Multiple microelectrode-recording system for human intracortical applications
The DOI matches its Crossref record; 49 of the 54 references it cites were found in a registry or an index.
Abstract
The human brain is dominated by the neocortex, a large folded surface, whose cellular and synaptic elements are arranged in layers. Since cortical structure is relatively constant across its surface, local information processing can be inferred from multiple laminar recordings of its electrical activity along a line perpendicular to its surface. Such recordings need to be spaced at least as close together as the cortical layers, and need to be wideband in order to sample both low frequency synaptic currents as well as high-frequency action potentials. Finally, any device used in the human brain must comply with strict safety standards. The current paper presents details of a system meeting these criteria, together with sample results obtained from epileptic subjects undergoing acute or chronic intracranial monitoring for definition of the epileptogenic region.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Dynamic Statistical Parametric Mapping
Dale, A. M., Liu, A. K., Fischl, B. R., Buckner, R. L., Belliveau, J. W., Lewine, J. D., & Halgren, E. (2000) · Neuron · doi:10.1016/s0896-6273(00)81138-1 · Cited by 1,787
Self-citationMitzdorf, U. (1985) · Physiological Reviews · doi:10.1152/physrev.1985.65.1.37 · Cited by 1,673
Nicholson, C., & Freeman, J. A. (1975) · Journal of Neurophysiology · doi:10.1152/jn.1975.38.2.356 · Cited by 692
IFCN standards for digital recording of clinical EEG
Nuwer, M. R., Comi, G., Emerson, R., Fuglsang-Frederiksen, A., Guérit, J.-M., Hinrichs, H., Ikeda, A., Jose C. Luccas, F., & Rappelsburger, P. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00106-5 · Cited by 671
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544 · cited 2×
“In ‘laminar’ recordings, simultaneous measurements of extracellular action potentials (AP) and field potentials (FP) are made from multiple, equally spaced locations spanning the cortical layers (Wise and Starr, 1970; Prohaska et al., 1979; Barna et al., 1981; Kuperstein and Wittington, 1981; Karmos et al., 1982).”
BackgroundExperimental optimization of current source-density technique for anuran cerebellum
Freeman, J. A., & Nicholson, C. (1975) · Journal of Neurophysiology · doi:10.1152/jn.1975.38.2.369 · Cited by 449
Ylinen, A., Soltész, I., Bragin, A., Penttonen, M., Sik, A., & Buzsáki, G. (1995) · Hippocampus · doi:10.1002/hipo.450050110 · Cited by 383
Mitzdorf, U. (1987) · International Journal of Neuroscience · doi:10.3109/00207458708985928 · Cited by 283
Brankačk, J., Stewart, M., & E. Fox, S. (1993) · Brain Research · doi:10.1016/0006-8993(93)90043-m · Cited by 275
Buzsáki, G., Czopf, J., Kondákor, I., & Kellényi, L. (1986) · Brain Research · doi:10.1016/0006-8993(86)90729-8 · Cited by 250
Research works printed but not linked: 3
- BeMent, 1985, Solid-state electrodes for multichannel multiplexed intracortical neuronal recording, IEEE Trans. Biomed. Eng., BME-32, 497
- Eichenbaum, 1986, Extracellular neural recording with multichannel microelectrodes, J. Electrophysiol. Tech., 13, 189
- Klemm, 1985, Head-mounted, eight channel amplifier records EEG and unit activity in freely moving rats, J. Electrophysiol. Tech., 12, 141
Cited by
Lakatos, P., Shah, A. S., Knuth, K. H., Ulbert, I., Karmos, G., & Schroeder, C. E. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00263.2005 · Cited by 1,237
“2A) from the spatially smoothed (Hamming window) local field potential profiles using a three-point formula for estimation of the second spatial derivative of voltage (Nicholson and Freeman 1975; Ulbert et al. 2001).”
MethodSelf-citationModelling and analysis of local field potentials for studying the function of cortical circuits
Einevoll, G. T., Kayser, C., Logothetis, N. K., & Panzeri, S. (2013) · Nature Reviews Neuroscience · doi:10.1038/nrn3599 · Cited by 857
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 475
“Numerous types of neural probes have been developed, including bundles of microwires [11]–[13], microwires embedded in neurotrophic assemblies [1], polymer substrate probes [14], [15], and several types of silicon-substrate probes [16]–[20].”
BackgroundHigh-frequency oscillations (HFOs) in clinical epilepsy
Jacobs, J., Staba, R., Asano, E., Otsubo, H., Wu, J. Y., Zijlmans, M., Mohamed, I., Kahane, P., Dubeau, F., Navarro, V., et al. (2012) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2012.03.001 · Cited by 443
“So far however these concerns were not confirmed (Howard et al., 1997; Ulbert et al., 2001).”
BackgroundThe generation and propagation of the human alpha rhythm
Halgren, M., Ulbert, I., Bastuji, H., Fabó, D., Erőss, L., Rey, M., Devinsky, O., Doyle, W. K., Mak-McCully, R., Halgren, E., et al. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1913092116 · Cited by 425
“Laminar microelectrodes were implanted perpendicular to the cortex in noneloquent tissue that was ultimately resected (35) (SI Appendix, SI Methods).”
