STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 6,501–6,600 of 47,868
Lü, Q., Constantin, J., Nieszkowska, A., Elman, M., Vieira, S. R. R., & Rouby, J. (2006) · Critical Care · doi:10.1186/cc4956 · Cited by 77
Houzé, P., Gamra, S., Madelaine, I., Bousquet, B., & Gourmel, B. (2001) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.1018 · Cited by 76
Smit, W., Langedijk, M. J., Schouten, N., van den Berg, N., Struijk, D. G., & Krediet, R. T. (2000) · Peritoneal Dialysis International · doi:10.1177/089686080002000626 · Cited by 72
Blood gases in pregnancy at sea level and at high altitude
McAuliffe, F. M., Kametas, N. A., Krampl, E., Ernsting, J., & Nicolaides, K. H. (2001) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2001.00225.x · Cited by 73
Comparison of Two Methods of Processing Induced Sputum: Selected versus Entire Sputum
Spanevello, A., Beghé, B., Bianchi, A., Migliori, G. B., Ambrosetti, M., Neri, M., & Ind, P. W. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.2.9705095 · Cited by 72
Bedside Diagnostic Blood Testing
Salem, M. (1991) · JAMA · doi:10.1001/jama.1991.03470030082028 · Cited by 72
Cambillau, M., Simon, A. C., Amar, J., Giral, P., Atger, V., Segond, P., Levenson, J. A., Merli, I. P., Mégnien, J. L., & Plainfosse, M. C. (1992) · Arteriosclerosis and Thrombosis A Journal of Vascular Biology · doi:10.1161/01.atv.12.11.1346 · Cited by 81
Haarbo, J., Hassager, C., Jensen, S. B., Riis, B. J., & Christiansen, C. (1991) · The American Journal of Medicine · doi:10.1016/s0002-9343(05)80009-9 · Cited by 78
Physiological Changes Associated with Aging and Immobility
Nigam, Y., KNIGHT, J. C., Bhattacharya, S., & Bayer, A. J. (2012) · Journal of Aging Research · doi:10.1155/2012/468469 · Cited by 91
Williams, J. E. A. (2003) · Thorax · doi:10.1136/thorax.58.6.515 · Cited by 71
Tothill, P., Hannan, W. J., & Wilkinson, S. (2001) · The British Journal of Radiology · doi:10.1259/bjr.74.878.740166 · Cited by 71
Noninvasive Monitoring of Vital Signs Based on Highly Sensitive Fiber Optic Mattress
Wang, S., Ni, X., Li, L., Wang, J., Liu, Q., Yan, Z., Zhang, L., & Sun, Q. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2974313 · Cited by 71
Nocturnal Awakening and Sleep Efficiency Estimation Using Unobtrusively Measured Ballistocardiogram
Jung, D. W., Hwang, S. H., Yoon, H. N., Lee, Y.-J. G., Jeong, D. U., & Park, K. S. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2278020 · Cited by 77
Learning-based heart rate detection from remote photoplethysmography features
Hsu, Y., Lin, Y.-L., & Hsu, W. H. (2014) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2014.6854440 · Cited by 71
Quantitative MRI volumetry of the entorhinal cortex in temporal lobe epilepsy
Salmenpera, T. M., Kälviäinen, R. K., Partanen, K. P. L., & Pitkänen, A. (2000) · Seizure · doi:10.1053/seiz.1999.0373 · Cited by 71
Comparison of methods for assessing integrity of equine sperm membranes
