STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 6,801–6,900 of 47,868
Objective measurement of breast cancer oestrogen receptor status through digital image analysis
Mofidi, R., Walsh, R., Ridgway, P. F., Crotty, T. B., McDermott, E. W. M., Keaveny, T. V., Duffy, M. J., Hill, A. D. K., & O’Higgins, N. J. (2003) · European Journal of Surgical Oncology · doi:10.1053/ejso.2002.1373 · Cited by 69
Rossi, F., Dia, F. D., Galipò, O., Pistorio, A., Valle, M., Magni‐Manzoni, S., Ruperto, N., Tomà, P., Martini, A., & Ravelli, A. (2006) · Arthritis Care & Research · doi:10.1002/art.22246 · Cited by 69
Impact of transient hypotension on regional cerebral blood flow in humans
Lewis, N. C. S., Smith, K. J., Bain, A. R., Wildfong, K. W., Numan, T., & Ainslie, P. N. (2015) · Clinical Science · doi:10.1042/cs20140751 · Cited by 69
Duroux, P., Emde, C., Bauerfeind, P., Francis, C., Grisel, A., Thybaud, L., Arstrong, D., Depeursinge, C., & Blum, A. L. (1991) · Gut · doi:10.1136/gut.32.3.240 · Cited by 69
Huang, J., Pesudovs, K., Wen, D., Chen, S., Wright, T., Wang, X., Li, Y., & Wang, Q. (2011) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2010.08.044 · Cited by 69
Doesch, C., Streitner, F., Bellm, S., Suselbeck, T., Haghi, D., Heggemann, F., Schoenberg, S. O., Michaely, H., Borggrefe, M., & Papavassiliu, T. (2013) · Obesity · doi:10.1002/oby.20149 · Cited by 70
Fabel, M., von Tengg‐Kobligk, H., Giesel, F. L., Bornemann, L., Dicken, V., Kopp‐Schneider, A., Moser, C., Delorme, S., & Kauczor, H. (2008) · European Radiology · doi:10.1007/s00330-008-0866-4 · Cited by 69
Manresa, J. A. B., Neziri, A. Y., Curatolo, M., Arendt‐Nielsen, L., & Andersen, O. K. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1634-0 · Cited by 70
Nowomiejska, K., Vonthein, R., Paetzold, J., Zagorski, Z., Kardon, R. H., & Schiefer, U. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2004.12.047 · Cited by 69
Yang, S. J., Han, Y., Song, G. I., Lee, C. H., & Sohn, S. W. (2013) · Clinical and Experimental Optometry · doi:10.1111/cxo.12056 · Cited by 69
Gustafsson, A., Arnrup, K., Broberg, A. G., Bodin, L., & Berggren, U. (2010) · Community Dentistry And Oral Epidemiology · doi:10.1111/j.1600-0528.2009.00521.x · Cited by 69
Lembcke, A. E., Dohmen, P. M., Dewey, M., Klessen, C., Elgeti, T., Hermann, K., Konertz, W. F., Hamm, B., & Kivelitz, D. E. (2005) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2004.09.030 · Cited by 69
Dyson, K. S., Shoemaker, J. K., Arbeille, P., & Hughson, R. L. (2010) · Experimental Physiology · doi:10.1113/expphysiol.2009.050815 · Cited by 69
Hohn, A., Defosse, J., Becker, S., Steffen, C., Wappler, F., & Sakka, S. G. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aet023 · Cited by 77
A Novel Video Game–Based Device for Measuring Stepping Performance and Fall Risk in Older People
Schoene, D., Lord, S. R., Verhoef, P., & Smith, S. T. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.01.012 · Cited by 71
Insulin resistance independently predicts the progression of coronary artery calcification
Lee, K. K., Fortmann, S. P., Fair, J. M., Iribarren, C., Rubin, G. D., Varady, A. N., Go, A. S., Quertermous, T., & Hlatky, M. A. (2009) · American Heart Journal · doi:10.1016/j.ahj.2009.02.006 · Cited by 74