BackgroundMethodInfluentialSelf-citationInvasive recordings from the human brain: clinical insights and beyond
Engel, A. K., Moll, C. K. E., Fried, I., & Ojemann, G. A. (2005) · Nature Reviews Neuroscience · doi:10.1038/nrn1585 · Cited by 419
“Future work should aim to combine these different approaches into a technology that allows both multi-scale and multi-region recording over days, weeks or even year”
BackgroundThe Human K-Complex Represents an Isolated Cortical Down-State
Cash, S. S., Halgren, E., Dehghani, N., Rossetti, A. O., Thesen, T., Wang, C., Devinsky, O., Kuzniecky, R., Doyle, W., Madsen, J. R., et al. (2009) · Science · doi:10.1126/science.1169626 · Cited by 394
Self-citationDevor, A., Tian, P., Nishimura, N., Teng, I. C., Hillman, E. M. C., Narayanan, S. N., Ulbert, I., Boas, D. A., Kleinfeld, D., & Dale, A. M. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.0134-07.2007 · Cited by 387
“The recorded potential was amplified and filtered into two signals: a low-frequency part (0.1–500 Hz, sampled at 2 kHz with 16 bits) and a high-frequency part (150 –5000 Hz, sampled at 20 kHz with 12 bits) (for details, see Ulbert et al., 2001).”
MethodSelf-citationDevor, A., Dunn, A. K., Andermann, M. L., Ulbert, I., Boas, D. A., & Dale, A. M. (2003) · Neuron · doi:10.1016/s0896-6273(03)00403-3 · Cited by 387
“Optimal experimental design for event-related(Ulbert et al., 2001b). fMRI.”
MethodSelf-citationPettersen, K. H., Devor, A., Ulbert, I., Dale, A. M., & Einevoll, G. T. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.12.005 · Cited by 353
Self-citationWang, C., Ulbert, I., Schomer, D. L., Marinkovic, K., & Halgren, E. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.4151-04.2005 · Cited by 295
“Population transmembrane current flows were estimated using linear current source density (CSD) analysis (Nicholson and Freeman, 1975; Ulbert et al., 2001b), calculated using the second spatial derivative of local field potentials (LFP).”
BackgroundMethodSelf-citationLarge-scale neural recordings with single neuron resolution using Neuropixels probes in human cortex
Paulk, A. C., Kfir, Y., Khanna, A. R., Mustroph, M. L., Trautmann, E. M., Soper, D. J., Stavisky, S. D., Welkenhuysen, M., Dutta, B., Shenoy, K. V., et al. (2022) · Nature Neuroscience · doi:10.1038/s41593-021-00997-0 · Cited by 283
“In addition to investigating the frequency of waveform types in this dataset, we wanted to link the current Neuropixels spatially subsam-pled APs to past human single-unit studies using technologies with lower contact-to-contact spatial resolution ( > 150-µ m spacing 7,13 ).”
MethodJerbi, K., Ossandón, T., Hamamé, C. M., Senova, S., Dalal, S. S., Jung, J., Minotti, L., Bertrand, O., Berthoz, A., Kahane, P., et al. (2009) · Human Brain Mapping · doi:10.1002/hbm.20750 · Cited by 272
“Future trends include increased direct sampling of single-unit neural activity in the human brain via various microelectrode recording techniques [Neves and Ruther, 2007; Ulbert et al., 2001].”
MethodGulyás, A. I., Szabó, G. G., Ulbert, I., Holderith, N., Monyer, H., Erdélyi, F., Szabó, G., Freund, T. F., & Hájos, N. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.4104-10.2010 · Cited by 262
“Inhomogeneous conductivity was not taken into account, second spatial derivative was calculated by the nearest neighbor method, and highspatial frequency noise was reduced by Hamming-window smoothing (Ulbert et al., 2001).”
Self-citationAmplitude Variability and Extracellular Low-Pass Filtering of Neuronal Spikes
Pettersen, K. H., & Einevoll, G. T. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.111179 · Cited by 255
“The high-pass frequency filtering used to extract the MUA (lower cutoff at typically 750 Hz (6,7)) makes the MUA signal even more spatially confined, since only the highest AP frequencies with the shortest effective dipole lengths are retained.”
MethodLaminar analysis of slow wave activity in humans
Csercsa, R., Dombovári, B., Fabó, D., Wittner, L., Erőss, L., Entz, L., Sólyom, A., Rásonyi, G., Szűcs, A., Kelemen, A., et al. (2010) · Brain · doi:10.1093/brain/awq169 · Cited by 239
“In addition to the surface electrodes, a 350mm diameter, 24-contact experimental laminar multichannel microelectrode array was implanted perpendicular to the cortical surface, underneath the clinical grids (Ulbert et al., 2001a, b, 2004a; Cash et al., 2009; Keller et al., 2009).”
BackgroundMethodInfluentialSelf-citationCoupling of the cortical hemodynamic response to cortical and thalamic neuronal activity
Devor, A., Ulbert, I., Dunn, A. K., Narayanan, S. N., Jones, S. R., Andermann, M. L., Boas, D. A., & Dale, A. M. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0407789102 · Cited by 222
Self-citationDevor, A., Hillman, E. M. C., Tian, P., Waeber, C., Teng, I. C., Ruvinskaya, L., Shalinsky, M. H., Zhu, H., Haslinger, R. H., Narayanan, S. N., et al. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.4307-08.2008 · Cited by 206
“Following this, the electrode was withdrawn and replaced by a linear multielectrode array with 24 contacts spaced at 100 m (Ulbert et al., 2001).”