Foster, M. L., Love, C. C., Varner, D. D., Brinsko, S. P., Hinrichs, K., Teague, S. R., LaCaze, K. A., & Blanchard, T. L. (2011) · Theriogenology · doi:10.1016/j.theriogenology.2011.02.012 · Cited by 79
Validation of the Loughborough Soccer Passing Test in Young Soccer Players
Moal, E. L., Rué, O., Ajmol, A., Abderrahman, A. B., Hammami, M. A., Ounis, O. B., Kebsi, W., & Zouhal, H. (2013) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000000296 · Cited by 98
Goldacre, M. J., Lambert, T. W., & Svirko, E. (2012) · Postgraduate Medical Journal · doi:10.1136/postgradmedj-2012-131321 · Cited by 77
Palacios, C. S., Trak‐Fellermeier, M. A., Betancourt, J., JOSHIPURA, K. J., & Tucker, K. L. (2015) · Public Health Nutrition · doi:10.1017/s1368980014003218 · Cited by 73
Nicol, E., Dudley, L., & Bradshaw, D. (2016) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2016.09.006 · Cited by 78
Assessing Reactive Strength Measures in Jumping and Hopping Using the Optojump™ System
Healy, R., Kenny, I. C., & Harrison, A. J. (2016) · Journal of Human Kinetics · doi:10.1515/hukin-2016-0032 · Cited by 71
Software thresholds alter the bias of actigraphy for monitoring sleep in team-sport athletes
Fuller, K. L., Juliff, L. E., Gore, C. J., Peiffer, J. J., & Halson, S. L. (2017) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2016.11.021 · Cited by 82
Zeng, J., Zheng, J., Huang, Z., Chen, S., Liu, J., Wu, T., Zheng, R., & Lu, M. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.03.014 · Cited by 76
Alahmari, K. A., Reddy, R. S., Samuel, P. S., Ahmad, I., Kakaraparthi, V. N., & Mahtab, M. (2017) · Brazilian Journal of Physical Therapy · doi:10.1016/j.bjpt.2017.05.003 · Cited by 73
Burton, E., Hill, K. D., Lautenschlager, N. T., Thøgersen-Ntoumani, C., Lewin, G., Boyle, E., & Howie, E. (2018) · BMC Geriatrics · doi:10.1186/s12877-018-0793-4 · Cited by 70
de Mello, R. A. F., Ma, Y., Ashir, A., Jerban, S., Hoenecke, H. R., Carl, M., Du, J., & Chang, E. Y. (2020) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2020.05.042 · Cited by 80
Ioachimescu, O. C., Allam, J. S., Samarghandi, A., Anand, N., Fields, B. G., Dholakia, S. A., Venkateshiah, S. B., Eisenstein, R., Ciavatta, M.-M., Collop, N. A., et al. (2020) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.8620 · Cited by 75
Savini, G., Taroni, L., Schiano‐Lomoriello, D., & Hoffer, K. J. (2020) · Eye · doi:10.1038/s41433-020-01245-8 · Cited by 76
Setu, M. A. K., Horstmann, J., Schmidt, S., Stern, M. E., & Steven, P. (2021) · Scientific Reports · doi:10.1038/s41598-021-87314-8 · Cited by 78
Jeon, S., & Lee, K. C. (2021) · Progress in Orthodontics · doi:10.1186/s40510-021-00358-4 · Cited by 77
Hill, B. L., Rakocz, N., Rudas, Á., Chiang, J. N., Wang, S., Hofer, I. S., Cannesson, M. P., & Halperin, E. (2021) · Scientific Reports · doi:10.1038/s41598-021-94913-y · Cited by 85
Ali, N., Turkiewicz, A., Hughes, V., Folkesson, E., Tjörnstand, J., Neuman, P., Önnerfjord, P., & Englund, M. (2022) · Molecular & Cellular Proteomics · doi:10.1016/j.mcpro.2022.100200 · Cited by 74
Behavioural comparisons of positional demands in professional soccer.
