STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 7,301–7,400 of 47,868
Maffeis, C., Schultz, Y., Zaffanello, M., Piccoli, R., & Pinelli, L. (1994) · The Journal of Pediatrics · doi:10.1016/s0022-3476(94)70355-8 · Cited by 80
Function: Magnetic Resonance Real-Time Imaging for the Evaluation of Left Ventricular Function
Nagel, E. C., Schneider, U., Schalla, S. M., Ibrahim, T., Schnackenburg, B., Bornstedt, A., Klein, C., Lehmkuhl, H. B., & Fleck, E. (2000) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976640009148668 · Cited by 66
Accuracy of Blood Loss Measurement during Cesarean Delivery
Doctorvaladan, S., Jelks, A., Hsieh, E., Thurer, R., Zakowski, M., & Lagrew, D. (2017) · American Journal of Perinatology Reports · doi:10.1055/s-0037-1601382 · Cited by 65
Rush, E. C., Chandu, V, & Plank, L. D. (2006) · International Journal of Obesity · doi:10.1038/sj.ijo.0803230 · Cited by 64
Determination of Maximal Lactate Steady State in Healthy Adults: Can NIRS Help?
BELLOTTI, C., CALABRIA, E., CAPELLI, C., & POGLIAGHI, S. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182828ab2 · Cited by 65
Antunes, M. V., Raymundo, S., de Oliveira, V., Staudt, D. E., Gössling, G. C. D. L., Peteffi, G. P., Biazús, J. V., Cavalheiro, J. A. C., Tré‐Hardy, M., Capron, A., et al. (2014) · Talanta · doi:10.1016/j.talanta.2014.10.040 · Cited by 73
Cerebellar pathology in Friedreich's ataxia: Atrophied dentate nuclei with normal iron content
Solbach, K., Kraff, O., Minnerop, M., Beck, A., Schöls, L. J., Gizewski, E. R., Ladd, M. E., & Timmann, D. (2014) · NeuroImage Clinical · doi:10.1016/j.nicl.2014.08.018 · Cited by 66
Assessment of Children's Literacy via an Internet-Based Telehealth System
Waite, M., Theodoros, D., Russell, T. G., & Cahill, L. (2010) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2009.0161 · Cited by 68
Kim, S. Y., Lee, S. S., Park, B., Kim, N., Kim, J. K., Park, S. H., Byun, J. H., Song, K., Koo, J. ‐., Choi, E. K., et al. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23744 · Cited by 66
Xiong, J., Tan, W., Wen, J., Pan, J., Wang, Y., Zhang, J., & Geng, D. (2015) · European Radiology · doi:10.1007/s00330-015-4025-4 · Cited by 69
High-Throughput Optical Sensing Immunoassays on Smartphone
Wang, L., Sun, R., Vasile, T., Chang, Y., & Li, L. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b02211 · Cited by 69
Heart Rate Variability During Exercise: A Comparison of Artefact Correction Methods
Giles, D., & Draper, N. (2017) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001800 · Cited by 78
Mann, S. J., & Gerber, L. M. (2019) · Journal of Clinical Hypertension · doi:10.1111/jch.13696 · Cited by 65
Coppey, F., Bécue, A., Sacré, P., Ziémons, E., Hubert, P., & Esseiva, P. (2020) · Forensic Science International · doi:10.1016/j.forsciint.2020.110498 · Cited by 68
The accuracy and reliability of WebCeph for cephalometric analysis
Yassir, Y. A., Salman, A. R., & Nabbat, S. A. (2021) · Journal of Taibah University Medical Sciences · doi:10.1016/j.jtumed.2021.08.010 · Cited by 65
Inconsistency of PCA-based water quality index – Does it reflect the quality?
