STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 8,001–8,100 of 47,868
on behalf of the ReSolve Investigators and the FSHD CTRN18, LoRusso, S. J., Johnson, N. E., McDermott, M., Eichinger, K. J., Butterfield, R. J., Carraro, E., Higgs, K., Lewis, L., Mul, K., et al. (2019) · BMC Neurology · doi:10.1186/s12883-019-1452-x · Cited by 62
Bouvet, L., Zieleskiewicz, L., Loubradou, E., Alain, A., Morel, J., Argaud, L., CHASSARD, D., Léone, M., Allaouchiche, B., & networks, T. A. C. C. (2019) · Anaesthesia · doi:10.1111/anae.14915 · Cited by 61
Reliability and validity of speech & pause measures during passage reading in ALS
Barnett, C., Green, J. R., Marzouqah, R., Stipancic, K. L., Berry, J. D., Korngut, L. W., Genge, A. L., Shoesmith, C. L., Briemberg, H., Abrahão, A., et al. (2019) · Amyotrophic Lateral Sclerosis and Frontotemporal Degeneration · doi:10.1080/21678421.2019.1697888 · Cited by 66
Cudejko, T., Button, K., & Al-Amri, M. (2022) · Scientific Reports · doi:10.1038/s41598-022-18845-x · Cited by 60
Bishop, C. J., Jarvis, P. T., Turner, A. N., & Balsalobre‐Fernández, C. (2022) · Journal of Human Kinetics · doi:10.2478/hukin-2022-0098 · Cited by 67
Romano, C., Schena, E., Formica, D., & Massaroni, C. (2022) · Biosensors · doi:10.3390/bios12100834 · Cited by 63
Fieseler, G., Molitor, T., Irlenbusch, L., Delank, K.-S., Laudner, K. G., Hermassi, S., & Schwesig, R. (2015) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-015-2331-6 · Cited by 60
Wagner, D. R., Cain, D. L., & Clark, N. W. (2016) · PLoS ONE · doi:10.1371/journal.pone.0153146 · Cited by 68
Honda, T., Chen, S., Kishimoto, H., Narazaki, K., & Kumagai, S. (2014) · BMC Public Health · doi:10.1186/1471-2458-14-1307 · Cited by 61
A rapid self-administered food frequency questionnaire for the evaluation of dietary protein intake
Morin, P., Herrmann, F. R., Ammann, P., Uebelhart, B., & Rizzoli, R. (2005) · Clinical Nutrition · doi:10.1016/j.clnu.2005.03.002 · Cited by 72
Concordance of Disease Progression in Bilateral Geographic Atrophy Due to AMD
Fleckenstein, M., Adrion, C., Schmitz-Valckenberg, S., Göbel, A. P., Bindewald-Wittich, A., Scholl, H. P. N., Mansmann, U., & Holz, F. G. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-3547 · Cited by 66
Jastrow, N., Antonelli, E., Robyr, R., Irion, O. P., & Boulvain, M. (2006) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.2718 · Cited by 60
Accuracy of endodontic working length determination using cone beam computed tomography
Connert, T., Hülber‐J, M., Godt, A., Löst, C., & ElAyouti, A. (2013) · International Endodontic Journal · doi:10.1111/iej.12206 · Cited by 66
Struffert, T., Deuerling‐Zheng, Y., Kloska, S. P., Engelhorn, T., Boese, J. M., Zellerhoff, M., Schwab, S., & Doerfler, A. (2010) · European Radiology · doi:10.1007/s00330-010-1957-6 · Cited by 60
Surgical accuracy in Le Fort I maxillary osteotomies
Ong, T. K., Banks, R. J., & Hildreth, A. J. (2001) · British Journal of Oral and Maxillofacial Surgery · doi:10.1054/bjom.2000.0577 · Cited by 60
Rapi, S., Bazzini, C., Tozzetti, C., Sbolci, V., & Modesti, P. A. (2008) · Translational research · doi:10.1016/j.trsl.2008.11.010 · Cited by 60
