STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 7,601–7,700 of 47,868
Lower Limb Kinematics of Subjects with Chronic Achilles Tendon Injury During Running
Donoghue, O. A., Harrison, A. J., Laxton, P., & Jones, R. K. (2008) · Research in Sports Medicine · doi:10.1080/15438620701693231 · Cited by 63
Measurement properties of the Wheelchair Skills Test – Questionnaire for powered wheelchair users
Rushton, P. W., Kirby, R. L., Routhier, F., & Smith, C. (2014) · Disability and Rehabilitation Assistive Technology · doi:10.3109/17483107.2014.984778 · Cited by 71
Assessment of test–retest reliability of animal-based measures on growing pig farms
Temple, D., Manteca, X., Dalmau, A., & Velarde, A. (2012) · Livestock Science · doi:10.1016/j.livsci.2012.10.012 · Cited by 63
Thomas, E. L., Collins, A. L., McCarthy, J. P., Fitzpatrick, J. A., Durighel, G., Goldstone, A. P., & Bell, J. D. (2010) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2010.18 · Cited by 64
Nogami, M., Ohno, Y., Koyama, H., Kono, A. K., Takenaka, D., Kataoka, T., Kawai, H., Kawamitsu, H., Onishi, Y., Matsumoto, K., et al. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21935 · Cited by 63
Bourges, J., Alfonsi, N., Laliberté, J.-F., Chagnon, M., Renard, G. J., Legeais, J., & Brunette, I. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.04.036 · Cited by 63
Dellacà, R. L., Ventura, M. L., Zannin, E., Natile, M., Pedotti, A., & Tagliabue, P. E. (2009) · Pediatric Research · doi:10.1203/pdr.0b013e3181c0b184 · Cited by 63
Becker, M., Moritz, A., & Giger, U. (2008) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2008.00085.x · Cited by 63
Shammas, J. H., & Chan, S. (2010) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2010.02.027 · Cited by 63
Adaptation of heart rate and blood pressure to short and long duration space missions
Verheyden, B., Liu, J., Beckers, F., & AUBERT, A. E. (2009) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2009.03.008 · Cited by 66
Sugiura, T., Fueki, K., & Igarashi, Y. (2008) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2008.01917.x · Cited by 63
The diurnal variation of matrix metalloproteinase-9 and its associated factors in human tears.
Markoulli, M., Papas, E., Cole, N., & Holden, B. (2012) · Investigative Ophthalmology and Visual Science · doi:10.1167/iovs.11-8365 · Cited by 66
Wilcox, J. J., Snow, B. J., Aoki, S. K., Hung, M., & Burks, R. T. (2012) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-012-2269-8 · Cited by 69
Short communication: Decrease in rumination time as an indicator of the onset of calving
Büchel, S., & Sundrum, A. (2014) · Journal of Dairy Science · doi:10.3168/jds.2013-7613 · Cited by 64
Böttiger, B. W., Soder, M., Rauch, H., Bohrer, H., Motsch, J., Bauer, H., & Martin, E. (1996) · Intensive Care Medicine · doi:10.1007/bf01700452 · Cited by 63
Montalbán, R., Pinero, D. P., Javaloy, J., & ALIO, J. L. (2012) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2011.12.029 · Cited by 63
Taddio, A., O’Brien, L., Ipp, M., Stephens, D., Goldbach, M., & Koren, G. (2009) · Pain · doi:10.1016/j.pain.2009.08.027 · Cited by 63
Limited validity of parental recall on pregnancy, birth, and early childhood at child age 10 years
