Phase inversion dynamics of PLGA solutions related to drug delivery
The DOI matches its Crossref record; 35 of the 39 references it cites were found in a registry or an index.
Abstract
Dark ground optical microscopy, electron microscopy, and high performance liquid chromatography (HPLC) have been used to quantify the effects of formulation changes on the phase inversion dynamics and in vitro drug release properties of a PLGA-based drug delivery system. Gel growth rates and water influx rates are determined from plots of the square of the respective front motion with time. Results show that additives that accelerate the solution gelation rate at constant morphology result in high initial release rates. Conversely, additives that slow the rate of gelation dramatically reduce the initial drug release rate and lead to a more dense sponge-like morphology. Moreover, the phase inversion dynamics and morphology are the same regardless of whether the solutions are quenched with water, a PBS buffer solution or horse serum.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The processing parameters including polymer concentration, quenching temperature, quenching time and solvent composition affect the morphology and size of the microspheres [41–43].”
From Poly Lactic-co-Glycolic Acid (PLGA) as Biodegradable Controlled Drug Delivery Carrier (2011) · cites this paper as [43]
Citations
Cites
Basic principles of membrane technology
(1992) · Choice Reviews Online · doi:10.5860/choice.29-3919 · Cited by 4,115
Basic Principles of Membrane Technology
Mulder, M. (1991) · Springer eBooks · doi:10.1007/978-94-017-0835-7 · Cited by 1,137
The formation mechanism of phase inversion membranes
Strathmann, H., & Kock, K. (1977) · Desalination · doi:10.1016/s0011-9164(00)88244-2 · Cited by 661
The formation mechanism of asymmetric membranes
Strathmann, H., Kock, K., Amar, P., & Baker, R. W. (1975) · Desalination · doi:10.1016/s0011-9164(00)82092-5 · Cited by 661
Microstructures in phase inversion membranes. Part 2. The role of a polymeric additive
Boom, R. M., Wienk, I. M., van den Boomgaard, T., & Smolders, C. A. (1992) · Journal of Membrane Science · doi:10.1016/0376-7388(92)80135-7 · Cited by 454
Yilmaz, L., & McHugh, A. J. (1986) · Journal of Applied Polymer Science · doi:10.1002/app.1986.070310404 · Cited by 253
Self-citationPoly(lactide-co-glycolide) decomposition kinetics in vivo and in vitro
Kenley, R. A., Lee, M. O., Mahoney, T. R., & Sanders, L. M. (1987) · Macromolecules · doi:10.1021/ma00176a012 · Cited by 241
McKelvey, S. (1996) · Journal of Membrane Science · doi:10.1016/0376-7388(95)00197-2 · Cited by 231
Mass transfer modeling of asymmetric membrane formation by phase inversion
Tsay, C. S., & Mchugh, A. J. (1990) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.1990.090280810 · Cited by 229
Self-citationZero-Order Controlled-Release Polymer Matrices for Micro- and Macromolecules
Hsieh, D. S. T., Rhine, W. D., & Langer, R. (1983) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600720105 · Cited by 214
Research works printed but not linked: 1
- R.M. Barrer, Diffusion and permeation in heterogenous media, in: J. Crank, G.S. Park (Eds.), Diffusion in Polymers, Academic Press, London, 1968.
Cited by
Poly Lactic-co-Glycolic Acid (PLGA) as Biodegradable Controlled Drug Delivery Carrier
Makadia, H. K., & Siegel, S. J. (2011) · Polymers · doi:10.3390/polym3031377 · Cited by 4,816
“The processing parameters including polymer concentration, quenching temperature, quenching time and solvent composition affect the morphology and size of the microspheres [41–43].”
BackgroundPLGA: a Unique Polymer for Drug Delivery
Kapoor, D. N., Bhatia, A., Kaur, R., Sharma, R., Kaur, G., & Dhawan, S. (2015) · Therapeutic Delivery · doi:10.4155/tde.14.91 · Cited by 609
In situ forming parenteral drug delivery systems: an overview
Packhaeuser, C. B., Schnieders, J., Oster, C. G., & Kissel, T. (2004) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2004.03.003 · Cited by 413
In situ forming implants — an attractive formulation principle for parenteral depot formulations
Kempe, S., & Mäder, K. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.04.016 · Cited by 323
“Additionally the required special sample preparation may lead to artifacts [91,104,113].”