MethodInfluentialSelf-citationHeterogeneous neuronal firing patterns during interictal epileptiform discharges in the human cortex
Keller, C. J., Truccolo, W., Gale, J. T., Eskandar, E., Thesen, T., Carlson, C., Devinsky, O., Kuzniecky, R., Doyle, W. K., Madsen, J. R., et al. (2010) · Brain · doi:10.1093/brain/awq112 · Cited by 194
Self-citationHuman Intracranial Recordings and Cognitive Neuroscience
Mukamel, R., & Fried, I. (2012) · Annual Review of Psychology · doi:10.1146/annurev-psych-120709-145401 · Cited by 182
“F or p er so na l u se o nl y. LFPs and unit activity from distinct cortical layers (Ulbert et al. 2001).”
BackgroundAstrocytes convert network excitation to tonic inhibition of neurons
Héja, L., Nyitrai, G., Kékesi, O., Dobolyi, Á., Szabó, P., Fiáth, R., Ulbert, I., Pál-Szenthe, B., Palkovits, M., & Kardos, J. (2012) · BMC Biology · doi:10.1186/1741-7007-10-26 · Cited by 174
“Inhomogeneous conductivity was not taken into account, second spatial derivative was calculated by the nearest neighbour method, and high spatial frequency noise was reduced by Hamming-window smoothing [84,85].”
MethodSelf-citationSzostak, K. M., Grand, L., & Constandinou, T. G. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00665 · Cited by 168
“(C) Plexon’s 24 channel linear Thumbtack microelectrode array (Ulbert et al., 2001)2.”
MethodIntegrated circuit amplifiers for multi-electrode intracortical recording
Jochum, T., Denison, T., & Wolf, P. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/1/012001 · Cited by 167
First-Pass Selectivity for Semantic Categories in Human Anteroventral Temporal Lobe
Chan, A. M., Baker, J. M., Eskandar, E., Schomer, D., Ulbert, I., Marinkovic, K., Cash, S. S., & Halgren, E. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.3122-11.2011 · Cited by 153
“CSD was computed as the second spatial derivative of field potentials after applying a five-point Hamming filter (Ulbert et al., 2001).”
MethodSelf-citationEinevoll, G. T., Pettersen, K. H., Devor, A., Ulbert, I., Halgren, E., & Dale, A. M. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00845.2006 · Cited by 148
“A linear array multielectrode with 23 contacts with diameter 0.04 mm spaced at 0.1 mm was used (Ulbert et al. 2001), and the data from contacts 2–23 were used in the modeling.”
InfluentialSelf-citationImprovement of EEG Signal Acquisition: An Electrical Aspect for State of the Art of Front End
Uşaklı, A. B. (2010) · Computational Intelligence and Neuroscience · doi:10.1155/2010/630649 · Cited by 146
Estimation of population firing rates and current source densities from laminar electrode recordings
Pettersen, K. H., Hagen, E., & Einevoll, G. T. (2007) · Journal of Computational Neuroscience · doi:10.1007/s10827-007-0056-4 · Cited by 145
“To mimic the net effect of the combined analog and digital filtering used in Ulbert et al. (2001) and Einevoll et al. (2007), the MUA was obtained by first band-pass filtering from 100 to 5,000 Hz, followed by a second band-pass filtering from 750 to 5,000 Hz.”
BackgroundMethodInfluentialHerwik, S., Kisban, S., Aarts, A. A. A., Seidl, K., Girardeau, G., Benchenane, K., Zugaro, M. B., Wiener, S. I., Paul, O., Neves, H. P., et al. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/7/074008 · Cited by 115
“Besides single wires, rather specific wire assemblies such as multi-wire electrodes with a probe diameter of 350 μm have been reported [2].”
BackgroundHajos, N., Karlocai, M. R., Nemeth, B., Ulbert, I., Monyer, H., Szabo, G., Erdelyi, F., Freund, T. F., & Gulyas, A. I. (2013) · Journal of Neuroscience · doi:10.1523/jneurosci.5729-12.2013 · Cited by 107
“Current source density (CSD) calculations were made using the three-point formula smoothed by Hamming window (Ulbert et al., 2001).”
MethodInfluentialSelf-citationPhysiological sharp wave-ripples and interictal events in vitro: what’s the difference?
Karlócai, M. R., Kohus, Z., Káli, S., Ulbert, I., Szabó, G., Máté, Z., Freund, T. F., & Gulyás, A. I. (2014) · Brain · doi:10.1093/brain/awt348 · Cited by 99
“Current source density (CSD) calculations were made using the three-point formula smoothed by Hamming window (Ulbert et al., 2001).”
MethodInfluentialSelf-citationWittner, L., Huberfeld, G., Clémenceau, S., Erőss, L., Dezamis, E., Entz, L., Ulbert, I., Baulac, M., Freund, T. F., Maglóczky, Z., et al. (2009) · Brain · doi:10.1093/brain/awp238 · Cited by 97
“…(24 channels, distance between contacts: 150 mm) (Ulbert et al., 2001, 2004a, b; Fabó et al., 2008 Current source density (CSD), an estimate of population transmembrane currents, and multi-unit activity (MUA) were calculated from the LFPg using standard techniques (Ulbert et al., 2001, 2004b).”
