STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 45,301–45,400 of 47,868
Colbert, S. (1998) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03012320
Neural network technology to predict intracellular water volume
Chiu, J.-S., Chen, C.-A., Lee, C., Li, Y., LIN, Y.-F., Yf, W., & Yu, F.-C. (2006) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2006.00761.x
Castro, A., Carvalho, P., Muehlsteff, J., Mattos, S. D. S., & Coimbra, M. T. (2017) · IGI Global eBooks · doi:10.4018/978-1-5225-3158-6.ch045 · Cited by 2
Agin, M. A. (2008) · Wiley eBooks · doi:10.1002/9780471462422.eoct326
RELIABILITY OF A COMPUTERIZED TARGET-PURSUIT SYSTEM FOR MEASURING COORDINATED EXERTION OF FORCE
Nagasawa, Y. (2003) · Perceptual and Motor Skills · doi:10.2466/pms.96.3.1071-1085
Smith, F. G., & Smith, J. E. (2002) · CRC Press eBooks · doi:10.3109/9780203450307-17
Sowula, P. (2021) · Queensland University of Technology · doi:10.5204/thesis.eprints.208082 · Cited by 1
On the Practical Consequences of Misfit in Mokken ScalingPreprint
Crișan, D. R., Tendeiro, J. N., & Meijer, R. R. (2019) · doi:10.31234/osf.io/kgc3a
Anaesthesia Journal of the Association of Anaesthetists of Great Britain and Ireland
categories:, P. N. T. T. O. A. R. F. C. R. I. A. 3. C. R. C. B. D. I. F. B. (2002) · Anaesthesia · doi:10.1046/j.0003-2409.2002.02745_57_7.x
Oxford Shoulder Instability Score
Dawson, J. (2014) · Springer eBooks · doi:10.1007/978-94-007-0753-5_2047
Experimental Conditions and Processing
(2012) · Royal Society of Chemistry eBooks · doi:10.1039/9781849735339-00096
Choudhary, P. K. (2014) · Wiley eBooks · doi:10.1002/9781118445112.stat00184
One-year test-retest reliability of ten vision tests in Canadian athletes
Aloosh, M., Leclerc, S., Long, S., Zhong, G., Brophy, J. M., Schuster, T., Steele, R. J., & Shrier, I. (2020) · F1000Research · doi:10.12688/f1000research.19587.3
Lord, P. F., Hansson, K., Carnabuci, C., Kvart, C., & Häggström, J. U. (2012) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2012.00880.x
Banerjee, D., Hofman, D. E., & Melhuish, J. (1998) · Journal of Wound Care · doi:10.12968/jowc.1998.7.3.155
Rousson, V., & Gasser, T. (2010) · Informa Healthcare eBooks · doi:10.3109/9781439822463.182
Lehmann, O. J., McLeod, D., Dowling, C., & Carroll, R. N. (1993) · BMJ · doi:10.1136/bmj.306.6882.928-a
Estimating Body Fat in Lean and Obese Women
(2009) · Nutrition Reviews · doi:10.1111/j.1753-4887.1992.tb01274.x · Cited by 1
Feuer, W. J., Gregori, N. Z., Shi, W., Schiffman, J., Phung, L., & Ortiz, A. G. (2016) · Retina · doi:10.1097/iae.0000000000001297
O’Malley, G. F. (2007) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.11.028
A NOVEL PROTAMINE SENSOR FOR MEASUREMENT OF HEPARIN LEVELS IN BLOOD AND PLASMA
Baliga, N., Ramamurthy, N., Meyerhoff, M. E., Yang, V. C.-M., & Wahr, J. (1998) · Anesthesia & Analgesia · doi:10.1213/00000539-199804001-00026
Gray, W., Palmer, J. D., Gill, M. J., & Iannotti, F. (1997) · Neurosurgery · doi:10.1097/00006123-199711000-00051
Liao, J. J. Z., & Capen, R. C. (2014) · Wiley eBooks · doi:10.1002/9781118596333.ch26
Verhagen, A. P., & Alessie, J. (2018) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-368-2123-0_2
