CoChat

Infrared tympanic thermometer can accurately measure the body temperature in children in an emergency room setting

Open access
Kocoglu, Hasan, Goksu, Sitki, Isik, Memet, Akturk, Zekeriya, Bayazit, Yildirim A · 2002 · International Journal of Pediatric Otorhinolaryngology
Cited by 76

The DOI matches its Crossref record.

Abstract

OBJECTIVE The objective in this study was to compare the accuracy of the tympanic membrane infrared thermometer with the other conventional temperature measurement options. METHODS One hundred and ten randomly selected pediatric patients who admitted to our emergency room were included in the study. Each child underwent simultaneous temperature measurement via rectum, axilla, and external auditory canal. The rectal and axillary measurements were performed using conventional mercury in glass thermometers. The aural measurement was performed using the non-contact infrared thermometer (Braun ThermoScan IRT 1020, Germany). RESULTS On aural measurement, the results of both ears as well as the first, second and third measurements were similar (P<0.01). The mean results of the axillary, rectal and tympanic temperature measurements were 37.46+/-1, 38.18+/-1, and 38.01+/-1.1, respectively. The mean axillary temperature was 0.72 degrees C lower than the mean rectal temperature, and 0.55 degrees C lower than the tympanic temperature. The difference between the mean tympanic and rectal temperatures was 0.17 degrees C. The results of measurements via rectum, axilla and ear were similar (P<0.01). CONCLUSION In conclusion, it is apparent that each of the temperature measurement options has some advantages and disadvantages. An optimal thermometer should have the following features; accurate temperature measurement; ease of application in a short while; safety and absence of potential risks; and tolerability by the patient. Since the aural infrared thermometer meets these criteria, its use in the routine clinical practice appears to be advantageous rather than or complementary to the conventional methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0165-5876(02)00129-5

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 18

  1. Cattaneo, 2000, The accuracy and precision of body temperature monitoring methods during regional and general anesthesia, Anesth. Analg., 90, 938, 10.1213/00000539-200004000-00030 · DOI
  2. Edge, 1993, The genius infrared tympanic thermometer, Anaesthesia, 48, 604, 10.1111/j.1365-2044.1993.tb07127.x · doi:10.1111/j.1365-2044.1993.tb07127.x
  3. Kenney, 1990, Evaluation of an infrared tympanic membrane thermometer in pediatric patients, Pediatrics, 85, 854, 10.1542/peds.85.5.854 · DOI
  4. Childs, 1999, Tympanic membrane temperature as a measure of core temperature, Arch. Dis. Child., 80, 262, 10.1136/adc.80.3.262 · DOI
  5. Erickson, 1993, Comparison of ear-based, bladder, oral, and axillary methods for core temperature measurement, Crit. Care Med., 21, 1528, 10.1097/00003246-199310000-00022 · DOI · Paper page
  6. Yoran, 1995, Measuring the accuracy of the infrared tympanic thermometer, J. Emerg. Med., 13, 617, 10.1016/0736-4679(95)00065-I · DOI
  7. Stavem, 1997, Accuracy of infrared ear thermometry in adult patients, Intensive Care Med., 23, 100, 10.1007/s001340050297 · DOI
  8. Irvin, 1999, Comparison of the oral thermometer versus the tympanic thermometer, Clin. Nurse Spec., 13, 85, 10.1097/00002800-199903000-00011 · doi:10.1097/00002800-199903000-00011
  9. Giuliano, 2000, Temperature measurement in critically ill adults: a comparison of tympanic and oral methods, Am. J. Crit. Care, 9, 254, 10.4037/ajcc2000.9.4.254 · DOI
  10. Bliss-Holtz, 1991, Determining cold-stress in full-term new-borns through temperature site comparisons, Schl. Inq. Nursing Pract., 5, 113, 10.1891/0889-7182.5.2.113 · doi:10.1891/0889-7182.5.2.113
  11. Holtzcloiw, 1993, Monitoring body temperature, AACN Clin. Issues, 4, 44, 10.1097/00044067-199302000-00005 · doi:10.1097/00044067-199302000-00005
  12. Jensen, 2000, Accuracy of digital tympanic, oral, axillary, and rectal thermometers compared with standard rectal mercury thermometers, Eur. J. Surg., 166, 848, 10.1080/110241500447218 · DOI · Paper page
  13. Valle, 2000, Infrared tympanic thermometry compared to mercury thermometers, Tidsskr. Nor. Laegeforen., 20, 15
  14. Bliss-Holtz, 1989, Comparison of rectal, axillary, and inguinal temperatures in full-term newborn infants, Nursing Res., 38, 85, 10.1097/00006199-198903000-00009 · doi:10.1097/00006199-198903000-00009
  15. Tomkinson, 1996, Tympanic thermometry and minor ear surgery (short communication), J. Laryngol. Otol., 110, 454, 10.1017/S002221510013395X · doi:10.1017/s002221510013395x
  16. Kahyaoglu, 1997, Effect of crying on infrared tympanic temperature measurement in pediatrics, Clin. Pediatr., 36, 487, 10.1177/000992289703600810 · doi:10.1177/000992289703600810
  17. Robb, 2001, Infrared transtympanic temperature measurement and otitis media with effusion, Int. J. Pediatr. Otorhinolaryngol., 59, 195, 10.1016/S0165-5876(01)00482-7 · doi:10.1016/s0165-5876(01)00482-7
  18. Freed, 1992, Lack of agreement of tympanic membrane temperature assessments with conventional methods in a private practice setting, Pediatrics, 89, 384, 10.1542/peds.89.3.384 · doi:10.1542/peds.89.3.384

Cited by

See all 76

Metadata

Authors
Kocoglu, H., Goksu, S., Isik, M., Akturk, Z., & Bayazit, Y. A.
Venue
International Journal of Pediatric Otorhinolaryngology
Publisher
Elsevier BV
Published
2002-08
Volume
65
Issue
1
Pages
39-43
ISSN
0165-5876 (ISSN-L)
OpenAlex
W2037287449
Cited by
76
References
0
FWCI
3.96
Type
journal article
Language
en
Open access
green
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Infrared tympanic thermometer can accurately measure the body temperature in children in an emergency room setting. https://app.cochat.ai/papers/10.1016/s0165-5876(02)00129-5
The paper
Kocoglu, H., Goksu, S., Isik, M., Akturk, Z., & Bayazit, Y. A. (2002). Infrared tympanic thermometer can accurately measure the body temperature in children in an emergency room setting. International Journal of Pediatric Otorhinolaryngology. https://doi.org/10.1016/s0165-5876(02)00129-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.