Taylor, J. B., Mellalieu, S. D., & James, N. (2004) · International Journal of Performance Analysis in Sport · doi:10.1080/24748668.2004.11868294 · Cited by 90
Comparison of four commercial devices for RapidArc and sliding window IMRT QA
Chandraraj, V., Stathakis, S., Manickam, R., Esquivel, C., Supe, S. S., & Papanikolaou, N. (2011) · Journal of Applied Clinical Medical Physics · doi:10.1120/jacmp.v12i2.3367 · Cited by 71
Comparison of Ground Reaction Force Asymmetry in One- and Two-legged Countermovement Jumps
Benjanuvatra, N., Lay, B. S., Alderson, J. A., & BLANKSBY, B. A. (2013) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e318280d28e · Cited by 80
Estimating stroke volume from oxygen pulse during exercise
Crisafulli, A., Piras, F., Chiappori, P., Vitelli, S., Caria, M. A., Lobina, A., Milia, R., Tocco, F., Concu, A., & Melis, F. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/10/006 · Cited by 73
Clancy, R. M., Buyon, J. P., Ikeda, K., Nozawa, K., Argyle, D. A., FRIEDMAN, D. M., & Chan, E. K. L. (2005) · Arthritis & Rheumatism · doi:10.1002/art.21289 · Cited by 71
Performance of Nasal Prongs in Sleep Studies
Hernández, L., Ballester, E., Farré, R., Badia, J. R., Lobelo, R., Navajas, D., & Montserrat, J. M. (2001) · CHEST Journal · doi:10.1378/chest.119.2.442 · Cited by 75
Ikeda, K., MacLeod, D. B., Grocott, H. P., Moretti, E. W., Ames, W. A., & Vacchiano, C. (2014) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000463 · Cited by 76
Schneider, G. M., Jull, G. A., Thomas, K. C., Smith, A. D., Emery, C. A., Faris, P., Schneider, K., & SALO, P. T. (2013) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2013.02.015 · Cited by 74
Acierno, M. J., da Cunha, A. F., Smith, J. A., Tully, T. N., Guzman, D. S.-M., Serra, V. F., & Mitchell, M. A. (2008) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.233.10.1587 · Cited by 79
Salvetat, M. L., Zeppieri, M., Miani, F., Tosoni, C., Parisi, L., & Brusini, P. (2011) · Eye · doi:10.1038/eye.2011.60 · Cited by 71
Minimal model quantification of pulmonary gas exchange in intensive care patients
Karbing, D. S., Kjærgaard, S., Andreassen, S., Espersen, K., & Rees, S. E. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.10.007 · Cited by 71
Martin, G., Tapsell, L. C., Denmeade, S., & Batterham, M. J. (2003) · Preventive Medicine · doi:10.1016/s0091-7435(02)00054-3 · Cited by 78
Hüsser, O., Holzamer, A., Resch, M., Endemann, D., Núñez, J. E., Bodı́, V., Schmid, C., Riegger, G. A. J., Gössmann, H., Hamer, O. W., et al. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.04.182 · Cited by 71
Léderlin, M., Bauman, G., Eichinger, M., Dinkel, J., Brault, M., Biederer, J., & Puderbach, M. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2012.12.003 · Cited by 71
Novelli, L., Ferri, R., & Bruni, O. (2009) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2009.00785.x · Cited by 84
Waele, J. J. D., Cheatham, M. L., Malbrain, M. L. N. G., Kirkpatrick, A. W., Sugrue, M., Balogh, Z. J., Ivatury, R. R., Keulenaer, B. L. D., & Kimball, E. J. (2009) · Acta Clinica Belgica · doi:10.1179/acb.2009.036 · Cited by 75
Korosoglou, G., Youssef, A., Bilchick, K. C., Ibrahim, E.-S. H., Lardo, A. C., Lai, S., & Osman, N. F. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21315 · Cited by 71
Kasuya, Y., Akça, O., Sessler, D. I., Ozaki, M., & Komatsu, R. (2009) · Anesthesiology · doi:10.1097/aln.0b013e3181b060b6 · Cited by 71