Choudhary, P. K. (2010) · Wiley eBooks · doi:10.1002/0471667196.ess7127
(1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.2.erratum2
Schurink, G. W. H., & van Bockel, J. H. (2001) · Journal of Vascular Surgery · doi:10.1067/mva.2001.111749
Frame Size, Circumferences, and Skinfolds
Scott, B. (2007) · CRC Press eBooks · doi:10.1201/9781420008890.ch34
Exploration de la fonction glomérulaire rénale (II). Estimation du débit de filtration glomérulaire
Maillard, N., Delanaye, P., & Mariat, C. (2011) · Encyclopédie médico-chirurgicale. Néphrologie · doi:10.1016/s1762-0945(11)58065-9
Scientific Proceedings of the Victor Bonney Society Meeting, Chepstow, Gwent, 12-14 April 1991
(1991) · Journal of Obstetrics and Gynaecology · doi:10.3109/01443619109027831
Kendrick, A. (1989) · Respiratory Medicine · doi:10.1016/s0954-6111(89)80237-9
Verhagen, A. P., & Alessie, J. (2014) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-368-0821-7_2
Moore, C., & Weerakkody, Y. (2020) · Radiopaedia.org · doi:10.53347/rid-74312
(1996) · Proceedings of The Nutrition Society · doi:10.1079/pns19960095
Agin, M. A. (2014) · Wiley eBooks · doi:10.1002/9781118445112.stat07123
Perrotta, A. S., Jeklin, A. T., Hives, B. A., Meanwell, L. E., & Warburton, D. E. R. (2017) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002156
Piacentini, E. A., Wysocki, M., & Blanch, L. L. (2012) · Springer eBooks · doi:10.1007/978-3-642-28270-6_33
(1994) · Proceedings of The Nutrition Society · doi:10.1079/pns19940075
Kobayashi, R. (1998) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03012321
Rodríguez, A. S. (2020) · Revista Digital Internacional de Psicología y Ciencia Social · doi:10.22402/j.rdipycs.unam.6.1.2020.281.1-246 · Cited by 1
Peters, T. J. (2014) · Wiley eBooks · doi:10.1002/9781118445112.stat05568
(1998) · Proceedings of The Nutrition Society · doi:10.1079/pns19980070
Schwenke, C. (2014) · Wiley eBooks · doi:10.1002/9781118596005.ch28
Elliott, D. B. (1992) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.1992.tb00265.x
Galstyan, G. M., Bychinin, M., Alexanyan, M., & Gorodetsky, V. (2012) · Springer eBooks · doi:10.1007/978-3-642-28270-6_44
Hamilton, D. (2004) · Springer eBooks · doi:10.1007/978-3-662-06588-4_26
Heys, S. D., Park, K. G. M., Dunn, M., Unit, N., Keenan, R. A., Miller, J. D. B., Broom, J., Eremin, O., & Garlick, P. J. (1990) · Proceedings of The Nutrition Society · doi:10.1079/pns19900038
(2002) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456320203900620
Royal academy of medicine in Ireland section of biomedical sciences
(1999) · Irish Journal of Medical Science (1971 -) · doi:10.1007/bf02946485
Liao, J. J. Z., & Capen, R. C. (2014) · Wiley eBooks · doi:10.1002/9781118445112.stat07111
Schwenke, C. (2005) · Wiley eBooks · doi:10.1002/0471667196.ess7255
Yamaguchi, T., Koide, Y., Yotsukura, M., Yoshino, H., & Ishikawa, K. (2000) · 杏林医学会雑誌 · doi:10.11434/kyorinmed.31.145
Karabela, Y., & Bülent, A. Y. A. N. (2022) · Online Türk Sağlık Bilimleri Dergisi · doi:10.26453/otjhs.1057079
Accuracy of Ultrasound Jugular Venous Pressure Height in Predicting Central Venous Congestion
Saleh, A. S. (2022) · Annals of Internal Medicine · doi:10.7326/l22-0117
