Cell adhesion on gaseous plasma modified poly-(l-lactide) surface under shear stress field
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Martin, J. Y., Schwartz, Z., Hummert, T. W., Schraub, D. M., Simpson, J., Lankford, J., Dean, D. D., Cochran, D. L., & Boyan, B. D. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290314 · Cited by 1,111 · cited 1×
“It is commonly accepted that the adhesion of cells to solid substrata is influenced by several substratum surface properties, such as wettability [2,3], surface charge [4–6], roughness and topography [7].”
BackgroundBiodegradable poly(lactic acid) polymers
Kulkarni, R. K., Moore, E. G., Hegyeli, A. F., & Leonard, F. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050305 · Cited by 799 · cited 1×
“l-lactide was synthesized from l-lactic acid according to the literature method [24].”
MethodInteraction of cultured human endothelial cells with polymeric surfaces of different wettabilities
van Wachem, P. B., Beugeling, T., Feijen, J., Bantjes, A., Detmers, J. P., & van Aken, W. G. (1985) · Biomaterials · doi:10.1016/0142-9612(85)90101-2 · Cited by 591 · cited 1×
“It is known that substrata with high or intermediate hydrophilicity sustain optimal cell adhesion and spreading [26].”
BackgroundSynthesis and RGD peptide modification of a new biodegradable copolymer: poly(lactic acid-co-lysine)
Barrera, D. A., Zylstra, E., Lansbury, P. T., & Langer, R. (1993) · Journal of the American Chemical Society · doi:10.1021/ja00076a077 · Cited by 456 · cited 1×
“However, it has poor hydrophilicity and there are no natural recognition sites on the surface of poly-(l-lactic) (PLLA) [14].”
Backgroundvan Wachem, P. B., Hogt, A. H., Beugeling, T., Feijen, J., Bantjes, A., Detmers, J. P., & van Aken, W. G. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90001-9 · Cited by 372
Sakaríassen, K. S., Aarts, P. A. M. M., de Groot, P. G., Houdijk, W. P. M., & Sixma, J. J. (1983) · PubMed · Cited by 366
Resorbable materials of poly(l-lactide). VI. Plates and screws for internal fracture fixation
Leenslag, J. W., Pennings, A. J., Bos, R. R. M., Rozema, F. R., & Boering, G. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90034-2 · Cited by 295
Flat plate streaming potential investigations: Hydrodynamics and electrokinetic equivalency
Van Wagenen, R. A., & Andrade, J. D. (1980) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(80)90374-4 · Cited by 275
Influence of substratum wettability on the strength of adhesion of human fibroblasts
van Kooten, T. G., Schakenraad, J. M., van der Mei, H. C., & Busscher, H. J. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90112-2 · Cited by 193 · cited 1×
“The shear stress was calculated from the following equation [25]:”
MethodProtein adsorption at the interface between charged polymer substrata and migrating osteoblasts
Shelton, R. M., Rasmussen, A. C., & Davies, J. E. (1988) · Biomaterials · doi:10.1016/0142-9612(88)90065-8 · Cited by 155
Preparation and surface characterization of PEO-grafted and heparin-immobilized polyurethanes
Han, D. K., Park, K. D., Ahn, K., Jeong, S. Y., & Kim, Y. H. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820231309 · Cited by 143
van Kooten, T. G., Schakenraad, J. M., Van der Mei, H. C., & Busscher, H. J. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820260604 · Cited by 138 · cited 1×
“The interaction of treated film with mouse 3T3 fibroblast cells was quantitatively evaluated using a modified parallel plate flow chamber [22] according to previous work [23].”
MethodCell behaviour on polymer surfaces grafted with non-ionic and ionic monomers
Kishida, A., Iwata, H., Tamada, Y., & Ikada, Y. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90031-5 · Cited by 124 · cited 1×
“It is commonly accepted that the adhesion of cells to solid substrata is influenced by several substratum surface properties, such as wettability [2,3], surface charge [4–6], roughness and topography [7].”
BackgroundImproving cell affinity of poly( D,L ‐lactide) film modified by anhydrous ammonia plasma treatment
Yang, J. H., Bei, J., & Wang, S. (2002) · Polymers for Advanced Technologies · doi:10.1002/pat.177 · Cited by 113 · cited 3×
“Plasma treatment using nonpolymerizing gases can create reactive sites such as amine group [ 3 ,10] and carboxyl [11] on polymers (i.e.”
BackgroundMethodSelf-citationCell Interactions with Polymers
Saltzman, W. M., & Kyriakides, T. R. (2014) · Principles of Tissue Engineering · doi:10.1016/b978-0-12-398358-9.00020-3 · Cited by 102
An Apparatus to Study the Response of Cultured Endothelium to Shear Stress
Viggers, R. F., Wechezak, A. R., & Sauvage, L. R. (1986) · Journal of Biomechanical Engineering · doi:10.1115/1.3138624 · Cited by 73 · cited 1×
“The parallel plate flow chamber, frequently used by many researchers, can perform such a shear stress field [15–21].”
MethodEvaluation of blood compatibility of PEO grafted and heparin immobilized polyurethanes.
Han, D. K., Jeong, S. Y., & Kim, Y. H. (1989) · PubMed · Cited by 65
A Flow System for the Study of Shear Forces Upon Cultured Endothelial Cells
Koslow, A. R., Stromberg, R. R., Friedman, L. I., Lutz, R. J., Hilbert, S. L., & Schuster, P. (1986) · Journal of Biomechanical Engineering · doi:10.1115/1.3138625 · Cited by 47
Groth, T., Altankov, G., & Klosz, K. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90220-8 · Cited by 45 · cited 1×
“It is commonly accepted that the adhesion ofcells to solid substrata is influenced by several substratum surface properties, such as wettability [ 2 ,3], surface charge [4–6], roughness and topography [7].”
BackgroundStreaming potential in the hydrodynamic entrance region of cylindrical and rectangular capillaries
Bowen, B. D. (1985) · Journal of Colloid and Interface Science · doi:10.1016/s0021-9797(85)80011-4 · Cited by 33 · cited 1×
“The parallel plate flow chamber, frequently used by many researchers, can perform such a shear stress field [15–21].”
Method
Cited by
Recent Developments in Ring Opening Polymerization of Lactones for Biomedical Applications
Albertsson, A.-C., & Varma, I. K. (2003) · Biomacromolecules · doi:10.1021/bm034247a · Cited by 1,582
A Review of Cell Adhesion Studies for Biomedical and Biological Applications
Khalili, A., & Ahmad, M. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms160818149 · Cited by 951
Desmet, T., Morent, R., De Geyter, N., Leys, C., Schacht, E., & Dubruel, P. (2009) · Biomacromolecules · doi:10.1021/bm900186s · Cited by 689
Recent advance in surface modification for regulating cell adhesion and behaviors
Cai, S., Wu, C., Yang, W., Liang, W., Yu, H., & Liu, L. (2020) · Nanotechnology Reviews · doi:10.1515/ntrev-2020-0076 · Cited by 644
Ma, Z., Kotaki, M., Yong, T., He, W., & Ramakrishna, S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.026 · Cited by 558
Metadata
- Authors
- Wan, Y., Yang, J., Yang, J., Bei, J., & Wang, S.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2003-09
- Volume
- 24
- Issue
- 21
- Pages
- 3757-3764
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2048460441
- Cited by
- 166
- References
- 20
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.