Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 45,001–45,100 of 47,868
Rangel, I. D. C., Carvalho, R. D. S., Gonzalez, M. F. D. S. R., Loureço, P. M., de Azevedo, B. P., & Ferry, F. R. D. A. (2020) · Jornal Brasileiro de Doenças Sexualmente Transmissíveis · doi:10.5327/dst-2177-8264-20203216
Lipoproteins, apoprotein A-1 containing particles and the development of atherosclerosis
Vallance, D. T. (1993) · UCL Discovery (University College London) · Cited by 1
A comparison of in-field fat mass evaluation techniques: a practical perspective
Bertuccioli, A., Vici, G. F., Ceci, R. L., Cesanelli, L., Belli, L. V., & Polzonetti, V. (2019) · Nutrafoods
The Functional Assessment of Balance in Concussion (FAB-C) Battery
Manaseer, T. S., Whittaker, J. L., Isaac, C., Schneider, K., & Gross, D. P. (2021) · International Journal of Sports Physical Therapy · doi:10.26603/001c.28157
Suther, K. R., de Lange, C., Brun, H., Svendsmark, R., Nguyen, B., Larsen, S., Smevik, B., Fiane, A. E., Lindberg, H. L., & Hopp, E. (2021) · Congenital Heart Disease · doi:10.32604/chd.2021.014164
Mandibular Ramus Heights In Patients With Unilateral Posterior Crossbite
Gerkowicz, L. (2020) · University of Minnesota Digital Conservancy (University of Minnesota)
Noble, L. D., Scott, L. E., Bongwe, A., Silva, P. D., & Stevens, W. S. (2021) · Diagnostics · doi:10.3390/diagnostics11020160
Presentación del Volumen 7 Número 1
Guarneros-Reyes, E., & Quezada, M. E. (2021) · Revista Digital Internacional de Psicología y Ciencia Social · doi:10.22402/j.rdipycs.unam.7.1.2021.352.13-21
Ohagwu, C. C., Amogu, F. I., Abonyi, L. C., Ochie, K., Eze, C. U., & Ezechukwu, U. N. (2021) · Journal of diagnostic medical sonography · doi:10.1177/8756479320983306
Correlation of Test Sets and Actual Clinical Performance
Seidenwurm, D. J., & Rosenberg, R. D. (2021) · Radiology Imaging Cancer · doi:10.1148/rycan.2021200139
Amusan, O. O., Musa, K. O., Aribaba, O. T., Aina, A. S., Onakoya, A. O., & Akinsola, F. B. (2021) · Journal of Clinical Sciences · doi:10.4103/jcls.jcls_36_20 · Cited by 1
Renal MRI from Niche Application to New Tool in Nephrology
Boer, A. D. (2020) · Utrecht University Repository (Utrecht University) · doi:10.33540/465
Sasaki, T., Kunimutsu, K., Tanaka, N., Nakamoto, M., Fujii, A., Tanaka, T., Ariyoshi, T., Omuro, T., Omuro, A., Wada, Y., et al. (2021) · doi:10.22541/au.161208184.40323751/v1
Yolles, J. N., & Lee‐Stubbs, R. B. (2021) · Journal of the American Association for Laboratory Animal Science · doi:10.30802/aalas-jaalas-20-000054 · Cited by 1
Fuzzy C-means measurement of mass base on image features
Zhang, X., Lao, H., Wu, D., Liang, C., Liang, B., & Ma, L. (2021) · Journal of Intelligent & Fuzzy Systems · doi:10.3233/jifs-189703
Models for duration and event history data
Berridge, D. M., & Crouchley, R. (2011) · CRC Press eBooks · doi:10.1201/b10850-19
A Home-Based Self-administered Assessment of Neck Proprioception
Basteris, A., Tornbjerg, C. E., Leth, F. B., & Wiil, U. K. (2021) · Lecture notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-030-70569-5_9
Pérez-Sánchez, L. I., Gutierrez-Vazquez, J., Satrustegui-Lapetra, M., Ferreira-Manuel, F., Arévalo-Manso, J. J., Gómez-Herrera, J. J., & Criado‐Álvarez, J. J. (2021) · International Ophthalmology · doi:10.1007/s10792-021-01748-7
The comparison of Architect SCC and cobas SCC tests
Wójcik, E., Reinfuss, K., Stasik, Z., Rychlik, U., Tarapacz, J., & Kulpa, J. (2017) · Diagnostyka Laboratoryjna · doi:10.5604/01.3001.0013.7975