Jamaiyah, H., Geeta, A., Safiza, M. N. N., Khor, G. L., Wong, N. F., Kee, C. C., Rahmah, R., Ahmad, A., Suzana, S., Chen, W. S., et al. (2010) · PubMed · Cited by 69
Roemmich, J. N., Clark, P. A., Walter, K., Patrie, J., Weltman, A., & Rogol, A. D. (2000) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2000.279.6.e1426 · Cited by 69
Accuracy of height and weight data from child health records
Howe, L. D., Tilling, K. M., & Lawlor, D. A. (2009) · Archives of Disease in Childhood · doi:10.1136/adc.2009.162552 · Cited by 78
Esmaeelpour, M., Kajic, V., Zabihian, B., Othara, R., Ansari‐Shahrezaei, S., Kellner, L., Krebs, I., Nemetz, S., Kraus, M. F., Joachim Hornegger, A., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0099690 · Cited by 70
An Arabic version of the Oral Health Impact Profile: translation and psychometric properties
Al-Jundi, M. A., Szentpétery, A., & John, M. T. (2007) · International Dental Journal · doi:10.1111/j.1875-595x.2007.tb00443.x · Cited by 83
Zielinska, E., Liu, D., Wu, H.-Y., Quiroz, J. A., Rappaport, R., & Yang, D.-P. (2005) · Virology Journal · doi:10.1186/1743-422x-2-84 · Cited by 72
Kuznetsova, T., Staessen, J. A., Thijs, L., Kunath, C., Olszanecka, A., Ryabikov, A. N., Tikhonoff, V., Stolarz, K., Bianchi, G., Casiglia, E., et al. (2004) · Circulation · doi:10.1161/01.cir.0000145541.63406.ba · Cited by 69
Alvaro, D., Macarri, G., Mancino, M. G., Marzioni, M., Bragazzi, M. C., Onori, P., Corradini, S. G., Invernizzi, P., Franchitto, A., Attili, A. F., et al. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-147-7-200710020-00003 · Cited by 78
Evaluation of the Accuracy of Different Methods Used to Estimate Weights in the Pediatric Population
So, T.-Y., Farrington, E. A., & Absher, R. K. (2009) · PEDIATRICS · doi:10.1542/peds.2008-1968 · Cited by 69
Sakthong, P., Charoenvisuthiwongs, R., & Shabunthom, R. (2008) · Health and Quality of Life Outcomes · doi:10.1186/1477-7525-6-71 · Cited by 81
Critical view on diagnosing muscle wasting by single-frequency bio-electrical impedance in COPD
Rutten, E. P. A., Spruit, M. A., & Wouters, E. F. �. (2009) · Respiratory Medicine · doi:10.1016/j.rmed.2009.07.004 · Cited by 78
Validity and reliability of critical power field testing
Karsten, B., Jobson, S., Hopker, J., Stevens, L., & Beedie, C. (2014) · European Journal of Applied Physiology · doi:10.1007/s00421-014-3001-z · Cited by 69
Thierfelder, K. M., Sommer, W. H., Baumann, A. B., Klotz, E., Meinel, F. G., Strobl, F. F., Nikolaou, K., Reiser, M. F., & von Baumgarten, L. (2013) · Neuroradiology · doi:10.1007/s00234-013-1179-0 · Cited by 69
Real-life step and activity measurement: reliability and validity
Busse, M. E., van Deursen, R. W., & Wiles, C. M. (2009) · Journal of Medical Engineering & Technology · doi:10.1080/03091900701682606 · Cited by 69
Influence of counting chamber type on CASA outcomes of equine semen analysis
Hoogewijs, M., Vliegher, S. D., Govaere, J., Schauwer, C. D., de Kruif, A., & Soom, A. V. (2011) · Equine Veterinary Journal · doi:10.1111/j.2042-3306.2011.00523.x · Cited by 69
New Automated Multiplex Assay for Bone Turnover Markers in Osteoporosis