Self-citationUltra-Rapid Sensory Responses in the Human Frontal Eye Field Region
Kirchner, H., Barbeau, E. J., Thorpe, S. J., Regis, J., & Liegeois-Chauvel, C. (2009) · Journal of Neuroscience · doi:10.1523/jneurosci.1233-09.2009 · Cited by 97
Ulbert, I., Heit, G., Madsen, J., Karmos, G., & Halgren, E. (2004) · Epilepsia · doi:10.1111/j.0013-9580.2004.04011.x · Cited by 96
“Details of electrode construction, recordings, and analysis techniques can be found in (20,21).”
BackgroundSelf-citationThe Emergence of Single Neurons in Clinical Neurology
Cash, S. S., & Hochberg, L. R. (2015) · Neuron · doi:10.1016/j.neuron.2015.03.058 · Cited by 87
Martínek, R., Ládrová, M., Šidiková, M., Jaroš, R., Behbehani, K., Kahankova, R. V., & Kawala‐Sterniuk, A. (2021) · Sensors · doi:10.3390/s21155186 · Cited by 118
Sellers, K. K., Bennett, D. V., Hutt, A., Williams, J. H., & Fröhlich, F. (2015) · Journal of Neurophysiology · doi:10.1152/jn.00923.2014 · Cited by 83
“CSD was determined by calculating the second spatial derivative of the low-pass filtered and smoothed LFP in response to full-field flashes presented at a rate of 1 Hz (Ulbert et al. 2001).”
Processing stages underlying word recognition in the anteroventral temporal lobe
Halgren, E., Wang, C., Schomer, D. L., Knake, S., Marinković, K., Wu, J. K., & Ulbert, I. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.10.053 · Cited by 86
“Variable electrode spacing or potential amplification could produce spurious CSD signals, but these effects were evaluated experimentally in our system and found to be less than 5% (Ulbert et al., 2001a).”
BackgroundMethodInfluentialSelf-citationPettersen, K. H., Lindén, H., Dale, A. M., & Einevoll, G. T. (2012) · Handbook of Neural Activity Measurement · doi:10.1017/cbo9780511979958.004 · Cited by 70
Obeid, M., Wyllie, E., Rahi, A. C., & Mikati, M. A. (2008) · European Journal of Paediatric Neurology · doi:10.1016/j.ejpn.2008.05.007 · Cited by 71
“The laminar electrode is an experimental device that allows the acute or long-term recording of electrical activity from the different layers of the neocortex.(70)”
Tóth, K., Hofer, K. T., Kandrács, Á., Entz, L., Bagó, A. G., Erőss, L., Jordán, Z., Nagy, G., Sólyom, A., Fabó, D., et al. (2017) · The Journal of Physiology · doi:10.1113/jp275413 · Cited by 72
“The extracellular local field potential gradient (LFPg) was recorded with a laminar multiple channel (24 channels, distance between contacts: 150 μm) microelectrode (Ulbert et al., 2001; Ulbert et al., 2004a; Ulbert et al., 2004b; Fabó et al., 2008; Wittner et al., 2009), using a custom made 48-channel voltage gradien…”
MethodSelf-citationGeneralized Laminar Population Analysis (gLPA) for Interpretation of Multielectrode Data from Cortex
Głąbska, H. T., Norheim, E., Devor, A., Dale, A. M., Einevoll, G. T., & Wójcik, D. K. (2016) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2016.00001 · Cited by 69
“…filtered extracellular signals, a procedure that has been shown to give results similar to the spike-detection method in an experimental setting (Ulbert et al., 2001) and to ground-truth spike-train results in a detailed Frontiers in Neuroinformatics | www.frontiersin.org 8 January 2016 |…”
MethodDeep-brain silicon multielectrodes for simultaneous in vivo neural recording and drug delivery
Pongracz, A., Fekete, Z., Márton, G., Bérces, Z., Ulbert, I., & Fürjes, P. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.01.032 · Cited by 77
Self-citationProperties of in vivo interictal spike generation in the human subiculum
Fabo, D., Magloczky, Z., Wittner, L., Pek, A., Eross, L., Czirjak, S., Vajda, J., Solyom, A., Rasonyi, G., Szucs, A., et al. (2008) · Brain · doi:10.1093/brain/awm297 · Cited by 66
“Details about CSD and MUA calculations were published earlier (Ulbert et al., 2001, 2004a).”
MethodSelf-citationde Curtis, M., Jefferys, J. G. R., & Avoli, M. (2012) · Oxford University Press eBooks · doi:10.1093/med/9780199746545.003.0017 · Cited by 87
Enzyme-based choline and l-glutamate biosensor electrodes on silicon microprobe arrays
Frey, O., Holtzman, T., McNamara, R., Theobald, D. E. H., van der Wal, P. D., de Rooij, N. F., Dalley, J. W., & Koudelka‐Hep, M. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.073 · Cited by 69
Flexible, scalable, high channel count stereo-electrode for recording in the human brain
Lee, K., Paulk, A. C., Ro, Y. G., Cleary, D. R., Tonsfeldt, K. J., Kfir, Y., Pezaris, J. S., Tchoe, Y., Lee, J., Bourhis, A. M., et al. (2024) · Nature Communications · doi:10.1038/s41467-023-43727-9 · Cited by 64
“This design is intended for use in the intraoperative setting and resembles other microelectrode arrays (often called laminar arrays), which were designed to capture activity across the cortical layers 35 .”