Mahanty, B., Lhamo, P., & Sahoo, N. K. (2023) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2022.161353 · Cited by 65
Improving the reliability of measurements in orthopaedics and sports medicine
Królikowska, A., Reichert, P., Karlsson, J., Mouton, C., Becker, R., & Prill, R. (2023) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-023-07635-1 · Cited by 67
Reitblat, O., Assia, E. I., Kleinmann, G., Levy, A., Barrett, G. D., & Abulafia, A. (2014) · Clinical and Experimental Ophthalmology · doi:10.1111/ceo.12478 · Cited by 65
Kharbanda, A. B., Cosme, Y., Liu, K., Spitalnik, S. L., & Dayan, P. S. (2011) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2011.01095.x · Cited by 77
Timed Up and Go Test: A Reliable and Valid Test in Patients With Chronic Heart Failure
Hwang, R., Morris, N. R., Mandrusiak, A., Mudge, A., Suna, J. M., Adsett, J. A., & Russell, T. G. (2015) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2015.09.018 · Cited by 75
Cerrito, A., Bichsel, L., Radlinger, L., & Schmid, S. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.11.001 · Cited by 71
Hope, S. A., Meredith, I. T., Tay, D. B. H., & Cameron, J. D. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e328277595d · Cited by 68
Al‐Rawas, N., Banner, M. J., Euliano, N. R., Tams, C. G., Brown, J., Martin, A. D., & Gabrielli, A. (2013) · Critical Care · doi:10.1186/cc12500 · Cited by 73
Dabrh, A. M. A., Mohammed, K. S., Asi, N., Farah, W. H., Wang, Z., Farah, M. H., Prokop, L. J., Katznelson, L. J., & Murad, M. H. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2014-2900 · Cited by 65
Jakobsen, J. (2007) · Food Chemistry · doi:10.1016/j.foodchem.2007.06.008 · Cited by 65
Objective Assessment of the Corneal Endothelium in Fuchs' Endothelial Dystrophy
McLaren, J. W., Bachman, L. A., Kane, K. M., & Patel, S. V. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.13-13041 · Cited by 65
King, A. C., Woods, M., Liu, W., Lu, Z., Gill, D. S., & Krebs, M. R. H. (2011) · Protein Science · doi:10.1002/pro.680 · Cited by 70
Elizalde, J., Clemente, J., Marı́n, J. L., Panés, J., Aragón, B., Mas, A., Pique, J. M., & Terés, J. (1997) · Transfusion · doi:10.1046/j.1537-2995.1997.37697335150.x · Cited by 65
Ward, L. C., Czerniec, S. A., & Kilbreath, S. L. (2009) · Lymphatic Research and Biology · doi:10.1089/lrb.2008.1027 · Cited by 65
Hand length as an alternative measurement of height
Guerra, R. S., Fonseca, I. M., Pichel, F., Restivo, M. T., & do Amaral, T. F. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2013.220 · Cited by 65
Martinc, B., Roškar, R., Grabnar, I., & Vovk, T. (2014) · Journal of Chromatography B · doi:10.1016/j.jchromb.2014.05.030 · Cited by 65
Controlled Toothbrush Abrasion of Softened Human Enamel
Voronets, J., Jaeggi, T., Bürgin, W., & Lussi, A. (2008) · Caries Research · doi:10.1159/000148160 · Cited by 65
Quantitative Anatomy of Subaxial Cervical Lateral Mass
Stemper, B. D., Marawar, S. V., Yoganandan, N., Shender, B. S., & Rao, R. D. (2008) · Spine · doi:10.1097/brs.0b013e31816b4666 · Cited by 65
Comparison of Rebound Tonometer and Goldmann Handheld Applanation Tonometer in Congenital Glaucoma
Martínez-de-la-Casa, J. M., Garcia-Feijoo, J., Saenz-Frances, F., Vizzeri, G., Fernández-Vidal, A., Mendez-Hernandez, C. D., & Garcia-Sanchez, J. (2009) · Journal of Glaucoma · doi:10.1097/ijg.0b013e31816f760c · Cited by 65
Reliability of the MMSE Administered In-Person and by Telehealth
McEachern, W., Kirk, A., Morgan, D. G., Crossley, M., & Henry, C. (2008) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100009458 · Cited by 63
Modeling individual leaf area of ginger (Zingiber officinale Roscoe) using leaf length and width
Kandiannan, K., Parthasarathy, U., Krishnamurthy, K. S., Thankamani, C. K., & Srinivasan, V. (2009) · Scientia Horticulturae · doi:10.1016/j.scienta.2008.11.037 · Cited by 65
Hambye, A., Vervaet, A. M., & Dobbeleir, A. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-004-1601-2 · Cited by 65
Reliability of drop size from multi-dose eye drop bottles: is it cause for concern?
