Inadequate suspension of neutral protamine Hagendorn (NPH) insulin in pens
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Turner, R. C., Fox, C., Matthews, McElroy, H. H., Cull, C. A., Holman, R. R., Neil, P., Hadden, D. R., Wright, D., Manley, E., et al. (1998) · The Lancet · Cited by 8,419
Reichard, P., Nilsson, B.-Y., & Rosenqvist, U. (1993) · New England Journal of Medicine · doi:10.1056/nejm199307293290502 · Cited by 1,202
Absorption Kinetics and Biologic Effects of Subcutaneously Injected Insulin Preparations
Berger, M., Cüppers, H. J., Hegner, H., Jörgens, V, & Berchtold, P. (1982) · Diabetes Care · doi:10.2337/diacare.5.2.77 · Cited by 252
Effect of patient-selected intensive insulin therapy on quality of life
Chantelau, E. A., Schiffers, T., Schütze, J., & Hansen, B. (1997) · Patient Education and Counseling · doi:10.1016/s0738-3991(96)00964-0 · Cited by 70
The Kinetics of Insulin Administration by Insulin Pens
Ginsberg, B., Parkes, J., & Sparacino, C. (1994) · Hormone and Metabolic Research · doi:10.1055/s-2007-1001764 · Cited by 54
A Randomized Trial of the Efficacy and Acceptability of a Pen Injector
Murray, D. P., Keenan, P., Gayer, E., Salmon, P., TOMKIN, G. H., Drury, M. I., & O’Sullivan, D. J. (1988) · Diabetic Medicine · doi:10.1111/j.1464-5491.1988.tb01102.x · Cited by 46
Jf, B., Nielsen, O. H., Pedersen, O. B., & Beck‐Nielsen, H. (1987) · PubMed · Cited by 32
Skyler, J. S. (1988) · Medical Clinics of North America · doi:10.1016/s0025-7125(16)30710-6 · Cited by 21
Cited by
Lepore, M., Pampanelli, S., Fanelli, C., Porcellati, F., Bartocci, L., Di Vincenzo, A., Cordoni, C., Costa, E., Brunetti, P., & Bolli, G. B. (2000) · Diabetes · doi:10.2337/diabetes.49.12.2142 · Cited by 818
“until complete suspension was obtained, as recently recommended (16).”
BackgroundHeise, T., Nosek, L., Rønn, B. B., Endahl, L., Heinemann, L., Kapitza, C., & Draeger, E. (2004) · Diabetes · doi:10.2337/diabetes.53.6.1614 · Cited by 614
Heinemann, L., Linkeschova, R., Rave, K., Hompesch, B., Sedlak, M., & Heise, T. (2000) · Diabetes Care · doi:10.2337/diacare.23.5.644 · Cited by 473
Owens, D. R., Zinman, B., & Bolli, G. B. (2001) · The Lancet · doi:10.1016/s0140-6736(01)05842-1 · Cited by 373
Hermansen, K., Fontaine, P., Kukolja, K. K., Peterkova, V., Leth, G., & Gall, M.-A. (2004) · Diabetologia · doi:10.1007/s00125-004-1365-z · Cited by 365
“ing precision with NPH insulin is often highly variable due to inadequate resuspension [6, 7].”
