CoChat

Determination of retinol and retinyl esters in human plasma by high-performance liquid chromatography with automated column switching and ultraviolet detection

Hartmann, S, Froescheis, O, Ringenbach, F, Wyss, R, Bucheli, F, Bischof, S, Bausch, J, Wiegand, U.-W · 2001 · Journal of Chromatography B: Biomedical Sciences and Applications

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

A HPLC method with automated column switching and UV detection is described for the simultaneous determination of retinol and major retinyl esters (retinyl palmitate, retinyl stearate, retinyl oleate and retinyl linoleate) in human plasma. Plasma (0.2 ml) was deproteinized by adding ethanol (1.5 ml) containing the internal standard retinyl propionate. Following centrifugation the supernatant was directly injected onto the pre-column packed with LiChrospher 100 RP-18 using 1.2% ammonium acetate-acetic acid-ethanol (80:1:20, v/v) as mobile phase. The elution strength of the ethanol containing sample solution was reduced by on-line supply of 1% ammonium acetate-acetic acid-ethanol (100:2:4, v/v). The retained retinol and retinyl esters were then transferred to the analytical column (Superspher 100 RP-18, endcapped) in the backflush mode and chromatographed under isocratic conditions using acetonitrile-methanol-ethanol-2-propanol (1:1:1:1, v/v) as mobile phase. Compounds of interest were detected at 325 nm. The method was linear in the range 2.5-2000 ng/ml with a limit of quantification for retinol and retinyl esters of 2.5 ng/ml. Mean recoveries from plasma were 93.4-96.5% for retinol (range 100-1000 ng/ml) and 92.7-96.0% for retinyl palmitate (range 5-1000 ng/ml). Inter-assay precision was < or =5.1% and < or =6.3% for retinol and retinyl palmitate, respectively. The method was successfully applied to more than 2000 human plasma samples from clinical studies. Endogenous levels…

Overview

Integrity signals

Registry

Crossref · 10.1016/s0378-4347(00)00481-3

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 28 references

Research works printed but not linked: 4

  1. Olson, 1994, Vol. 1, 287
  2. Gundersen, 1999, Vol. 299, 430
  3. Giuliano, 1993, Vol. 214, 94
  4. Peiker, 1991, Zentralblatt Gynäkologie, 113, 1100

Cited by

See all 33

Metadata

Authors
Hartmann, S., Froescheis, O., Ringenbach, F., Wyss, R., Bucheli, F., Bischof, S., Bausch, J., & Wiegand, U.-W.
Affiliations
F. Hoffmann-La Roche AG (CH)
Corresponding author
Froescheis, O
Venue
Journal of Chromatography B: Biomedical Sciences and Applications
Publisher
Elsevier BV
Published
2001-02
Volume
751
Issue
2
Pages
265-275
ISSN
0378-4347 (ISSN-L)
OpenAlex
W2000708893
Cited by
33
References
28
Citations by year
2021: 1 · 2019: 1 · 2016: 1 · 2015: 1 · 2014: 5 · 2013: 2 · 2012: 1
FWCI
1.14
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Journal of Chromatography B Biomedical Sciences and Applications (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Retinoids in leukemia and cellular processes
Keywords
retinol, retinyl esters, retinyl palmitate, human plasma, vitamin A
MeSH terms
Automation, Calibration, Chromatography, High Pressure Liquid, Esters, Sensitivity and Specificity, Spectrophotometry, Ultraviolet, Vitamin A

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of retinol and retinyl esters in human plasma by high-performance liquid chromatography with automated column switching and ultraviolet detection. https://app.cochat.ai/papers/10.1016/s0378-4347(00)00481-3
The paper
Hartmann, S., Froescheis, O., Ringenbach, F., Wyss, R., Bucheli, F., Bischof, S., Bausch, J., & Wiegand, U.-W. (2001). Determination of retinol and retinyl esters in human plasma by high-performance liquid chromatography with automated column switching and ultraviolet detection. Journal of Chromatography B: Biomedical Sciences and Applications. https://doi.org/10.1016/s0378-4347(00)00481-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.