German, E. J., Hurst, M., & Wood, D. (1999) · Eye · doi:10.1038/eye.1999.17 · Cited by 65
Gagnon, D. H., Nadeau, S. M., Gravel, D., Robert, J., Bélanger, D., & Hilsenrath, M. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2005.04.013 · Cited by 65
Cone Photoreceptor Packing Density and the Outer Nuclear Layer Thickness in Healthy Subjects
Chui, T. Y. P., Song, H., Clark, C. A., Papay, J. A., Burns, S. A., & Elsner, A. E. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.11-8694 · Cited by 72
Kirsch, S. H., Knapp, J.-P., Herrmann, W., & Obeid, R. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.11.021 · Cited by 65
Temperature Curve Complexity Predicts Survival in Critically Ill Patients
Varela, M., Churruca, J., Gonzalez, A., Martin, A., Ode, J., & Galdos, P. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200601-058oc · Cited by 66
Three counting methods agree on cell and neuron number in chimpanzee primary visual cortex
Miller, D. J., Balaram, P., Young, N. A., & Kaas, J. H. (2014) · Frontiers in Neuroanatomy · doi:10.3389/fnana.2014.00036 · Cited by 66
Modified iodine-paper technique for the standardized determination of sweat gland activation
Gagnon, D., Ganio, M. S., Lucas, R. A. I., Pearson, J., Crandall, C. G., & Kenny, G. P. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01508.2011 · Cited by 65
3 T Contrast-Enhanced Magnetic Resonance Angiography for Evaluation of the Intracranial Arteries
Villablanca, J. P., Nael, K., Habibi, R., Nael, A., Laub, G. A., & Finn, J. P. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000242835.00032.f5 · Cited by 65
Peripheral arterial tonometry, oximetry and actigraphy for ambulatory recording of sleep apnea
Penzel, T., Kesper, K., Pinnow, I., Becker, H. F., & Vogelmeier, C. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/019 · Cited by 66
Arterial spin labeling measurement of cerebral perfusion in children with sickle cell disease
Gevers, S., Nederveen, A. J., Fijnvandraat, K., van den Berg, S. M., van Ooij, P., Heijtel, D. F., Heijboer, H., Nederkoorn, P. J., Engelen, M., van Osch, M. J., et al. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23505 · Cited by 65
Intrarater and Interrater Reliabilitiesfor a Toe Grip Dynamometer
Uritani, D., Fukumoto, T., & Matsumoto, D. (2012) · Journal of Physical Therapy Science · doi:10.1589/jpts.24.639 · Cited by 65
Barbosa, D., Dietenbeck, T., Heyde, B., Houle, H., Friboulet, D. P., D’hooge, J., & Bernard, O. (2012) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.08.008 · Cited by 65
Keevil, B. G., Lockhart, S. J., & Cooper, D. P. (2003) · Journal of Chromatography B · doi:10.1016/s1570-0232(03)00492-6 · Cited by 65
Youn, H., Rokosh, G. D., Lester, S. J., Simpson, P. C., Schiller, N. B., & Foster, E. (1999) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(99)70175-6 · Cited by 65
Tanimoto, S., Rodríguez-Granillo, G. A., Barlis, P., de Winter, S., Bruining, N., Hamers, R., Knappen, M., Verheye, S., Serruys, P. W. J. C., & Regar, E. S. (2008) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.21482 · Cited by 65
Stapelfeldt, B., Mornieux, G., Oberheim, R., Belli, A., & Gollhofer, A. (2007) · International Journal of Sports Medicine · doi:10.1055/s-2006-924352 · Cited by 65
