Abstract

Retinol and retinyl esters are measured in serum or plasma samples by gradient, normal-phase, adsorption "high-performance" liquid chromatography, with ultraviolet detection at 325 nm. The four major circulating retinyl esters in humans (esters of palmitate, stearate, oleate, and linoleate) are coeluted as a single peak. Retinyl acetate is included as an internal standard, to correct for variable recovery. Retinol values so measured correlated well (r = 0.88) with those by a widely used reversed-phase chromatographic technique (Clin Chem 1983;29:708-12). The mean retinol concentration was 570 (SEM 17) micrograms/L and the mean for retinyl esters was 33 (SEM 4) micrograms/L as determined in samples from 88 fasting young adults. Concentrations of retinol in plasma as low as 50 micrograms/L can be detected in 100-microL samples, as can 10 micrograms of retinyl esters per liter. Using this method, we measured absorption of low doses of vitamin A, which may provide a more physiological approach to assessment of fat malabsorption. Additionally, the procedure proved useful for quickly screening for vitamin A toxicity. Major advantages include small sample size, direct injection of the extract ed sample without evaporation, rapid elution pattern, co-elution of major retinyl esters as a single peak, and low limit of detection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/32.1.35

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 71

Metadata

Authors
Bankson, D. D., Russell, R. M., & Sadowski, J. A.
Venue
Clinical Chemistry
Published
1986-01-01
Volume
32
Issue
1
Pages
35-40
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1923757058
Cited by
71
References
1
FWCI
4.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of retinyl esters and retinol in serum or plasma by normal-phase liquid chromatography: method and applications. https://app.cochat.ai/papers/10.1093/clinchem/32.1.35
The paper
Bankson, D. D., Russell, R. M., & Sadowski, J. A. (1986). Determination of retinyl esters and retinol in serum or plasma by normal-phase liquid chromatography: method and applications. Clinical Chemistry. https://doi.org/10.1093/clinchem/32.1.35

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.