BackgroundFabrication of PLG microspheres with precisely controlled and monodisperse size distributions
Berkland, C., Kim, K. (., & Pack, D. W. (2001) · Journal of Controlled Release · doi:10.1016/s0168-3659(01)00289-9 · Cited by 336
Parent, M., Nouvel, C., Koerber, M., Sapin, A., Maincent, P., & Boudier, A. (2013) · Journal of Controlled Release · doi:10.1016/j.jconrel.2013.08.024 · Cited by 263
“This approach has been extensively studied [19,23,26,41,79,80].”
BackgroundMethodInfluentialLu, Y., Cheng, D., Niu, B., Wang, X., Wu, X., & Wang, A. (2023) · Pharmaceuticals · doi:10.3390/ph16030454 · Cited by 251
Clinical translation of long-acting drug delivery formulations
Li, W., Tang, J., Lee, D., Tice, T. R., Schwendeman, S. P., & Prausnitz, M. R. (2022) · Nature Reviews Materials · doi:10.1038/s41578-021-00405-w · Cited by 223
Physicochemical aspects of drug delivery and release from polymer-based colloids
Yang, L., & Alexandridis, P. (2000) · Current Opinion in Colloid & Interface Science · doi:10.1016/s1359-0294(00)00046-7 · Cited by 242
Thermogels: In Situ Gelling Biomaterial
Liow, S. S., Dou, Q., Kai, D., Karim, A. A., Zhang, K., Xu, F., & Loh, X. J. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00515 · Cited by 231
Park, J., Jin, C., Lee, S., Kim, J., & Choi, H. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900213 · Cited by 201
Long-term delivery of protein therapeutics
Vaishya, R., Khurana, V., Patel, S., & Mitra, A. K. (2015) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2015.961420 · Cited by 193
“These factors are again dependent on the polymer type, concentration and molecular weight, solvent system, polymer crystallinity and additives [28-32].”
BackgroundPoly(lactic-co-glycolic acid) microsphere production based on quality by design: a review
Hua, Y., Su, Y., Zhang, H., Liu, N., Wang, Z., Gao, X., Gao, J., & Zheng, A. (2021) · Drug Delivery · doi:10.1080/10717544.2021.1943056 · Cited by 175
“For instance, a lower proportion of lactide than galactide in the copolymer may decrease the Tg (Graham et al., 1999), which is an indicator of the chain structure rigidity and is generally above 37 C.”
BackgroundPhase inversion dynamics of PLGA solutions related to drug delivery
Brodbeck, K. J., DesNoyer, J. R., & McHugh, A. J. (1999) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00159-5 · Cited by 174
Self-citationSolvent induced phase inversion-based in situ forming controlled release drug delivery implants
Thakur, R. R. S., McMillan, H. L., & Jones, D. S. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2013.12.020 · Cited by 165
Ultra-long-acting tunable biodegradable and removable controlled release implants for drug delivery
Benhabbour, S. R., Kovářová, M., Jones, C. F., Copeland, D. J., Shrivastava, R., Swanson, M. D., Sykes, C., Ho, P. T., Cottrell, M. L., Sridharan, A. N., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-12141-5 · Cited by 158
Injectable implants for the sustained release of protein and peptide drugs
Agarwal, P., & Rupenthal, I. D. (2013) · Drug Discovery Today · doi:10.1016/j.drudis.2013.01.013 · Cited by 156
A novel in situ forming drug delivery system for controlled parenteral drug delivery
Kranz, H., & Bodmeier, R. A. (2006) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2006.09.033 · Cited by 147
Effect of injection site on in situ implant formation and drug release in vivo
Patel, R. B., Solorio, L., Wu, H., Krupka, T. M., & Exner, A. A. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.08.020 · Cited by 143
“Previous studies by Graham et al, have shown that in vitro implant formation examined using dark ground imaging (DGI) correlated to observed drug release from differing ISFI formulations with slower forming implants releasing drug slower than faster forming implants [5].”