Schüller, L. K., Burfeind, O., & Heuwieser, W. (2013) · Journal of Dairy Science · doi:10.3168/jds.2013-6736 · Cited by 87
Ajamil, D. L., Álvarez, L., Arana, J., Garzón, B., & Caballero, V. (2013) · Journal of Sports Sciences · doi:10.1080/02640414.2013.803584 · Cited by 65
RETINAL THICKNESS AND VOLUME MEASUREMENTS IN DIABETIC MACULAR EDEMA
Lammer, J., Scholda, C. D., Prünte, C. F., Benesch, T., Schmidt-Erfurth, U. M., & Bolz, M. (2010) · Retina · doi:10.1097/iae.0b013e3181e095a4 · Cited by 65
Validation of molecular-diagnostic techniques in the parasitological laboratory
Conraths, F. J., & Schares, G. (2006) · Veterinary Parasitology · doi:10.1016/j.vetpar.2005.12.004 · Cited by 78
Martins, W. P., Barra, D. D. A., Gallarreta, F. M. P., Nastri, C. O., & Filho, F. M. (2009) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.6224 · Cited by 72
Development of a risk score to predict sudden death in patients with Chaga's heart disease
de Souza, A. C. J., Salles, G. F., Hasslocher‐Moreno, A. M., de Sousa, A. S., do Brasil, P. E. A. A., Saraiva, R. M., & Xavier, S. S. (2015) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.03.372 · Cited by 76
Comparison of radiographic and photographic measurement of mandibular asymmetry
Edler, R., Wertheim, D. F., & Greenhill, D. R. (2003) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1067/mod.2003.16 · Cited by 65
Shin, D. W., Cho, J., Kim, S. Y., Chung, I. J., Kim, S. S., Yang, H. K., Ahn, E., Park, B. R., Seo, H., & Park, J. H. (2014) · Psycho-Oncology · doi:10.1002/pon.3631 · Cited by 65
A photonic crystal biosensor assay for ferritin utilizing iron-oxide nanoparticles
Peterson, R., Cunningham, B. T., & Andrade, J. E. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.01.022 · Cited by 67
Ramiro, S., van Tubergen, A. M., Stolwijk, C., Landewé, R., den Bosch, F. E. V., Dougados, M., & van der Heijde, D. M. F. M. (2013) · Arthritis Research & Therapy · doi:10.1186/ar4144 · Cited by 65
Biais, M., Nouette‐Gaulain, K., Roullet, S., Quinart, A., Revel, P., & Sztark, F. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181ac6dac · Cited by 65
Alexopoulos, D., Moulias, A., Koutsogiannis, N., Xanthopoulou, I., Kakkavas, A., Mavronasiou, E., Davlouros, P., & Hahalis, G. (2013) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.113.000293 · Cited by 66
Kane, C. T., Diop‐Ndiaye, H., Diallo, S., Ndiaye, I., Wade, A. S., Diaw, P. A., Gaye‐Diallo, A., & Mboup, S. (2008) · Journal of Virological Methods · doi:10.1016/j.jviromet.2007.11.011 · Cited by 65
Ichikawa, J., Kodaka, M., Nishiyama, K., Hirasaki, Y., Ozaki, M., & Komori, M. (2014) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2013.10.010 · Cited by 65
Arias, P., Robles‐García, V., Espinosa, N., Corral-Bergantiños, Y., & Cudeiro-Blanco, J. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.04.001 · Cited by 80
Pepper, J., Golesworthy, T. J., Utley, M., Chan, J., Ganeshalingam, S., Lampérth, M. U., Mohiaddin, R. H., & Treasure, T. (2009) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1510/icvts.2009.220319 · Cited by 67
Donadio, C., Consani, C., Ardini, M., Bernabini, G., Caprio, F., Grassi, G., Lucchesi, A., & Nerucci, B. (2005) · Journal of Renal Nutrition · doi:10.1016/j.jrn.2005.04.001 · Cited by 77
