STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 44,801–44,900 of 47,868
Saha, B. B., Thu, K., & Wijayanta, A. T. (2018) · Evergreen · doi:10.5109/1957499
Leite, M. R., Ramos, E. M. C., Kalva‐Filho, C. A., Silva, B. S. D. A., Freire, A. P. C. F., Campos, E. Z., & Ramos, D. (2019) · Physiotherapy Theory and Practice · doi:10.1080/09593985.2019.1579282
Molaee, P. (2012) · Adelaide Research & Scholarship (AR&S) (University of Adelaide)
Comparação da frequência cardíaca máxima entre teste máximo na natação e equações de predição
Lahr, S. L. N., Silva, R. G., Bernardina, G. R. D., Teixeira, R. B., & Marins, J. C. B. (2019) · Revista Brasileira de Ciências do Esporte · doi:10.1016/j.rbce.2018.11.003
Screening strategies for dysglycaemia in relation to cardiovascular risk
Shahim, B. (2019) · Figshare · Cited by 1
Paratriathletes' physiological and thermoregulatory response to training load and competition
Stephenson, B. T. (2019) · Loughborough University Institutional Repository (Loughborough University) · doi:10.13140/rg.2.2.11842.73929
高齢者での棘上筋腱,肩峰下滑液包と上腕二頭筋長頭腱の肥厚変化─超音波検査を用いて─
大矢, 暢., & 拓実, 山. (2018) · Institutional Repositories DataBase (IRDB) · doi:10.24531/jhsaiih.21.2_74
Kimble, A. (2019) · PEARL (University of Plymouth) · doi:10.24382/857
Maetzler, M., Bochdansky, T., & Abboud, R. (2019) · The Foot · doi:10.1016/j.foot.2019.03.001
Exploring outcome measures for adults with myotonic dystrophy type 1
Moreno, J., & Cecilia, A. (2017) · Cited by 1
RELIABILITY OF CERVICAL EXTENSION AND ROTATION ISOMETRIC STRENGTH TESTING IN SYMPTOMATIC SUBJECTS
Lemire, J. (1999) · HARVEST (University of Saskatchewan)
Using a numerical method to precisely evaluate the alpha angle in a hip image
Lai, C.-L., Chi, W.-M., Ho, Y., Lin, C.-C., Lin, H.-C., Kuo, C.-L., & Chen, J.-H. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-01973-4
Hardy, J., Collin, C., Mathieu, P.-A., Vergnenègre, G., Charissoux, J.-L., & Marcheix, P.-S. (2019) · Revue de Chirurgie Orthopédique et Traumatologique · doi:10.1016/j.rcot.2019.02.005
Estimating the effective arterial elastance at bedside: a reply to a rebuttal
Chemla, D., Teboul, J., & Jozwiak, M. (2019) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00303-1
ESTIMATION OF MEAN CENTRAL CORNEAL THICKNESS USING SIRIUS SCHEIMPFLUG–PLACIDO TOPOGRAPHER IN BASRAH
Fadil, A. M., & Al-Asadi, S. Z. (2017) · Basrah Journal of Surgery · doi:10.33762/bsurg.2017.132414
Choi, P., Webster, R. O., & Agiovlasitis, S. (2019) · Human Movement · doi:10.5114/hm.2019.81022 · Cited by 1
Izod, A. (2019) · UEL Research Repository (University of East London) · doi:10.15123/pub.8097 · Cited by 1
A Biomechanical Investigation into Force, Power and Bone Morphology
Owen, N. J. (2018) · Cronfa (Swansea University) · doi:10.23889/suthesis.49070
Acar, E., Hunç, F., Kum, T., Eraldemir, F. C., Kır, H. M., & Baydemır, C. (2019) · Revista română de medicină de laborator · doi:10.2478/rrlm-2019-0006
Comparison of Time-Domain and Frequency-Domain Contact Resonant Ultrasound Spectroscopy
Hernández-Becerra, P. A. I., Balleza, M., Vargas-Luna, M., & Delgadillo‐Holtfort, I. (2019) · Instruments and Experimental Techniques · doi:10.1134/s0020441219020118
Hay Acuerdo Entre Radiólogos Con La Escala ASPECTS Para Informar El Ictus
Bártulos, A. V., García, D. L., Rosas, J. A. A., Royuela, A., Farrás, M. N. P., & Sánchez, J. (2018) · Seram
Area Triangulation Method for Automatic Detection of Venous Emptying Maneuvers
Sánchez-Gendriz, I., Hernández-Seoane, D., Sóñora-Mengana, A., & Pascau-Simón, A. (2019) · Brazilian Archives of Biology and Technology · doi:10.1590/1678-4324-2019180078