BackgroundResultInfluentialLuan, X., & Bodmeier, R. A. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.10.005 · Cited by 141
PLGA-Based Micro/Nanoparticles: An Overview of Their Applications in Respiratory Diseases
Guo, X., Xu, Z., Zhou, Z., Gu, Y., Zheng, H., Wang, X., Wang, G., Xu, C., & Wang, F. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24054333 · Cited by 129
Tang, Y., & Singh, J. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2008.01.053 · Cited by 130
Drug release from in situ forming implants and advances in release testing
Wang, X., & Burgess, D. J. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.113912 · Cited by 122
Biodegradable Injectable In Situ Depot‐Forming Drug Delivery Systems
Chitkara, D., Shikanov, A., Kumar, N., & Domb, A. J. (2006) · Macromolecular Bioscience · doi:10.1002/mabi.200600129 · Cited by 112
Kranz, H., & Bodmeier, R. A. (2008) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2008.03.004 · Cited by 126
“It is well known that different polymer precipitation rates lead to different surface properties which affect the drug release rates (Graham et al., 1999).”
BackgroundInfluentialSustained Release of Human Growth Hormone from PLGA Solution Depots
Brodbeck, K. J., Pushpala, S., & McHugh, A. J. (1999) · Pharmaceutical Research · doi:10.1023/a:1018943107688 · Cited by 110
Self-citationGad, H. A., El-Nabarawi, M. A., & ElHady, S. S. A. (2008) · AAPS PharmSciTech · doi:10.1208/s12249-008-9126-9 · Cited by 105
Controlled delivery of testosterone from smart polymer solution based systems: In vitro evaluation
Chen, S., & Singh, J. (2005) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2005.02.023 · Cited by 112
Role of in vitro release models in formulation development and quality control of parenteral depots
Larsen, C., Larsen, S. W., Jensen, H. M., Yaghmur, A., & Østergaard, J. (2009) · Expert Opinion on Drug Delivery · doi:10.1517/17425240903307431 · Cited by 114
Panigrahi, D., Sahu, P. K., Swain, S., & Verma, R. K. (2021) · SN Applied Sciences · doi:10.1007/s42452-021-04609-1 · Cited by 109
“It has also been reported that the Tg of PLGA decreases under the wet condition, which leads to the plasticization of the polymer matrix and lessening in mechanical properties of PLGA [63, 67, 68].”
BackgroundLiu, Q., Zhang, H., Zhou, G., Xie, S.-B., Zou, H. L., Yu, Y., Li, G., Sun, D., Zhang, G., Lü, Y., et al. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.07.015 · Cited by 96
The role of polymer membrane formation in sustained release drug delivery systems
McHugh, A. J. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.09.038 · Cited by 96
“In situ measurements of the water diffusion and solution gelation rates, as well as water take-up rates, parallel these trends [6,9].”
Self-citationLuan, X.-L., Skupin, M., Siepmann, J., & Bodmeier, R. A. (2006) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2006.06.004 · Cited by 114
Astaneh, R., Erfan, M., Moghimi, H., & Mobedi, H. (2008) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21415 · Cited by 91
Sustained-release injectables formed in situ and their potential use for veterinary products
Matschke, C., Isele, U., van Hoogevest, P., & Fahr, A. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00266-3 · Cited by 105
Kinetics of solvent extraction/evaporation process for PLGA microparticle fabrication
Katou, H., Wandrey, A. J., & Gander, B. A. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2008.08.015 · Cited by 87
Kempe, S., Metz, H., & Mäder, K. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.06.006 · Cited by 88
“McHugh and co-workers developed a dark ground video imaging technique that enables to visualise diffusion, liquid–liquid phase separations and gel formation processes and quantified the phase inversion dynamics of several PLGA solutions [18,19].”
BackgroundCamargo, J. A., Sapin‐Minet, A., Nouvel, C., Daloz, D., Léonard, M., Bonneaux, F., Six, J., & Maincent, P. (2012) · Drug Development and Industrial Pharmacy · doi:10.3109/03639045.2012.660952 · Cited by 87
Noninvasive characterization of in situ forming implants using diagnostic ultrasound
Solorio, L., Babin, B. M., Patel, R. B., Mach, J., Azar, N., & Exner, A. A. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.01.001 · Cited by 89
“Another common technique for imaging in situ forming implants is scanning electron microscopy [3,16,17,20,22,23].”