Taylor, O., Armfield, N. R., Dodrill, P., & Smith, A. C. (2014) · Journal of Telemedicine and Telecare · doi:10.1177/1357633x14552388 · Cited by 68
Use of reconstructed computed tomography for the assessment of joint spaces in the canine elbow
Gemmill, T. J., Hammond, G., Mellor, D. J., Sullivan, M., Bennett, D., & Carmichael, S. (2006) · Journal of Small Animal Practice · doi:10.1111/j.1748-5827.2006.00052.x · Cited by 60
Massaad, A., Assi, A., Skalli, W., & Ghanem, I. B. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.08.001 · Cited by 70
Influence of Tear Film and Contact Lens Osmolality on Ocular Comfort in Contact Lens Wear
Stahl, U. G., Willcox, M. D. P., Naduvilath, T. J., & Stapleton, F. J. (2009) · Optometry and Vision Science · doi:10.1097/opx.0b013e3181ae027b · Cited by 62
Phal, P. M., Brooks, D. M., & Wolfe, R. S. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.184.5.01841652 · Cited by 60
Comparison of the Temporal Artery and Rectal Thermometry in Children in the Emergency Department
Schuh, S., Komar, L., Stephens, D., Chu, L., Read, S., & Allen, U. (2004) · Pediatric Emergency Care · doi:10.1097/01.pec.0000144915.78124.26 · Cited by 60
Hart, S. L., Hodgkinson, S. C., Belcher, H. M. E., Hyman, C., & Cooley-Strickland, M. (2012) · Journal of Behavioral Medicine · doi:10.1007/s10865-012-9440-2 · Cited by 89
Hussain, H. K., Londy, F. J., Francis, I. R., Nghiem, H. V., Weadock, W. J., Gebremariam, A., & Chenevert, T. L. (2003) · Radiology · doi:10.1148/radiol.2262011593 · Cited by 60
Comparison of the college alumnus questionnaire physical activity index with objective monitoring
Strath, S. J., Bassett, D. R., & Swartz, A. M. (2003) · Annals of Epidemiology · doi:10.1016/j.annepidem.2003.07.001 · Cited by 78
Andersen, L. F., Lande, B., Arsky, G. H., & Trygg, K. U. (2003) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601621 · Cited by 63
Intraocular Pressure Measurements Following Descemet Stripping Endothelial Keratoplasty
Vajaranant, T. S., Price, M. O., Price, F. W., Wilensky, J. T., & Edward, D. P. (2008) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2008.01.010 · Cited by 60
Wang, A. S., de Alencar, L. M., Weinreb, R. N., Tafreshi, A., Deokule, S. P., Vizzeri, G., & Medeiros, F. A. (2011) · Journal of Glaucoma · doi:10.1097/ijg.0b013e3182254ba3 · Cited by 60
Cervical Motion Assessment Using Virtual Reality
Bahat, H. S., Weiss, P. L., & Laufer, Y. (2009) · Spine · doi:10.1097/brs.0b013e31819b3254 · Cited by 60
Evaluation of the i‐STAT hand‐held chemical analyser during treadmill and endurance exercise
Silverman, S., & Birks, E. K. (2002) · Equine Veterinary Journal · doi:10.1111/j.2042-3306.2002.tb05481.x · Cited by 73
García‐Marcos, L., Valverde‐Molina, J., Sánchez‐Solís, M., Soriano-Pérez, M. J., Baeza-Alcaraz, A., Martinez-Torres, A. E., Pérez‐Fernández, V., & Guillén-Pérez, J.-J. (2005) · International Archives of Allergy and Immunology · doi:10.1159/000090389 · Cited by 62
Physiological Cost Index in Cerebral Palsy
Raja, K., Joseph, B., Benjamin, S., Minocha, V., & Rana, B. (2007) · Journal of Pediatric Orthopaedics · doi:10.1097/01.bpb.0000242440.96434.26 · Cited by 60
Hip flexibility is the main determinant of the back-saver sit-and-reach test in adolescents