Jaspers, M., de Meer, G., Verhulst, F. C., Ormel, J., & Reijneveld, S. A. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.05.003 · Cited by 70
Characterization of Atrial Septal Defect Assessed by Real-time 3-Dimensional Echocardiography
van den Bosch, A. E., Harkel, D. J. T., McGhie, J. S., Roos‐Hesselink, J. W., Simoons, M. L., Bogers, A. J. J. C., & Meijboom, F. J. (2006) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2006.01.016 · Cited by 63
Quantitative analysis of temporal lobe white matter T2 relaxation time in temporal lobe epilepsy
Townsend, T. N., Bernasconi, N., Pike, G. B., & Bernasconi, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.06.009 · Cited by 63
Bower, K. J., McGinley, J. L., Miller, K. J., & Clark, R. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115282 · Cited by 78
Reproducibility of endurance capacity and V̇o2peak in male Sprague-Dawley rats
Copp, S. W., Davis, R. T., Poole, D. C., & Musch, T. I. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.91566.2008 · Cited by 63
Foot Function After Fusion of the First Metatarsophalangeal Joint
van Doeselaar, D. J., Heesterbeek, P. J. C., Louwerens, J. W. K., & Swierstra, B. A. (2010) · Foot & Ankle International · doi:10.3113/fai.2010.0670 · Cited by 63
Saad, A., Crane, J. A., Glockner, J. F., Herrmann, S. M., Friedman, H. L., Ebrahimi, B., Lerman, L. O., & Textor, S. C. (2013) · Radiology · doi:10.1148/radiol.13122234 · Cited by 65
Zhu, Y. H., Papademetris, X., Sinusas, A. J., & Duncan, J. S. (2010) · Medical Image Analysis · doi:10.1016/j.media.2010.02.005 · Cited by 68
Liu, X., Wang, F., Xiao, Y. Y., Ye, X., & Hou, L. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.11-7752 · Cited by 63
Is There a Standard Trochanteric Entry Site for Nailing of Subtrochanteric Femur Fractures?
Streubel, P. N., Wong, A. H.-W., Ricci, W. M., & Gardner, M. J. (2011) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0b013e3181e93ce2 · Cited by 63
Misclassification of OSA Severity With Automated Scoring of Home Sleep Recordings
Aurora, R. N., Swartz, R., & Punjabi, N. M. (2014) · CHEST Journal · doi:10.1378/chest.14-0929 · Cited by 70
Accuracy and Reproducibility of Cap Thickness in Small Incision Lenticule Extraction
Reinstein, D. Z., Archer, T. J., & Gobbé, M. (2013) · Journal of Refractive Surgery · doi:10.3928/1081597x-20131023-02 · Cited by 63
Rodríguez-Granillo, G. A., Vaina, S., García‐García, H. M., Valgimigli, M., Duckers, E., van Geuns, R., Regar, E. S., van der Giessen, W. J., Bressers, M., Goedhart, D. M., et al. (2006) · International journal of cardiac imaging · doi:10.1007/s10554-006-9080-0 · Cited by 64
Diminished ciliary muscle movement on accommodation in myopia
Jeon, S., Lee, W. K., Lee, K., & Moon, N. J. (2012) · Experimental Eye Research · doi:10.1016/j.exer.2012.08.014 · Cited by 63
Hollis, A. R., Schaer, B. L. D., Boston, R. C., & Wilkins, P. A. (2008) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2008.0148.x · Cited by 63
Urea space and total body water measurements by stable isotopes in patients with acute renal failure
Ikizler, T. A., Sezer, M. T., Flakoll, P. J., Hariachar, S., Kanagasundaram, N. S., Gritter, N., Knights, S., Shyr, Y., Paganini, E., Hakim, R. M., et al. (2004) · Kidney International · doi:10.1111/j.1523-1755.2004.00439.x · Cited by 63