MethodSelf-citationShort and long term biocompatibility of NeuroProbes silicon probes
Grand, L., Wittner, L., Herwik, S., Göthelid, E., Ruther, P., Oscarsson, S. O., Neves, H. P., Dombovári, B., Csercsa, R., Karmos, G., et al. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.04.009 · Cited by 74
Self-citationHuman entorhinal gamma and theta oscillations selective for remote autobiographical memory
Steinvorth, S., Wang, C., Ulbert, I., Schomer, D., & Halgren, E. (2010) · Hippocampus · doi:10.1002/hipo.20597 · Cited by 61
Self-citationModelling the magnetic signature of neuronal tissue
Blagoev, K. B., Mihaila, B., Travis, B. J., Alexandrov, L. B., Bishop, A. R., Ranken, D. M., Posse, S., Gasparovic, C., Mayer, A. R., Aine, C. J., et al. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.04.033 · Cited by 70
“Laminar electrodes were 350 μm in diameter in a 5-mm segment at their tips, containing a linear array of 24 Platinum-Iridium contacts (40-μm diameter separated by 110 μm) (Ulbert et al., 2001).”
BackgroundSelf-citationTemporal Analysis of the Flow From V1 to the Extrastriate Cortex in Humans
Inui, K., & Kakigi, R. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00103.2006 · Cited by 63
Bangera, N. B., Schomer, D. L., Dehghani, N., Ulbert, I., Cash, S. S., Papavasiliou, S., Eisenberg, S. R., Dale, A. M., & Halgren, E. (2010) · Journal of Computational Neuroscience · doi:10.1007/s10827-009-0205-z · Cited by 61
“The intracranial potential was obtained while passing a biphasic square wave current pulse using a recording system developed by Ulbert et al. (Ulbert et al. 2001).”
MethodSelf-citationSuperficial slow rhythms integrate cortical processing in humans
Halgren, M., Fabó, D., Ulbert, I., Madsen, J. R., Erőss, L., Doyle, W. K., Devinsky, O., Schomer, D., Cash, S. S., & Halgren, E. (2018) · Scientific Reports · doi:10.1038/s41598-018-20662-0 · Cited by 59
Self-citationHeterogeneous Origins of Human Sleep Spindles in Different Cortical Layers
Hagler, D. J., Ulbert, I., Wittner, L., Erőss, L., Madsen, J. R., Devinsky, O., Doyle, W., Fabó, D., Cash, S. S., & Halgren, E. (2018) · The Journal of Neuroscience · doi:10.1523/jneurosci.2241-17.2018 · Cited by 58
“We noted that the superficial source was more common when the direct calculation procedure was used (Ulbert et al., 2001), rather than the inverse estimation procedure (Pettersen et al., 2006) followed here.”
BackgroundMethodInfluentialSelf-citationHagen, E., Ness, T. V., Khosrowshahi, A., Sørensen, C., Fyhn, M., Hafting, T., Franke, F., & Einevoll, G. T. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.01.029 · Cited by 68
Martínek, R., Ládrová, M., Šidiková, M., Jaroš, R., Behbehani, K., Kahankova, R. V., & Kawala‐Sterniuk, A. (2021) · Sensors · doi:10.3390/s21196343 · Cited by 64
Brennan, N. M. P., Peck, K. K., & Holodny, A. I. (2016) · Topics in Magnetic Resonance Imaging · doi:10.1097/rmr.0000000000000074 · Cited by 55
“In this technique, the median nerve is stimulated and the response is detected from a strip electrode array draped over the Rolandic region.(105) A phase reversal between 2 of the recording cortical electrodes indicates a likely position of the central sulcus.”
MethodMicroelectrode recordings in human epilepsy: a case for clinical translation
Chari, A., Thornton, R. C., Tisdall, M. M., & Scott, R. C. (2020) · Brain Communications · doi:10.1093/braincomms/fcaa082 · Cited by 58
Lee, S., Thunemann, M., Lee, K., Cleary, D. R., Tonsfeldt, K. J., Oh, H., Azzazy, F., Tchoe, Y., Bourhis, A. M., Hossain, L., et al. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202112045 · Cited by 59
Halgren, E., Kaestner, E., Marinkovic, K., Cash, S. S., Wang, C., Schomer, D. L., Madsen, J. R., & Ulbert, I. (2015) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2015.03.021 · Cited by 49
“Clinical electrodes were modified to be smaller diameter (350μ) in a 5 mm segment at their tips, containing 24 90%Pt-10%Ir contacts, each 40μ in diameter, at 150μ center-to-center spacing (Ulbert et al., 2001).”
BackgroundMethodInfluentialSelf-citationLaminar analysis of the slow wave activity in the somatosensory cortex of anesthetized rats
Fiáth, R., Kerekes, B. P., Wittner, L., Tóth, K., Beregszászi, P., Horváth, D., & Ulbert, I. (2016) · European Journal of Neuroscience · doi:10.1111/ejn.13274 · Cited by 53
“The brain signals were amplified and filtered (gain: 1000, band-pass: 0.1–7000 Hz) by a custom-made headstage and amplifier (Ulbert et al., 2001), and were digitized at 20 kHz/channel sampling rate, on 24 channels at 16-bit precision (PCI-6259; National Instruments, Austin, TX, USA).”