Rehm, J. L., Wolfgram, P. M., Hernando, D., Eickhoff, J. C., Allen, D. B., & Reeder, S. B. (2015) · European Radiology · doi:10.1007/s00330-015-3724-1 · Cited by 74
Scattone, D., Raggio, D. J., & May, W. (2011) · Psychological Reports · doi:10.2466/03.10.pr0.109.5.626-634 · Cited by 75
Koley, B. L., & Dey, D. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2282337 · Cited by 81
Validity of uniaxial accelerometry during activities of daily living in children
Eisenmann, J. C., Strath, S. J., Shadrick, D., Rigsby, P., Hirsch, N. M., & Jacobson, L. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0983-3 · Cited by 82
Minassian, A. T., Poirier, N., Pierrot, M., Meneï, P., Granry, J. C., Ursino, M., & Beydon, L. (1999) · Anesthesiology · doi:10.1097/00000542-199910000-00018 · Cited by 71
Evaluation of TEG® and RoTEM® inter-changeability in trauma patients
Hagemo, J. S., Næss, P. A., Johansson, P. I., Windeløv, N. A., Cohen, M. J. M., Røislien, J., Brohi, K., Heier, H. E., Hestnes, M., & Gaarder, C. (2012) · Injury · doi:10.1016/j.injury.2012.11.016 · Cited by 74
A comparison between the AASM 2012 and 2007 definitions for detecting hypopnea
BaHammam, A. S., Obeidat, A., Barataman, K., Bahammam, S. A., Olaish, A. H., & Sharif, M. M. (2014) · Sleep And Breathing · doi:10.1007/s11325-014-0939-3 · Cited by 81
ALEXANDER OSTHAUS, W., HUBER, D., BECK, C., WINTERHALTER, M., BOETHIG, D., WESSEL, A., & SÜMPELMANN, R. (2007) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2007.02210.x · Cited by 70
Tew, G. A., Klonizakis, M., Moss, J., Ruddock, A. D., Saxton, J., & Hodges, G. J. (2010) · Microvascular Research · doi:10.1016/j.mvr.2010.12.001 · Cited by 74
Coronary magnetic resonance angiography and vessel wall imaging in children with Kawasaki disease
Greil, G. F., Seeger, A., Miller, S., Claussen, C. D., Hofbeck, M., Botnar, R. M., & Sieverding, L. (2007) · Pediatric Radiology · doi:10.1007/s00247-007-0498-x · Cited by 71
Iwahori, T., Ueshima, H., Miyagawa, N., Ohgami, N., Yamashita, H., Ohkubo, T., Murakami, Y., Shiga, T., & Miura, K. (2014) · Hypertension Research · doi:10.1038/hr.2014.76 · Cited by 76
The Mallett Fixation Disparity Test: influence of test instructions and relationship with symptoms
Karania, R., & Evans, B. J. W. (2006) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2006.00385.x · Cited by 74
McBride, D. W., Klebe, D. W., Tang, J., & Zhang, J. H. (2015) · Translational Stroke Research · doi:10.1007/s12975-015-0400-3 · Cited by 73
Validation of a novel ultrasound measurement of achilles tendon length
Barfod, K. W., Riecke, A. F., Boesen, A., Hansen, P., Maier, J. F., Døssing, S., & Troelsen, A. (2014) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-014-3175-2 · Cited by 83
Validation of a New Portable Ergospirometric Device (Oxycon Mobile®) During Exercise
Perret, C., & Mueller, G. (2006) · International Journal of Sports Medicine · doi:10.1055/s-2005-865666 · Cited by 71
Distribution of radiographic osteoarthritis between the right and left hands, hips, and knees
Neame, R., Zhang, W., Deighton, C., Doherty, M., Doherty, S. A., Lanyon, P., & Wright, G. D. (2004) · Arthritis & Rheumatism · doi:10.1002/art.20162 · Cited by 71
Chan, J. H., Jenkins, C., Khafagi, F. A., Du, L., & Marwick, T. H. (2006) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.08.020 · Cited by 74
Effects of lateral ligament sectioning on the stability of the ankle and subtalar joint