Aamot, I., Forbord, S. H., Karlsen, T., & Støylen, A. (2013) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2013.07.019 · Cited by 80
Modelling DW-MRI data from primary and metastatic ovarian tumours
Winfield, J. M., deSouza, N. M., Priest, A. N., Wakefield, J. C., Hodgkin, C., Freeman, S. J., Orton, M. R., & Collins, D. J. (2015) · European Radiology · doi:10.1007/s00330-014-3573-3 · Cited by 63
Disability Glare in the Aging Eye. Assessment and Impact on Driving☆
Berg, T., van Rijn, L. J., Kaper, R., Vonhoff, D. J., Völker-Dieben, H. J. M., Grabner, G., Nischler, C., Emesz, M., Wilhelm, H., & Gamer, D. (2009) · Journal of Optometry · doi:10.3921/joptom.2009.112 · Cited by 66
Seo, M.-K., Koo, B., Kim, J. H., Shin, D., Yang, H., Park, K. W., Lee, H., Kang, H., Kim, H.-S., Oh, B., et al. (2012) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.111.965392 · Cited by 63
Adam, I., Ahmed, S., Mahmoud, M. H., & Yassin, M. I. (2012) · Diagnostic Pathology · doi:10.1186/1746-1596-7-30 · Cited by 71
Kuznetsova, T., Cauwenberghs, N., Knez, J., Thijs, L., Liu, Y.-P., Gu, Y., & Staessen, J. A. (2014) · American Journal of Hypertension · doi:10.1093/ajh/hpu185 · Cited by 72
Reproducibility and Validity of a Handheld Spirometer
Barr, R. G., Stemple, K. J., Mesía-Vela, S., Basner, R. C., Derk, S. J., Henneberger, P. K., Milton, D. K., & Taveras, B. (2008) · Respiratory Care · doi:10.4187/respcare.08530433 · Cited by 66
Lymphatic Mapping in Patients with Breast Carcinoma: Reproducibility of Lymphoscintigraphic Results
Tanis, P. J., Olmos, R. A. V., Muller, S. H., & Nieweg, O. E. (2003) · Radiology · doi:10.1148/radiol.2282020651 · Cited by 63
Jancey, J. M., Tye, M., McGann, S., Blackford, K., & Lee, A. H. (2014) · BMC Public Health · doi:10.1186/1471-2458-14-762 · Cited by 73
Tomaske, M., Knirsch, W., Kretschmar, O., Woitzek, K., Balmer, C., Schmitz, A., Bauersfeld, U., & Weiß, M. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen024 · Cited by 63
Reproducibility of 31P cardiac magnetic resonance spectroscopy at 3 T
Tyler, D. J., Emmanuel, Y., Cochlin, L. E., Hudsmith, L., Holloway, C. J., Neubauer, S., Clarke, K., & Robson, M. D. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1350 · Cited by 80
Schou, S., Holmstrup, P., Jørgensen, T., Stoltze, K., Hjørting-Hansen, E., & Wenzel, A. (2003) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2003.120909.x · Cited by 73
DeBuc, D. C., Somfai, G. M., Ranganathan, S., Tátrai, E., Ferencz, M., & Puliafito, C. A. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3268773 · Cited by 63
Validación de una versión española del Índice de Discapacidad Cervical
Ortega, J. A. A., Delgado-Martínez, A. D., & Ruiz, R. (2008) · Medicina Clínica · doi:10.1157/13115352 · Cited by 119
Oesophageal Doppler monitoring overestimates cardiac output during lumbar epidural anaesthesia
Leather, H. A., & Wouters, P. F. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/86.6.794 · Cited by 63
Suehiro, K., Tanaka, K., Funao, T., Matsuura, T., Mori, T., & Nishikawa, K. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aet022 · Cited by 67
Jassar, A. S., Brinster, C. J., Vergnat, M., Robb, J. D., Eperjesi, T. J., Pouch, A. M., Cheung, A. T., Weiss, S. J., Acker, M. A., Gorman, J. H., et al. (2010) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2010.10.034 · Cited by 63