The Measurement and Prediction of Physical Functioning after Trauma
de Graaf, M. W. (2019) · University of Groningen research database (University of Groningen / Centre for Information Technology)
Brouwer, S., & Reinsma, G. D. (2006) · Stimulus · doi:10.1007/bf03063043
A new method for determining active fibrinogen using thromboelastography
Galstyan, G. M., Polevodova, O. A., Берковский, А. Л., Sergeeva, E. V., & Vg, S. (2018) · Russian Journal of Anesthesiology and Reanimatology · doi:10.17116/anaesthesiology201803186
Basal Insulin Adjustments and Continuous Glucose Monitoring During Exercise in Type 1 Diabetes
Zaharieva, D. P. (2018) · YorkSpace (York University)
Specht, J. L., & Todd, N. W. (2019) · The Anatomical Record · doi:10.1002/ar.24178
Owen, H. C. (2019) · The University of Queensland · doi:10.14264/uql.2019.382
Bayesian Estimation of Agreement of Biomarkers in Early Drug Development
Feng, D., Baumgartner, R., & Svetnik, V. (2019) · Statistics in Biopharmaceutical Research · doi:10.1080/19466315.2018.1537887
O’Dell, S. M. (2018) · University of Minnesota Digital Conservancy (University of Minnesota)
Dietary intake data quality in the clinical research setting: Implications of quality improvement
Guan, V. X. (2019) · Research Online (University of Wollongong) · Cited by 1
Teigen, L. M. (2018) · University of Minnesota Digital Conservancy (University of Minnesota)
A neuromuscular and kinematic description of human adults with achondroplasia
Sims, D. T. (2026) · e-space (Manchester Metropolitan University) · doi:10.83056/mmu.32479461
Joplin, D., Benchoff, E., Woodlee, C., Schaal, N., Stubner, A., & Olsen, C. H. (2019) · doi:10.7490/f1000research.1116491.1
Employees’ choice of health benefits and its effect on utilization and third-party payments
Melton, L. D. (2010) · Carolina Digital Repository (University of North Carolina at Chapel Hill) · doi:10.17615/dnq4-fa86
Segmentation of Symptomatic Exudate-Associated Derangements in 3D OCT Images
Pan, L., & Chen, X. (2019) · Biological and medical physics, biomedical engineering · doi:10.1007/978-981-13-1825-2_12
Development and Cross-Validation of a Cadence-Based Metabolic Equation for Walking
Moore, C. C. (2019) · Scholarworks (University of Massachusetts Amherst) · doi:10.7275/13986840
Development of equations for converting random-zero to automated oscillometric blood pressure values
Yan, L., Wen, X., Dyer, A. R., Chen, H., Zhou, L., Elliott, P., Wu, Y., Chan, Q. M., & Zhao, L. (2019) · Wellcome Open Research · doi:10.12688/wellcomeopenres.15407.1
Raste, Y. (2016) · Spiral (Imperial College London) · doi:10.25560/55133
Fundamentals of assay development and validation
Halim, A. B. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816121-0.00006-4
CMR quantitative measurements of myocardial blood flow: Not ready for routine clinical application
Gewirtz, H. (2019) · Journal of Nuclear Cardiology · doi:10.1007/s12350-019-01812-x
Full-Range Liver Fat Fraction Estimation in Magnitude MRI Using a Signal Shape Descriptor
Costa, Y. A., Filho, C. P., Flores, G. A., Rodrigues, E. L. L., & Paiva, F. F. (2019) · Concepts in Magnetic Resonance Part A · doi:10.1155/2019/3439468
Developing a pipeline for gait analysis with a side-view depth sensor
Hynes, A. (2019) · Memorial University Research Repository (Memorial University)
A proposed field test for evaluating fitness in elderly hypertensive patients.
Eales, C. J., & Stewart, A. (1997) · South African Journal of Physiotherapy · doi:10.4102/sajp.v53i2.1362
Are Currently Used Bioimpedance Methods in Hemodialysis Comparable for Calculating Dialysis Dose?
