The design and testing of a force feedback dental simulator
The DOI matches its Crossref record; 18 of the 22 references it cites were found in a registry or an index.
Abstract
The Iowa Dental Surgical Simulator is a haptic simulator to train dental students in the haptic skills of dentistry. The initial design emphasizes the detection of carious lesions. This work describes the software and implementation of the prototype system, the design tradeoffs' and the technical issues associated with haptic and graphics subsystems. The work also describes the current system performance, including a formal evaluation by practicing dentists and performance measures. A discussion of the limitations of the current system is followed by an analysis of opportunities to improve the quality of the simulator. The results should be of interest to designers of medical haptic simulation systems and other simulation designers.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The Systematic Design of Instruction
Chang, S. L. (2006) · Educational Technology Research and Development · doi:10.1007/s11423-006-9606-0 · Cited by 2,588
The systematic design of instruction
Dick, W., Carey, L. M., & Carey, J. O. (1978) · Cited by 2,225
The PHANToM Haptic Interface: A Device for Probing Virtual Objects
Massie, T. H., & Salisbury, J. K. (1994) · Dynamic Systems and Control: Volume 1 — Control Theory/Methodology; Robust Control; Applied Nonlinear Control Systems; QFT Designs in Industrial, Government, Academic Settings; Robot Control; Impedance Planning for Robotics; Haptic Interfaces for Virtual Environment/Teleoperator Systems; Intelligent Control Systems; Intelligent Process Control; Neural Networks · doi:10.1115/imece1994-0452 · Cited by 1,372 · cited 1×
“Many researchers are interested in using haptic feedback devices to enhance their virtual environment research because simulating touch in virtual worlds has led to increased performance in training simulators [1–3].”
BackgroundA constraint-based god-object method for haptic display
Zilles, C. B., & Salisbury, J. K. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525876 · Cited by 819 · cited 2×
“Zilles [13] reports that ‘‘most users tend to use less than 5 N of force’’ when exploring virtual environments.”
BackgroundFactors affecting the Z-Width of a haptic display
Colgate, J. E., & Brown, J. M. (2002) · Proceedings of the 1994 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1994.351077 · Cited by 635 · cited 1×
“The haptic interaction between a point object and a virtual wall has been investigated by a number of researchers [7–9].”
BackgroundHaptics in virtual environments: Taxonomy, research status, and challenges
Srinivasan, M. A., & Basdogan, C. (1997) · Computers & Graphics · doi:10.1016/s0097-8493(97)00030-7 · Cited by 559
Issues in the haptic display of tool use
Colgate, J. E., Stanley, M. C., & Brown, J. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525875 · Cited by 404 · cited 4×
“An example of such a solution might be the Phantom (SensAble Technologies), which provides forces along the x, y, and z axes as well as passive degrees of freedom for roll, pitch and yaw.”
BackgroundInfluentialPhantom-based haptic interaction with virtual objects
Salisbury, J. K., & Srinivasan, M. A. (1997) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.1997.1626171 · Cited by 230
Salcudean, S. E., & Vlaar, T. D. (1997) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.2801204 · Cited by 178
The dynamics and control of a haptic interface device
Kazerooni, H., & Her, M.-G. (1994) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.313096 · Cited by 115 · cited 1×
“Kazerooni and Her [10] developed a sophisticated analysis that accounts for the dynamics of the human arm and its relationship with the haptic devices.”
BackgroundPerceptual decomposition of virtual haptic surfaces
Rosenberg, L. B., & Adelstein, B. D. (1993) · doi:10.1109/vrais.1993.378264 · Cited by 92 · cited 1×
“The haptic interaction between a point object and a virtual wall has been investigated by a number of researchers [7–9].”
BackgroundStability and Performance of Haptic Displays: Theory and Experiments
Adams, R. J., Moreyra, M. R., & Hannaford, B. (1998) · Dynamic Systems and Control · doi:10.1115/imece1998-0259 · Cited by 89 · cited 1×
“[14] virtual coupling network, also require update rates on the order of 1 kHz.”
BackgroundForce feedback for surgical simulation
Chen, E., & Marcus, B. A. (1998) · Proceedings of the IEEE · doi:10.1109/5.662877 · Cited by 71
Real-Time Impulse-Based Simulation of Rigid Body Systems for Haptic Display
Chang, B., & Colgate, J. E. (1997) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece1997-0389 · Cited by 63 · cited 2×
“Chang and Colgate [4] report that their unpublished experiments show that haptic devices require an update rate of 500 Hz–1 kHz.”
