Development of a microchannel evaporator model for a CO2 air-conditioning system
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Many previous models assumed uniform humidity and temperature distribution along the fin height, an adiabatic fin tip at half fin height, and did not consider partial dehumidification scenarios.
“However, many of these models assumed (1) uniform humidity and temperature distribution along the fin height, (2) adiabatic fin tip at half fin height, and (3) did not consider partial dehumidification scenarios.”
Cites
Air-side thermal hydraulic performance of multi-louvered fin aluminum heat exchangers
Kim, M.-H., & Bullard, C. W. (2002) · International Journal of Refrigeration · doi:10.1016/s0140-7007(01)00025-1 · Cited by 280 · see citing works
Self-citationHeat transfer and pressure drop characteristics of flat tube and louvered plate fin surfaces
Achaichia, A., & Cowell, T. A. (1988) · Experimental Thermal and Fluid Science · doi:10.1016/0894-1777(88)90032-5 · Cited by 235 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Shao, L.-L., Yang, L., & Zhang, C.-L. (2010) · Applied Energy · doi:10.1016/j.apenergy.2009.08.021 · Cited by 112 · see citing works
Kim, M.-H., Song, S., & Bullard, C. W. (2002) · International Journal of Refrigeration · doi:10.1016/s0140-7007(01)00061-5 · Cited by 39 · see citing works
Self-citationXiong, T., Liu, G., Gao, Q., Yan, G., & Yu, J. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105654 · Cited by 26 · see citing works
- Authors
- Kim, M.-H., & Bullard, C. W.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- Corresponding author
- Kim, Man-Hoe
- ORCID
- Kim, Man-Hoe
- Venue
- Energy
- Publisher
- Elsevier BV
- Published
- 2001-10
- Volume
- 26
- Issue
- 10
- Pages
- 931-948
- ISSN
- 0360-5442 (ISSN-L)
- OpenAlex
- W2061286638
- Cited by
- 78
- References
- 2
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 1 · 2023: 1 · 2022: 7 · 2021: 4 · 2020: 4 · 2019: 4 · 2018: 3 · 2017: 6 · 2016: 4 · 2015: 2 · 2014: 7 · 2013: 3 · 2012: 9
- FWCI
- 5.68
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Energy (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Funders
- University of Illinois at Urbana-Champaign
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Boiling Studies
- Keywords
- microchannel heat exchangers, evaporator modeling, CO2 refrigerant, mobile air conditioning, air-side heat transfer, pressure drop correlations, heat and mass transfer, wet conditions, finite volume method
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review