Szili‐Törok, T., Kardos, A., Rudas, L., Paprika, D., McLuckie, A., Beale, R. J., Bihari, S., Keller, H., Seltzer, N., Weimer, A., et al. (1996) · Intensive Care Medicine · doi:10.1007/bf03216414
Ong, A., Sujae, I. H., & Hamill, J. (2020) · ISBS Proceedings Archive
Berner, C., Marculescu, R., Frommlet, F., Kurnikowski, A., Schairer, B., Aigner, C., Bieglmayer, C., & Hecking, M. (2021) · Kidney Medicine · doi:10.1016/j.xkme.2020.12.015
Salomão, A. E., Leite, C. F., de Castro, S. S., Shimano, S. G. N., Silveira, L. S., & Pereira, K. (2021) · Saúde e Desenvolvimento Humano · doi:10.18316/sdh.v9i1.6295 · Cited by 3
Lombard, A., Mistry, H. B., Chapman, S. C., Gueorguieva, I., Aarons, L. J., & Ogungbenro, K. (2021) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2021.105781
Beytell, L. (2019) · UpSpace Institutional Repository (University of Pretoria)
PREDICCIÓN DEL UMBRAL ANAERÓBICO EN EL EJERCICIO PRENSA DE PIERNAS A 45°
Campos, Y. A. C., Vianna, J. M., Guimarães, M. P., de Souza, H. L. R., Silva, G. P., Domínguez, R., da Silva, S. F., Novaes, J. D. S., & Reis, V. M. (2021) · Revista Internacional de Medicina y Ciencias de la Actividad Física y del Deporte · doi:10.15366/rimcafd2021.81.006 · Cited by 1
Burrus, C., Vuistiner, P., Léger, B., & Lüthi, F. (2021) · Journal of Occupational Rehabilitation · doi:10.1007/s10926-021-09968-5
Partners of patients with acquired brain injury: impact, dyadic relationships and support
Cox, V. C. (2020) · Utrecht University Repository (Utrecht University) · doi:10.33540/381
Brünner, M. D. L. M. R., Cieri, M. E., Butler, C., & Cuestas, E. (2021) · Developmental Medicine & Child Neurology · doi:10.1111/dmcn.14863
Clinical Validation of ELISA Assays for Insulin-Like Growth Factor-II (IGF-II)
Redding (2012) · Journal of Endocrinology and Metabolism · doi:10.4021/jem82w
Pharmacokinetic model‐controlled infusion of midazolara
Skipsey, I. G., Colvin, J., Mackenzie, N., & Kenny, G. N. C. (1993) · Anaesthesia · doi:10.1111/j.1365-2044.1993.tb07609.x
Accuracy of peak flow meters. Readings vary between measurements.
Barrett, T. C. (1994) · Europe PMC (PubMed Central)
Neonatal sulfur amino acid metabolism
Riedijk, M. A. (2008) · Data Archiving and Networked Services (DANS)
Pathological fractures of long bones due to bone metastases
Sander, P. D., & Guterson, D. (2010)
Bayesian Hierarchical Methods for Network Meta-Analysis
Zhang, C., & Yuan, Z. (2014)
Aspects of lung mechanics during mechanical ventilation
Guðmundsson, M. (2021) · Gothenburg University Publications Electronic Archive (Gothenburg University)
Comparison of Methods of Poverty Rates Measurement
Sączewska-Piotrowska, A. (2021) · Springer proceedings in business and economics · doi:10.1007/978-3-030-63970-9_18
Kampik, A., Vater, M., & Hartmann, C. J. (2011)
Uncertainty Estimation of Biomedical Oximeters: Proposal for an Experimental Test-Bench
Marchionni, P., Nobile, S., Carnielli, V. P., & Scalise, L. (2021) · Journal of Verification Validation and Uncertainty Quantification · doi:10.1115/1.4050721
Zanella, P. B. (2021) · Clinical Nutrition · doi:10.1016/j.clnu.2021.03.025
Assessments of Dietary Intakes of Canadian Armed Forces Consuming Field Rations
Ahmed, M. (2017) · TSpace (University of Toronto) · Cited by 1
Buescher, J., Weisrock, F., Fritschka, M., Beckmann, S., Litmeier, S., Tahirović, E., Radenovic, S., Busjahn, A., Krahn, T., Dinh, W., et al. (2021) · International Journal of Cardiovascular Research
Amin, M. R., & Ali, M. (2021) · Maternal and Child Nutrition · doi:10.1111/mcn.13195
Left ventricular remodeling and function in ischemic heart disease and aortic valve disease
Jenner, J. (2021) · Figshare
