Microbial analysis at the single-cell level: tasks and techniques
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Green fluorescent protein as a marker for gene expression
Chalfie, M., Tu, Y., Euskirchen, G., Ward, W. W., & Prasher, D. C. (1994) · Science · doi:10.1126/science.8303295 · Cited by 6,802 · cited 1×
“However, the stantial advance was made by Chalfie et al. (1994), technique becomes most useful when several assays who found that the gene for the green fluorescent are run in a single tube, using beads that can be protein from the jellyfish Aequorea could be used as discriminated from one another…”
BackgroundHandbook of fluorescent probes and research chemicals
Haugland, R. P. (1996) · Medical Entomology and Zoology · Cited by 2,793
Shapiro, H. M. (2003) · Wiley eBooks · doi:10.1002/0471722731 · Cited by 2,671
Self-citationUnderstanding, improving and using green fluorescent proteins
Cubitt, A. B., Heim, R., Adams, S. R., Boyd, A. E., Gross, L. A., & Tsien, R. Y. (1995) · Trends in Biochemical Sciences · doi:10.1016/s0968-0004(00)89099-4 · Cited by 1,349 · cited 1×
“…systems producing UV (350 and microscopy, scanning laser cytometry (Kamentsky et 356 nm) and violet (406–422 nm) light as well as al., 1997; Darzynkiewicz et al., 1999), and volu- blue (three lines near 470 nm), green (520 and 530 metric capillary cytometry (Dietz et al., 1996) are nm),…”
Cyanine dye labeling reagents: Sulfoindocyanine succinimidyl esters
Mujumdar, R. B., Ernst, L. A., Mujumdar, S. R., Lewis, C. J., & Waggoner, A. S. (1993) · Bioconjugate Chemistry · doi:10.1021/bc00020a001 · Cited by 884
Davey, H. M., & Kell, D. B. (1996) · Microbiological Reviews · doi:10.1128/mr.60.4.641-696.1996 · Cited by 879
A microfabricated fluorescence-activated cell sorter
Fu, A. Y., Spence, C., Scherer, A., Arnold, F. H., & Quake, S. R. (1999) · Nature Biotechnology · doi:10.1038/15095 · Cited by 878 · cited 1×
“Newly de- helium–neon (He–Ne) lasers emit as much as 50 veloped microfluidic flow cytometers (Fu et al., mW in the red region at 633 nm, and can also be 1999) may combine the best features of flow and made to emit green (543 nm), yellow (594 nm), and static cytometers; while their analysis rate is typical- orange (611…”
Advanced multiplexed analysis with the FlowMetrix system.
Fulton, R. J., McDade, R. L., Smith, P. L., Kienker, L. J., & Kettman, J. R. (1997) · PubMed · Cited by 704
Photon Upmanship: Why Multiphoton Imaging Is More than a Gimmick
Denk, W., & Svoboda, K. (1997) · Neuron · doi:10.1016/s0896-6273(00)81237-4 · Cited by 676 · cited 1×
“…the light, but emit discussed by van den Engh and Farmer (1992). fluorescence instead of transferring energy nonradia- In recent years, the technique of multiphoton tively to a different phycobiliprotein with appropriate excitation (Denk and Svoboda, 1997; Masters et al., spectral characteristics.”
Advanced multiplexed analysis with the FlowMetrixTM system
Fulton, R. J., McDade, R. L., Smith, P. L., Kienker, L. J., & Kettman, J. R. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.9.1749 · Cited by 650 · cited 1×
“Microdroplets, growth, and multiplex analysis size, color, or both; this is referred to as multiplex analysis (Fulton et al., 1997).”
Cited by
Xenobiotics shape the physiology and gene expression of the active human gut microbiome
Maurice, C. F., Haiser, H. J., & Turnbaugh, P. J. (2013) · Cell · doi:10.1016/j.cell.2012.10.052 · Cited by 811
Single-Cell Microbiology: Tools, Technologies, and Applications
Brehm-Stecher, B. F., & Johnson, E. A. (2004) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.68.3.538-559.2004 · Cited by 501
Effect of selected environmental and physico-chemical factors on bacterial cytoplasmic membranes
Denich, T. J., Beaudette, L. A., Lee, H., & Trevors, J. T. (2003) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(02)00155-0 · Cited by 439
Volkmer, B., & Heinemann, M. (2011) · PLoS ONE · doi:10.1371/journal.pone.0023126 · Cited by 351
Nanda, A. M., Thormann, K., & Frunzke, J. (2015) · Journal of Bacteriology · doi:10.1128/jb.02230-14 · Cited by 319
Application of flow cytometry to industrial microbial bioprocesses
Díaz, M., Herrero, M., García, L. A., & Quirós, C. (2010) · Biochemical Engineering Journal · doi:10.1016/j.bej.2009.07.013 · Cited by 292
Amor, K. B., Breeuwer, P., Verbaarschot, P., Rombouts, F. M., Akkermans, A. D. L., De Vos, W. M., & Abee, T. (2002) · Applied and Environmental Microbiology · doi:10.1128/aem.68.11.5209-5216.2002 · Cited by 284
Harz, M., Rösch, P., & Popp, J. (2009) · Cytometry Part A · doi:10.1002/cyto.a.20682 · Cited by 278
Ben-Amor, K., Heilig, H., Smidt, H., Vaughan, E. E., Abee, T., & de Vos, W. M. (2005) · Applied and Environmental Microbiology · doi:10.1128/aem.71.8.4679-4689.2005 · Cited by 233
“Membrane integrity is measured by the capacity of cells to exclude impermeant dyes, of which PI has been the most widely used (21, 43).”
BackgroundRodriguez, E., Seguer, J., Rocabayera, X., & Manresa, A. (2004) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2004.02207.x · Cited by 193
“During the last few years, a large number of fluorescentbased assays for evaluating bacterial viability, membrane depolarization, enzyme activity or the physiological state of bacteria have appeared (Lebaron et al. 1998; Shapiro 2000).”
BackgroundFlow Cytometry: The Next Revolution
Robinson, J. P., Ostafe, R., Iyengar, S. N., Rajwa, B., & Fischer, R. (2023) · Cells · doi:10.3390/cells12141875 · Cited by 180
Luo, J., Chen, Y., & Feng, L. (2016) · Environmental Science & Technology · doi:10.1021/acs.est.6b00003 · Cited by 180
Kim, D.-K., Kim, S.-J., & Kang, D.-H. (2017) · Food Research International · doi:10.1016/j.foodres.2017.04.009 · Cited by 175
Di Giorgio, C., Delmas, F., Ollivier, E., Elias, R., Balansard, G., & Timon-David, P. (2004) · Experimental Parasitology · doi:10.1016/j.exppara.2004.04.002 · Cited by 160
Applications of Flow Cytometry to Characterize Bacterial Physiological Responses
Ambriz-Aviña, V., Contreras-Garduño, J. A., & Pedraza-Reyes, M. (2014) · BioMed Research International · doi:10.1155/2014/461941 · Cited by 159
“Other studies have succeeded in employing fluorescent probes to measure the efficiency of new antibacterial drugs [12, 56, 57].”
BackgroundMethodInfluential
Metadata
- Authors
- Shapiro, H. M.
- Venue
- Journal of Microbiological Methods
- Publisher
- Elsevier BV
- Published
- 2000-09
- Volume
- 42
- Issue
- 1
- Pages
- 3-16
- ISSN
- 0167-7012 (ISSN-L)
- OpenAlex
- W2027761702
- Cited by
- 187
- References
- 34
- FWCI
- 3.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.