BackgroundMethodInfluentialSustained delivery of human growth hormone from a novel gel system: SABERTM
Okumu, F. W., Dao, L. N., Fielder, P. J., Dybdal, N. O., Brooks, D. A., Sane, S. P., & Cleland, J. L. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00174-6 · Cited by 87
“These data also suggested that the presence of PLA at the surface of the SABER rhGH depot may reduce the accessibility of the protein to the depot/water interface causing release governed by protein diffusion and degradation of SAIB leading to a continuous release of native rhGH with minimal initial release [21,22].”
BackgroundAhmed, T. A., Ibrahim, H. M., Samy, A. M., Kassem, A. A., Nutan, M. T. H., & Hussain, M. D. (2014) · AAPS PharmSciTech · doi:10.1208/s12249-014-0101-3 · Cited by 84
Luan, X., & Bodmeier, R. A. (2005) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2005.09.002 · Cited by 77
“A decrease in the drug release from in situ forming implant systems with the increasing polymer concentration was already reported (Graham et al., 1999; Lambert and Peck, 1995).”
BackgroundThe effect of Pluronic on the protein release kinetics of an injectable drug delivery system
DesNoyer, J. R., & McHugh, A. J. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00293-6 · Cited by 76
Self-citationDrug release from injectable depots: two different in vitro mechanisms
Wang, L., Venkatraman, S. S., & Kleiner, L. W. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.06.021 · Cited by 74
“Several formulations have been studied using polymers such as polylactide, poly (lactide-co-glycolide) (PLGA), or poly (q-caprolactone) [15] in solvents such as N-methyl-2-pyrrolidone (NMP) [5,6,10,14], dimethyl sulfoxide (DMSO) [4,10,16], glycofurol se 99 (2004) 207–216”
MethodWang, L., Wang, A., Zhao, X., Liu, X., Wang, D., Sun, F., & Li, Y. (2012) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2012.02.015 · Cited by 72
Patel, R. B., Carlson, A. N., Solorio, L., & Exner, A. A. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32724 · Cited by 71
In Vitro and In Vivo Drug Release from a Novel In Situ Forming Drug Delivery System
Kranz, H., Yilmaz, E., Brazeau, G. A., & Bodmeier, R. A. (2007) · Pharmaceutical Research · doi:10.1007/s11095-007-9478-y · Cited by 73
“The high initial drug release from in situ forming implants based on water miscible solvents is in good agreement with the literature (14).”
BackgroundResultRedefining the importance of polylactide-co-glycolide acid (PLGA) in drug delivery
Chavan, Y. R., Tambe, S. M., Jain, D. D., Khairnar, S. V., & Amin, P. D. (2021) · Annales Pharmaceutiques Françaises · doi:10.1016/j.pharma.2021.11.009 · Cited by 77
Effect of implant formation on drug release kinetics of in situ forming implants
Suh, M. S., Kastellorizios, M., Tipnis, N. P., Zou, Y., Wang, Y., Choi, S. H., & Burgess, D. J. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.120105 · Cited by 68
Kempe, S., Metz, H., Pereira, P. G. C., & Mäder, K. (2009) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2009.06.008 · Cited by 72
“developed a darkground video imaging technique to visualise and quantify the phase inversion dynamics of several PLGA solutions [12,13].”
BackgroundCosolvent Effects on the Drug Release and Depot Swelling in Injectable In situ Depot-Forming Systems
Liu, H., & Venkatraman, S. S. (2012) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23065 · Cited by 66
Roberge, C., Cros, J.-M., Serindoux, J., Cagnon, M.-E., Samuel, R., Vrlinič, T., Berto, P., Rech, A., Richard, J., & López‐Noriega, A. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.01.022 · Cited by 66
Development of PLGA-Based Injectable Delivery Systems For Hydrophobic Fenretinide
Wischke, C., Zhang, Y., Mittal, S., & Schwendeman, S. P. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0202-y · Cited by 68
“, efflux of NMP as polymer carrier solvent and influx of water as non-solvent to the polymer (35).”