BackgroundMethodInfluentialSelf-citationAdvances in the Application of Technology to Epilepsy: The CIMIT/NIO Epilepsy Innovation Summit
Schachter, S. C., Guttag, J. V., Schiff, S. J., & Schomer, D. L. (2009) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2009.06.028 · Cited by 51
Microscale Physiological Events on the Human Cortical Surface
Paulk, A. C., Yang, J. C., Cleary, D. R., Soper, D. J., Halgren, M., O’Donnell, A. R., Lee, S., Ganji, M., Ro, Y. G., Oh, H., et al. (2021) · Cerebral Cortex · doi:10.1093/cercor/bhab040 · Cited by 50
Self-citationDe Curtis, M., Jefferys, J. G. R., & Avoli, M. (2012) · IRIS Research product catalog (Sapienza University of Rome) · Cited by 54
Ulbert, I., Karmos, G., Heit, G., & Halgren, E. (2001) · Human Brain Mapping · doi:10.1002/hbm.1035 · Cited by 44
Self-citationModified Neuropixels probes for recording human neurophysiology in the operating room
Coughlin, B. F., Muñoz, W., Kfir, Y., Young, M. J., Meszéna, D., Jamali, M., Caprara, I., Hardstone, R., Khanna, A. R., Mustroph, M. L., et al. (2023) · Nature Protocols · doi:10.1038/s41596-023-00871-2 · Cited by 51
Pinotsis, D. A., Geerts, J. P., Pinto, L., FitzGerald, T. H. B., Litvak, V., Auksztulewicz, R., & Friston, K. J. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.11.041 · Cited by 39
“Multi-electrode shanks and multi-unit probes provide a unique window on the functional microarchitecture of cortical and subcortical structures, like V1, temporal cortex, the hippocampus or the cerebellum, see e.g. (Olsson et al., 2005; Obien et al., 2014; Kelly et al., 2007; Ulbert et al., 2001).”
BackgroundModel-based source localization of extracellular action potentials
Somogyvári, Z., Zalányi, L., Ulbert, I., & Érdi, P. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.04.002 · Cited by 52
Self-citationA Multimodal, SU-8 - Platinum - Polyimide Microelectrode Array for Chronic In Vivo Neurophysiology
Márton, G., Orbán, G., Kiss, M., Fiáth, R., Pongrácz, A., & Ulbert, I. (2015) · PLOS ONE · doi:10.1371/journal.pone.0145307 · Cited by 35
“The probe is an upgraded version of the thumbtack-like neural MEA, shown in Fig 1A, which had been successfully used for recording field potentials, multiple unit and single unit activities in behaving and anaesthetized humans [35].”
MethodSelf-citationUlbert, I., Maglóczky, Z., Eross, L., Czirják, S., Vajda, J., Bognár, L., Tóth, S., Szabó, Z., Halász, P., Fabó, D., et al. (2004) · Experimental Neurology · doi:10.1016/j.expneurol.2003.12.003 · Cited by 40
“Ulbert et al. / Experimental Neurology 187 (2004) 310–318 311”
BackgroundSelf-citationA novel multisite silicon probe for high quality laminar neural recordings
Grand, L., Pongracz, A., Vázsonyi, É. B., Márton, G., Gubán, D., Fiáth, R., Kerekes, B. P., Karmos, G., Ulbert, I., & Battistig, G. (2010) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2010.12.019 · Cited by 33
Self-citationBlomquist, P., Devor, A., Indahl, U. G., Ulbert, I., Einevoll, G. T., & Dale, A. M. (2009) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1000328 · Cited by 33
Self-citationTranslational Organic Neural Interface Devices at Single Neuron Resolution
Hassan, A. R., Zhao, Z., Ferrero, J. J., Cea, C., Jastrzebska‐Perfect, P., Myers, J. C., Asman, P., Ince, N. F., McKhann, G. M., Viswanathan, A., et al. (2022) · Advanced Science · doi:10.1002/advs.202202306 · Cited by 28
The hippocampal CA3 region can generate two distinct types of sharp wave‐ripple complexes, in vitro
Hofer, K. T., Kandrács, Á., Ulbert, I., Pál, I., Szabó, C., Héja, L., & Wittner, L. (2014) · Hippocampus · doi:10.1002/hipo.22361 · Cited by 36
“01 Hz–10 kHz (Ulbert et al., 2001; Ulbert et al., 2004a,b; Fab o et al., 2008).”
Self-citationSomogyvári, Z., Cserpán, D., Ulbert, I., & Érdi, P. (2012) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2012.08249.x · Cited by 35
Self-citationOn the Estimation of Population-Specific Synaptic Currents from Laminar Multielectrode Recordings
Gratiy, S. L., Devor, A., Einevoll, G. T., & Dale, A. M. (2011) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2011.00032 · Cited by 33
“Only the low-frequency part (0.1–500 Hz), sampled at 2 kHz with 16 bits (Ulbert et al., 2001) was used in the present analysis.”