Airlie, J., Baker, G. A., Smith, S. J., & Young, C. A. (2001) · Clinical Rehabilitation · doi:10.1191/026921501668362643 · Cited by 65
Validity and reliability of the Swaymeter device for measuring postural sway
Sturnieks, D. L., Arnold, R., & Lord, S. R. (2011) · BMC Geriatrics · doi:10.1186/1471-2318-11-63 · Cited by 82
Ringdal, K. G., Skaga, N. O., Hestnes, M., Steen, P. A., Røislien, J., Rehn, M., Røise, O., Krüger, A., & Lossius, H. M. (2012) · Injury · doi:10.1016/j.injury.2012.06.032 · Cited by 80
Kamdar, R., Frain, E., Warburton, F., Richmond, L., Mullan, V., Berriman, T., Thomas, G., Tenkorang, J., Dhinoja, M., Earley, M. J., et al. (2009) · EP Europace · doi:10.1093/europace/eup337 · Cited by 65
Impact of bronchiectasis and trapped air on quality of life and exacerbations in cystic fibrosis
Tepper, L. A., Utens, E. M. W. J., Caudri, D., Bos, A. C., Graniel, K., Duivenvoorden, H. J., van der Wiel, E., Quittner, A. L., & Tiddens, H. A. W. M. (2013) · European Respiratory Journal · doi:10.1183/09031936.00137612 · Cited by 71
Paulis, W. D., Horemans, H. L. D., Brouwer, B. S., & Stam, H. J. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.10.094 · Cited by 65
Comparability of methods for LDL subfraction determination: A systematic review
Chung, M., Lichtenstein, A. H., Ip, S., Lau, J., & Balk, E. M. (2008) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2008.12.011 · Cited by 65
Agreement between bicarbonate measured on arterial and venous blood gases
Kelly, A., McAlpine, R., & Kyle, E. (2004) · Emergency Medicine Australasia · doi:10.1111/j.1742-6723.2004.00642.x · Cited by 72
A descriptive-comparative study of performance characteristics in futsal players of different levels
Naser, N., & Ali, A. (2016) · Journal of Sports Sciences · doi:10.1080/02640414.2015.1134806 · Cited by 65
The spectrum of circadian blood pressure changes in type I diabetic patients
Lurbe, E., Redón, J., Pascual, J. M., Tacons, J., & Álvarez, V. (2001) · Journal of Hypertension · doi:10.1097/00004872-200108000-00010 · Cited by 65
3D Printed scaffolds with bactericidal activity aimed for bone tissue regeneration
Correia, T. R., Figueira, D. R., de Sá, K. D., Miguel, S. P., Fradique, R., Mendonça, A., & Correia, I. J. (2016) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2016.06.004 · Cited by 71
Physical Fitness Assessment Across the Disability Spectrum in Persons With Multiple Sclerosis
Pilutti, L. A., Sandroff, B. M., Klaren, R. E., Learmonth, Y. C., Platta, M. E., Hubbard, E. A., Stratton, M., & Motl, R. W. (2015) · Neurology Report · doi:10.1097/npt.0000000000000099 · Cited by 65
Terry, L., Cassels, N. K., Lu, K., Acton, J. H., Margrain, T. H., North, R. V., Fergusson, J., White, N., & Wood, A. (2016) · PLoS ONE · doi:10.1371/journal.pone.0162001 · Cited by 66
Genetic Screening of Anderson-Fabry Disease in Probands Referred From Multispecialty Clinics
Favalli, V., Disabella, E., Molinaro, M., Tagliani, M., Scarabotto, A., Serio, A., Grasso, M., Narula, N., Giorgianni, C., Caspani, C., et al. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.05.090 · Cited by 70
