Determination of retinol and retinyl esters in human plasma by high-performance liquid chromatography with automated column switching and ultraviolet detection
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
A HPLC method with automated column switching and UV detection is described for the simultaneous determination of retinol and major retinyl esters (retinyl palmitate, retinyl stearate, retinyl oleate and retinyl linoleate) in human plasma. Plasma (0.2 ml) was deproteinized by adding ethanol (1.5 ml) containing the internal standard retinyl propionate. Following centrifugation the supernatant was directly injected onto the pre-column packed with LiChrospher 100 RP-18 using 1.2% ammonium acetate-acetic acid-ethanol (80:1:20, v/v) as mobile phase. The elution strength of the ethanol containing sample solution was reduced by on-line supply of 1% ammonium acetate-acetic acid-ethanol (100:2:4, v/v). The retained retinol and retinyl esters were then transferred to the analytical column (Superspher 100 RP-18, endcapped) in the backflush mode and chromatographed under isocratic conditions using acetonitrile-methanol-ethanol-2-propanol (1:1:1:1, v/v) as mobile phase. Compounds of interest were detected at 325 nm. The method was linear in the range 2.5-2000 ng/ml with a limit of quantification for retinol and retinyl esters of 2.5 ng/ml. Mean recoveries from plasma were 93.4-96.5% for retinol (range 100-1000 ng/ml) and 92.7-96.0% for retinyl palmitate (range 5-1000 ng/ml). Inter-assay precision was < or =5.1% and < or =6.3% for retinol and retinyl palmitate, respectively. The method was successfully applied to more than 2000 human plasma samples from clinical studies. Endogenous levels…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In fact, concentrations of endogenous ATRA in tissues are up to several orders of magnitude below the limit of detection and/or limit of quantification for both DAD and single-wavelength detection [279,280,281,282,283,284,285,286,287,288,289,290,291,292,293,294,295,320,321,322,323,324].”
From Vitamin A Update: Forms, Sources, Kinetics, Detection, Function, Deficiency, Therapeutic Use and Toxicity (2021) · cites this paper as [282]
Citations
Cites
Colowick, S. P., Joshi, M. D., Jagannathan, & KAPLAN, N. O. (1966) · Cited by 26,137
Modern Nutrition in Health and Disease.
(1988) · Annals of Internal Medicine · doi:10.7326/0003-4819-108-3-508_7 · Cited by 3,379
4-Dialkylaminopyridine als hochwirksame Acylierungskatalysatoren
Höfle, G., Steglich, W., & Vorbrüggen, H. (1978) · Angewandte Chemie · doi:10.1002/ange.19780900806 · Cited by 439
Sowell, A. L., Huff, D. L., Yeager, P. R., Caudill, S. P., & Gunter, E. W. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.3.411 · Cited by 252
Wang, X.-D., Tang, G.-W., Fox, J. G., Krinsky, N. I., & Russell, R. M. (1991) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(91)90322-a · Cited by 228
Eckhoff, C., & Nau, H. (1990) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)42615-x · Cited by 170
Separation of long-chain fatty acid esters of retinol by high-performance liquid chromatography
Ross, A. C. (1981) · Analytical Biochemistry · doi:10.1016/0003-2697(81)90013-0 · Cited by 93
van Breemen, R. B., Nikolic, D. S., Xu, X., Xiong, Y., Lieshout, M. V., West, C. E., & Schilling, A. B. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)01138-2 · Cited by 88
Wyss, R., & Bucheli, F. (1988) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)81107-x · Cited by 79
Self-citationChromatographic and electrophoretic analysis of biomedically important retinoids
Wyss, R. (1995) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/0378-4347(95)00154-b · Cited by 73
Self-citation
Research works printed but not linked: 4
- Olson, 1994, Vol. 1, 287
- Gundersen, 1999, Vol. 299, 430
- Giuliano, 1993, Vol. 214, 94
- Peiker, 1991, Zentralblatt Gynäkologie, 113, 1100
Cited by
Carazo, A., Macáková, K., Matoušová, K., Krčmová, L. K., Protti, M., & Mladěnka, P. (2021) · Nutrients · doi:10.3390/nu13051703 · Cited by 461
Scientific Opinion on Dietary Reference Values for vitamin A
EFSA Panel on Dietetic Products, N. (2015) · EFSA Journal · doi:10.2903/j.efsa.2015.4028 · Cited by 232
“500 In the fasting circulation, retinol bound to RBP4 is the predominant form of retinoid, with 501 concentrations ranging from 2–4 μmol/L in adults from Western countries (Chuwers et al., 1997; 502 Hartmann et al., 2001).”
BackgroundHPLC/UV quantitation of retinal, retinol, and retinyl esters in serum and tissues
Kane, M. A., Folias, A. E., & Napoli, J. L. (2008) · Analytical Biochemistry · doi:10.1016/j.ab.2008.03.038 · Cited by 171
Guaratini, T., Gianeti, M. D., & Campos, P. M. (2006) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2006.07.015 · Cited by 125
Paik, J., Haenisch, M., MULLER, C. H., Goldstein, A. S., Arnold, S. L. M., Isoherranen, N., Brabb, T., Treuting, P. M., & Amory, J. K. (2014) · Journal of Biological Chemistry · doi:10.1074/jbc.m113.540211 · Cited by 101
“Retinyl stearate, retinyl linoleate, and retinyl oleate were synthesized from retinol and corresponding fatty acids following a reported method (15).”
Method
Metadata
- Authors
- Hartmann, S., Froescheis, O., Ringenbach, F., Wyss, R., Bucheli, F., Bischof, S., Bausch, J., & Wiegand, U.-W.
- Affiliations
- F. Hoffmann-La Roche AG (CH)
- Corresponding author
- Froescheis, O
- Venue
- Journal of Chromatography B: Biomedical Sciences and Applications
- Publisher
- Elsevier BV
- Published
- 2001-02
- Volume
- 751
- Issue
- 2
- Pages
- 265-275
- ISSN
- 0378-4347 (ISSN-L)
- OpenAlex
- W2000708893
- Cited by
- 33
- References
- 28
- Citations by year
- 2021: 1 · 2019: 1 · 2016: 1 · 2015: 1 · 2014: 5 · 2013: 2 · 2012: 1
- FWCI
- 1.14
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Chromatography B Biomedical Sciences and Applications (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Retinoids in leukemia and cellular processes
- Keywords
- retinol, retinyl esters, retinyl palmitate, human plasma, vitamin A
- MeSH terms
- Automation, Calibration, Chromatography, High Pressure Liquid, Esters, Sensitivity and Specificity, Spectrophotometry, Ultraviolet, Vitamin A
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of retinol and retinyl esters in human plasma by high-performance liquid chromatography with automated column switching and ultraviolet detection. https://app.cochat.ai/papers/10.1016/s0378-4347(00)00481-3
- The paper
- Hartmann, S., Froescheis, O., Ringenbach, F., Wyss, R., Bucheli, F., Bischof, S., Bausch, J., & Wiegand, U.-W. (2001). Determination of retinol and retinyl esters in human plasma by high-performance liquid chromatography with automated column switching and ultraviolet detection. Journal of Chromatography B: Biomedical Sciences and Applications. https://doi.org/10.1016/s0378-4347(00)00481-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.