Arias‐Guillén, M., Massó, E., Gómez, M., Rodas, L. M., Broseta, J. J., Vera, M., Ríos, J., Fontseré, N., & Maduell, F. (2019) · Therapeutic Apheresis and Dialysis · doi:10.1111/1744-9987.13424 · Cited by 2
The inter-rater reliability of the Performance Oriented Mobility Assessment tool after brain surgery
Galloway, A., Killan, E. C., & McHugh, G. A. (2019) · International Journal of Therapy and Rehabilitation · doi:10.12968/ijtr.2018.0135
Himuro, N., Nishibu, H., Abe, H., & Mori, M. (2019) · Physical & Occupational Therapy In Pediatrics · doi:10.1080/01942638.2019.1609150
Motsa, P. L. (2018) · UpSpace Institutional Repository (University of Pretoria)
Wan, Y. (2019) · Carolina Digital Repository (University of North Carolina at Chapel Hill) · doi:10.17615/yaq4-xv58
The Effects of Dehydration and Moderate Alcohol Consumption on Human Behaviour and Performance
Irwin, C. G. (2014) · Griffith Research Online · doi:10.25904/1912/1471
Haemodynamic studies of the eye
Williamson, T. H. (1995) · Enlighten: Theses (The University of Glasgow) · doi:10.5525/gla.thesis.71807
Assessment and Evaluation of Body Temperature
Grodzinsky, E., & Sund‐Levander, M. (2019) · Springer eBooks · doi:10.1007/978-3-030-21886-7_7
McKenzie, D. C. L. (1999) · Enlighten: Theses (The University of Glasgow) · doi:10.5525/gla.thesis.71276
Guimarães, N. S., Guimarães, M. M. M., Kakehasi, A. M., Caporali, J. F. D. M., & Tupinambás, U. (2019) · Revista da Associação Brasileira de Nutrição - RASBRAN
Akano, K. O., Fatunmbi, B. S., Ntadom, G. N., Ayede, A. I., Aderoyeje, T., Bakre, A. G., Alebiosu, O. T., Akpoborie, O., Okafor, C., Gbotosho, G. O., et al. (2019) · Parasite · doi:10.1051/parasite/2019058
Portable Sleep Studies for Diagnosis of Sleep Apnea – Where We are Today?
Suri, J. C. (2006) · Indian Journal of Sleep Medicine · doi:10.5005/ijsm-1-2-65
Koidis, F. (2020) · University of Surrey Open Research repository · doi:10.15126/thesis.00852053
Investigating the Mechanism and Species-Specificity of Thalidomide Derivatives
Fink, E. C. (2018) · Digital Access to Scholarship at Harvard (DASH) (Harvard University)
Wang, Y. (2019) · The Atrium (University of Guelph)
Non-invasive Vascular Structure and Pathology Using Very-high Resolution Ultrasound
Sundholm, J. K. M. (2019) · Helda - University of Helsinki Institutional Repository
López-Carranza, A. C., & Hierro-Gutiérrez, E. G. D. (2019) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-030-30648-9_188
Valente, A. R., Hall, A. O., Alvelos, H., Leahy, M. M., & Jesus, L. M. T. (2018) · Logopedics Phoniatrics Vocology · doi:10.1080/14015439.2018.1458898
Linear Regression Models for Fat Free Mass Measurement Based on Bioelectrical Impedance Analysis
Fahim, T. A., Anower, M. S., Khatun, M. F., & Zuhori, S. T. (2019) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2019.8861576
Kayser, R., Schaaf, T., & Heyde, C. (2019) · Manuelle Medizin · doi:10.1007/s00337-019-00604-1
Impacts of Camera Frame Pacing for Video Recording on Time-Related Applications
Tangjui, N., & Taeprasartsit, P. (2019) · International Joint Conference on Computer Science and Software Engineering · doi:10.1109/jcsse.2019.8864200
García, D. L., Bártulos, A. V., Rosas, J. A. A., Plana, M., & Sánchez, J. (2018) · Seram
Heumann, K. J., Cimolino, J., Hawkins, J. R., Pettitt, R. W., & Murray, S. R. (2016) · International journal of exercise science · doi:10.70252/cxst7608
La calidad temporal de registros en balonmano
Pic, M. (2019) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Hanusovska, E., & Sufliarska, S. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.89845
Calculating critical power and the finite work capacity from a single all-out cycling test
Wright, J. (2019) · Southampton Solent University Digital Library
Development of a method for automating effective patient diameter estimation for digital radiography
Worrall, M. (2019) · Discovery Research Portal (University of Dundee)
Virtual Lower Limb Stroke Rehabilitation to Assess Post Stroke Patients
Jian, L. W., & Shamsuddin, S. N. W. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-34032-2_31