BackgroundMethodInfluentialLisgaras, C. P., de la Prida, L. M., Bertram, E. H., Cunningham, M. O., Henshall, D. C., Liu, A. A., Gnatkovsky, V., Balestrini, S., de Curtis, M., Galanopoulou, A. S., et al. (2025) · Epilepsia · doi:10.1111/epi.18282 · Cited by 31
DREDge: robust motion correction for high-density extracellular recordings across species
Windolf, C., Yu, H. Y., Paulk, A. C., Meszéna, D., Muñoz, W., Boussard, J., Hardstone, R., Caprara, I., Jamali, M., Kfir, Y., et al. (2025) · Nature Methods · doi:10.1038/s41592-025-02614-5 · Cited by 37
“This additional step resulted in smoothed LFP signals similar to those observed in previous studies 46,47 (Fig.”
Self-citationA 3D slim-base probe array for in vivo recorded neuron activity
Aarts, A. A. A., Neves, H. P., Ulbert, I., Wittner, L., Grand, L., Fontes, M., Herwik, S., Kisban, S., Paul, O., Ruther, P., et al. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650532 · Cited by 26
Self-citationMolnár, M., Csuhaj, R., Gaál, Z. A., Czigler, B., Ulbert, I., Boha, R., & Kondákor, I. (2008) · Psychophysiology · doi:10.1111/j.1469-8986.2008.00648.x · Cited by 31
Self-citationIntracranial microprobe for evaluating neuro-hemodynamic coupling in unanesthetized human neocortex
Keller, C. J., Cash, S. S., Narayanan, S. N., Wang, C., Kuzniecky, R., Carlson, C., Devinsky, O., Thesen, T., Doyle, W., Sassaroli, A., et al. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.01.036 · Cited by 24
“Assuming that the currents are radially symmetric around the laminar electrode trajectory, CSD is calculated as the second spatial derivative of field potentials (0.5–30Hz) after applying a 5-point Hamming filter (Ulbert et al., 2001).”
BackgroundMethodInfluentialSelf-citationVatsyayan, R., Lee, J., Bourhis, A. M., Tchoe, Y., Cleary, D. R., Tonsfeldt, K. J., Lee, K., Montgomery‐Walsh, R., Paulk, A. C., Hoi Sang, U., et al. (2023) · MRS Bulletin · doi:10.1557/s43577-023-00537-0 · Cited by 29
Novel four-sided neural probe fabricated by a thermal lamination process of polymer films
Shin, S., Kim, J., Jeong, J., Gwon, T. M., Lee, S., & Kim, S. J. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2016.12.017 · Cited by 26
Intracranial neuronal ensemble recordings and analysis in epilepsy
Tóth, E., Fabó, D., Entz, L., Ulbert, I., & Erőss, L. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.09.028 · Cited by 24
Self-citationIntracranial Markers of Conscious Face Perception in Humans
Baroni, F., van Kempen, J., Kawasaki, H., Kovach, C. K., Oya, H., Howard, M. A., Adolphs, R., & Tsuchiya, N. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.074 · Cited by 24
Electrophysiological Signatures of Visual Recognition Memory across All Layers of Mouse V1
Hayden, D. J., Finnie, P. S. B., Thomazeau, A., Li, A. Y., Cooke, S. F., & Bear, M. F. (2023) · Journal of Neuroscience · doi:10.1523/jneurosci.0090-23.2023 · Cited by 21
“We then used a five-point hamming window to compute the CSD using the standard formula (Ulbert et al., 2001; Speed et al., 2019).”
MethodLaminar analysis of initiation and spread of epileptiform discharges in three in vitro models
Borbély, S., Halasy, K., Somogyvári, Z., Détári, L., & Világi, I. (2005) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2005.11.018 · Cited by 21
Huang, H., Gregg, N. M., Valencia, G. O., Brinkmann, B. H., Lundstrom, B. N., Worrell, G. A., Miller, K. J., & Hermes, D. (2023) · Journal of Neuroscience · doi:10.1523/jneurosci.1325-22.2023 · Cited by 24
Differential cortical layer engagement during seizure initiation and spread in humans
Bourdillon, P., Ren, L., Halgren, M., Paulk, A. C., Salami, P., Ulbert, I., Fabó, D., King, J.-R., Sjoberg, K. M., Eskandar, E. N., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-48746-8 · Cited by 23
“CSD was measured by taking the second spatial derivative of the LFP and then applying a 5-point Hamming fi lter 15,49,50 .”
InfluentialSelf-citationThe laminar profile of sleep spindles in humans
Ujma, P. P., Hajnal, B., Bódizs, R., Gombos, F., Erőss, L., Wittner, L., Halgren, E., Cash, S. S., Ulbert, I., & Fabó, D. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117587 · Cited by 18
“All data segments were filtered to a generic sleep spindle range (10-16 Hz, two-way FIR filtering implemented in Matlab EEGLab) and smoothed across layers using a Hamming window (Ulbert et al., 2001; Csercsa et al., 2010).”