Claudon, A., Vergnaud, P., Valverde, C., Mayr, A., Klause, U., & Garnero, P. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2008.105866 · Cited by 69
Lewis, J. R., Schousboe, J. T., Lim, W. H., Wong, G., Zhu, K., Lim, E. M., Wilson, K. E., Thompson, P. L., Kiel, D. P., & Prince, R. L. (2015) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.115.306383 · Cited by 73
MacIsaac, R. J., Ekinci, E. I., Premaratne, E., Lu, Z. X., Seah, J., Li, Y., Boston, R., Ward, G. M., & Jerums, G. (2015) · BMC Nephrology · doi:10.1186/s12882-015-0196-0 · Cited by 76
Upper-limb Power Test in Rock-climbing
Laffaye, G., Collin, J. ‐., Levernier, G., & Padulo, J. (2014) · International Journal of Sports Medicine · doi:10.1055/s-0033-1358473 · Cited by 69
Simultaneous validation of five activity monitors for use in adult populations
Powell, C., Carson, B. P., Dowd, K. P., & Donnelly, A. E. (2017) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.12813 · Cited by 70
Gómez‐Ambrosi, J., González-Crespo, I., Catalán, V., Rodríguez, A., Moncada, R., Valentí, V., Romero, S., Ramírez, B., Silva, C., Gil, M. J., et al. (2017) · Clinical Nutrition · doi:10.1016/j.clnu.2017.01.010 · Cited by 72
Nie, J., Wu, X., Ma, J., Cao, S., Huang, W., Liu, Q., Li, X., Li, Y., & Wang, Y. (2017) · Scientific Reports · doi:10.1038/srep42769 · Cited by 75
A time-frequency domain approach of heart rate estimation from photoplethysmographic (PPG) signal
Islam, M. T., Zabir, I., Ahamed, S. T., Yasar, M. T., Shahnaz, C., & Fattah, S. A. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.03.020 · Cited by 71
Chaudhari, A. S., Black, M. S., Eijgenraam, S. M., Wirth, W., Maschek, S., Sveinsson, B., Eckstein, F., Oei, E. H. G., Gold, G. E., & Hargreaves, B. A. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25883 · Cited by 74
Point-of-care device to diagnose and monitor neonatal jaundice in low-resource settings
Keahey, P., Simeral, M. L., Schroder, K. J., Bond, M. M., Mtenthaonga, P., Miros, R., Dube, Q., & Richards-Kortum, R. R. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1714020114 · Cited by 69
Pesonen, A., & Kuula, L. (2018) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7050 · Cited by 71
Gandhi, M., Bacchetti, P., Rodrigues, W. C., Spinelli, M. A., Koss, C. A., Drain, P. K., Baeten, J. M., Mugo, N., Ngure, K., Benet, L. Z., et al. (2018) · EClinicalMedicine · doi:10.1016/j.eclinm.2018.08.004 · Cited by 74
Harwood, R., & Ebrahim, S. B. J. (2002) · Disability and Rehabilitation · doi:10.1080/09638280110101541 · Cited by 69
Pulse contour analysis after normothermic cardiopulmonary bypass in cardiac surgery patients
Sander, M., von Heymann, C., Foer, A., von Dossow, V., Grosse, J., Dushe, S., Konertz, W. F., & Spies, C. (2005) · Critical Care · doi:10.1186/cc3903 · Cited by 69
Evaluation of Air Displacement for Assessing Body Composition of Collegiate Wrestlers
UTTER, A. C., GOSS, F. L., SWAN, P. D., HARRIS, G. S., ROBERTSON, R. J., & TRONE, G. A. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000053726.16625.d5 · Cited by 69
Richardson, M. G., & Wissler, R. N. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199701000-00018 · Cited by 69