Chillón, P., Castro-Piñero, J., Ruiz, J. R., Soto, V. M., Carbonell-Baeza, A., Dafos, J., Vicente-Rodríguez, G., Castillo, M. J., & Ortega, F. B. (2010) · Journal of Sports Sciences · doi:10.1080/02640411003606234 · Cited by 59
Inter-test reliability for non-invasive measures of respiratory muscle function in healthy humans
Romer, L. M., & MCCONNELL, A. K. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0984-2 · Cited by 66
Stuckey, D. J., Carr, C. A., Tyler, D. J., & Clarke, K. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1268 · Cited by 77
Shiran, A., Adawi, S., Ganaeem, M., & Asmer, E. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jen254 · Cited by 60
Davis, J. S., Yeo, T. W., Thomas, J. H., McMillan, M., Darcy, C. J., McNeil, Y., Cheng, A. C., Celermajer, D. S., Stephens, D. P., & Anstey, N. M. (2009) · Critical Care · doi:10.1186/cc8055 · Cited by 63
Durongpisitkul, K., Tang, N. L., Soongswang, J., Laohaprasitiporn, D., & Nanal, A. (2004) · Pediatric Cardiology · doi:10.1007/s00246-003-0481-8 · Cited by 60
Dyverfeldt, P., Ebbers, T., & Länne, T. (2014) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.08.021 · Cited by 66
Strecker, C., Harloff, A., Wallis, W., & Markl, M. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23735 · Cited by 60
Antoni, M. L., Bertini, M., Atary, J. Z., Delgado, V., ten Brinke, E. A., Boersma, E. H., Holman, E. R., van der Wall, E. E., Schalij, M. J., Bax, J. J., et al. (2010) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2010.02.030 · Cited by 60
Monsky, W. L., Kim, I., Loh, S., Li, C., Greasby, T. A., Deutsch, L., & Badawi, R. D. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.3964 · Cited by 65
Guiu, B., Loffroy, R., Petit, J., Aho, S., Salem, D. B., Masson, D., Hillon, P., Cercueil, J., & Krause, D. (2009) · European Radiology · doi:10.1007/s00330-009-1330-9 · Cited by 62
Early pregnancy volume measurements: validation of ultrasound techniques and new perspectives
Rousian, M., Verwoerd-Dikkeboom, C. M., Koning, A. H. J., Hop, W., van der Spek, P. J., Exalto, N., & Steegers, E. (2008) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2008.02006.x · Cited by 60
HRCT and MRI of the lung in children with cystic fibrosis: Comparison of different scoring systems
Siléo, C., Corvol, H., Boëlle, P., Blondiaux, É., Clément, A., & Pointe, H. D. L. (2013) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2013.09.003 · Cited by 68
Ostenfeld, E., Carlsson, M., Shahgaldi, K., Roijer, A., & Holm, J. (2012) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-10-1 · Cited by 63
Papadopoulou, S., García‐García, H. M., Rossi, A., Girasis, C., Dharampal, A. S., Kitslaar, P. H., Krestin, G. P., & de Feyter, P. J. (2012) · International journal of cardiac imaging · doi:10.1007/s10554-012-0167-5 · Cited by 68
Measurement of neural respiratory drive in patients with COPD
Luo, Y. M., & Moxham, J. (2005) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2004.12.014 · Cited by 64
Collins (2010) · Frontiers in Neuroanatomy · doi:10.3389/neuro.05.005.2010 · Cited by 61
Bertolotto, A., Sala, A., Caldano, M., Capobianco, M. A. N., Malucchi, S., Marnetto, F., & Gilli, F. (2007) · Journal of Immunological Methods · doi:10.1016/j.jim.2006.12.012 · Cited by 60