BackgroundVague, P., Selam, J.-L., Skeie, S., De Leeuw, I., Elte, J. W. F., Haahr, H., Kristensen, A., & Draeger, E. (2003) · Diabetes Care · doi:10.2337/diacare.26.3.590 · Cited by 294
New insulin delivery recommendations
Frid, A. H., Kreugel, G., Grassi, G., Halimi, S., Hicks, D., Hirsch, L. J., Smith, M. J., Wellhoener, R., Bode, B. W., Hirsch, I. B., et al. (2016) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2016.06.010 · Cited by 286
Haak, T., Tiengo, A., Draeger, E., Suntum, M., & Waldhäusl, W. (2005) · Diabetes, Obesity and Metabolism · doi:10.1111/j.1463-1326.2004.00373.x · Cited by 277
Variability of Insulin Absorption and Insulin Action
Heinemann, L. (2002) · Diabetes Technology & Therapeutics · doi:10.1089/152091502320798312 · Cited by 267
Heise, T., & Pieber, T. R. (2007) · Diabetes, Obesity and Metabolism · doi:10.1111/j.1463-1326.2007.00756.x · Cited by 239
“It is well established and widely accepted that basal human insulin preparations [Ultralente and neutral protamineHagedorn(NPH)insulin]fallshortofthesedesired properties [3,4]: they not only are suspensions that have to be thoroughly resuspended prior to injection, a requirement often ignored by many patients [ 5 ], b…”
BackgroundDanne, T., Phillip, M., Buckingham, B. A., Jarosz-Chobot, P., Saboo, B., Urakami, T., Battelino, T., Hanas, R., & Codner, E. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12718 · Cited by 225
Factors Affecting the Absorption of Subcutaneously Administered Insulin: Effect on Variability
Gradel, A. K. J., Porsgaard, T., Lykkesfeldt, J., Seested, T., Gram-Nielsen, S., Kristensen, N. R., & Refsgaard, H. H. F. (2018) · Journal of Diabetes Research · doi:10.1155/2018/1205121 · Cited by 202
“between injections [82, 141] It is recommended to gently roll and tip cloudy insulin until the crystals are resuspended (the solution becomes milk white)”
BackgroundInsulin detemir and insulin aspart: a promising basal-bolus regimen for type 2 diabetes
Rašlová, K., Bogoev, M., Raz, I., Leth, G., Gall, M.-A., & Hâncu, N. (2004) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2004.03.003 · Cited by 195
Russell-Jones, D., Simpson, R., Hylleberg, B., Draeger, E., & Bolinder, J. (2004) · Clinical Therapeutics · doi:10.1016/s0149-2918(04)90072-0 · Cited by 194
Bolli, G. B., & Owens, D. R. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02546-0 · Cited by 186
De Leeuw, I., Vague, P., Selam, J. ‐., Skeie, S., Lang, H., Draeger, E., & Elte, J. W. F. (2005) · Diabetes, Obesity and Metabolism · doi:10.1111/j.1463-1326.2004.00363.x · Cited by 179
Comparison of the Soluble Basal Insulin Analog Insulin Detemir With NPH Insulin
Hermansen, K., Madsbad, S., Perrild, H., Kristensen, A., & Axelsen, M. (2001) · Diabetes Care · doi:10.2337/diacare.24.2.296 · Cited by 174
New injection recommendations for patients with diabetes
Frid, A., Hirsch, L., Gaspar, R., Hicks, D., Kreugel, G., Liersch, J., Letondeur, C., Sauvanet, J. P., Tubiana-Rufi, N., & Strauss, K. (2010) · Diabetes & Metabolism · doi:10.1016/s1262-3636(10)70002-1 · Cited by 172
Recombinant DNA Technology in the Treatment of Diabetes: Insulin Analogs
Vajo, Z., Fawcett, J., & Duckworth, W. C. (2001) · Endocrine Reviews · doi:10.1210/edrv.22.5.0442 · Cited by 172
“The long-acting preparations of human insulin are mostly suspensions, which require shaking before use, adding another factor to variability as adequate mixing usually does not occur (89).”
BackgroundDanne, T., Lüpke, K., Walte, K., von Schuetz, W., & Gall, M.-A. (2003) · Diabetes Care · doi:10.2337/diacare.26.11.3087 · Cited by 153
“Moreover, the suspended formulas in which basal insulins are currently available require adequate agitation before use to ensure a homogenous mix, introducing user-dependent variability (7).”
BackgroundArnolds, S., Kuglin, B., Kapitza, C., & Heise, T. (2010) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2010.02470.x · Cited by 69
Cengiz, E., Danne, T., Ahmad, T., Ayyavoo, A., Beran, D., Codner, E., Ehtisham, S., Jarosz-Chobot, P., Mungai, L. N. W., Ng, S. M., et al. (2025) · Hormone Research in Paediatrics · doi:10.1159/000543169 · Cited by 17
“Insuf fi cient resuspension of NPH adds to the day-to-day variability of the glucose-lowering effect and is re fl ected by greater glycemic variability and hypoglycemia [35].”
Metadata
- Authors
- Jehle, P. M., Micheler, C., Jehle, D. R., Breitig, D., & Boehm, B. O.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1999-11
- Volume
- 354
- Issue
- 9190
- Pages
- 1604-1607
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2138112294
- Cited by
- 186
- References
- 12
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.