Brink, M., Schreckenberg, D., Vienneau, D., Cajochen, C., Wunderli, J. M., Probst-Hensch, N. M., & Röösli, M. (2016) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph13111163 · Cited by 65
Evaluation of a Chemiluminescent Immunoassay for Measurement of Equine Insulin
Carslake, H. B., Pinchbeck, G. L., & McGowan, C. M. (2017) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.14657 · Cited by 65
Quantifying Fundus Autofluorescence in Patients With Retinitis Pigmentosa
Schuerch, K., Woods, R. L., Lee, W., Duncker, T., Delori, F. C., Allikmets, R., Tsang, S. H., & Sparrow, J. R. (2017) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-21302 · Cited by 64
Quarrington, R. D., Jones, C. F., Tcherveniakov, P., Clark, J., Sandler, S., Lee, Y. C., Torabiardakani, S., Costi, J. J., & Freeman, B. J. C. (2017) · The Spine Journal · doi:10.1016/j.spinee.2017.07.175 · Cited by 65
Grillo, A., Parati, G., Rovina, M., Moretti, F., Salvi, L., Gao, L., Baldi, C., Sorropago, G., Faini, A., Millasseau, S., et al. (2017) · American Journal of Hypertension · doi:10.1093/ajh/hpx140 · Cited by 73
Arroyo‐Gallego, T., Ledesma‐Carbayo, M. J., Butterworth, I., Matarazzo, M., Montero‐Escribano, P., Puertas‐Martín, V., Gray, M. L., Giancardo, L., & Sánchez‐Ferro, Á. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.9462 · Cited by 65
DiBiase, A. T., Woodhouse, N. R., Papageorgiou, S. N., Johnson, N., Slipper, C., Grant, J., Alsaleh, M., Khaja, Y., & Cobourne, M. T. (2018) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2017.10.021 · Cited by 79
Iron promotes oxidative cell death caused by bisretinoids of retina
Ueda, K., Kim, H. J., Zhao, J., Song, Y., Dunaief, J. L., & Sparrow, J. R. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1722601115 · Cited by 68
Persson, S., Eriksson, R., Lowther, J. A., Ellström, P., & Simonsson, M. (2018) · International Journal of Food Microbiology · doi:10.1016/j.ijfoodmicro.2018.06.022 · Cited by 72
Predicting broiler gait scores from activity monitoring and flock data
van Hertem, T., Norton, T., Berckmans, D., & Vranken, E. (2018) · Biosystems Engineering · doi:10.1016/j.biosystemseng.2018.07.002 · Cited by 73
A Range-Based Secure Localization Algorithm for Wireless Sensor Networks
Liu, X., Su, S., Han, F., Liu, Y., & Pan, Z. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2877306 · Cited by 66
Assessment of Breathing Parameters Using an Inertial Measurement Unit (IMU)-Based System
Cesareo, A., Previtali, Y., Biffi, E., & Aliverti, A. (2018) · Sensors · doi:10.3390/s19010088 · Cited by 76
Bennett, D., Ogonda, L., Elliott, D., Humphreys, L., Lawlor, M., & Beverland, D. (2007) · The Journal of Arthroplasty · doi:10.1016/j.arth.2006.02.173 · Cited by 65
Schor, A. M., Pendleton, N., Pazouki, S., Smither, R. L., Morris, J., Lessan, K., Heerkens, E. H. J., Chandrachud, L. M., Carmichael, G., Adi, M. M., et al. (1998) · The Histochemical Journal · doi:10.1023/a:1003437619956 · Cited by 65
Wang, Z., Zhu, S., Wang, J., Pierson, R. N., & Heymsfield, S. B. (2003) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/77.1.76 · Cited by 79
Misuse of correlation and regression in three medical journals
Porter, A. M. W. (1999) · Journal of the Royal Society of Medicine · doi:10.1177/014107689909200306 · Cited by 65
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.