BackgroundKrebs, M. D., Sutter, K. A., Lin, A., Guldberg, R. E., & Alsberg, E. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.04.035 · Cited by 67
“As the water-insoluble PLGA comes into contact with the aqueous solution, it precipitates by phase inversion into a nonporous scaffold [25,26].”
BackgroundKang, J. S., & Lee, Y. M. (2002) · Journal of Applied Polymer Science · doi:10.1002/app.10569 · Cited by 64
Bakhshi, R., Vasheghani‐Farahani, E., Mobedi, H., Jamshidi, A., & Khakpour, M. (2006) · Polymers for Advanced Technologies · doi:10.1002/pat.717 · Cited by 63
Puricelli, C., Gigliotti, C. L., Stoppa, I., Sacchetti, S., Pantham, D., Scomparin, A., Rolla, R., Pizzimenti, S., Dianzani, U., Boggio, E. M., et al. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15061772 · Cited by 66
“Nevertheless, other techniques, such as solvent diffusion [25] or phase-inversion [26], can be used to avoid exposure of the active molecules to harsh conditions (high energy, a potential increase of temperature, etc.”
BackgroundSolorio, L., Olear, A. M., Hamilton, J., Patel, R. B., Beiswenger, A. C., Wallace, J. E., Zhou, H., & Exner, A. A. (2012) · Theranostics · doi:10.7150/thno.4181 · Cited by 65
“Since the implants are initially a liquid solution, drug loading is performed simply through the addition of a powder form of the drug into the polymer/solvent mixture [5, 10, 11, 13, 17-21].”
BackgroundInfluentialDrug-eluting polymer implants in cancer therapy
Exner, A. A., & Saidel, G. M. (2008) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.5.7.775 · Cited by 71
“The dynamics of the phaseinversion process are directly related to the drug-release dynamics; for example, when the polymer solution is injected into fatty versus highly vascularized tissues of clearly different water content, the rate of phase inversion can be altered and lead to significant variation in drug release…”
BackgroundEngineered therapeutic proteins for sustained-release drug delivery systems
Nguyen, T. T. K., Pham, K., & Yook, S. (2023) · Acta Biomaterialia · doi:10.1016/j.actbio.2023.09.018 · Cited by 60
Burst Release from In Situ Forming PLGA-Based Implants: 12 Effectors and Ways of Correction
Бахрушина, Е. О., Sakharova, P. S., Konogorova, P. D., Pyzhov, V. S., Kosenkova, S. I., Bardakov, A. I., Zubareva, I. M., Krasnyuk, I. I., & Krasnyuk, I. I. (2024) · Pharmaceutics · doi:10.3390/pharmaceutics16010115 · Cited by 63
“To accelerate the release of active ingredients, substances such as mannitol [70] and polyvinylpyrrolidone [71] should be added to the polymer-based system to enhance the interface and diffusion.”
BackgroundEffect of additives on the release of a model protein from PLGA microspheres
Kang, F., & Singh, J. (2001) · AAPS PharmSciTech · doi:10.1007/bf02830570 · Cited by 69
Structure formation in injectable poly(lactide–co-glycolide) depots
Wang, L., Kleiner, L. W., & Venkatraman, S. S. (2003) · Journal of Controlled Release · doi:10.1016/s0168-3659(03)00198-6 · Cited by 55
Lin, X., Yang, S., Gou, J., Zhao, M., Zhang, Y. X., Qi, N., He, H., Cai, C., Tang, X., & Guo, P. (2011) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-011-4521-2 · Cited by 53
“Ternary phase diagrams can characterize the phase inversion of matrix solutions, and the interactions among matrix, solvent and buffer solution (non-solvent) [18].”
BackgroundLuan, X., & Bodmeier, R. A. (2006) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2005.12.010 · Cited by 53
Mechanistic analysis of PLGA/HPMC-based in-situ forming implants for periodontitis treatment
Do, M. P., Neut, C., Metz, H., Delcourt, E., Siepmann, J., Mäder, K., & Siepmann, F. (2015) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2015.05.018 · Cited by 53
Leconet, W., Liu, H., Guo, M., Lamer-Déchamps, S. L., Molinier, C., Kim, S., Vrlinič, T., Oster, M., Liu, F., Navarro, V., et al. (2018) · Molecular Cancer Therapeutics · doi:10.1158/1535-7163.mct-17-1138 · Cited by 47
“In this particular study, copolymers were dissolved in tripropionin, a carbon C3 small-chain triglyceride similar to triacetin, which has been used in several in situ forming gel studies (39, 40), to obtain a viscous injectable solution.”