Neuhauser, H. K., Ellert, U., & Kurth, B. (2005) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/01.hjr.0000183909.52118.9f · Cited by 74
Chua, T., YIN, L. C., Thiang, T. H., Choo, T. B., Ping, D. Z., & Leng, L. Y. (2000) · Journal of Nuclear Cardiology · doi:10.1067/mnc.2000.105279 · Cited by 69
Shiota, T., Sinclair, B. G., Ishii, M., Zhou, X., Ge, S., Teien, D. E., Gharib, M., & Sahn, D. J. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(96)00009-5 · Cited by 69
Aarts, N. J. M., Schurink, G. W. H., Kool, L. J. S., Bode, P. J., van Baalen, J. M., Hermans, J., & van Bockel, J. H. (1999) · European Journal of Vascular and Endovascular Surgery · doi:10.1053/ejvs.1999.0883 · Cited by 69
The bi-pedal ape: Plasticity and asymmetry in footedness
Carey, D. P., Smith, D. T., Martin, D. S., Smith, G., Skriver, J., Rutland, A., & Shepherd, J. W. (2008) · Cortex · doi:10.1016/j.cortex.2008.05.011 · Cited by 84
Sridharan, S., Derrick, G. P., Deanfield, J. E., & Taylor, A. M. (2006) · Heart · doi:10.1136/hrt.2005.071746 · Cited by 69
Variability in Cobb Angle Measurements Using Reformatted Computerized Tomography Scans
Adam, C. J., Izatt, M. T., Harvey, J. R., & Askin, G. N. (2005) · Spine · doi:10.1097/01.brs.0000169449.68870.f8 · Cited by 69
Gupta, A., Defreitas, G. A., & Lemack, G. E. (2004) · Neurourology and Urodynamics · doi:10.1002/nau.20039 · Cited by 70
Oxygen-enhanced MR Imaging: Correlation with Postsurgical Lung Function in Patients with Lung Cancer
Ohno, Y., Hatabu, H., Higashino, T., Nogami, M., Takenaka, D., Watanabe, H., CAUTEREN, M. V., Yoshimura, M., Satouchi, M., Nishimura, Y., et al. (2005) · Radiology · doi:10.1148/radiol.2361040005 · Cited by 69
Trigg, R., & WOOD, V. A. (2000) · Clinical Rehabilitation · doi:10.1191/026921500678119607 · Cited by 70
Marchesoni, A., Battafarano, N., Arreghini, M., Panni, B., Gallazzi, M., & Tosi, S. (2003) · British journal of rheumatology · doi:10.1093/rheumatology/keg394 · Cited by 69
Hustvedt, B.-E., Christophersen, A., Johnsen, L. R., Tomten, H., McNeill, G., Haggarty, P., & Løvø, A. (2004) · British Journal of Nutrition · doi:10.1079/bjn20041272 · Cited by 69
The Use of Three-Dimensional Ultrasound for Thyroid Volumetry
Schlögl, S., Werner, E., Laßmann, M., Terekhova, J., Muffert, S., Seybold, S., & Reiners, C. (2001) · Thyroid · doi:10.1089/105072501750302877 · Cited by 69
Comparison between creatinine and cystatin C-based GFR equations in renal transplantation
Zahran, A., Qureshi, M., & Shoker, A. (2007) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfm243 · Cited by 70
Rossier, P., & Wade, D. T. (2002) · Clinical Rehabilitation · doi:10.1191/0269215502cr447oa · Cited by 82
Buchvald, F. F., & Bisgaard, H. F. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.3.2004233 · Cited by 69
Determination ef ventricular volumes in human fetal hearts by two-dimensional echocardiography
Schmidt, K. G., Silverman, N. H., & Hoffman, J. I. E. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80365-8 · Cited by 69
Ellis, K. J., Shypailo, R. J., & Wong, W. W. (1999) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/70.5.847 · Cited by 77
Ultrasonography in Arthritis of the Knee
