The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Recent developments in the design and application of screen-printed electrochemical sensors for biomedical, environmental and industrial analyses
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ferrocene-mediated enzyme electrode for amperometric determination of glucose
Cass, A. E. G., Davis, G., Francis, G. D., Hill, H. A. O., Aston, W. J., Higgins, I. J., Plotkin, E. V., Scott, L. D. L., & Turner, A. P. F. (1984) · Analytical Chemistry · doi:10.1021/ac00268a018 · Cited by 1,646
Degani, Y., & Heller, A. (1987) · The Journal of Physical Chemistry · doi:10.1021/j100290a001 · Cited by 574
Schuhmann, W., Ohara, T. J., Schmidt, H. L., & Heller, A. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00004a048 · Cited by 348
PEN-SIZED DIGITAL 30-SECOND BLOOD GLUCOSE METER
Matthews, D. R., Bown, E., Watson, A., Holman, R. R., Steemson, J., Hughes, S., & Scott, D. (1987) · The Lancet · doi:10.1016/s0140-6736(87)92802-9 · Cited by 300
Wang, J., & Tian, B. (1992) · Analytical Chemistry · doi:10.1021/ac00039a015 · Cited by 168
Printed amperometric sensor based on TCNQ and cholinesterase
Kulys, J. J., & D'Costa, E. J. (1991) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(91)87034-9 · Cited by 137
Newman, J. D., White, S. F., Tothill, I. E., & Turner, A. P. F. (1995) · Analytical Chemistry · doi:10.1021/ac00120a027 · Cited by 109
Wring, S. A., Hart, J. P., Bracey, L., & Birch, B. J. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)86418-1 · Cited by 100
Self-citationSilber, A., Hampp, N., & Schuhmann, W. W. (1996) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(96)88408-9 · Cited by 91
Sprules, S. D., Hart, J. P., Wring, S. A., & Pittson, R. W. (1995) · Analytica Chimica Acta · doi:10.1016/0003-2670(94)00565-4 · Cited by 74
Self-citation
Cited by
Sensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes
Ricci, F., & Palleschi, G. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.001 · Cited by 781
Patterning of controllable surface wettability for printing techniques
Tian, D., Song, Y., & Jiang, L. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35501b · Cited by 372
Bandodkar, A. J., Jeerapan, I., You, J.-M., Nuñez-Flores, R., & Wang, J. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04549 · Cited by 341
Wearable potentiometric ion sensors
Parrilla, M., Cuartero, M., & Crespo, G. A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.024 · Cited by 334
Zhang, W., Zhu, S., Luque, R., Han, S., Hu, L., & Xu, G. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00297d · Cited by 313
Metadata
- Authors
- Hart, J. P., & Wring, S. A.
- Venue
- TrAC Trends in Analytical Chemistry
- Publisher
- Elsevier BV
- Published
- 1997-02
- Volume
- 16
- Issue
- 2
- Pages
- 89-103
- ISSN
- 0165-9936 (ISSN-L)
- OpenAlex
- W2012635392
- Cited by
- 280
- References
- 13
- FWCI
- 9.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent developments in the design and application of screen-printed electrochemical sensors for biomedical, environmental and industrial analyses. https://app.cochat.ai/papers/10.1016/s0165-9936(96)00097-0
- The paper
- Hart, J. P., & Wring, S. A. (1997). Recent developments in the design and application of screen-printed electrochemical sensors for biomedical, environmental and industrial analyses. TrAC Trends in Analytical Chemistry. https://doi.org/10.1016/s0165-9936(96)00097-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.