Efficacy of Instability Resistance Training
Cowley, P. J., Swensen, T., & Sforzo, G. A. (2007) · International Journal of Sports Medicine · doi:10.1055/s-2007-964893 · Cited by 61
Comparing measurement techniques of accommodative amplitudes
Momeni‐Moghaddam, H., Kundart, J., & Askarizadeh, F. (2014) · Indian Journal of Ophthalmology · doi:10.4103/0301-4738.126990 · Cited by 60
Reproducibility of brain ADC histograms
Steens, S. C. A., Behloul, F., Schaap, J. A., Hoogenraad, F. G. C., Wheeler‐Kingshott, C. A. M. G., le Cessie, S., Tofts, P. S., & van Buchem, M. A. (2003) · European Radiology · doi:10.1007/s00330-003-2121-3 · Cited by 60
Mok, É., Béghin, L., Gachon, P., Daubrosse, C., Fontan, J., Cuisset, J., Gottrand, F., & Hankard, R. (2006) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/83.1.65 · Cited by 63
Progressive Decline in Plethysmographic Lung Volumes in Infants
Hülskamp, G., Hoo, A., Ljungberg, H., Lum, S., Pillow, J. J., & Stocks, J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200303-460oc · Cited by 68
Saggiorato, E., Angusti, T., Rosas, R., Martinese, M., Finessi, M., Arecco, F., Trevisiol, E., Bergero, N., Puligheddu, B., Volante, M., et al. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.064980 · Cited by 69
Manns, P. J., & Haennel, R. G. (2012) · Stroke Research and Treatment · doi:10.1155/2012/247165 · Cited by 74
Bendjelid, K., Marx, G., Kiefer, N., Simon, T. P., Geisen, M., Hoeft, A., Siegenthaler, N., & Hofer, C. K. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aet116 · Cited by 60
van der Velde, J. L., Blok, B. M. J. F.-D., Vlieg‐Boerstra, B., Elberink, J. N. G. O., Schouten, J. P., DunnGalvin, A., Hourihane, J. O., Duiverman, E. J., & Dubois, A. E. J. (2009) · Quality of Life Research · doi:10.1007/s11136-008-9434-2 · Cited by 68
Post, M. W. M., Festen, H., van de Port, I. G. L., & Visser‐Meily, J. M. A. (2007) · Clinical Rehabilitation · doi:10.1177/0269215507079140 · Cited by 60
Wizner, B., Dechering, D. G., Thijs, L., Atkins, N., Fagard, R. H., O'Brien, E. T., de Leeuw, P. W., Parati, G., Palatini, P., Clement, D. L., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283013b59 · Cited by 64
Wee, H. L., Machin, D., Loke, W.-C., Li, S., Cheung, Y., Luo, N., Feeny, D. H., Fong, K., & Thumboo, J. (2007) · Value in Health · doi:10.1111/j.1524-4733.2007.00174.x · Cited by 63
Paredes, O. L., Shite, J., Shinke, T., Watanabe, S., Otake, H., Matsumoto, D., Imuro, Y., Ogasawara, D., Sawada, T., & Yokoyama, M. (2006) · Circulation Journal · doi:10.1253/circj.70.1164 · Cited by 60
Atrial Septal Defects in Pediatric Patients: Noninvasive Sizing with Cardiovascular MR Imaging
Beerbaum, P., Körperich, H., Esdorn, H., Blanz, U., Barth, P., Hartmann, J., Gieseke, J., & Meyer, H. (2003) · Radiology · doi:10.1148/radiol.2282020798 · Cited by 60
Willcox, N., Clarke, J., Smith, B. R., Deakin, A. H., & Deep, K. (2012) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.94b9.28250 · Cited by 60
Puig, J. G., Torres, R. J., de Miguel, E., Sánchez, A., Bailén, R., & Banegas, J. R. (2011) · Metabolism · doi:10.1016/j.metabol.2011.08.005 · Cited by 60
Reference values for the 6-Min Walking Test in obese subjects