Østergaard, M., Court‐Payen, M., Gideon, P., Wieslander, S. B., Cortsen, M. E., Lorenzen, I., & Henriksen, O. M. (1995) · Acta Radiologica · doi:10.1177/028418519503600104 · Cited by 69
Measurement of cardiac output in pregnancy by thoracic electrical bioimpedance and thermodilution
Masaki, D. I., Greenspoon, J. S., & Ouzounian, J. G. (1989) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(89)90379-7 · Cited by 69
Pagano, D., Lewis, M. E., Townend, J., Davies, P., Camici, P. G., & Bonser, R. S. (1999) · Heart · doi:10.1136/hrt.82.6.684 · Cited by 69
Nolan, J., Flapan, A. D., Goodfield, N. E. R., Prescott, R. J., Bloomfield, P. M., Neilson, J. M. M., & Ewing, D. J. (1996) · The American Journal of Cardiology · doi:10.1016/s0002-9149(96)90587-1 · Cited by 69
Matheijssen, N. A. A., Baur, L. H. B., Reiber, J. H. C., van der Velde, E. A., van Dijkman, P. R. M., van der Geest, R. J., Roos, A., & van der Wall, E. E. (1996) · International journal of cardiac imaging · doi:10.1007/bf01798113 · Cited by 73
Whincup, P. H., Bruce, N., Cook, D. G., & Shaper, A. G. (1992) · Journal of Epidemiology & Community Health · doi:10.1136/jech.46.2.164 · Cited by 71
Microarray segmentation methods significantly influence data precision
Ahmed, A., Vias, M., Iyer, N. G., Caldas, C., & Brenton, J. D. (2004) · Nucleic Acids Research · doi:10.1093/nar/gnh047 · Cited by 76
Benraad, T. J., Geurts-Moespot, J., Grøndahl-Hansen, J., Schmitt, M., Heuvel, J. J. T. M., Witte, J., Foekens, J. A., Leake, R. E., Brünner, N., & Sweep, F. C. G. J. (1996) · European Journal of Cancer · doi:10.1016/0959-8049(96)00118-9 · Cited by 69
Rate of change in abdominal aortic aneurysm diameter after endovascular repair
Wolf, Y. G., Hill, B. B., Rubin, G. D., Fogarty, T. J., & Zarins, C. K. (2000) · Journal of Vascular Surgery · doi:10.1067/mva.2000.107754 · Cited by 69
Estimates of food and macronutrient intake in a random sample of Northern Ireland adolescents
Strain, J. J., Robson, P. J., Livingstone, M. B. E., Primrose, E. D., Savage, J. M., Cran, G. W., & Boreham, C. A. G. (1994) · British Journal Of Nutrition · doi:10.1079/bjn19940038 · Cited by 75
Annals of Clinical Biochemistry
(1996) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329603300125 · Cited by 69
blandr: Bland-Altman Method Comparison
Datta, D. (2017) · doi:10.32614/cran.package.blandr · Cited by 69
Colle, F., Rannou, F., Revel, M., Fermanian, J., & Poiraudeau, S. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.35657 · Cited by 68
Validation and verification of measurement methods in clinical chemistry
Theodorsson, E. (2012) · Bioanalysis · doi:10.4155/bio.11.311 · Cited by 68
Høidrup, S., Andreasen, A., Osler, M., Pedersen, A., Jørgensen, L., Jørgensen, T., Schroll, M., & Heitmann, B. (2002) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601292 · Cited by 68
Bellèvre, D., Manrique, A., Legallois, D., Bross, S., Baavour, R., Roth, N., Blaire, T., Desmonts, C., Bailliez, A., & Agostini, D. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3141-3 · Cited by 71
Pattaro, C., Riegler, P., Stifter, G., Modenese, M., Minelli, C., & Pramstaller, P. P. (2013) · Nephron Clinical Practice · doi:10.1159/000351043 · Cited by 80