BackgroundA tangible goal for 3D modeling
Massie, T. H. (1998) · IEEE Computer Graphics and Applications · doi:10.1109/38.674973 · Cited by 57 · cited 1×
“Many researchers are interested in using haptic feedback devices to enhance their virtual environment research because simulating touch in virtual worlds has led to increased performance in training simulators [1–3].”
BackgroundDifferences in expert practice: a case from formative evaluation
Saroyan, A. (1993) · Instructional Science · doi:10.1007/bf00118558 · Cited by 18 · cited 1×
“Because the development of the surgical simulator is in its very early stages and the primary goal is to validate the haptics, this formative evaluation involved only experts [19].”
BackgroundMedley-Mark, V., & Weston, C. (1988) · Instructional Science · doi:10.1007/bf00121231 · Cited by 14
O’Neill, B. (1993) · SIMULATION · doi:10.1177/003754979306100606 · Cited by 2
Research works printed but not linked: 2
- J.E. Colgate, M.C. Stanley, J.M. Brown, Issues in the haptic display of tool use, Trans. IROS 1995.
- Chen, 1998, Force feedback for surgical simulation, Proc. IEEE, 86, 524, 10.1109/5.662877 · DOI
Cited by
Use of Simulation Technology in Dental Education
Buchanan, J. A. (2001) · Journal of Dental Education · doi:10.1002/j.0022-0337.2001.65.11.tb03481.x · Cited by 225
“The IDSS unit is also still in its early stages of development, but it focuses more on tactile skill development and less on psychomotor skill development.(20,21) Haptic skills, such as the detection of carious lesions, are difficult to teach since the expert cannot feel the force exerted by the student and the respon…”
BackgroundVirtual reality for medical training: the state-of-the-art
Ruthenbeck, G. S., & Reynolds, K. J. (2015) · Journal of Simulation · doi:10.1057/jos.2014.14 · Cited by 173
“Researchers at Stanford University have also produced several haptically interactive VR medical training simulations for temporal bone surgery (Morris et al , 2004), craniofacial surgery (Morris et al, 2005), and dental surgery (Thomas et al , 2001).”
BackgroundA Preliminary Study in Using Virtual Reality to Train Dental Students
LeBlanc, V. R., Urbankova, A., Hadavi, F., & Lichtenthal, R. M. (2004) · Journal of Dental Education · doi:10.1002/j.0022-0337.2004.68.3.tb03754.x · Cited by 157
“and assessment of haptic (or tactile-based) skills, such as the ability to detect carious lesions.(9) Simulators are also used in preclinical training of dental students,”
BackgroundBone drilling haptic interaction for orthopedic surgical simulator
Tsai, M., Hsieh, M., & Tsai, C.-H. (2007) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2007.04.006 · Cited by 144
“The bone burring simulations use a model assuming that the cutting force is proportional to the immersed depth of the bur into the bone or the tooth [33,34].”
BackgroundNassar, H. M., & Tekian, A. S. (2020) · Journal of Dental Education · doi:10.1002/jdd.12138 · Cited by 129
Metadata
- Authors
- Thomas, G., Johnson, L., Dow, S., & Stanford, C.
- Affiliations
- University of Iowa (US)
- Corresponding author
- Thomas, Geb
- Venue
- Computer Methods and Programs in Biomedicine
- Publisher
- Elsevier BV
- Published
- 2001-01
- Volume
- 64
- Issue
- 1
- Pages
- 53-64
- ISSN
- 0169-2607 (ISSN-L)
- OpenAlex
- W2021838396
- Cited by
- 73
- References
- 22
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 3 · 2022: 5 · 2021: 4 · 2020: 3 · 2019: 1 · 2018: 3 · 2017: 3 · 2016: 2 · 2015: 3 · 2014: 5 · 2013: 3 · 2012: 4
- FWCI
- 1.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Computer Methods and Programs in Biomedicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Surgical Simulation and Training
- Physical Sciences › Engineering › Biomedical Engineering › Anatomy and Medical Technology
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Keywords
- haptic simulation, dental simulators, force feedback, caries detection, dental education, simulator evaluation
- MeSH terms
- Biophysics, Computer-Assisted Instruction, Dental Caries, Models, Dental, Education, Dental, Graduate, Equipment Design, Feedback, Humans, Surveys and Questionnaires, Biophysical Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.