Pierangeli, S. S., Favaloro, E. J., Lakos, G., Meroni, P. L., Tincani, A., Wong, R. C. W., & Harris, E. N. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2011.09.048 · Cited by 63
Lowry, D. W., & Tomiyama, A. J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0115086 · Cited by 63
Mattos, C. T., Cruz, C. V., Matta, T. D., Pereira, L. D. A., Solon-de-Mello, P. D. A., Ruellas, A. C. D. O., & Sant’Anna, E. F. (2014) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2013.10.013 · Cited by 63
Perera, R., McFadden, E., McLellan, J., Lung, T., Clarke, P., Pérez, T., Fanshawe, T., Dalton, A., Farmer, A., Glasziou, P., et al. (2015) · Health Technology Assessment · doi:10.3310/hta191000 · Cited by 62
Comparison of five body-composition methods in peritoneal dialysis patients
Stall, S., Ginsberg, N., DeVita, M. V., Pm, Z., Lynn, R., Gleim, G. W., Wang, J., Pierson, R., & Michelis, M. F. (1996) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.2.125 · Cited by 65
Measuring Corneal Haze by Using Scheimpflug Photography and Confocal Microscopy
McLaren, J. W., Wacker, K., Kane, K. M., & Patel, S. V. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.15-17657 · Cited by 63
Albar, S. A., Alwan, N. A., Evans, C. E. L., Greenwood, D. C., & Cade, J. E. (2016) · British Journal of Nutrition · doi:10.1017/s0007114516000593 · Cited by 64
Assessing Shortened Field-Based Heart-Rate-Variability-Data Acquisition in Team-Sport Athletes
Pereira, L. A., Flatt, A. A., Ramírez‐Campillo, R., Loturco, I., & Nakamura, F. Y. (2015) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2015-0038 · Cited by 69
Methods for Measuring Lung Volumes: Is There a Better One?
Tantucci, C., Bottone, D., Borghesi, A., Guerini, M., Quadri, F., & Pini, L. (2016) · Respiration · doi:10.1159/000444418 · Cited by 63
Baek, J., Doh, S. H., & Chung, S. K. (2015) · Cornea · doi:10.1097/ico.0000000000000575 · Cited by 63
Relationship between plasma and salivary melatonin and cortisol investigated by LC-MS/MS
van Faassen, M. H. J. R., Bischoff, R., & Kema, I. P. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0817 · Cited by 72
IGFBP3 Modulates Lung Tumorigenesis and Cell Growth through IGF1 Signaling
Wang, Y. A., Sun, Y., Palmer, J. D., Solomides, C., Huang, L., Shyr, Y., Dicker, A. P., & Lü, B. (2017) · Molecular Cancer Research · doi:10.1158/1541-7786.mcr-16-0390 · Cited by 69
van der Werf, A., Dekker, I. M., Meijerink, M. R., Wierdsma, N. J., de van der Schueren, M. A. E., & Langius, J. A. E. (2018) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12422 · Cited by 62
Ultrasound measures of tendon thickness: Intra-rater, Inter-rater and Inter-machine reliability
del Ba�o-Aledo, M., Martínez-Payá, J. J., Ríos-Díaz, J., Mejías-Suárez, S., Serrano-Carmona, S., & de Groot-Ferrando, A. (2017) · Muscles Ligaments and Tendons Journal · doi:10.11138/mltj/2017.7.1.192 · Cited by 68
Monrroy, H., Vargas, J. I., Glasinovic, E., Cândia, R., de Azúa, E. R., Gálvez, C., Rojas, C., Cabrera, N., Vidaurre, J., Álvarez, N., et al. (2017) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2017.10.005 · Cited by 71
Federau, C., Goubran, M., Rosenberg, J., Henderson, J. M., Halpern, C. H., Santini, V. E., Wintermark, M., Butts, K., & Ghanouni, P. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25878 · Cited by 69