Vereecken, C. A., Bourdeaudhuij, I. D., Maes, L., & on behalf of the HELENA study group (2010) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2010.24 · Cited by 74
Comyn, O., Heng, L. Z., Ikeji, F., Bibi, K., Hykin, P. G., Bainbridge, J. W., & Patel, P. J. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-10895 · Cited by 68
Sukapirom, K., Onlamoon, N., Thepthai, C., Polsrila, K., Tassaneetrithep, B., & Pattanapanyasat, K. (2011) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/qai.0b013e31822866a2 · Cited by 68
Metzelder, S., Coburn, M., Fries, M., Reinges, M. H. T., Reich, S., Rossaint, R., Marx, G., & Rex, S. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer066 · Cited by 70
Clark, B. K., Lynch, B. M., Winkler, E. A., Gardiner, P. A., Healy, G. N., Dunstan, D. W., & Owen, N. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0309-y · Cited by 68
Torsion of the Optic Nerve Head Is a Prominent Feature of Normal-Tension Glaucoma
Park, H. L., Lee, K.-I., Lee, K., Shin, H. Y., & Park, C. K. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.13-12327 · Cited by 68
Prognosis of Adults With Borderline Left Ventricular Ejection Fraction
Tsao, C. W., Lyass, A., Larson, M. G., Cheng, S. C., Lam, C. S. P., Aragam, J. R., Benjamin, E. J., & Vasan, R. S. (2016) · JACC Heart Failure · doi:10.1016/j.jchf.2016.03.003 · Cited by 71
Kadji, C., Cannie, M., Resta, S., Guez, D., Abi-Khalil, F., Angelis, R. D., & Jani, J. C. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.12.031 · Cited by 72
REAVER: A program for improved analysis of high‐resolution vascular network images
Corliss, B. A., Doty, R. W., Mathews, C., Yates, P. A., Zhang, T., & Peirce, S. M. (2020) · Microcirculation · doi:10.1111/micc.12618 · Cited by 78
Kashefi‐Kheyrabadi, L., Koyappayil, A., Kim, T., Cheon, Y., & Lee, M. (2020) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2020.107674 · Cited by 68
smplot: An R Package for Easy and Elegant Data Visualization
Min, S. H., & Zhou, J. (2021) · Frontiers in Genetics · doi:10.3389/fgene.2021.802894 · Cited by 68
Gudelunas, M. K., Lipnick, M. S., Hendrickson, C. M., Vanderburg, S. B., Okunlola, B., Auchus, I., Feiner, J., & Bickler, P. E. (2023) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000006755 · Cited by 69
Siafarikas, F., Stær-Jensen, J. E., Brækken, I. H., Bø, K., & Engh, M. E. (2012) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.11192 · Cited by 69
Bach, A. J. E., Stewart, I. B., Disher, A. E., & Costello, J. T. (2015) · PLoS ONE · doi:10.1371/journal.pone.0117907 · Cited by 78
Body mass index is associated with leukotriene inflammation in asthmatics
Giouleka, P., Papatheodorou, G., Lyberopoulos, P., Karakatsani, A., Alchanatis, M., Roussos, C., Papiris, S. A., & Loukides, S. (2010) · European Journal of Clinical Investigation · doi:10.1111/j.1365-2362.2010.02371.x · Cited by 71
Podbregar, M., & Možina, H. (2007) · Critical Care · doi:10.1186/cc5153 · Cited by 69
Piqué‐Vidal, C., Maled-García, I., Arabi-Moreno, J., & Vila, J. (2006) · Foot & Ankle International · doi:10.1177/107110070602700304 · Cited by 68
van Harlingen, D., Heesterbeek, P. J. C., & Vos, M. (2011) · Acta Orthopaedica · doi:10.3109/17453674.2011.636669 · Cited by 68
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.