InfluentialSelf-citationSynaptic alterations and neuronal firing in human epileptic neocortical excitatory networks
Bod, R.-B., Tóth, K., Essam, N., Tóth, E. Z., Erőss, L., Entz, L., Bagó, A. G., Fabó, D., Ulbert, I., & Wittner, L. (2023) · Frontiers in Synaptic Neuroscience · doi:10.3389/fnsyn.2023.1233569 · Cited by 21
Self-citationHalgren, M., Kang, R., Voytek, B., Ulbert, I., Fabó, D., Erőss, L., Wittner, L., Madsen, J. R., Doyle, W., Devinsky, O., et al. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.07.28.454235 · Cited by 23
“To measure human cortical PSDs from different layers simultaneously, we made laminar micoelectrode recordings in 16 patients with medically intractable epilepsy (Halgren et al., 2018; István Ulbert et al., 2001) (Fig.”
BackgroundMethodInfluentialSelf-citationA low-profile three-dimensional neural probe array using a silicon lead transfer structure
Cheng, M.-Y., Je, M., Tan, K. L., Tan, E. L., Lim, R., Yao, L., Li, P., Park, W.-T., Phua, E. J. R., Gan, C. L., et al. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/9/095013 · Cited by 18
The brain during free movement – What can we learn from the animal model
Händel, B., & Schölvinck, M. L. (2017) · Brain Research · doi:10.1016/j.brainres.2017.09.003 · Cited by 20
Kerekes, B. P., Toth, K., Kaszás, A., Chiovini, B., Szadai, Z., Szalay, G., Palfi, D., Spitzer, K., Rózsa, B., Ulbert, I., et al. (2014) · Neurophotonics · doi:10.1117/1.nph.1.1.011013 · Cited by 16
Self-citationYu, C., Sellers, K. K., Radtke‐Schuller, S., Lu, J., Xing, L., Ghukasyan, V., Li, Y., Shih, Y. I., Murrow, R. W., & Frӧhlich, F. (2016) · European Journal of Neuroscience · doi:10.1111/ejn.13116 · Cited by 20
“CSD profiles were spatially smoothed with a Hanning window (Ulbert et al., 2001).”
MethodFabó, D., Bokodi, V., Szabó, J.-P., Tóth, E., Salami, P., Keller, C. J., Hajnal, B., Thesen, T., Devinsky, O., Doyle, W., et al. (2023) · Scientific Reports · doi:10.1038/s41598-022-22497-2 · Cited by 22
Self-citationPresence of synchrony‐generating hubs in the human epileptic neocortex
Kandrács, Á., Hofer, K. T., Tóth, K., Tóth, E. Z., Entz, L., Bagó, A. G., Erőss, L., Jordán, Z., Nagy, G., Fabó, D., et al. (2019) · The Journal of Physiology · doi:10.1113/jp278499 · Cited by 17
“Briefly, we used a 24 contact (distance between contacts: 150 μm) laminar microelectrode (Ulbert et al. 2001; Ulbert et al. 2004a; Ulbert et al. 2004b; Fabó et al. 2008; Wittner et al. 2009) and a custom-made voltage gradient amplifier of bandpass 0.”
MethodSelf-citationDevor, A., Boas, D. A., Einevoll, G. T., Buxton, R. B., & Dale, A. M. (2011) · Advances in neurobiology · doi:10.1007/978-1-4614-1788-0_15 · Cited by 21
“, the multi-unit activity (MUA) (Schroeder et al., 2001; Ulbert et al., 2001; Pettersen et al., 2008; Blomquist et al., 2009).”
BackgroundMethodInfluentialHow Human Single-Neuron Recordings Can Help Us Understand Cognition: Insights from Memory Studies
Kubska, Z. R., & Kamiński, J. (2021) · Brain Sciences · doi:10.3390/brainsci11040443 · Cited by 17
“The other electrode successfully applied in human electrophysiology is a linear probe [75,76].”
BackgroundSensing local field potentials with a directional and scalable depth electrode array
Abrego, A. M., Khan, W., Wright, C. E., Islam, M. R., Ghajar, M. H., Bai, X., Tandon, N., & Seymour, J. P. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acb230 · Cited by 18
“Further evidence of the impact of substrate shielding is the accuracy of a 11 × 1 (similar to a linear U-probe (Ulbert et al 2001)) vs. a 1 × 8 DISC configuration, which was 68.8% vs 78.1%, respectively (table 1).”
Influential
Metadata
- Authors
- Ulbert, I., Halgren, E., Heit, G., & Karmos, G.
- Affiliations
- Stanford Medicine (US)
- Harvard University (US)
- Hungarian Academy of Sciences (HU)
- Corresponding author
- Ulbert, István
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2001-03
- Volume
- 106
- Issue
- 1
- Pages
- 69-79
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2028866298
- Cited by
- 173
- References
- 54
- Citations by year
- 2026: 4 · 2025: 4 · 2024: 8 · 2023: 12 · 2022: 9 · 2021: 7 · 2020: 3 · 2019: 5 · 2018: 3 · 2017: 5 · 2016: 10 · 2015: 10 · 2014: 7 · 2013: 9 · 2012: 8
- FWCI
- 1.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- National Institute of Neurological Disorders and Stroke (NS 18741, R01NS018741)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- intracortical recording, human neocortex, laminar recordings, epileptogenic zone mapping, intracranial monitoring, epilepsy, cortical electrical activity
- MeSH terms
- Action Potentials, Amplifiers, Electronic, Electroencephalography, Epilepsy, Humans, Microcomputers, Microelectrodes, Neocortex
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.