Incidence and impact of implant subsidence after stand-alone lateral lumbar interbody fusion
Bocahut, N., Audureau, É., Poignard, A., Delambre, J., Queinnec, S., Flouzat–Lachaniette, C.-H., & Allain, J. (2017) · Orthopaedics & Traumatology Surgery & Research · doi:10.1016/j.otsr.2017.11.018 · Cited by 63
van Rijn, S. F., Zwerus, E. L., Koenraadt, K. L. M., Jacobs, W. C. H., van den Bekerom, M. P. J., & Eygendaal, D. E. (2018) · Shoulder & Elbow · doi:10.1177/1758573218774326 · Cited by 63
Sleep staging using nocturnal sound analysis
Dafna, E., Tarasiuk, A., & Zigel, Y. (2018) · Scientific Reports · doi:10.1038/s41598-018-31748-0 · Cited by 69
Infant nocturnal wakefulness: a longitudinal study comparing three sleep assessment methods
Tikotzky, L., & Volkovich, E. (2018) · SLEEP · doi:10.1093/sleep/zsy191 · Cited by 71
Automated Cardiac Valve Tracking for Flow Quantification with Four-dimensional Flow MRI
Kamphuis, V. P., Roest, A. A. W., Marsan, N. A., van den Boogaard, P. J., Kroft, L. J. M., Aben, J., Bax, J. J., Roos, A., Lamb, H. J., & Westenberg, J. J. M. (2018) · Radiology · doi:10.1148/radiol.2018180807 · Cited by 74
A novel machine learning unsupervised algorithm for sleep/wake identification using actigraphy
Li, X., Zhang, Y., Jiang, F., & Zhao, H. (2020) · Chronobiology International · doi:10.1080/07420528.2020.1754848 · Cited by 74
Jannetts, S., Schaeffler, F., Beck, J. M., & Cowen, S. (2019) · International Journal of Language & Communication Disorders · doi:10.1111/1460-6984.12457 · Cited by 73
Goodall, I. (2005) · Europe PMC (PubMed Central) · Cited by 63
Atomic Emission Method for Total Boron in Blood during Neutron-Capture Therapy
Laakso, J. T., Kulvik, M., Ruokonen, I., Vähätalo, J., Zilliacus, R., Färkkilä, M., & Kallio, M. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.10.1796 · Cited by 63
Patroniti, N. A., Bellani, G., Manfio, A., Maggioni, E., Giuffrida, A., Foti, G., & Pesenti, A. M. (2004) · Intensive Care Medicine · doi:10.1007/s00134-003-2109-0 · Cited by 63
Vasseljen, O., Holte, K., & Westgaard, R. H. (2001) · Ergonomics · doi:10.1080/00140130010008101 · Cited by 70
Doppler echocardiographic estimation of mitral valve area during changing hemodynamic conditions
Braverman, A. C., Thomas, J. D., & Lee, R. T. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90283-q · Cited by 63
Holm, C., Melcer, B., Hörbrand, F., von Donnersmarck, G. H., & Mühlbauer, W. D. (2001) · Burns · doi:10.1016/s0305-4179(00)00088-7 · Cited by 63
Shaw, K. L., SOUTHWOOD, T. R., & McDonagh, J. E. R. (2006) · Arthritis Care & Research · doi:10.1002/art.21834 · Cited by 67
Skin bilirubin measurement during phototherapy in preterm and term newborn infants
Zecca, E., Barone, G., Luca, D. D., Marra, R., Tiberi, E., & Romagnoli, C. (2009) · Early Human Development · doi:10.1016/j.earlhumdev.2009.05.010 · Cited by 67
Ritz, P., & Study, F. T. S. (2001) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/56.6.m344 · Cited by 65
Castriota-Scanderbeg, A., Sacco, M. C., Gialloreti, L. E., & Fraracci, L. (1998) · Skeletal Radiology · doi:10.1007/s002560050380 · Cited by 63
McLellan, S. A., Walsh, T. S., Burdess, A., & Lee, A. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1323-5 · Cited by 63
