. J. (1995) · Cytopathology · doi:10.1111/j.1365-2303.1995.tb00462.x
Inter-examiner agreement of the AS-OCT Visante corneal thickness
Cristóbal, A. D. R. S., Martín, R., Morejona, A., & Galarreta, D. (2011) · Journal of Optometry · doi:10.1016/s1888-4296(11)70048-6
Knešaurek, K., & Macháč, J. (2012) · Journal of Biomedical Graphics and Computing · doi:10.5430/jbgc.v2n1p39
Willcocks, R. J., Fulford, J., BARKER, A. R., Armstrong, N., & Williams, C. A. (2014) · Pediatric Exercise Science · doi:10.1123/pes.2013-0043
Dynamic contrast-enhanced (DCE) imaging for tumor delineation in prostate cancer
Korporaal, J. (2011) · Utrecht University Repository (Utrecht University)
Al-Ekrish, A. A., & Ekram, M. (2011) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/73953311
Testosterone, 17β-estradiol and pubertal growth
Albin, A. (2014) · Gothenburg University Publications Electronic Archive (Gothenburg University)
Correlación de los valores de pCO2 obtenidos por gasometría arterial y capnografía transcutánea
Martín, M. A. M., & Ortega, C. (2013) · Sanidad militar: revista de sanidad de las Fuerzas Armadas de España · doi:10.4321/s1887-85712013000200004
Cantero, J. M. B., García, J. J., Cuesta, P. R., Galilea, Á. G., García-Borruel, M. M., Sánchez, V. G., & Calderón, C. G. (2012) · Medicina Clínica · doi:10.1016/j.medcli.2012.07.018
Assessment of Technical Competence for Central Venous Catheterization
Ma, I. W. Y. (2014) · Libraries and Cultural Resources (University of Calgary) · doi:10.5072/prism/25030
Discharge Policy and Reperfusion Therapy in Acute Myocardial Infarction
van der Vlugt, M. J. (2007) · EUR Research Repository (Erasmus University Rotterdam)
The accuracy of the EASI-derived spatial QRS-T angle
Guldenring, D., Finlay, D., Bond, R., Kennedy, A., & McLaughlin, J. A. (2014) · Computing in cardiology
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.