MethodIn situ forming implant for controlled delivery of an anti-HIV fusion inhibitor
Kapoor, D. N., Katare, O. P., & Dhawan, S. (2012) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2012.01.005 · Cited by 47
Li, Z., Mu, H., Larsen, S. W., Jensen, H. M., & Østergaard, J. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2021.121183 · Cited by 47
“After exposure to an aqueous environment, the polymeric solution separates into two phases, a polymer-lean and a polymer-rich phase (Graham et al., 1999; Parent et al., 2013).”
BackgroundResultControlled release of a model protein lysozyme from phase sensitive smart polymer systems
Singh, S., & Singh, J. (2003) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2003.11.010 · Cited by 46
Asenapine maleate in situ forming biodegradable implant: An approach to enhance bioavailability
Avachat, A. M., & Kapure, S. S. (2014) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2014.10.006 · Cited by 46
Membrane formation by dry-cast process
Altınkaya, S. A., Yenal, H., & Ozbas, B. (2004) · Journal of Membrane Science · doi:10.1016/j.memsci.2004.10.008 · Cited by 45
Juvekar, S., & Kathpalia, H. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.02.022 · Cited by 42
Ma, D., & McHugh, A. J. (2007) · Journal of Membrane Science · doi:10.1016/j.memsci.2007.04.013 · Cited by 41
Self-citationHernandez, C., Gawlik, N., Goss, M., Zhou, H., Jeganathan, S., Gilbert, D., & Exner, A. A. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.10.009 · Cited by 40
“Although only a few studies have been done to elucidate the effects of these bathside components [11,12], none of them can account for the drastic differences in release profiles that lead to the poor IVIVC.”
Chhabra, S., Sachdeva, V., & Singh, S. (2007) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2007.04.034 · Cited by 40
Drug delivery systems: polymers and drugs monitored by capillary electromigration methods
Simó, C., Cifuentes, A., & Gallardo, A. (2003) · Journal of Chromatography B · doi:10.1016/s1570-0232(03)00430-6 · Cited by 40
Solorio, L., & Exner, A. A. (2015) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24673 · Cited by 39
Phaechamud, T., Senarat, S., Puyathorn, N., & Praphanwittaya, P. (2018) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2018.11.098 · Cited by 40
Schoenhammer, K., Petersen, H., Guethlein, F., & Göpferich, A. M. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2008.12.019 · Cited by 39
Kim, M., Johnson, C. E., Schmalstig, A. A., Annis, A., Wessel, S. E., Horn, B. V., Schauer, A. P., Exner, A. A., Stout, J. E., Hafner, R., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-32043-3 · Cited by 38
Antimicrobial in-situ forming gels based on bleached shellac and different solvents
Phaechamud, T., & Setthajindalert, O. (2018) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2018.05.035 · Cited by 38
Development of an in situ forming PLGA drug delivery system
Körber, M., & Bodmeier, R. A. (2008) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2008.07.007 · Cited by 38
Injectable, in situ forming poly(propylene fumarate)‐based ocular drug delivery systems
Ueda, H., Hacker, M. C., Haesslein, A., Jo, S., Ammon, D. M., Borazjani, R. N., Künzler, J., Salamone, J. C., & Mikos, A. G. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31226 · Cited by 41
Kılıçarslan, M., Körber, M., & Bodmeier, R. A. (2013) · Drug Development and Industrial Pharmacy · doi:10.3109/03639045.2013.873449 · Cited by 39
Zare, M., Mobedi, H., Barzin, J., Mivehchi, H., Jamshidi, A., & Mashayekhi, R. (2007) · Journal of Applied Polymer Science · doi:10.1002/app.27520 · Cited by 36
Sun, Y., Jensen, H. M., Petersen, N. J., Larsen, S. W., & Østergaard, J. (2017) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2017.11.065 · Cited by 36
Packhaeuser, C. B., & Kissel, T. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.08.004 · Cited by 39
Dermal and Transdermal Drug Delivery
Watkinson, A. C. (2008) · CRC Press eBooks · doi:10.3109/9781420045260-21 · Cited by 34
Solorio, L., Olear, A. M., Zhou, H., Beiswenger, A. C., & Exner, A. A. (2012) · Drug Delivery and Translational Research · doi:10.1007/s13346-011-0054-y · Cited by 37
“Therefore, monitoring the phase inversion dynamics provides insight into the underlying implant microstructure and release behavior of the depot [28].”