Bernard, Y. F., Meneveau, N. F., Vuillemenot, A., Magnin, D., Anguenot, T., Schiele, F., & Bassand, J. (1997) · Heart · doi:10.1136/hrt.78.1.68 · Cited by 63
Huch, R., Wildermuth, S., Cettuzzi, L., Rake, A., Seifert, B., Chaoui, R., & Marinček, B. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma24567 · Cited by 63
Defecographic Study of Rectal Evacuation in Constipated Patients and Control Subjects
Karlbom, U., Nilsson, S., Påhlman, L., & Graf, W. (1999) · Radiology · doi:10.1148/radiology.210.1.r99dc48103 · Cited by 63
Imaging of myocardial infarction: comparison of magnevist and gadophrin-3 in rabbits
Barkhausen, J., Ebert, W., Debatin, J. F., & Weinmann, H. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01777-1 · Cited by 63
Respiratory Function in Survivors of the United Kingdom Extracorporeal Membrane Oxygenation Trial
Beardsmore, C., Dundas, I., Poole, K., Enock, K., & Stocks, J. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.4.9811093 · Cited by 64
Mechanical properties of the common carotid artery in Williams syndrome
Aggoun, Y., Sidi, D., Levy, B. I., Lyonnet, S., Kachaner, J., & Bonnet, D. (2000) · Heart · doi:10.1136/heart.84.3.290 · Cited by 68
Schubert, A., Tetzlaff, J. E., Tan, M. T., Ryckman, V. J., & Mascha, E. J. (1999) · Anesthesiology · doi:10.1097/00000542-199907000-00037 · Cited by 63
Auleley, G.-R., Benbouazza, K., Spoorenberg, A. J. P. L., Collantes‐Estévez, E., Hajjaj-Hassouni, N., van der Heijde, D. M. F. M., & Dougados, M. (2002) · Arthritis Care & Research · doi:10.1002/art.10798 · Cited by 63
Brunetti, A., Postiglione, A., Tedeschi, E., Ciarmiello, A., Quarantelli, M., Covelli, E. M., Milan, G., Larobina, M., Soricelli, A., Sodano, A., et al. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(200003)11:3<279::aid-jmri6>3.0.co;2-0 · Cited by 31
VALIDITY AND REPRODUCIBILITY OF HAND-HELD DYNAMOMETRY IN CHILDREN AGED 4–11 YEARS
van den Beld, W. A., van der Sanden, G., Sengers, R. C. A., Verbeek, A. L. M., & Gabreëls, F. (2005) · Journal of Rehabilitation Medicine · doi:10.1080/16501970510044043 · Cited by 83
Hopkinson, J. M., Butte, N., Ellis, K., Wong, W. W., Puyau, M. R., & Smith, E. (1997) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/65.2.432 · Cited by 74
Reading performance with low vision aids: relationship with contrast sensitivity
Leat, S. J., & Woodhouse, J. M. (1993) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.1993.tb00420.x · Cited by 63
Ge, S., Warner, J. G., Abraham, T. P., Kon, N. D., Brooker, R. F., Nomeir, A. M., Fowle, K. M., Burgess, P., & Kitzman, D. W. (1998) · American Heart Journal · doi:10.1016/s0002-8703(98)70161-9 · Cited by 63
The TOF‐Guard neuromuscular transmission monitor
Loan, P. B., Paxton, L. D., Mirakhur, R. K., Connolly, F. M., & McCoy, E. P. (1995) · Anaesthesia · doi:10.1111/j.1365-2044.1995.tb06097.x · Cited by 63
Forced oscillations in the clinical setting in young children with neonatal lung disease
Udomittipong, K., Sly, P. D., Patterson, H. J., Gangell, C. L., Stick, S. M., & Hall, G. L. (2008) · European Respiratory Journal · doi:10.1183/09031936.00058107 · Cited by 63
Achiron, A., & Faibel, M. (2002) · PubMed Central · Cited by 74
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.