Navarro-Padilla, M. L., Bernal-Orozco, M. F., Fernandez-Ballart, J. D., Vizmanos-Lamotte, B., Rodríguez-Rocha, N. P., & Ojeda, G. M. (2022) · Nutrients · doi:10.3390/nu14112313
Considerations for Generic-to-Generic Levothyroxine Switching
Funck‐Brentano, C. (2022) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2022.1987
Vargas, M. D. L. Á. (2022) · Depósito Académico Digital Universidad de Navarra (University of Navarra) · doi:10.15581/10171/63680
Kharroubi, S. A., & Kelleher, D. P. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2022.917728
Reliability of a Medicine Ball Explosive Power Test in Young Volleyball Players
Khemiri, A., Teboulbi, A., Gritli, A., Hachana, Y., & Attia, A. (2022) · Ukraïnsʹkij žurnal medicini bìologìï ta sportu · doi:10.26693/jmbs07.03.282
La intensidad de la actividad física y su papel en la prevención cardiovascular en la cohorte SUN
Hidalgo-Santamaría, M. (. (2022) · Depósito Académico Digital Universidad de Navarra (University of Navarra) · doi:10.15581/10171/63776
Development and Validation of Novel Digital Retinoscopy to Analyze Total Refraction of the EyePreprint
Zou, H., Shi, S., Yang, X., Ma, J., Chen, X., Wang, Y., Zhang, M., Song, J., Jiang, Y., Li, L., et al. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4098702
A validated new classification for intervertebral disk degeneration
Stepanov, I. A., Белобородов, В. А., & Сороковиков, В. А. (2022) · Pirogov Russian Journal of Surgery · doi:10.17116/hirurgia202206172
Accuracy of Resting Metabolic Rate EquationsPreprint
Bakır, B. O., & Cebioğlu, İ. K. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4134466
Statistics and Intelligence: A Chequered Relationship
Weiß, C. (2022) · Springer eBooks · doi:10.1007/978-3-031-04198-3_13 · Cited by 1
“Tehlikeli Bölge” Gerçekten Tehlikeli mi?– Endodonik Bakış Açısı
Yanık, D., & Özel, Ş. (2022) · Balıkesır Health Sciences Journal · doi:10.53424/balikesirsbd.1107580
Gunter, S. A., Gadberry, S., Coffey, K., & Moffet, C. A. (2022) · Animal Production Science · doi:10.1071/an21311
Seyfang, M., Dreyhaupt, J., Wiegreffe, C., Rudolph, H., Luthardt, R. G., & Kuhn, K. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105861
Creation of a tool to evaluate supportive care
Giacchero, D., Buiret, G., Bartolini-Grosjean, C., TAIEB, C., Saghatchian, M., & Krakowski, I. (2022) · Palliative & Supportive Care · doi:10.1017/s1478951522000918
Deviandri, R., Yuliana, V., & Kautsar, A. P. (2022) · Malaysian Orthopaedic Journal · doi:10.5704/moj.2207.003
Validation of cough peak flow assessment using a spirometer in healthy young adults
Egoshi, S., TAKEHARA, R., NOJIMA, H., MIURA, T., & Horie, J. (2022) · Japanese Journal of Health Promotion and Physical Therapy · doi:10.9759/hppt.12.25
Alan, C. D. S. Z., Lima, A. A. P., Bakker, J., & Friedman, G. (2022) · Revista Brasileira de Terapia Intensiva · doi:10.5935/0103-507x.20220023-pt
von Gersdorff, G. J. E., Kulig, B., Mellmann, J., & Sturm, B. (2022) · International Drying Symposium (IDS) · doi:10.55900/zlkwkexe
Foot tracking can be an alternative to determine foot strike and take-off during vertical jumps
Filho, E. G. D. C., Moura, F. A., & Bini, R. R. (2022) · Sports Biomechanics · doi:10.1080/14763141.2022.2109504
