Multiple microelectrode-recording system for human intracortical applications
The DOI matches its Crossref record; 49 of the 54 references it cites were found in a registry or an index.
Abstract
The human brain is dominated by the neocortex, a large folded surface, whose cellular and synaptic elements are arranged in layers. Since cortical structure is relatively constant across its surface, local information processing can be inferred from multiple laminar recordings of its electrical activity along a line perpendicular to its surface. Such recordings need to be spaced at least as close together as the cortical layers, and need to be wideband in order to sample both low frequency synaptic currents as well as high-frequency action potentials. Finally, any device used in the human brain must comply with strict safety standards. The current paper presents details of a system meeting these criteria, together with sample results obtained from epileptic subjects undergoing acute or chronic intracranial monitoring for definition of the epileptogenic region.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Dynamic Statistical Parametric Mapping
Dale, A. M., Liu, A. K., Fischl, B. R., Buckner, R. L., Belliveau, J. W., Lewine, J. D., & Halgren, E. (2000) · Neuron · doi:10.1016/s0896-6273(00)81138-1 · Cited by 1,787
Self-citationMitzdorf, U. (1985) · Physiological Reviews · doi:10.1152/physrev.1985.65.1.37 · Cited by 1,673
Nicholson, C., & Freeman, J. A. (1975) · Journal of Neurophysiology · doi:10.1152/jn.1975.38.2.356 · Cited by 692
IFCN standards for digital recording of clinical EEG
Nuwer, M. R., Comi, G., Emerson, R., Fuglsang-Frederiksen, A., Guérit, J.-M., Hinrichs, H., Ikeda, A., Jose C. Luccas, F., & Rappelsburger, P. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00106-5 · Cited by 671
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544 · cited 2×
“In ‘laminar’ recordings, simultaneous measurements of extracellular action potentials (AP) and field potentials (FP) are made from multiple, equally spaced locations spanning the cortical layers (Wise and Starr, 1970; Prohaska et al., 1979; Barna et al., 1981; Kuperstein and Wittington, 1981; Karmos et al., 1982).”
BackgroundExperimental optimization of current source-density technique for anuran cerebellum
Freeman, J. A., & Nicholson, C. (1975) · Journal of Neurophysiology · doi:10.1152/jn.1975.38.2.369 · Cited by 449
Ylinen, A., Soltész, I., Bragin, A., Penttonen, M., Sik, A., & Buzsáki, G. (1995) · Hippocampus · doi:10.1002/hipo.450050110 · Cited by 383
Mitzdorf, U. (1987) · International Journal of Neuroscience · doi:10.3109/00207458708985928 · Cited by 283
Brankačk, J., Stewart, M., & E. Fox, S. (1993) · Brain Research · doi:10.1016/0006-8993(93)90043-m · Cited by 275
Buzsáki, G., Czopf, J., Kondákor, I., & Kellényi, L. (1986) · Brain Research · doi:10.1016/0006-8993(86)90729-8 · Cited by 250
Research works printed but not linked: 3
- BeMent, 1985, Solid-state electrodes for multichannel multiplexed intracortical neuronal recording, IEEE Trans. Biomed. Eng., BME-32, 497
- Eichenbaum, 1986, Extracellular neural recording with multichannel microelectrodes, J. Electrophysiol. Tech., 13, 189
- Klemm, 1985, Head-mounted, eight channel amplifier records EEG and unit activity in freely moving rats, J. Electrophysiol. Tech., 12, 141
Cited by
Lakatos, P., Shah, A. S., Knuth, K. H., Ulbert, I., Karmos, G., & Schroeder, C. E. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00263.2005 · Cited by 1,237
“2A) from the spatially smoothed (Hamming window) local field potential profiles using a three-point formula for estimation of the second spatial derivative of voltage (Nicholson and Freeman 1975; Ulbert et al. 2001).”
MethodSelf-citationModelling and analysis of local field potentials for studying the function of cortical circuits
Einevoll, G. T., Kayser, C., Logothetis, N. K., & Panzeri, S. (2013) · Nature Reviews Neuroscience · doi:10.1038/nrn3599 · Cited by 857
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 475
“Numerous types of neural probes have been developed, including bundles of microwires [11]–[13], microwires embedded in neurotrophic assemblies [1], polymer substrate probes [14], [15], and several types of silicon-substrate probes [16]–[20].”
BackgroundHigh-frequency oscillations (HFOs) in clinical epilepsy
Jacobs, J., Staba, R., Asano, E., Otsubo, H., Wu, J. Y., Zijlmans, M., Mohamed, I., Kahane, P., Dubeau, F., Navarro, V., et al. (2012) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2012.03.001 · Cited by 443
“So far however these concerns were not confirmed (Howard et al., 1997; Ulbert et al., 2001).”
BackgroundThe generation and propagation of the human alpha rhythm
Halgren, M., Ulbert, I., Bastuji, H., Fabó, D., Erőss, L., Rey, M., Devinsky, O., Doyle, W. K., Mak-McCully, R., Halgren, E., et al. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1913092116 · Cited by 425
“Laminar microelectrodes were implanted perpendicular to the cortex in noneloquent tissue that was ultimately resected (35) (SI Appendix, SI Methods).”
BackgroundMethodInfluentialSelf-citation
Metadata
- Authors
- Ulbert, I., Halgren, E., Heit, G., & Karmos, G.
- Affiliations
- Stanford Medicine (US)
- Harvard University (US)
- Hungarian Academy of Sciences (HU)
- Corresponding author
- Ulbert, István
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2001-03
- Volume
- 106
- Issue
- 1
- Pages
- 69-79
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2028866298
- Cited by
- 173
- References
- 54
- Citations by year
- 2026: 4 · 2025: 4 · 2024: 8 · 2023: 12 · 2022: 9 · 2021: 7 · 2020: 3 · 2019: 5 · 2018: 3 · 2017: 5 · 2016: 10 · 2015: 10 · 2014: 7 · 2013: 9 · 2012: 8
- FWCI
- 1.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- National Institute of Neurological Disorders and Stroke (NS 18741, R01NS018741)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- intracortical recording, human neocortex, laminar recordings, epileptogenic zone mapping, intracranial monitoring, epilepsy, cortical electrical activity
- MeSH terms
- Action Potentials, Amplifiers, Electronic, Electroencephalography, Epilepsy, Humans, Microcomputers, Microelectrodes, Neocortex
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiple microelectrode-recording system for human intracortical applications. https://app.cochat.ai/papers/10.1016/s0165-0270(01)00330-2
- The paper
- Ulbert, I., Halgren, E., Heit, G., & Karmos, G. (2001). Multiple microelectrode-recording system for human intracortical applications. Journal of Neuroscience Methods. https://doi.org/10.1016/s0165-0270(01)00330-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.