Poly(ethyleneglycol) 500 Dimethylether as Novel Solvent for Injectable In Situ Forming Depots
Schoenhammer, K., Petersen, H., Guethlein, F., & Göpferich, A. M. (2009) · Pharmaceutical Research · doi:10.1007/s11095-009-9969-0 · Cited by 33
A model for drug release from fast phase inverting injectable solutions
Raman, C., & McHugh, A. J. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.09.022 · Cited by 35
Self-citationAdvances in image-guided intratumoral drug delivery techniques
Solorio, L., Patel, R. B., Wu, H., Krupka, T. M., & Exner, A. (2010) · Therapeutic delivery · doi:10.4155/tde.10.20 · Cited by 34
DesNoyer, J. R., & McHugh, A. J. (2001) · Journal of Controlled Release · doi:10.1016/s0168-3659(00)00354-0 · Cited by 32
Self-citationThe Effect of Additives on the Behavior of Phase Sensitive In Situ Forming Implants
Solorio, L., Sundarapandiyan, D., Olear, A. M., & Exner, A. A. (2015) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24558 · Cited by 32
A PROLONGED RELEASE PARENTERAL DRUG DELIVERY SYSTEM - AN OVERVIEW
Bari, H. C. (2010) · Cited by 51
Janagam, D. R., Wang, L., Ananthula, S., Johnson, J. R., & Lowe, T. L. (2016) · Pharmaceutics · doi:10.3390/pharmaceutics8030028 · Cited by 32
Sutter, D., Dzhonova, D. V., Prost, J., Bovet, C., Banz, Y., Rahnfeld, L., Leroux, J., Rieben, R., Vögelin, E., Plock, J. A., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-45759-y · Cited by 30
Prabhu, S. V., Tran, L. P., & Betageri, G. V. (2005) · Drug Delivery · doi:10.1080/10717540590968873 · Cited by 34
Phaechamud, T., Mahadlek, J., & Tuntarawongsa, S. (2017) · Journal of Pharmaceutical Investigation · doi:10.1007/s40005-017-0340-x · Cited by 28
Metadata
- Authors
- Graham, P. D., Brodbeck, K. J., & McHugh, A. J.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- Corresponding author
- McHugh, A.J.
- Venue
- Journal of Controlled Release
- Publisher
- Elsevier BV
- Published
- 1999-03
- Volume
- 58
- Issue
- 2
- Pages
- 233-245
- ISSN
- 0168-3659 (ISSN-L)
- OpenAlex
- W2003429874
- Cited by
- 222
- References
- 39
- Citations by year
- 2026: 7 · 2025: 6 · 2024: 3 · 2023: 8 · 2022: 7 · 2021: 10 · 2020: 9 · 2019: 9 · 2018: 5 · 2017: 13 · 2016: 9 · 2015: 12 · 2014: 11 · 2013: 11 · 2012: 11
- FWCI
- 1.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Controlled Release (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advanced Drug Delivery Systems
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Surfactants and Colloidal Systems
- Keywords
- PLGA, phase inversion, drug delivery systems, gelation rate, water inflow, drug release kinetics, sponge morphology, formulation additives, polymer solutions, controlled release
- MeSH terms
- Polylactic Acid-Polyglycolic Acid Copolymer, Buffers, Chromatography, High Pressure Liquid, Diffusion, Gels, Microscopy, Electron, Muramidase, Pharmaceutic Aids, Polyglycolic Acid, Polymers, Povidone, Proteins, Triacetin, Water, Drug Delivery Systems, Lactic Acid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.