Agreement between mechanical and digital skinfold callipers
Faria, A., Martinho, D. V., Abreu, B., Franco, B. R. C., Carrilho, L. A. M., Azaruja, M. C., Mendes, P., Serra, M. D. S., Lemos, J. A. T., & Figueiredo, J. P. (2022) · Nutrition and Health · doi:10.1177/02601060221119247
Singh, P., Esposito, M. J. S., Barrons, Z. B., Clermont, C. A., Wannop, J. W., & Stefanyshyn, D. J. (2022) · Sports Engineering · doi:10.1007/s12283-022-00383-4
Nussbaum, L., & Seidl, D. (2016) · INFM-OAR (INFN Catania) · doi:10.5281/zenodo.161580
Barbosa, J. M. M., Santos, T. R. T., Santos, L. A. D. O., Cintra, T. M., Faccio, R. B. D. Á., & Pereira, L. S. M. (2022) · Geriatrics Gerontology and Aging · doi:10.53886/gga.e0220023
Liu, H., Aslan, M., Sandoval, V., & Liu, Y.-H. (2022) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-022-00747-y
Filer, J. L., Fleming, T. R., Morris, S., Upadhyay, N., Landham, P. R., Katsimihas, M., & Harding, I. (2022) · European Spine Journal · doi:10.1007/s00586-022-07382-w
Which Histometric Analysis Approach Is More Reliable for Assessing Histological Bone Tissue Samples?
Pereira, R. D. S., Mourão, C. F., Piattelli, A., Romanos, G. E., Mendes, B. C., Giubilato, F., Montemezzi, P., Conforte, J. J., Griza, G. L., Bonardi, J. P., et al. (2022) · Medicina · doi:10.3390/medicina58101364
Lee, J., Lee, H., Ha, S. Y., Kim, H. C., Kang, Y., Jin, S., & Park, S.-H. (2022) · Journal of Neuroimaging · doi:10.1111/jon.13047
The NEDOCS tool to measure crowding at an academic Emergency DepartmentPreprint
van Westerop, L., van Eeten, E., Bruinen, A. R. C., Eikendal, T., van der Linden, C., & Tan, E. C. T. H. (2022) · Research Square · doi:10.21203/rs.3.rs-1774573/v1
Remote measurement of the clinical prescription of spectacle lenses
Guan, Y., Miller, J. M., Harvey, E. M., Ashley, S., & Schwiegerling, J. T. (2022) · Novel Optical Systems, Methods, and Applications · doi:10.1117/12.2632546
Milano, G. (2013) · PubMed Central
Amici, G. (1996) · The International Journal of Artificial Organs · doi:10.1177/039139889601900404
Recent Developments and Applications in Tissue Mechanics and Tissue Engineering
Boschetti, F. (2022) · MDPI eBooks · doi:10.3390/books978-3-0365-5318-4
Kooshiar, H., MacDermid, J. C., Walton, D. M., & Grewal, R. S. (2022) · Quality in Ageing and Older Adults · doi:10.1108/qaoa-03-2022-0020
Tutchenko, L., Patel, S., Skovron, M., Horak, O., & Voytsekhivskyy, O. (2022) · Journal of Ophthalmology · doi:10.1155/2022/6775064
A basic study for assessment of lower extremity venous function using air plethysmography
Hida, K., 黒瀬, 公., Shiozawa, H., Kobata, T., 原田, 良., Kobayashi, M., Shikata, H., Sakamoto, S., & Matsubara, J. (2002) · The Japanese Journal of Phlebology · doi:10.7134/phlebol.13-2-71
Abstracts of Original Communications (University of Leeds, Leeds, UK. 2–5 July 2002)
(2002) · Proceedings of The Nutrition Society · doi:10.1017/s0029665102000277
Blood glucose measurement in neonatal intensive care
Reynolds, G. (1997) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/fn.77.2.f157
Lai, P. S., Wong, Y.-L., Noor, M. H. M., & Ibrahim, M. A. (2022) · Research Square · doi:10.21203/rs.3.rs-1651221/v1
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.