Capodaglio, P., Souza, S. A. D., Parisio, C., Precilios, H., Vismara, L., Cimolin, V., & Brunani, A. (2012) · Disability and Rehabilitation · doi:10.3109/09638288.2012.726313 · Cited by 60
Habazettl, H., Athanasopoulos, D., Kuebler, W. M., Wagner, H., Roussos, C., Wagner, P. D., Ungruhe, J., Zakynthinos, S., & Vogiatzis, I. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01269.2009 · Cited by 62
Anthropometric approximation of body weight in unresponsive stroke patients
Lorenz, M., Graf, M., Henke, C., Hermans, M. P., Ziemann, U., Sitzer, M., & Foerch, C. (2007) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.2007.117150 · Cited by 67
Vera-Cala, L. M., Oróstegui, M., Valencia-Ángel, L. I., López, N., & Bautista, L. E. (2011) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2011005000038 · Cited by 32
Assessing Binocular Interaction in Amblyopia and Its Clinical Feasibility
Kwon, M., Lu, Z., Miller, A., Kazlas, M. A., Hunter, D. G., & Bex, P. J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0100156 · Cited by 61
Use of dried blood spots for the determination of plasma concentrations of nevirapine and efavirenz
Kromdijk, W., Mulder, J. W., Rosing, H., Smit, P. M., Beijnen, J. H., & Huitema, A. D. R. (2012) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dks011 · Cited by 60
Rapid T1 mapping of mouse myocardium with saturation recovery look‐locker method
Li, W., Griswold, M. A., & Yu, X. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22544 · Cited by 69
Barroso, G., Mercan, R., Özgür, K., Morshedi, M., Kolm, P., Coetzee, K., Kruger, T. F., & Oehninger, S. (1999) · Human Reproduction · doi:10.1093/humrep/14.8.2036 · Cited by 66
Justice at work and metabolic syndrome: the Whitehall II study
Gimeno, D., Tabák, Á. G., Ferrie, J. E., Shipley, M. J., Vogli, R. D., Elovainio, M. J., Vahtera, J., Marmot, M. G., & Kivimäki, M. (2009) · Occupational and Environmental Medicine · doi:10.1136/oem.2009.047324 · Cited by 67
Calkoen, E. E., Westenberg, J. J. M., Kroft, L. J. M., Blom, N. A., Hazekamp, M. G., Rijlaarsdam, M. E. B., Jongbloed, M. R. M., Roos, A., & Roest, A. A. W. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0122-4 · Cited by 69
Xinying, P. X., Noakes, M., & Keogh, J. B. (2004) · PubMed · Cited by 60
Ceffa, S., Luhanga, R., Andreotti, M., Brambilla, D., Erba, F., Jere, H., Mancinelli, S., Giuliano, M., Palombi, L., & Marazzi, M. C. (2015) · Journal of Virological Methods · doi:10.1016/j.jviromet.2015.12.007 · Cited by 60
Grouven, U., Bender, R., Ziegler, A., & Lange, S. (2007) · DMW - Deutsche Medizinische Wochenschrift · doi:10.1055/s-2007-959047 · Cited by 127
Koenig, N., Seeck, A., Eckstein, J., Mainka, A., Huebner, T., Voss, A., & Weber, S. (2016) · Telemedicine and e-Health · doi:10.1089/tmj.2015.0212 · Cited by 60
Geisler, C., Braun, W., Pourhassan, M., Schweitzer, L., Glüer, C., Bosy‐Westphal, A., & Müller, M. J. (2015) · The Journals of Gerontology Series A · doi:10.1093/gerona/glv211 · Cited by 72
Richman, J., Zangalli, C. E. S., Lŭ, L., Wizov, S. S., Spaeth, E., & Spaeth, G. L. (2014) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2014-305223 · Cited by 60
Immunoassay or LC-MS/MS for the measurement of salivary cortisol in children?
