Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record.

Metallized polymer fibers as leadwires and intrafascicular microelectrodes

McNaughton, Timothy G., Horch, Kenneth W. · 1996 · Journal of Neuroscience Methods

Abstract

We have developed a process for producing fine, very flexible microwires suitable for use as small signal leadwires or nerve electrodes. The process incorporates metallization of high-performance monofilament polymer fibers to yield electrically conductive fibers with greatly improved flexibility over solid metal wires of similar strength. The metallization layers are produced by serial vacuum deposition of a 0.3 micron thick coating of three metals, titanium-tungsten (Ti/W), gold (Au), and platinum (Pt), onto monofilament, poly-p-phenyl-terephthalate aramid fibers (Kevlar). The metallized fibers are then insulated with an approx. 1 micron thick layer of silicone elastomer. The result is a microlead with high electrical conductivity (linear resistance = 30 omega/cm), desirable interfacial properties, excellent mechanical stability and extremely high flexibility. These physical characteristics are appropriate for application as signal leadwires or recording/stimulating electrodes where small size and high flexibility are paramount. In this paper we report on the electrical and mechanical properties of these metallized fibers and demonstrate their use as intrafascicular electrodes for recording multi-unit neural activity in feline peripheral nerves.

Overview

Integrity signals

Registry

Crossref · 10.1016/s0165-0270(96)00111-2

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Still being checked.

Cited by

See all 77

Metadata

Authors
McNaughton, T. G., & Horch, K. W.
Affiliations
University of Utah (US)
Corresponding author
Horch, Kenneth W.
Venue
Journal of Neuroscience Methods
Publisher
Elsevier BV
Published
1996-12
Volume
70
Issue
1
Pages
103-107
ISSN
0165-0270 (ISSN-L)
OpenAlex
W2027811212
Cited by
76
References
0
Citations by year
2025: 1 · 2023: 2 · 2021: 4 · 2020: 3 · 2019: 2 · 2018: 2 · 2016: 4 · 2015: 2 · 2014: 1 · 2013: 2 · 2012: 3
FWCI
0.69
Type
journal article
Language
en
Open access
closed
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Locations
  • Journal of Neuroscience Methods (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
microwires, vacuum metallization, gold coating, platinum coating, peripheral nerve recording, electrical conductivity, mechanical properties
MeSH terms
Animals, Biocompatible Materials, Cats, Electric Conductivity, Electrodes, Implanted, Gold, Materials Testing, Metallurgy, Microelectrodes, Platinum, Polymers, Radial Nerve, Tensile Strength, Titanium, Tungsten, Pliability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Metallized polymer fibers as leadwires and intrafascicular microelectrodes. https://app.cochat.ai/papers/10.1016/s0165-0270(96)00111-2
The paper
McNaughton, T. G., & Horch, K. W. (1996). Metallized polymer fibers as leadwires and intrafascicular microelectrodes. Journal of Neuroscience Methods. https://doi.org/10.1016/s0165-0270(96)00111-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.