The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Parametric study and simplified design of tuned mass dampers
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“2-During time-history analysis, when damping is getting large, TMD performance is reducing.”
From Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review (2020) · cites this paper as Rana and Soong [64]
In the citing paper
“1-When damping and mass ratio is increasing, the effect of detuning in TMDs parameters becomes less detrimental”
From Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review (2020) · cites this paper as Rana and Soong [64]
Citations
Cites
Bishop, R. E. D. (1957) · Nature · doi:10.1038/179504a0 · Cited by 1,640
Optimum absorber parameters for various combinations of response and excitation parameters
Warburton, G. B. (1982) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290100304 · Cited by 1,059
The Theory of the Dynamic Vibration Absorber
Ormondroyd, J., & Den Hartog, J. P. (1928) · Transactions of the American Society of Mechanical Engineers · doi:10.1115/1.4058553 · Cited by 779
Optimum absorber parameters for simple systems
Warburton, G. B., & Ayorinde, E. O. (1980) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290080302 · Cited by 376
Yamaguchi, H., & Harnpornchai, N. (1993) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290220105 · Cited by 341
Dynamic characteristics of multiple substructures with closely spaced frequencies
Xu, K., & Igusa, T. (1992) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290211203 · Cited by 326
Performance of Multiple Mass Dampers under Random Loading
Kareem, A., & Kline, S. (1995) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1995)121:2(348) · Cited by 306
Tsai, H., & Lin, G. (1993) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290221104 · Cited by 279
Optimum Vibration Absorbers for Linear Damped Systems
Randall, S., Halsted, D. M., & Taylor, D. L. (1981) · Journal of Mechanical Design · doi:10.1115/1.3255005 · Cited by 182
On the Dynamic Vibration Damped Absorber of the Vibration System
Ioi, T., & Ikeda, K. (1978) · Bulletin of JSME · doi:10.1299/jsme1958.21.64 · Cited by 151
Research works printed but not linked: 2
- Bishop, 1952, The problem of the dynamic vibration absorber, Engineering, 174
- Bishop, 1952, The problem of the dynamic vibration absorber, Engineering, 769
Cited by
Sorted by citations
Assouar, B. M., Liang, B., Wu, Y., Li, Y., Cheng, J., & Jing, Y. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0061-4 · Cited by 958
Marian, L., & Giaralis, A. (2014) · Probabilistic Engineering Mechanics · doi:10.1016/j.probengmech.2014.03.007 · Cited by 828
Vibration serviceability of footbridges under human-induced excitation: a literature review
Živanović, S., Pavić, A., & Reynolds, P. (2004) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2004.01.019 · Cited by 631
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
Wind-Induced Vibration Mitigation in Tall Buildings Using the Tuned Mass-Damper-Inerter
Giaralis, A., & Petrini, F. (2017) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001863 · Cited by 330
Metadata
- Authors
- Rana, R., & Soong, T. T.
- Affiliations
- University at Buffalo, State University of New York (US)
- Venue
- Engineering Structures
- Publisher
- Elsevier BV
- Published
- 1998-03
- Volume
- 20
- Issue
- 3
- Pages
- 193-204
- ISSN
- 0141-0296 (ISSN-L)
- OpenAlex
- W2073786140
- Cited by
- 651
- References
- 15
- Citations by year
- 2026: 33 · 2025: 57 · 2024: 65 · 2023: 38 · 2022: 59 · 2021: 40 · 2020: 43 · 2019: 34 · 2018: 36 · 2017: 43 · 2016: 33 · 2015: 23 · 2014: 25 · 2013: 18 · 2012: 14
- FWCI
- 16.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Engineering Structures (publishedVersion)
- Topics
- Physical Sciences › Engineering › Civil and Structural Engineering › Vibration Control and Rheological Fluids
- Physical Sciences › Engineering › Civil and Structural Engineering › Structural Engineering and Vibration Analysis
- Physical Sciences › Engineering › Civil and Structural Engineering › Seismic Performance and Analysis
- Keywords
- tuned mass damper, detuning, single-degree-of-freedom systems, multi-degree-of-freedom systems, modal control, seismic response control, El Centro ground motion, time history analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›