Bae, Y. J., Gaudl, A., Jaeger, S., Stadelmann, S., Hiemisch, A., Kiess, W., Willenberg, A., Schaab, M., von Klitzing, K., Thiery, J., et al. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0412 · Cited by 62
Pichon, R., Couturaud, F., Mialon, P., Ber-Moy, C. L., Péran, L., Lochon, C., Nowak, E., & Beaumont, M. (2016) · Respiration · doi:10.1159/000446517 · Cited by 62
Diaphragm assessment by two dimensional speckle tracking imaging in normal subjects
Orde, S. R., Boon, A. J., Firth, D. G., Villarraga, H. R., & Sekiguchi, H. (2015) · BMC Anesthesiology · doi:10.1186/s12871-016-0201-6 · Cited by 60
Shafique, U., Schulze, S. S., Slawik, C., Kunz, S., Paschke, A., & Schüürmann, G. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.10.026 · Cited by 70
Van Steen, S., Rijkenberg, S., Limpens, J., Van der Voort, P., Hermanides, J., & DeVries, J. (2017) · Sensors · doi:10.3390/s17010146 · Cited by 59
Mannil, M., Ramachandran, J., Martini, I. V. D., Wegener, S., Schmidt, B. T., Flohr, T. G., Krauß, B., Valavanis, A., Alkadhi, H., & Winklhofer, S. F.-X. (2017) · Investigative Radiology · doi:10.1097/rli.0000000000000391 · Cited by 61
Ahmad, F. S., Chan, C., Rosenman, M. B., Post, W. S., Fort, D. G., Greenland, P., Liu, K. J., Kho, A. N., & Allen, N. B. (2017) · Circulation · doi:10.1161/circulationaha.117.027436 · Cited by 60
Godwin, J. L., Vasudeva, R., Michalczyk, Ł., Martin, O. Y., Lumley, A. J., Chapman, T., & Gage, M. J. G. (2017) · Evolution Letters · doi:10.1002/evl3.13 · Cited by 60
Dietary Sources of High Sodium Intake in Turkey: SALTURK II
Erdem, Y., Akpolat, T., Derici, Ü., Şengül, Ş., Ertürk, Ş., Ulusoy, Ş., Altun, B., & Arıcı, M. (2017) · Nutrients · doi:10.3390/nu9090933 · Cited by 60
Copen, W. A., Yoo, A. J., Rost, N. S., Morais, L. T., Schaefer, P. W., González, R., & Wu, O. (2017) · PLoS ONE · doi:10.1371/journal.pone.0188891 · Cited by 65
Brunner, M., Romano, V., Steger, B., Vinciguerra, R., Lawman, S., Williams, B. M., Hicks, N., Czanner, G., Zheng, Y., Willoughby, C. E., et al. (2018) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.17-22035 · Cited by 60
Stone, M., Bainbridge, J., Sanchez, A. M., Keating, S. M., Pappas, A. L., Rountree, W., Todd, C., Bakkour, S., Manak, M., Peel, S. A., et al. (2018) · Journal of Clinical Microbiology · doi:10.1128/jcm.02045-17 · Cited by 64
Zoppino, F. C. M., Guerrero-Gimenez, M. E., Castro, G. N., & Ciocca, D. R. (2018) · BMC Cancer · doi:10.1186/s12885-018-4621-1 · Cited by 63
González‐Ruíz, K., Medrano, M., Correa‐Bautista, J. E., García‐Hermoso, A., Prieto‐Benavides, D. H., Tordecilla‐Sanders, A., Agostinis‐Sobrinho, C., Correa‐Rodríguez, M., Schmidt‐RioValle, J., González‐Jiménez, E., et al. (2018) · Nutrients · doi:10.3390/nu10081086 · Cited by 68
iPhone‐based Pupillometry: A Novel Approach for Assessing the Pupillary Light Reflex
McAnany, J. J., Smith, B. M., Garland, A., & Kagen, S. L. (2018) · Optometry and Vision Science · doi:10.1097/opx.0000000000001289 · Cited by 64
Salivary biomarkers of inflammation and oxidative stress in healthy adults
Nam, Y., Kim, Y., Chang, J., & Kho, H. (2018) · Archives of Oral Biology · doi:10.1016/j.archoralbio.2018.10.026 · Cited by 72
The Impact of Organizational Culture on Employee Engagement in Saudi Banks
Shehri, M. A., McLaughlin, P., Al-Ashaab, A., & Rashid, H. S. (2017) · Journal of Human Resources Management Research · doi:10.5171/2017.761672 · Cited by 68
Lansdown, D. A., Cvetanovich, G. L., Verma, N. N., Cole, B. J., Bach, B. R., Nicholson, G. P., Romeo, A. A., Dawe, R. J., & Yanke, A. B. (2019) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2018.10.119 · Cited by 66
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.