Ringleb, S. I., Dhakal, A., Anderson, C. D., Bawab, S., & Paranjape, R. (2011) · Journal of Orthopaedic Research® · doi:10.1002/jor.21407 · Cited by 75
Sample size calculation for an agreement study
Liao, J. J. Z. (2010) · Pharmaceutical Statistics · doi:10.1002/pst.382 · Cited by 84
Xirouchakis, E., Marelli, L., Cholongitas, Ε., Manousou, P., Calvaruso, V., Pleguezuelo, M., Guerrini, G. P., Maimone, S., Kerry, A., Hajjawi, M. O. R., et al. (2010) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.03400410 · Cited by 71
Jokubkiene, L., Sladkevicius, P., Rovas, L., & Valentin, L. (2006) · Human Reproduction · doi:10.1093/humrep/del211 · Cited by 76
Self reported alcohol intake in pregnancy: comparison between four methods
Kesmodel, U., & Olsen, S. F. (2001) · Journal of Epidemiology and Community Health · doi:10.1136/jech.55.10.738 · Cited by 71
Williams, M. A., Williamson, E. M., Gates, S., & Cooke, M. W. (2011) · European Spine Journal · doi:10.1007/s00586-011-2096-8 · Cited by 71
Markl, M., Wallis, W., Strecker, C., Gladstone, B. P., Vach, W., & Harloff, A. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22856 · Cited by 84
Tsai, J., Chen, C.-J., Settu, K., Lin, Y.-F., Chen, C., & Liu, J.-T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.002 · Cited by 71
Whole blood versus plasma spots for measurement of HIV-1 viral load in HIV-infected African patients
Mwaba, P., Cassol, S. A., Nunn, A., Pilon, R., Chintu, C., Janes, M., & Zumla, A. I. (2003) · The Lancet · doi:10.1016/s0140-6736(03)15103-3 · Cited by 71
Setting Performance Goals and Evaluating Total Analytical Error for Diagnostic Assays
Krouwer, J. S. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.6.919 · Cited by 68
Onishi, T., Saha, S. K., Ludwig, D. R., Onishi, T., Marek, J. J., Cavalcante, J. L., Schelbert, E. B., SCHWARTZMAN, D. S., & Gorcsan, J. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-95 · Cited by 72
Sniff nasal inspiratory pressure in patients with chronic obstructive pulmonary disease
Uldry, C., Janssens, J.-P., de Muralt, B., & Fitting, J. W. (1997) · European Respiratory Journal · doi:10.1183/09031936.97.10061292 · Cited by 78
Arouca, M. A. F., Duarte, T. B., Lott, D. A. M., Magnani, P. S., Nogueira, A. A., Silva, J. C. R. E., & Brito, L. G. O. (2016) · International Urogynecology Journal · doi:10.1007/s00192-015-2938-8 · Cited by 88
Schierenbeck, F., Franco-Cereceda, A., & Liska, J. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816651632 · Cited by 71
Coronary CT Angiography: Variability of CT Scanners and Readers in Measurement of Plaque Volume
Symons, R., Morris, J. Z., Wu, C. O., Pourmorteza, A., Ahlman, M. A., Lima, J. A. C., Chen, M. Y., Mallek, M., Sandfort, V., & Bluemke, D. A. (2016) · Radiology · doi:10.1148/radiol.2016161670 · Cited by 72
Masri, B. A., Day, B., Younger, A. S. E., & Jeyasurya, J. (2016) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-016-0173-5 · Cited by 71
Are early first trimester weights valid proxies for preconception weight?
Krukowski, R. A., West, D. S., DiCarlo, M., Shankar, K., Cleves, M. A., Saylors, M. E., & Andres, A. (2016) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-016-1159-6 · Cited by 74
Leligdowicz, A., Conroy, A. L., Hawkes, M., Zhong, K., Lebovic, G., Matthay, M. A., & Kain, K. C. (2017) · PLoS ONE · doi:10.1371/journal.pone.0175130 · Cited by 75
Notational analysis – a mathematical perspective.