Barry, N. O. K., Djité, M., Kandji, P. M., Ndour, E. H. M., Gueye-Tall, F., Hader, K., Lopez, P., & Guéye, P. M. (2019) · Revue Francophone des Laboratoires · doi:10.1016/s1773-035x(19)30487-3
Erratum zu: Charakterisierung eines geschlossenen Logatomtests
Hörmann, L., Ambrosch, P., & Hey, M. (2019) · HNO · doi:10.1007/s00106-019-00791-2
Blood pressure variability following ischaemic stroke
Davison, W. J. (2019) · UEA Digital Repository (University of East Anglia)
Cardiac Output Measurements in Young Children: Comment
Morey, T. E. (2019) · Anesthesiology · doi:10.1097/aln.0000000000003021
Clinical studies comparing laparoscopic and minilaparotomy cholecystectomy
McMAHON, A. J. (1993) · Enlighten: Theses (The University of Glasgow)
Análisis Rasch de la medida de cooperación del paciente ortodóncico en adolescentes de Medellín
Ochoa, S. M. R., Cárdenas, J. M., Sierra, Á., & Rojas‐Gualdrón, D. F. (2018) · CES Psicología · doi:10.21615/cesp.12.1.4
Quality Assessment of Real-Life Performance of Home Mechanical Ventilators
Garmendia, O., Farré, R., González, M., Alonso-Álvarez, M. L., Perez, N., Martí, S., & Montserrat, J. M. (2019) · Archivos de Bronconeumología · doi:10.1016/j.arbres.2019.08.017
Reproducibility of Imaging and Interpretation
Chen, X., & Winter, K. P. (2019) · Elsevier eBooks · doi:10.1016/b978-0-323-60984-5.00019-6
Kamalifar, S., Azari, M. R., Rafieepour, A., Asgari, M., Zendehdel, R., Soori, H., Tavakol, E., Rahmati, A. R., & Ghaziani, M. N. (2019) · DOAJ (DOAJ: Directory of Open Access Journals)
Schmitz, M. E., Chang, K. T., Arnett, N., Kohatsu, L., Lemwayi, R., Mwasekaga, M., Nkengasong, J. N., Bolu, O. O., Mosha, F. S., & Westerman, L. E. (2019) · African Journal of Laboratory Medicine · doi:10.4102/ajlm.v8i1.740
Population biomonitoring of micronutrient intakes in children using urinary spot samples
Leyvraz, M., Bochud, M., Benzi‐Schmid, C., Haldimann, M., Bovet, P., & Chioléro, A. (2019) · European Journal of Nutrition · doi:10.1007/s00394-019-02144-9
Ryll, U. C., Bastiaenen, C. H. G., Iten, N., & van Hedel, H. J. A. (2019) · Physical & Occupational Therapy In Pediatrics · doi:10.1080/01942638.2019.1695698
Hannel, T., Pithawalla, Y. B., Morton, M. J., Wang, J., Gannon, T. J., Wagner, K. A., Jupe, R., & Rostami, A. A. (2019) · Journal of Regulatory Science · doi:10.21423/jrs-v07hannel
Vlajković, M., Stević, M., Slavković, A., Mitić, B., Zivkovic, V. D., Artiko, V. M., & Matovic, M. D. (2019) · Acta Medica Medianae · doi:10.5633/amm.2019.0324
Silva-Rodríguez, A. (2019) · Revista Digital Internacional de Psicología y Ciencia Social · doi:10.22402/j.rdipycs.unam.5.2.2019.237.150-292
An automated system for analysis of mouse movement activity
Mazur-Milecka, M., & Nowakowski, A. (2010) · Cited by 2
Differing uncertainties and Bland-Altman plots: An observation
Sadler, W. A. (2019) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563219894613
Use of allometry and skinfold thicknesses to estimate the fat mass of circumpubertal boys
Abdalla, P. P., Borges, G. A., Carvalho, A. D. S., Borges, F. G., Siqueira, V. A. A. A., Ramos, N. C., & Machado, D. R. L. (2019) · Annals of Human Biology · doi:10.1080/03014460.2019.1686166
Mathematical Models for Fat Free Mass Measurement Based on Bioelectrical Impedance Analysis
Fahim, T. A., & Anower, M. S. (2019) · International Conference on Advances in Science, Engineering and Robotics Technology (ICASERT) · doi:10.1109/icasert.2019.8934477
Bland–Altman plots, rank parameters, and calibration ridit splines
Newson, R. B. (2019)
César, E. P., da Silva, G., & Guilarducci, L. K. (2019) · Fisioterapia em Movimento · doi:10.1590/1980-5918.32.ao50
Pinto-Leite, T., Tixier, F., Upadhaya, T., Gallais, C., Perdrisot, R., & Rest, C. C. L. (2019) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000001129
One-week test-retest reliability of nine binocular tests and saccades used in concussionPreprint
Long, S., Schuster, T., Steele, R. J., Leclerc, S., & Shrier, I. (2019) · medRxiv · doi:10.1101/19011619
Özkaya, Ö., Balcı, G. A., As, H., Çabuk, R., & Norouzi, M. (2020) · Spor Bilimleri Dergisi · doi:10.17644/sbd.606182
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.