Localized harmonic motion imaging: theory, simulations and experiments
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Timoshenko, S. P., & Goodier, J. N. (1934) · Virtual Defense Library (Ministerio de Defensa) · Cited by 13,717
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Elastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703 · cited 4×
“In the field of ultrasound (US), Krouskop et al. (1998) estimated vibration motion amplitudes and related them to estimates of elastic modulus by measuring the Doppler shifts of ultrasonic tone bursts.”
BackgroundInfluentialAcoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility
Nightingale, K., Soo, M. S., Nightingale, R., & Trahey, G. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00499-9 · Cited by 1,108 · cited 3×
“Localized harmonic motion imaging diagram. of the radiation force generating transducer(s) and c is the speed of sound (Nightingale et al. 1999, 2001, 2002 ).”
BackgroundMethodElastography of breast lesions: initial clinical results.
Garra, B. S., Cespedes, E. I., Ophir, J., Spratt, S. R., Zuurbier, R. A., Magnant, C. M., & Pennanen, M. F. (1997) · Radiology · doi:10.1148/radiology.202.1.8988195 · Cited by 940 · cited 1×
“…rights reserved 0301-5629/03/$–see front matter good quality strain images (or, elastograms) in several tissues, such as in vivo breast cancer (Céspedes et al. 1993; Garra et al. 1997; Ophir et al. 2001), in vitro normal prostate (Konofagou and Ophir 1998) and in vitro kidney (Ophir et al. 2001).”
BackgroundOn the feasibility of remote palpation using acoustic radiation force
Nightingale, K. R., Palmeri, M. L., Nightingale, R. W., & Trahey, G. E. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1378344 · Cited by 731 · cited 4×
“Localized harmonic motion imaging diagram. of the radiation force generating transducer(s) and c is the speed of sound (Nightingale et al. 1999, 2001, 2002 ).”
BackgroundMethodInfluentialUltrasound-Stimulated Vibro-Acoustic Spectrography
Fatemi, M., & Greenleaf, J. F. (1998) · Science · doi:10.1126/science.280.5360.82 · Cited by 642 · cited 6×
“…of the mechanical stimulus using an ultrasonic beam has been of particular interest in the last few years (Fatemi and Greenleaf 1998; Nightingale et al. 2001; 2002) with applications on artery calcifications (Fatemi and Greenleaf 1998) and in vivo normal breast (Nightingale et al. 2001).”
BackgroundMethodInfluentialPhantom materials for elastography
Hall, T. J., Bilgen, M., Insana, M. F., & Krouskop, T. A. (1997) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.656639 · Cited by 516 · cited 3×
“Gel phantoms moduli as calculated from the agar concentration given (Hall et al. 1997) mersed in a 0.9% saline.”
BackgroundMethodInfluentialTissue response to mechanical vibrations for “sonoelasticity imaging”
Parker, K. J., Huang, S. R., Musulin, R. A., & Lerner, R. M. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90003-u · Cited by 478 · cited 1×
“Parker et al. (1990) measured the tissue response to mechanical vibrations for " sonoelasticity imaging " and have reported results on the applications on in vitro muscle (Levinson et al. 1995) and in vitro prostate (Taylor et al. 2000).”
BackgroundKonofagou, E., & Ophir, J. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00109-4 · Cited by 444 · cited 2×
“Tracking of RF lines was performed using cross-correlation techniques (Konofagou and Ophir 1998; Konofagou 1999) and the displacement was estimated at a frequency of 3 kHz to adequately sample the harmonic motion (Fig.”
BackgroundMethodSelf-citationElastography: Elasticity Imaging Using Ultrasound with Application to Muscle and Breast In Vivo
Cespedes, I. (1993) · Ultrasonic Imaging · doi:10.1006/uimg.1993.1007 · Cited by 414
Shear modulus imaging with 2-D transient elastography
Sandrin, L., Tanter, M., Catheline, S., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.996560 · Cited by 412 · cited 1×
“In ultrasound, a more recent technique, transient elastography, also utilizes the propagation of low frequency pulsed shear waves in order to measure the underlying shear modulus (Sandrin et al. 2002).”
MethodSonoelastic determination of human skeletal muscle elasticity
Levinson, S. F., Shinagawa, M., & Sato, T. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00173-2 · Cited by 203 · cited 1×
“Parker et al. (1990) measured the tissue response to mechanical vibrations for " sonoelasticity imaging " and have reported results on the applications on in vitro muscle (Levinson et al. 1995) and in vitro prostate (Taylor et al. 2000).”
BackgroundThree-dimensional sonoelastography: principles and practices
Taylor, L. S., Porter, B. C., Rubens, D. J., & Parker, K. J. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/306 · Cited by 168 · cited 1×
“Parker et al. (1990) measured the tissue response to mechanical vibrations for " sonoelasticity imaging " and have reported results on the applications on in vitro muscle (Levinson et al. 1995) and in vitro prostate (Taylor et al. 2000).”
BackgroundKonofagou, E. E., Thierman, J., & Hynynen, K. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/11/314 · Cited by 82 · cited 2×
“To model tissues containing tumors, finite-element simulations of mechanical targets, of size 40 mm by 40 mm, that contain inclusions of distinct stiffness from the surrounding medium, were considered (Konofagou et al. 2001).”
BackgroundSelf-citationKonofagou, E. E., Thierman, J., & Hynynen, K. (2003) · Ultrasonics · doi:10.1016/s0041-624x(03)00125-2 · Cited by 40
Self-citationKonofagou, E. E., & Hynynen, K. (2003) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.479933 · Cited by 3
Self-citation
Cited by
Imaging the elastic properties of tissue: the 20 year perspective
Parker, K. J., Doyley, M. M., & Rubens, D. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/r01 · Cited by 477
An Overview of Elastography-An Emerging Branch of Medical Imaging
Sarvazyan, A., J. Hall, T., W. Urban, M., Fatemi, M., R. Aglyamov, S., & S. Garra, B. (2011) · Current Medical Imaging Reviews · doi:10.2174/157340511798038684 · Cited by 428
Gong, Z., & Dai, Z. (2021) · Advanced Science · doi:10.1002/advs.202002178 · Cited by 320
Huang, Y.-P., Zheng, Y.-P., Wang, S.-Z., Chen, Z.-P., Huang, Q.-H., & He, Y.-H. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/1/015805 · Cited by 312
Acoustic Waves in Medical Imaging and Diagnostics
Sarvazyan, A. P., Urban, M. W., & Greenleaf, J. F. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2013.02.006 · Cited by 223
“In another method called harmonic motion imaging, modulated ultrasound is used to create a harmonic radiation force at frequencies of 10–200 Hz (Konofagou and Hynynen 2003; Maleke and Konofagou 2008; Konofagou and Maleke 2011).”
Method
Metadata
- Authors
- Konofagou, E. E., & Hynynen, K.
- Venue
- Ultrasound in Medicine & Biology
- Publisher
- Elsevier BV
- Published
- 2003-10
- Volume
- 29
- Issue
- 10
- Pages
- 1405-1413
- ISSN
- 0301-5629 (ISSN-L)
- OpenAlex
- W2065021138
- Cited by
- 184
- References
- 18
- FWCI
- 4.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.