Hughes, M. D. (2004) · International Journal of Performance Analysis in Sport · doi:10.1080/24748668.2004.11868308 · Cited by 71
Association of a Low-Protein Diet With Slower Progression of CKD
Metzger, M., Yuan, W. L., Haymann, J., Flamant, M., Houillier, P., Thervet, É., Boffa, J., Vrtovsnik, F., Froissart, M., Bankir, L., et al. (2017) · Kidney International Reports · doi:10.1016/j.ekir.2017.08.010 · Cited by 79
Pfau, M., Lindner, M., Goerdt, L., Thiele, S., Nadal, J., Schmid, M. C., Schmitz-Valckenberg, S., Sadda, S. R., Holz, F. G., Fleckenstein, M., et al. (2018) · Retina · doi:10.1097/iae.0000000000002206 · Cited by 74
Jain, R., Duval, S., & Adabağ, S. (2014) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.113.000329 · Cited by 75
Agreement Between Pentacam and Videokeratography in Corneal Power Assessment
Savini, G., Barboni, P., Carbonelli, M., & Hoffer, K. J. (2009) · Journal of Refractive Surgery · doi:10.3928/1081597x-20090512-07 · Cited by 71
Rietzschel, E., Boeykens, E., Buyzere, M. D., Duprez, D. A., & Clement, D. L. (2001) · Hypertension · doi:10.1161/01.hyp.37.6.e15 · Cited by 84
Prepuncture Ultrasound-Measured Distance
Kil, H. K., Cho, J. H., Kim, W., Koo, B., Han, S. W., & Kim, J. (2007) · Regional Anesthesia & Pain Medicine · doi:10.1016/j.rapm.2006.10.005 · Cited by 71
Slinde, F., Ellegård, L., Grönberg, A., Larsson, S., & Rossander-Hulthén, L. (2003) · Clinical Nutrition · doi:10.1054/clnu.2002.0618 · Cited by 75
Peripheral Oxygenation and Anemia in Preterm Babies
Wardle, S. P., YOXALL, C. W., Crawley, E. M., & Weindling, A. M. (1998) · Pediatric Research · doi:10.1203/00006450-199807000-00020 · Cited by 71
RENAL FUNCTION BEFORE AND LONG AFTER LIVER TRANSPLANTATION IN CHILDREN1
Berg, U., Ericzon, B.-G. R., & Németh, A. (2001) · Transplantation · doi:10.1097/00007890-200108270-00012 · Cited by 71
Estimation of glomerular filtration rate in dogs with 99M-Tc-DTPA and iohexol
Moe, L., & Heiene, R. (1995) · Research in Veterinary Science · doi:10.1016/0034-5288(95)90067-5 · Cited by 78
Clinical and Technical Factors Affecting pH and Other Biomarkers in Exhaled Breath Condensate
Leung, T. F., Li, C., Yung, E. C.-M., Liu, E. K. H., Lam, C. W. K., & Wong, G. (2005) · Pediatric Pulmonology · doi:10.1002/ppul.20296 · Cited by 74
Is the Arte ACC Index a Valid Indicator of Free‐Living Physical Activity in Adolescents?
Ekelund, U., Åman, J., & Westerterp, K. (2003) · Obesity Research · doi:10.1038/oby.2003.110 · Cited by 70
Grybäck, P., Hermansson, G., Lyrenäs, E., Beckman, K.-W., Jacobsson, H., & Hellström, P. M. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050558 · Cited by 71
Calcium intakes among Australian women: Geelong Osteoporosis Study
Pasco, J. A., Sanders, K. M., Henry, M. J., Nicholson, G. C., Seeman, E., & Kotowicz, M. A. (2000) · Australian and New Zealand Journal of Medicine · doi:10.1111/j.1445-5994.2000.tb01049.x · Cited by 72
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.