Dion, M.-O., Faure, P.-A., May, O., Bonin, N., Beaulé, P. E., Carsen, S., Nault, M., Pelet, S., Simonyan, D., & Belzile, É. L. (2021) · Revue de Chirurgie Orthopédique et Traumatologique · doi:10.1016/j.rcot.2021.02.015
Leuschner, M. (2019) · UpSpace Institutional Repository (University of Pretoria)
Evaluating intensive language action therapy in the NHS: a feasibility study
Crook, N. (2020) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York)
Proper statistical methods required to compare clinical measurements
Ostrin, L. A., & Glasser, A. (2005) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2005.03.039
Bohač, M., Biščević, A., Gabrić, I., Gabrić, K., Shijakova, V., & Patel, S. (2021) · Seminars in Ophthalmology · doi:10.1080/08820538.2021.1928243
Assessment of tricuspid annulus: anatomic and echocardiographic correlation
Parra, V. M., Fita, G., Pomar, J. L., Rovira, I., Berrebi, A., & Sitges, M. (2021) · International journal of cardiac imaging · doi:10.1007/s10554-021-02188-1
Usefulness of Refractive Measurement by Wavefront Aberrometer in Children
Oh, S. E., Whang, W. J., & Park, M. R. (2021) · Journal of the Korean Ophthalmological Society · doi:10.3341/jkos.2021.62.5.680
Sahota, D. S., Tsang, F. H. K., Gu, J. S., Fung, W. K. V., Mok, K. Y., & Wong, C. L. (2021) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2021.1929439
BABACAN, Ş., & Kılıç, İ. (2021) · Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi · doi:10.19113/sdufenbed.898845
Quantifying & Characterising Peak Intensities of Professional Rugby using GPS & Accelerometers
Howe, S. (2020) · Victoria University Research Repository (Victoria University) · Cited by 1
Barroso, R. D. R. F., Aquino, R., & Amorim, L. D. A. F. (2021) · Research Society and Development · doi:10.33448/rsd-v10i6.16075 · Cited by 1
IL CONDENSATO DELL'ARIA ESPIRATA NELLO STUDIO DI PATOLOGIE RESPIRATORIE PEDIATRICHE
Carraro, S. (2010) · Padua Research Archive (University of Padova)
Error management climate: Factors impacting on learning from errors and error avoidance
Stasiak, K. (2021) · UWA Profiles and Research Repository (University of Western Australia) · doi:10.26182/9ssk-w233 · Cited by 1
Prediction of underwater residual lung volume in healthy men and women
Cicone, Z. S., Nickerson, B. S., & Esco, M. R. (2021) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12719
Bulow, A. (2019) · Mspace (University of Manitoba) · Cited by 1
Comparison of keratometry data using handheld and table-mounted instruments in healthy adults
Olshaker, H., Buhbut, O., Achiron, A., Dotan, G., Levy, I., Tuuminen, R., Gershoni, A., Bahar, I., & Elbaz, U. (2021) · International Ophthalmology · doi:10.1007/s10792-021-01909-8
Measurement of Axial Length by Applanation Ultrasound Relative to Optical Biometry in Normal Eye
Ali, Z., & Abdulkareem, S. (2021) · Iraqi postgraduate Medical Journal · doi:10.52573/ipmj.2021.167823
Peters, P. C. (1995) · UCL Discovery (University College London)
Heart Rate Assessment Technologies for Neonatal Resuscitation
Johnson, P. A. (2020) · ERA: Education and Research Archive (University of Alberta) · doi:10.7939/r3-sjqk-cc04
Dairo, Y. M. (2017) · Radar (Oxford Brookes University) · doi:10.24384/a8tb-w925
Ancillary Testing in the Management of Retinal Vein Occlusions
Browning, D. J. (2012) · Springer eBooks · doi:10.1007/978-1-4614-3439-9_8
Automated Decision Support System for Traumatic Injuries
Farzaneh, N. (2021) · Deep Blue (University of Michigan) · doi:10.7302/1492
Blutdruck-Selbstmessung vs. ambulantes 24-h-Blutdruckmonitoring: Welches ist die bessere Methode?
Holm, D., Steurer, J., & Vetter, W. (1994) · Steinkopff eBooks · doi:10.1007/978-3-642-85428-6_7
Ong, A. M. (2020) · eScholarship@McGill (McGill) · doi:10.82308/54884
Kudrna, J. J., Habbe, E., Bordewyk, A. N., Eisenbeisz, H. C., Scarborough, R., Spencer, T. S., & Eye Care Associates of Nevada, R. (2021) · Aesculapius · doi:10.70657/ahsm.v5.2021.03
Validation of a Noninvasive Measurement of Regional Hemoglobin Oxygen Saturation
Pollard, V., DeMelo, E., Deyo, D. J., Dalmeida, R. E., Widman, R. A., & Prough, D. S. (1995) · Springer eBooks · doi:10.1007/978-4-431-68522-7_24
Viecelli, C., Aguayo, D., Dällenbach, S., Graf, D., Achermann, B. B., Hafen, E., & Füchslin, R. M. (2021) · PLoS ONE · doi:10.1371/journal.pone.0254164
Presentación del Número Volumen 7 | Número 2 |Julio-Diciembre 2021
Quezada, M. E. (2021) · Revista Digital Internacional de Psicología y Ciencia Social · doi:10.22402/j.rdipycs.unam.7.2.2021.383.170-179
Considerations When Using a Statistical Learning Model to Predict Corneal Edema Resolution
Neuman, G. (2021) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2021.2952
Rezende, C. F., Mancuzo, E. V., Nunes, M. C. P., & Corrêa, R. D. A. (2021) · Research Square · doi:10.21203/rs.3.rs-738879/v1
Skervin, T. K. (2021) · Liverpool John Moores University · doi:10.24377/ljmu.t.00015358
Robshaw, D. C. (2021) · Liverpool John Moores University · doi:10.24377/ljmu.t.00015312 · Cited by 1
A Study of Nonprofit Governance through the Lens of Stewardship Theory
Humphrey, D. D. (2020) · University of North Texas Digital Library (University of North Texas) · doi:10.12794/metadc1703358
Oculomotor and functional characteristics of bilateral central vision loss
Arango, T. (2021) · Digital Repository Service (Northeastern University) · doi:10.17760/d20413941
Schneider, D. J. (2021) · RIT Scholar Works (Rochester Institute of Technology)
Tozawa, R., Minamoto, Y., Asada, N., Arai, S., Hirano, M., Kawasaki, T., Akagi, R., & Katoh, M. (2021) · Rigakuryoho Kagaku · doi:10.1589/rika.36.543
Hawkins, J., Hires, C., Dunne, E., & Keenan, L. (2021) · Journal of Environmental and Public Health · doi:10.1155/2021/9924621
Ramzannezhad, A., Hayati, A. N., Bahari, A., & Najafi‐Ashtiani, H. (2021) · Europe PMC (PubMed Central) · doi:10.22038/ijbms.2021.53918.12120
Augenheilkunde, A., & Zrenner, E. (2004)
Evaluations of Devices for Measurement of Cardiac Output
Squara, P. (2021) · Springer eBooks · doi:10.1007/978-3-030-73387-2_21
Clinical muscle strength measurements: reference values and reliability
Douma, R. K. (2021) · University of Groningen research database (University of Groningen / Centre for Information Technology) · doi:10.33612/diss.180382798
The reliability of isometric neck strength assessments in trained individuals
Palfreyman, L., Ridgeon, N., & Jones, T. (2021) · The Journal of Sport and Exercise Science · doi:10.36905/jses.2021.03.08
LABORATORY VERSUS ECOLOGICAL RUNNING: A COMPARISON OF FOOT STRIKE ANGLE AND PATTERN ESTIMATION
Moore, S. R., Kranzinger, C., Strutzenberger, G., Taudes, M., Martínez, A., Schwameder, H., & Kröll, J. (2021) · ISBS Proceedings Archive
Rosfors, S., Modin, A., & Petrini, J. (2021) · International Journal of Angiology · doi:10.1055/s-0041-1735237
Bain, C. (2021) · PEARL (University of Plymouth) · doi:10.24382/1082
Nisi, F., Melchiorri, C., Grigoli, P. D., Giustiniano, E., Cerutti, E., Rispoli, P., & Balagna, R. (2021) · Surgeries · doi:10.3390/surgeries2040034
Kinematics and Kinetics of Sit-to-Stand Activity in Normal and High BMI Subjects
Huffman, K. D. (2014)
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.